Step 3: Connecting the Transmitter Head . . . . . . . . . . . . page S-11
This instruction is a supplement to the Rosemount 5300 Series Reference
Manual (Document No. 00809-0100-4530) and to the Rosemount 5400
Series Reference Manual (Document No. 00809-0100-4026).
www.rosemount.com
Instruction Manual Supplement
00809-0600-4530, Rev AB
Rosemount 5300/5400 Series
November 2011
SAFETY MESSAGESProcedures and instructions in this section may require special precautions to
ensure the safety of the personnel performing the operations. Information that
raises potential safety issues is indicated by a warning symbol (). Refer to the
following safety messages before performing an operation preceded by this
symbol.
Failure to follow these installation guidelines could result in death or serious injury
• Make sure only qualified personnel perform the installation.
• Use the equipment only as specified in this manual. Failure to do so may impair
the protection provided by the equipment.
Explosions could result in death or serious injury
• Verify that the operating environment of the transmitter is consistent with the
appropriate hazardous locations specifications.
• Before connecting a HART
make sure the instruments in the loop are installed in accordance with intrinsically
safe or non-incendive field wiring practices.
• To prevent ignition of flammable or combustible atmospheres, disconnect power
before servicing.
Electrical shock can result in death or serious injury
• Use extreme caution when making contact with the leads and terminals.
• Make sure the main power to the Rosemount 5300 Series transmitter or
Rosemount 5400 Series transmitter is off and the lines to any other external
power source are disconnected or not powered while wiring the transmitter.
®
-based communicator in an explosive atmosphere,
Any substitution of non-authorized parts or repair, other than exchanging the complete
transmitter head or probe assembly, may jeopardize safety and is prohibited.
Unauthorized changes to the product are strictly prohibited as they may unintentionally and
unpredictably alter performance and jeopardize safety. Unauthorized changes that interfere
with the integrity of the welds or flanges, such as making additional perforations,
compromise product integrity and safety. Equipment ratings and certifications are no longer
valid on any products that have been damaged or modified without the prior written
permission of Emerson Process Management. Any continued use of product that has been
damaged or modified without the written authorization is at the customer’s sole risk and
expense.
S-2
Instruction Manual Supplement
00809-0600-4530, Rev AB
November 2011
Rosemount 5300/5400 Series
INTRODUCTIONThis document describes the installation procedure of a HART to Modbus
Converter (HMC) when using with Rosemount 5300/5400 transmitters.
To upgrade the Rosemount 5300 or 5400 Series transmitters, use the
modification kit together with the tools detailed below.
The Modification KitThe modification kit consists of the following parts:
•Terminal Block
•120Ω Termination Resistor
•CSA Bracket for Grounding - only included in Modification Kit for
transmitters with CSA approval (Model Code E6)
•Spare Kit Modbus Label
•IS Ground Label
•Spare Part Kit Instruction
•HART to Modbus Manual Supplement
Figure S-1. Parts of the
Modification Kit
NOTE!
Before starting to upgrade the transmitter to use with Modbus, make sure the
transmitter head you are upgrading is eligible for the Modbus upgrade.
Transmitters with the following certificates are allowed to be upgraded to Modbus:
•transmitters with FM or CSA approval (Model Code E5 or E6)
•transmitters with no hazardous location certificates (Model Code NA)
Transmitters which cannot be upgraded to Modbus:
•transmitters with other type of approvals (for example, Intrinsic Safety
Approval). Model Codes: E1, E3, E7, I1, IA, I3, IC, I5, IE, I6, IF, I7, IG, KA,
KB, KC, KD, KE, KF, KG, KH, KI, KJ, KK, KL.
•transmitters containing Special Certifications with model code QS (Prior
Use Certificate of FMEDA)
•transmitters containing Special Certifications with model code U1 (WHG
Approval)
S-3
Rosemount 5300/5400 Series
The model code is visible on the main label attached to the transmitter head. See
Figure S-2.
Figure S-2. Model Code on the
Main Label
Instruction Manual Supplement
00809-0600-4530, Rev AB
November 2011
The model code describes what options were included when the transmitter was
ordered originally.
To find out if the transmitter is eligible for Modbus upgrade, look for E5, E6, or NA
combination in the model code.
This letter/number combination is normally found at the end of the model code.
ExampleModel Code 1
5301HA1S1V4AE00500AARAE5M1Q4
This model code contains E5 (FM approval) and is eligible for upgrade to Modbus.
Model Code 2
5301HA1S1V4AE00470AARAI6M1BRQ4
This model code contains I6 (CSA Intrinsic Safety approval) and is not eligible
for upgrade to Modbus.
Model Code 3
5301HA1S1V4AE00470AARAE5M1QS
This transmitter contains the E5 code (FM approval) and the QS code also (Prior
Use Certificate of FMEDA) and is therefore not eligible for Modbus Upgrade.
S-4
If unsure whether your transmitter can be upgraded to Modbus, contact your local
Rosemount Level Specialist for more information.