Reference ManualIntroduction
00809-0100-4549December 2019
1Introduction
The Net Safety UDM-003 (Universal Duct Mount) is Net Safety's latest design for allowing
sensors to monitor ducts. With its angular design and flexibility, it firmly supports a variety
of Net Safety's sensors with multipurpose junction boxes to ducts.
Mount the Net Safety UDM-003 with the following sensors:
• Net Safety Millennium II Series sensors
• Net Safety Millennium Premium ST Series sensors
• Gas shield sensors
The instructions in this Reference Manual will guide you in setting up and mounting the
Net Safety UDM-003 with a sensor and multipurpose junction box to a duct. In order to
ensure proper and safe mounting, follow the instructions given and ensure that all screws,
nuts, and bolts are tightly fitted. When calibrating, refer to the specific Reference Manual
as required. Emerson recommends using a 2.5 (or greater) liters per minute regulator
when calibrating.
WARNING
Never install the Net Safety UDM-003 at the bottom (underside) of a duct.
Net Safety Universal Duct Mount5
Page 6
IntroductionReference Manual
December 201900809-0100-4549
6Emerson.com/Rosemount
Page 7
Reference Manual
00809-0100-4549December 2019
Mounting
2Mounting
Figure 2-1: Mounting the Net Safety UDM-003
A. Conduit to controller
B. Net Safety UDM-003 and sensor with junction box mounted on top of duct
C. Calibration cup with tubing
D. Insertion distance
E. Duct
F. Controller
G. Calibration tubing
H. Calibration gas
Figure 2-1, showing the mounting of the Net Safety UDM-003 and sensor with junction
box to a duct, is a general representation.
2.1Fit Net Safety UDM-003 to duct
Procedure
1. Locate the desired place on the duct to mount the Net Safety UDM-003.
Net Safety Universal Duct Mount7
Page 8
MountingReference Manual
December 201900809-0100-4549
Note
Fit sensor and junction box to the Net Safety UDM-003 before mounting to duct.
2. Use the template provided for drilling and cutting holes in the duct. Use a small
pilot drill to drill holes for the provided self tapping screws.
For a proper fit, make sure holes on the template are concentric to holes on the
duct. See Figure 2-2.
Figure 2-2: Net Safety UDM-003 Template
Measurements are in inches.
A. Recommended 0.125-in. pilot hole
B. Cut line
3. Fit a calibration cup with tubing to the Net Safety UDM-003 as illustrated in Figure
2-1. Secure the sensor and junction box to the Net Safety UDM-003 with the screws,
washers, and nuts provided.
2.2Insertion distance
• 5.1 in. (130 mm) for Net Safety Millennium II series sensors
• 6.3 in. (160 mm) for Net Safety ST series sensors
8Emerson.com/Rosemount
Page 9
Reference ManualSpecifications
00809-0100-4549December 2019
3Specifications
Material
Weight (Net Safety UDM-003 without sensor and junction box)
The Emerson logo is a trademark and service mark of Emerson Electric Co. Net Safety is a mark of
one of the Emerson family of companies. All other marks are the property of their respective owners.