Rosemount Quick Start Guide: SmartPower Solutions Manuals & Guides

SmartPower™ Solutions
Quick Start Guide
00825-0100-4701, Rev DD
April 2021
Quick Start Guide April 2021
Safety Messages
NOTICE
WARNING
Explosions could result in death or serious injury.
Installation of this power module in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Review the Product Certifications section for any restrictions associated with a safe installation.
Before connecting a handheld communicator in an explosive atmosphere, ensure the instruments
are installed in accordance with intrinsically safe or non-incendive field wiring practices.
Electrical shock could cause death or serious injury.
Avoid contact with the leads and terminals. High voltage that may be present on leads can cause
electrical shock.
The power module may be replaced in a hazardous area. The power module has surface resistivity
greater than one gigaohm and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.
CAUTION
Each Black Power Module contains two “C” size primary lithium-thionyl chloride battery. Primary lithium batteries are regulated in transportation by the U. S. Department of Transportation, and are also covered by IATA (International Air Transport Association), ICAO (International Civil Aviation Organization), and ARD (European Ground Transportation of Dangerous Goods). It is the responsibility of the shipper to ensure compliance with these or any other local requirements. Consult current regulations and requirements before shipping.
Contents
Warning on product labels........................................................................................................... 3
Physical installation...................................................................................................................... 4
Verify operation........................................................................................................................... 6
Disposal/recycling of depleted power modules............................................................................ 9
Product Certifications.................................................................................................................10
2 Emerson.com/Rosemount
April 2021 Quick Start Guide

1 Warning on product labels

The Rosemount 701P power modules each have a warning printed on them. In each case the warning text is the same. Below is a figure that shows each label.
The text of the warning is: “WARNING Potential Static Hazard, Use Caution when Handling. Risk of Fire, Explosion or Severe Burn Hazard. DO NOT Recharge, Disassemble, Heat above 100 °C, Incinerate or Expose Contents to Water. Li metal content approx 5g.”
Figure 1-1: Warning Label on 701PBK
Figure 1-2: Warning Label on 701PGN
Quick Start Guide 3
Quick Start Guide April 2021

2 Physical installation

There are two types of power modules that will be discussed in this document. They are the black power module (701PBK) and the green power module (701PGN).

2.1 Installing Black power module (701PBK)

Prerequisites
Install the HART® device according to standard installation practices and the manufacturer’s instructions, being sure to use an approved thread sealant on all connections.
Procedure
1. Unscrew the power module cover from the wireless device.
2. Connect the power module to the wireless device. The power module has a keyed connection to prevent improper connection.
Note
Wireless devices should be powered up in order of proximity from the Smart Wireless Gateway, beginning with the closest device to the Gateway. This will result in a simpler and faster network installation.
3. Connect the power module to the wireless device. The power module has a keyed connection to prevent improper connection.
Figure 2-1: Black Power Module Installation
2.2
4 Emerson.com/Rosemount

Installing Green power module (701PGN)

Prerequisites
Install the HART device according to standard installation practices and the manufacturer’s instructions, being sure to use an approved thread sealant on all connections.
April 2021 Quick Start Guide
Procedure
1. Unscrew the power module cover from the wireless device.
2. Connect the green power module to the wireless device. The green power module has a keyed connection to prevent improper connection. If the Green power module is placed into the housing the wrong way, it will not fit entirely into the housing.
Note
Wireless devices should be powered up in order of proximity from the Smart Wireless Gateway, beginning with the closest device to the Gateway. This will result in a simpler and faster network installation.
3. Close the housing cover and tighten. Ensure the power module cover is fully tightened to prevent moisture ingress. The lip of the polymer power module cover should be in contact with the surface of the polymer enclosure to ensure a proper seal. Do not over tighten.
Figure 2-2: Green Power Module Installation
Quick Start Guide 5
$
&
%
1 2 3
4 5 6
7 809
Quick Start Guide April 2021

3 Verify operation

Operation can be verified in four locations: by using the Field Communicator, at the Gateway via the Wireless Gateway’s integrated web server, via AMS Wireless Configurator, or with the wireless device’s LCD display.

3.1 Verify operation using Field Communicator

If you are able to communicate to the wireless device via a Field Communicator, the power module is powering the device and working correctly. Figure 5 shows how to connect a Field Communicator to a wireless device with either the black or green power module.
Figure 3-1: Connect to Device
A. Communication terminals B. Handheld communicator C. HART modem
6 Emerson.com/Rosemount
Loading...