Rosemount Quick Start Guide: Rosemount 415 Fire Pump Manuals & Guides

Quick Installation Guide
00825-0100-4830, Rev AA January 2004
Rosemount 415 Fire Pump
Rosemount 415 Fire Pump
Step 1: Location and Orientation
Step 3: Weld Mounting Hardware
Step 4: Insert the Annubar
¢00825-0100-4830e¤
www.rosemount.com
Quick Installation Guide
00825-0100-4830, Rev AA January 2004
© 2004 Rosemount Inc. All rights reserved. All marks are the property of their owners.
Rosemount Inc.
8200 Market Boulevard Chanhassen, MN USA 55317 T (US) (800) 999-9307 T (Intnl) (952) 906-8888 F (952) 949-7001
Emerson Process Management Asia Pacific Private Limited
1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947/65 6777 0743
Rosemount 415 Fire Pump
Emerson Process Management GmbH & Co. OHG
Argelsrieder Feld 3 82234 Wessling Germany T 49 (8153) 9390 F49 (8153) 939172
Beijing Rosemount Far East Instrument Co., Limited
No. 6 North Street, Hepingli, Dong Cheng District Beijing 100013, China T (86) (10) 6428 2233 F (86) (10) 6422 8586
IMPORTANT NOTICE
This installation guide provides basic guidelines for Rosemount Eagle Eye Fire Pump. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flame-Proof, or instrinsically safe (I.S.) installations. Refer to the Rosemount Eagle Eye Series Product Data Sheet (document number 00813-0100-4830) or the Eagle Eye QIG (document number 00825-0100-4833) for more information. These documents are also available electronically on www.rosemount.com.
WARNING
Process leaks may cause harm or result in death. To avoid process leaks, only use gaskets designed to seal with the corresponding flange and o-rings to seal process connections. Flowing medium may cause the 485 Annubar assembly to become hot and could result in burns.
Quick Installation Guide
00825-0100-4830, Rev AA January 2004
need
EXPLODED VIEW
Annubar Sensor
Pak-Lok Body
1
/8-in. NPT x 1/4-in. Reducer
1
/8-in. Ball Valve
1
/8-in. NPT x 1/4-in.
SAE Flare Adapter
Mounting U-Bolt
Rosemount 415 Fire Pump
Packing Rings (3)
Stud
Compression Plate
Washer
Nut
1
/4-in. O.D. Tube
Eagle Eye Indicator
31-490000-901A
Quick Installation Guide
00825-0100-4830, Rev AA January 2004
Rosemount 415 Fire Pump
STEP 1: LOCATION AND ORIENTATION
Correct orientation and straight run requirements must be met for accurate and repeatable flow measurements. Refer to Table 1 for minimum pipe diameter distances from upstream disturbances.
Table 1. Straight Run Requirements
Upstream Dimensions
Without Vanes With Vanes
In
Out of
Plane A
Plane A
1
8
2
11
A’ C C’
10——8—4—44
16——8—4—44
Downstream
4
4
Dimensions
3
23
28——8—4—44