Quick Start Guide
00825-0100-4145, Rev CA
February 2021
Rosemount™ Smart Pressure Gauge

Quick Start Guide February 2021
This guide provides basic guidelines for Rosemount Smart Pressure Gauges. It does not provide
instructions for configuration, diagnostics, maintenance, service, troubleshooting, or intrinsically safe
(I.S.) installations. Refer to the Rosemount Smart Pressure Gauge Reference Manual for more
instruction. The manual and this guide are also available electronically.
NOTICE
Shipping considerations
The device is shipped with the battery installed.
Each device contains one “D” size primary lithium-thionyl chloride battery. Primary lithium
batteries are regulated in transportation by the U.S. Department of Transportation, and are also
covered by IATA (International Air Transport Association), ICAO (International Civil Aviation
Organization), and ARD (European Ground Transportation of Dangerous Goods). It is the
responsibility of the shipper to ensure compliance with these or any other local requirements.
Consult current regulations and requirements before shipping.
WARNING
Explosions could result in death or serious injury.
Installation of device in an explosive environment must be in accordance with appropriate local,
national, and international standards, codes, and practices.
Ensure device is installed in accordance with intrinsically safe or non-incendive field practices.
Electrical shock could cause death or serious injury.
Device must be installed to ensure a minimum antenna separation distance of 8 in. (20 cm) from
all persons.
Care must be taken during transportation of device to prevent electrostatic charge build-up.
Process leaks could result in death or serious injury.
Handle the device carefully.
Failure to follow these installation guidelines could result in death or serious injury.
Ensure only qualified personnel perform the installation.
Contents
Required equipment.................................................................................................................... 3
What’s in the box......................................................................................................................... 4
Optional: Power/device check...................................................................................................... 6
Optional: Normal range indication option.................................................................................... 7
Installation procedure.................................................................................................................. 8
Troubleshooting........................................................................................................................ 12
Product certifications................................................................................................................. 13
Declaration of conformity.......................................................................................................... 17
China RoHS................................................................................................................................ 20
2 Emerson.com/Rosemount

February 2021 Quick Start Guide
1 Required equipment
Figure 1-1: Anti-seize paste or PTFE tape (for NPT threaded connection)
Figure 1-2: Standard tools (e.g., screwdriver, wrench, pliers)
Quick Start Guide 3

Quick Start Guide February 2021
2 What’s in the box
Smart Pressure Gauge Quick Start Guide
The following options are also available and will ship with the Rosemount
Smart Pressure Gauge if ordered.
Rosemount 306 Integral Manifold
(model code S5)
4 Emerson.com/Rosemount
B4 bracket (model code B4)

February 2021 Quick Start Guide
Rosemount 1199 Seal(model code S1) Product Certification
Q4: Calibration Cert
QG: Calibration Cert and GOST
Verification Cert
QP: Calibration Cert and Tamper
Evident Seal
Q8: Material Traceability cert per EN
102043.1
Q15: Cert of Compliance to NACE
MR0175/ISO 15156 for wetted materials
Q25: Cert of Compliance to NACE
MR00103 for wetted materials
Normal range Indication (model code LK) Product Certification model codes
Quick Start Guide 5

Quick Start Guide February 2021
3 Optional: Power/device check
The device is designed to be installation-ready.
Procedure
1. To check device battery prior to installation, perform Turn on device
2. Slide the ON/OFF switch to the OFF position until ready for use.
6 Emerson.com/Rosemount

February 2021 Quick Start Guide
4 Optional: Normal range indication option
Important
• The stickers are intended to be installed on the dial only and should not
be applied on the inside or outside of the housing cover.
• Stickers should be applied in an environment where the ambient
temperature is above 50 °F (10 °C)
Procedure
1. Modify each of the stickers to desired size.
2. Remove housing cover.
3. Slide ON/OFF switch to the OFF position and wait for the LED to stop
flashing.
4. Gently move the needle in the clockwise direction until it is pointing
at the red X.
NOTICE
Equipment Damage
Use caution as the electronics assembly is connected to the needle.
5. Remove any debris on the dial, so it does not become trapped under
the sticker.
6. Peel back the white paper backing of the sticker.
7. Slowly lower the sticker onto the surface of the dial in the desired
location and rub it in place firmly. Repeat steps Step 6 and Step 7
until desired indication locations are set.
Moving the sticker after initial contact is not recommended as this
decreases the amount of adhesive on the back of the sticker.
8. Slide ON/OFF switch to the ON position.
9. Replace housing cover.
Quick Start Guide 7

Quick Start Guide February 2021
5 Installation procedure
Procedure
1. Seal and protect threads
2. Mount device
Note
Use wrench on flats, not on housing.
5.1
Mounting orientation
The low side pressure port (atmospheric reference) is located in the neck of
the device behind the housing.
The vent path is between the housing and sensor.
8 Emerson.com/Rosemount