Short Form Manual
HASXEE-SFM-HS
07/2010
Gas Analyzer Series
Short Form Manual
www.EmersonProcess.com
ESSENTIAL INSTRUCTIONS
READ THIS PAGE BEFORE PROCEEDING!
Emerson Process Management (Rosemount Analytical) designs, manufactures and
tests its products to meet many national and international standards. Because these
instruments are sophisticated technical products, you MUST properly install, use, and maintain them to ensure they continue to operate within their normal specications.
The following instructions MUST be adhered to and integrated into your safety program
when installing, using and maintaining Emerson Process Management (Rosemount
Analytical) products. Failure to follow the proper instructions may cause any one of the
following situations to occur: Loss of life; personal injury; property damage; damage to
this instrument; and warranty invalidation.
• Read all instructions prior to installing, operating, and servicing the product.
• If you do not understand any of the instructions, contact your Emerson Process
Management (Rosemount Analytical) representative for clarication.
• Follow all warnings, cautions, and instructions marked on and supplied with the
product.
• Inform and educate your personnel in the proper installation, operation, and
maintenance of the product.
• Install your equipment as specied in the Installation Instructions of the
appropriate Instruction Manual and per applicable local and national codes.
Connect all products to the proper electrical and pressure sources.
• To ensure proper performance, use qualied personnel to install, operate, update,
program, and maintain the product.
• When replacement parts are required, ensure that qualied people use replacement
parts specied by Emerson Process Management (Rosemount Analytical).
Unauthorized parts and procedures can affect the product’s performance, place the
safe operation of your process at risk, and VOID YOUR WARRANTY. Look-alike
substitutions may result in re, electrical hazards, or improper operation.
• Ensure that all equipment doors are closed and protective covers are in place,
except when maintenance is being performed by qualied persons, to prevent
electrical shock and personal injury.
The information contained in this document is subject to change without notice.
3rd edition 2010-07
Emerson Process Management GmbH & Co. OHG
Industriestrasse 1
D-63594 Hasselroth
Germany
T +49 (0) 6055 884-0
F +49 (0) 6055 884-209
Internet: www.EmersonProcess.com
This short form manual provides information on installation and startup of the
X-STREAM® XE series gas analyzers. For comprehensive instructions see the X-STREAM
XE series instruction manual.
This manual covers several X-STREAM analyzer models and so may contain information
about congurations and/or options not applicable to your analyzer.
The installation and operation of units for use in explosive (hazardous) environments is
not covered in this manual.
Analyzers intended to be used in such environments are supplied with further instruction
manuals, which should be consulted in addition to this.
DEFINITIONS
The following denitions apply to WARNINGS, CAUTIONS and NOTES found throughout
this publication.
HIGHLIGHTS AN OPERATION OR MAINTENANCE PROCEDURE,
PRACTICE, CONDITION, STATEMENT, ETC.
If not strictly observed, could result in injury, death, or long-term health
hazards of personnel.
Safety Instructions
S
HIGHLIGHTS AN OPERATION OR MAINTENANCE PROCEDURE,
PRACTICE, CONDITION, STATEMENT, ETC.
If not strictly observed, could result in damage to or destruction of equipment,
or loss of effectiveness.
NOTE!
Highlights an essential operating procedure, condition or statement.
Emerson Process Management GmbH & Co. OHG S-1
X-STREAM XE
TERMS USED IN THIS INSTRUCTION MANUAL
Short Form Manual
HASXEE-SFM-HS
04/2010
Explosive Gas(es)
Flammable Gases and gas mixtures in a mixture with air within the explosive limits.
Flammable Gas(es)
Gases and gas mixtures are assigned to be
ammable if they might become ignitable
when in a mixture with air.
Infallible Containment
This term is derived from the standards of
explosion protection especially from the requirements for pressurized housings: thus an
infallible containment can be characterized
by no intended leakage out of the gas paths
enabling gas to enter the inner compartment
of the analyzer housing.
Intrinsically Safe Cell (IS Cell)
Cells supplied with an intrinsically safe power
signal, approved by a Test Institute, to operate
with explosive gases.
The design ensures the IS cells remains safe
even in case of failure and explosive gases
are not ignited.
Protection Class IP66 / NEMA 4X
Both terms are used to specify conditions for
equipment to be installed outdoor.
IP stands for Ingress Protection, the rst number species protection against solid objects
(6. = dust tight) while the second number
species the degree of protection against
liquids (.6 = heavy seas).
NEMA stands for National Electrical Manufacturers Association. 4X species a degree
of protection to personnel against incidental
contact with the enclosed equipment; to provide a degree of protection against falling dirt,
rain, sleet, snow, windblown dust, splashing
water, and hose-directed water; and that will
be undamaged by the external formation of
ice on the enclosure
Upper Explosion Limit (UEL)
Volume ratio of ammable gas in air above
which an explosive gas atmosphere will not
be formed: the mixture of gas and air is too
rich in fuel (decient in oxygen) to burn.
Lower Explosion Limit (LEL)
Volume ratio of ammable gas in air below
which an explosive gas atmosphere will not
be formed: the mixture of gas and air lacks
sufcient fuel (gas) to burn.
NAMUR
NAMUR is an international user association of
automation technology in process industries.
This organisation has issued experience reports and working documents, called recommendations (NE) and worksheets (NA).
Emerson Process Management GmbH & Co. OHGS-2
Short Form Manual
HASXEE-SFM-HS
04/2010
Safety Instructions
X-STREAM XE
SYMBOLS USED ON AND INSIDE THE UNIT
Wherever one or more of the following symbols appear on or inside the instrument, be careful
and read the instructions given in the accompanying manuals!
Strictly observe the given warnings, instructions and information to minimize hazards!
This symbol at the instrument ...... means
dangerous voltages may be accessible. Removing covers is permitted only, if the instrument is
disconnected from power - and even in this case
by qualied personnel only!
hot surfaces may be accessible. Removing
covers by qualied personnel is permitted only,
if the instrument is disconnected from power.
Nevertheless several surfaces may remain hot
for a limited time.
more detailled information available: see instruction manual before proceeding!
more detailled information available: see instruction manual before proceeding!
Safety Instructions
S
Emerson Process Management GmbH & Co. OHG S-3
Short Form Manual
X-STREAM XE
Safety Instructions
HASXEE-SFM-HS
04/2010
SYMBOLS USED IN THIS MANUAL
Where one or more of the following symbols appear within this manual, carefully read the related information and instructions!
Strictly observe the given warnings, instructions and information to minimize hazards!
This symbol used in the manual ...... means
dangerous voltages may be exposed
hot surfaces may be exposed
possible danger of explosion
toxic substances may be present
substances harmful to health may be present
indicates notes relating to heavy instruments
electrical components may be destroyed by
electrostatic discharges
units must be disconnected from the power
source
indicates special instructions or information for
operation at low temperatures.
indicates basic conditions or procedures are
being described.
This symbol may also indicate information important for achieving accurate measurements.
Emerson Process Management GmbH & Co. OHGS-4
Short Form Manual
HASXEE-SFM-HS
04/2010
Safety Instructions
X-STREAM XE
SAFETY INSTRUCTIONS
INTENDED USE STATEMENT
X-STREAM XE series gas analyzers are intended to be used as analyzers for industrial
purposes. They must not be used in medical, diagnostic or life support applications.
Using X-STREAM XE analyzers as safety devices is prohibited where redundancy and/or
SIL classication or equivalent is needed.
No independent agency certications or approvals are to be implied as covering such
applications!
Safety Instructions
S
GENERAL SAFETY NOTICE / RESIDUAL RISK
If this equipment is used in a manner not specied in these instructions, protective systems may be impaired.
Despite of incoming goods inspections, production control, routine tests and application
of state-of-the-art measuring and test methods, an element of risk remains when operating
a gas analyzer!
Even when operated as intended and observing all applicable safety instructions some
residual risks remain, including, but not limited to, the following:
• An interruption of the protective earth line, e.g. in an extension cable, may result in
risk to the user.
• Live parts are accessible when operating the instrument with doors open or covers
removed.
• The emission of gases hazardous to health may even be possible when all gas connections have been correctly made.
Avoid exposure to the dangers of these residual risks by taking particular care when installing, operating, maintaining and servicing the analyzer.
Emerson Process Management GmbH & Co. OHG S-5
Short Form Manual
X-STREAM XE
Safety Instructions
HASXEE-SFM-HS
04/2010
AUTHORIZED PERSONNEL
In-depth specialist knowledge is an absolutely necessary condition for working with and
on the analyzer.
Authorized personnel for installing, operating, servicing and maintaining the analyzer are
instructed and trained qualied personnel of the operating company and the manufacturer.
It is the responsibility of the operating company to
• train staff,
• observe safety regulations,
• follow the instruction manual.
Operators must
• have been trained,
• have read and understood all relevant sections of the instruction manual before
commencing work,
• know the safety mechanisms and regulations.
To avoid personal injury and loss of property, do not install, operate, maintain or service
this instrument before reading and understanding this instruction manual and receiving
appropriate training.
ADDITIONAL LITERATURE
This manual covers aspects important for installation and startup of X-STREAM XE gas
analyzers.
For comprehensive information on operating and maintain/service the instrument in a
safe manner it is MANDATORY to read all additional instruction manuals, if not provided
as printed version, see the accompanying CD-ROM for an electronic version (PDF)!
The following additional instruction manuals are available or referenced within this manual:
HASXEE-IM-HS X-STREAM XE series instruction manual
HASICx-IM-H Infallible containment instruction manual
Contact your local service center or sales ofce when missing documents.
SAVE ALL INSTRUCTIONS FOR FUTURE USE!
Emerson Process Management GmbH & Co. OHGS-6
Short Form Manual
HASXEE-SFM-HS
04/2010
X-STREAM XE
Safety Instructions
OPERATING AND MAINTAINING THIS UNIT
On leaving our factory, this instrument conformed to all applicable safety directives.
In order to preserve this state of affairs, the
operator must take care to follow all the instructions and notes given in this manual and
on the unit.
Before switching on the unit, ensure that the
local nominal mains voltage corresponds to
the factory-set operational voltage of this
unit.
Any interruption of the protective earth connections, whether inside or outside of the unit,
may result in exposure to the risk of electricity.
Deliberately disconnected the protective earth
is therefore strictly forbidden.
Removing covers may expose components
conducting electric current. Connectors may
also be energised. The unit should therefore
be disconnected from the power supply before
any kind of maintenance, repair or calibration
work requiring access to the inside of the
unit.
Only trained personnel who are aware of
the risk involved may work on an open and
energized unit.
Fuses may only be replaced by fuses of an
identical type and with identical ratings. It is
forbidden to use repair fuses or to bypass
fuses.
Take note of all applicable regulations when
using this unit with an autotransformer or a
variable transformer.
Substances hazardous to health may escape
from the unit’s gas outlet. This may require
additional steps to be taken to guarantee the
safety of operating staff.
Safety Instructions
S
Emerson Process Management GmbH & Co. OHG S-7
X-STREAM XE
The units described in this manual may not be used in explosive atmospheres
without additional safety measures.
Do not operate without covers secure.
Short Form Manual
HASXEE-SFM-HS
04/2010
Safety Instructions
EXPLOSION HAZARD
ELECTRICAL SHOCK HAZARD
Do not open while energized.
Installation requires access to live parts which can cause death or serious
injury.
For safety and proper performace this instrument must be connected to a
properly grounded three-wire source of power.
TOXIC GASES
This unit’s exhaust may contain toxic gases such as (but not limited to)
e.g. sulfur dioxide. These gases can cause serious injuries.
Avoid inhaling exhaust gases.
Connect the exhaust pipe to a suitable ue and inspect the pipes regularly
for leaks.
All connections must be airtight to avoid leaks;
X-STREAM XE series
instruction manual on how performing a leak test.
Emerson Process Management GmbH & Co. OHGS-8
Short Form Manual
HASXEE-SFM-HS
04/2010
The models intended for outside and wall mounted use (X-STREAM XEF and
XDF) weigh between 25 kg (57 lb) and 45 kg (99 lb), depending on version
and options installed.
X-STREAM XE
Safety Instructions
HEAVY INSTRUMENT
Safety Instructions
Two people and/or lifting equipment is required to lift and carry these
units.
Take care to use anchors and bolts specied to be used for the weight of
the units!
Take care the wall or stand the unit is intended to be installed at is solid
and stable to support the weight!
CRUSHING HAZARD
Take care of crushing hazard when closing the front door of analyzer eld
housings!
Keep out of the closing area between enclosure cover and base!
OPERATION AT LOW TEMPERATURES
When operating an instrument at temperatures below 0 °C (32 °F), do
NOT apply gas nor operate the internal pump before the warmup time has
elapsed!
S
Violation may result in condensation inside the gas paths or damaged
pump diaphragm!
HIGH TEMPERATURES
Hot parts may be exposed when working on photometers and/or
heated components in the unit.
Emerson Process Management GmbH & Co. OHG S-9
X-STREAM XE
Safety Instructions
GASES AND PREPARATION OF GASES
GASES HAZARDOUS TO HEALTH
Follow the safety precautions for all gases (sample and span gases) and
gas cylinders.
Before opening the gas lines, they must be purged with air or neutral gas (N2)
to avoid hazards from escaping toxic, ammable, explosive or hazardous
gases.
Short Form Manual
HASXEE-SFM-HS
04/2010
FLAMMABLE OR EXPLOSIVE GASES
When supplying explosive gases or ammable gases with concentrations of
more than 25 % of the lower explosion limit, we RECOMMEND implementing
one or more additional safety measures:
• purging the unit with inert gas
• stainless steel internal pipes
• ame arrestors on gas inlets and outlets
• infallible measuring cells.
Emerson Process Management GmbH & Co. OHGS-10
Short Form Manual
HASXEE-SFM-HS
04/2010
POWER SUPPLY
X-STREAM XE
Safety Instructions
CONNECTING UNITS FOR PERMANENT INSTALLATION
Only qualied personnel following all applicable and legal regulations may
install the unit and connect it to power and signal cables. Failure to comply
may invalidate the unit’s warranty and cause exposure to the risk of damage,
injury or death.
This unit may only be installed by qualied personnel familiar with the
possible risks.
Working on units equipped with screw-type terminals for electrical
connections may require the exposure of energized components.
Wall-mounted units have no power switch and are operational when
connected to a power supply. The operating company is therefore required
to have a power switch or circuit breaker (as per IEC 60947-1/-3) available
on the premises. This must be installed near the unit, easily accessible to
operators and labelled as a power cut-off for the analyzer.
HAZARD FROM WRONG SUPPLY VOLTAGE
Ensure that the local power voltage where the unit is to be installed,
corresponds to the unit’s nominal voltage as given on the name plate
label.
Safety Instructions
S
ADDITIONAL NOTES FOR UNITS WITH SCREW-TYPE TERMINALS
Cables for external data processing must be double-insulated against mains
power.
If this is not possible, cables must be laid in such a way as to guarantee
a clearance of at least 5 mm from power cables. This clearance must be
permanently secured (e.g. with cable ties).
Emerson Process Management GmbH & Co. OHG S-11
Short Form Manual
X-STREAM XE
HASXEE-SFM-HS
04/2010
General Operating Notes
GENERAL OPERATING NOTES
EXPLOSION HAZARD BY EXHAUST GASES
Exhaust gases may contain hydrocarbons, other toxic gases or even
explosive gases.
Faulty gas connections may lead to explosion and death.
Ensure that all gas connections are connected as labelled and airtight.
• The unit must be installed in a clean and dry area, protected from strong vibrations and
frost
.
• The unit must not be exposed to direct sunlight and sources of heat. Admissible ambient
temperatures (see technical details) must be adhered to.
• Gas inlets and outlets must not be interchanged.All gases must be conditioned, before supplied to the unit. When using this unit with corrosive sample gases, ensure that these gases
do not contain components harmful to the gas lines.
• Admissible gas pressure for sample and test gases is 1,500 hPa.
• Exhaust lines must be laid inclined downwards, depressurized, protected from frost and
according to applicable regulations.
• If it is necessary to disconnect the gas lines, the unit’s gas connectors must be sealed with
PVC caps to avoid polluting the internal gas lines with condensate, dust, etc.
• To ensure electromagnetic compatibility (EMC), only shielded cables (supplied by us on request, or of equivalent standard) may be used. The customer must ensure that the shielding
is correctly tted. Shielding and terminal housing must be electrically connected; submin-D
plugs and sockets must be screwed to the unit.
• When using optional external adapters (submin-D to screw-type terminals), protection against
electromagnetic interference is not ensured (CE compliance pursuant to EMC guidelines).
In this case the customer or operating company functions as a system builder and must
therefore ensure and declare compliance with EMC guidelines.
Emerson Process Management GmbH & Co. OHGS-12
Short Form Manual
HASXEE-SFM-HS
04/2010
Chapter 1
Technical description
The following are the main features of the new
Emerson Process Management X-STREAM
XE series gas analyzers in brief:
• compact design with easily accessible
internal components
• customizable for a wide range of applications: different housings are available
while internal construction remains largely
identical
• a highly integrated mainboard contains
all interfaces and basic functions for the
operation of the unit
• multilingual microprocessor-controlled
user interface with liquid crystal (LCD) to
indicate measurement value and status
messages
• units for outdoor use are optionally supplied with an impact tested front panel
• widerange power supply unit for worldwide
use without modication (1⁄2 19in units with
external PSUs)
The new X-STREAM XE gas analyzers can
measure up to ve different gas components using any combination of the following
analyzing techniques (restrictions apply to
lable for use with corrosive gases and/or
gases containing solvents.
Special congurations (e.g. intrinsically safe
or infallible measuring cells) for the analysis
of combustible gases are also available.
Standard applications
Different housings allow X-STREAM XE
analyzers to be tailored to the many different
applications:
• Tabletop units in 1⁄2 19in modular design,
• Tabletop and rackmountable units in 19in
• Stainless steel wallmountable eld housing
• Cast aluminium wallmountable field
The various analyzer types are described in
more detail beginning with 1-3.
electrochemical oxygen analysis
with IP 20 protection class
modular design, with IP 20 protection
class
with IP 66 / NEMA 4X protection class
for outdoor use (operating temperature
0 (-20) °C to +50°C).
housing with IP 66 / NEMA 4X protection
class for outdoor use (operating temperature 0 (-20) °C to +50 °C).
Techn. Description
1
EXPLOSION HAZARD
X-STREAM XE analyzers CAN NOT be used in explosive environments
(hazardous areas) without additional safety features.
This instruction manual does NOT describe the special conditions necessary
to operate gas analyzers in hazardous areas.
Please refer to the separate instruction manual, supplied with units for use
in hazardous areas.
Emerson Process Management GmbH & Co. OHG 1-1
X-STREAM XE
1.1 Overview
Short Form Manual
HASXEE-SFM-HS
04/2010
1.1 Overview
All X-STREAM gas analyzers feature an
easy-to-use graphical user interface, which
displays measurement values, status and
error messages, and menus for the input of
parameters.
For ease of use, the operator can select one
of three languages for the display: By default
any analyzer is congured with English and
1.1.1 The Front Panel
The graphic LCD shows measurement and
status information with plain text and symbols.
The symbols are designed to indicate the different status “Failure”, “Function check”, “Out
of specication” and “Maintenance request” as
specied by the NE 107 standard. For further
information,
X-STREAM XE instruction
manual.
German language sets, while a third can
optionally be added. Currently available:
French, Italian, Portuguese and Spanish..
The analyzer software is operated by means
of only six keys.
Depending on the analyzer model, the display
can also be protected with an impact tested
glass panel, to withstand even harsher conditions and to provide a higher IP protection class
of up to IP66 / NEMA Type 4X.
1342
1 Graphic display
2 “Measure“ key
3 “Enter” key
4 4 keys for settings and menu navigation
Fig. 1-1: X-STREAM front panel (here the X-STREAM XEGP)
Emerson Process Management GmbH & Co. OHG1-2
X-STREAM XE
1.2 Comparison of Analyzer Models
1.2 Comparison of the Various X-STREAM Analyzer Model
Short Form Manual
HASXEE-SFM-HS
04/2010
X-STREAM XEGC
1
⁄2 19 in housing, table-top or rackmountable,
protection type: IP 20
1
⁄1 19 in housing, table-top or rackmountable,
protection type: IP 20
X-STREAM XEGP
24V input with external power supply unitInternal wide range power supply unitInternal wide range power supply unitInternal wide range power supply unit
Max. 3 channels: 2 photometer + 1 WLD/O
2
max. 6 gas connections,
including 1 optional purge gas connection
Options for gas lines: Flow sensor, pressure
sensor, infallible gas lines
Max. 4 channels in any combination
max. 8 gas connections,
1 optional extra connection for purge gas
Options for gas lines: Flow sensor, pressu-
re sensor, heating for physical components,
sample gas pump, 1 or 2 valve blocks, infallible gas lines
1-4 analog outputs, 4 relay outputs, 2 Modbus
Ethernet interfaces, 2 USB connectors
optional:
1 interface card with 7 digital inputs and
9 digital outputs
1 interface card with analog inputs
electrical interfaces accessible via sockets on
back of unit, optionally: screw-type terminal
adapters
(except for Ethernet & USB)
1-4 analog outputs, 4 relay outputs, 2 Modbus
Ethernet interfaces, 2 USB connectors
optional:
1 or 2 interface cards, each with 7 digital
inputs and 9 digital outputs
1 interface card with analog inputs
electrical interfaces accessible via sockets on
back of unit, optionally: screw-type terminal
adapters
(except for Ethernet & USB)
LCDLCDLCD, impact tested front panelLCD, impact tested front panel
Operating ambient temperature:
0 °C to +50 °C (32 °F to 122 °F)
Operating ambient temperature:
0 °C to +50 °C (32 °F to 122 °F)
Size: (DxHxW): max. ca. 440x130x220 mm
Weight: ca. 8 - 12 kg (17.6 - 26.5 lb)
Size: (DxHxW): max. ca. 411x133x482 mm
Weight: ca. 11 - 16 kg (24.3 - 35.3 lb)
Max. 4 channels in any combination
max. 8 gas connections,
1 optional extra connection for purge gas
Options for gas lines: Flow sensor, pressure
sensor, heating for physical components,
sample gas pump, 1 or 2 valve blocks, infallible gas lines
1-4 analog outputs, 4 relay outputs, 2 Modbus
Ethernet interfaces, 2 USB connectors
optional:
1 or 2 interface cards, each with 7 digital
inputs and 9 digital outputs
1 interface card with analog inputs
electrical interfaces on internal screw-type terminal adapters
Operating ambient temperature:
-20 °C to +50 °C (-4 °F to 122 °F)
Models available for use in explosive environ-
ments
Size: (DxHxW): ca. 265x400 (815)x550 mm
Weight: max. ca. 25 (45) kg / 55.1 (99.2) lb
(except for Ethernet & USB)
Max. 4 channels in any combination
max. 8 gas connections,
including 2 optional purge gas connection
Options for gas lines: Flow sensor, pressu-
re sensor, heating for physical components,
sample gas pump, 1 or 2 valve blocks, infallible gas lines
1-4 analog outputs, 4 relay outputs, 2 Modbus
Ethernet interfaces, 2 USB connectors
optional:
1 or 2 interface cards, each with 7 digital
inputs and 9 digital outputs
1 interface card with analog inputs
electrical interfaces on internal screw-type terminal adapters
Operating ambient temperature:
-20 °C to +50 °C (-4 °F to 122 °F)
Flameproof enclosure: approved for use in
explosive environments
Size: (DxHxW): max. ca. 222x512x578 mm
Weight: max. ca. 63 kg (138.9 lb)
This model is not covered by this manual!
See the separate X-STREAM Ex d manual
for hazardous area applications!
(except for Ethernet & USB)
Emerson Process Management GmbH & Co. OHG 1-4
Short Form Manual
HASXEE-SFM-HS
04/2010
1.3 X-STREAM XEGC
1.3 X-STREAM XEGC: ½ 19 Inch Table-Top Unit
X-STREAM XE
This compact model for general purposes
can be tted with up to three photometer
measurement channels (IR or UV) and one
additional non-photometer channel (eO
, pO2
2
or WLD). Power is supplied by a separate
external power supply unit.
By default the units are congured for tabletop
use. For rack mounting an accessory kit can
be ordered to either install 2 units alongside,
or one single unit together with a blind plate.
Connection to power supply
DC 24 V power is supplied via a 3-pin socket
at the rear of the unit.
Interfaces
Electrical connections for interface signals are
provided via submin-D connectors, Ethernet
and USB connectors mounted on the rear
panel of the device
(g. 1-5).
For applications where screw-type terminals
are preferred, optional adapters are available,
which are mounted directly onto the submin-D
connectors.
Techn. Description
1
134562
1 Status line
2 Graphic display
3 Messages line
4 home key
5 enter key
6 4 keys for adjustment and menu selection
Fig. 1-2: X-STREAM XEGC
Emerson Process Management GmbH & Co. OHG 1-5
7 Signal connectors (some optional)
8 Gas ttings
9 Power input fuse
10 Power input connector
78910
X-STREAM XE
1.4 X-STREAM XEGP
1.4 X-STREAM XEGP: 19 Inch Table-Top Or Rackmount Design
Short Form Manual
HASXEE-SFM-HS
04/2010
This model can be fitted with up to four
measurement channels in any combination.
The physical components can optionally be
encased in a cover. This area can be held at
a specic temperature of up to 60 °C to minimize interference from changes in external
temperature.
Units congured for rack mounting can be
converted for tabletop use by removing the
lateral mounting brackets and attaching the
four feet supplied as accessories.
Front view
Connection to power supply
Main power is supplied via the IEC chassis
plug mounted on the rear panel, with integrated power switch and fuse holders. The
internal wide range power supply unit enables
the analyzers to be used worldwide.
Adaptors are optionally available for signal
connections, to provide screw terminals instead of submin-d-connectors (
1-7).
134562
1 Status line
2 Graphic display
3 Messages line
Rear view
1 Gas connector ttings
2 Space for additional ttings
3 Optional purge gas inlet
Fig. 1-3: X-STREAM XEGP
4 home key
5 enter key
6 4 keys for adjustment and menu selection
15243
4 Power inlet with lter, fuses & switch
5 Signal input/output connectors (some optional)
Emerson Process Management GmbH & Co. OHG1-6
Short Form Manual
HASXEE-SFM-HS
04/2010
X-STREAM XE
1.4 X-STREAM XEGP
Strain-reliefs, top view details
Techn. Description
1
1
1
Fig. 1-4: Optional screw-type terminal adapters
2
1 Screw-type terminal adapters
2 Strain-reliefs
Emerson Process Management GmbH & Co. OHG 1-7
Short Form Manual
X-STREAM XE
1.5 X-STREAM XE Field Housing
1.5 X-STREAM XEF/XDF: Field Housing With Single Or Dual Compartment
HASXEE-SFM-HS
04/2010
The eld housing model is conceived for
outdoor use and wall-mounting. The coated stainless steel housing has a protection
class rated IP66 / NEMA Type 4X, offering
protection against water and dust entering
the device:
IPx6: Water projected in powerful jets against
the enclosure from any directions shall have
no harmful effects
IP6x: Protection against penetration by dust.
Live or internal moving parts are completely
protected.
X-STREAM eld housings can be tted with
up to four measurement channels in any combination. The physical components can optionally be encased in a cover. This separate
volume can be held at a specic temperature
of up to 60 °C to minimize interference from
changes in external temperature.
Front panel
The analyzer ’s display can o
ptionally be
protected by an impact tested glass for enhanced protection against breakage in harsh
environments.
Connection to power supply
Mains power is supplied via screw-type terminals with integrated fuse holders at the right
of the housing, near the front. The wide range
power supply unit mounted internally enables
the analyzers to be used worldwide.
134562
1 Status line
2 Graphic display
3 Messages line
4 home key
5 enter key
6 4 keys for adjustment
and menu selection
Fig. 1-5: X-STREAM XEF / XDF- Front views
Emerson Process Management GmbH & Co. OHG1-8
Short Form Manual
HASXEE-SFM-HS
04/2010
X-STREAM XE
1.5 X-STREAM XE Field Housing
Techn. Description
1
213
1 Cable gland for power cable
2 Cable glands for signal cables
3 4 brackets for wall-mounting
4 Gas in- & outlets (max. 8)
5 Cutouts, to combine 2 housings (here closed)
Fig. 1-6: X-STREAM XEF - right side and bottom view
HEAVY INSTRUMENT
The X-STREAM eld housing, intended for outside and wall mounted use,
weighs approx. 26 kg/57 lb (XEF) or 45 kg/99 lb (XDF), depending on options
installed.
Two people and/or lifting equipment is required to lift and carry these units.
Take care to use anchors and bolts specied to be used for the weight of
the units!
545
Note!
In case of XDF, the cable glands are located
at the upper compartment, while the gas in& outlets are at the bottom side of the lower
compartment.
Also only 2 brackets are at each compartment.
Take care the wall or stand the unit is intended to be installed at is solid
and stable to support the weight!
Emerson Process Management GmbH & Co. OHG 1-9
X-STREAM XE
Short Form Manual
HASXEE-SFM-HS
04/2010
1.7 X-STREAM XE Field Housing
13245
(shown with front
panel removed)
1 Screw-type terminals for signal cables
2 Power line lter
3 Cable glands
4 Power supply terminals with integrated fuses
5 Ethernet and USB connectors
Fig. 1-7: X-STREAM XEF - power supply and signal terminals
Note!
In case of XDF, the terminals and
connectors are located at the upper
compartment, while physical components and gas ttings are in the lower
compartment.
Emerson Process Management GmbH & Co. OHG1-10