1. Introduction
This instruction describes the installation of a Ø139 mm (5 “) insertion pipe into a 8-inch Still pipe with a Still-Pipe Gauge Rosemount 5900 system.
For more information see drawing 9240 041-930. After mounting the insertion pipe according to these instructions, see Rosemount 5900 Reference Manual.
2. Included parts
Adapter 5” / 8”, 9150076-515 Ø139 mm (5 “) Pipe Extension, length 3m, 9150 076-065 Ø139 mm (5 “) Pipe Bottom, length 3m, 9150 076-066
Coupling pipe, 9150 076-060 Bracket pipe, 9150 076-061 Ø5 mm (3/16 in) Stainless steel Rivet (customer supply) Rope, length > 40m (130 ft) (customer supply) Wire (customer supply)
Please refer to the mechanical installation drawings for more information on the installation requirements.
3. Safety
The installation is often performed in areas where flammable materials are handled or in an explosive atmosphere. Follow the local safety regulations. Use only tools manufactured for hazardous areas. See Rosemount 5900 Reference Manual for further information on safety issues regarding the Rosemount 5900 tank gauging system.
Ritningsblankett med makro.dot
The copyright/ownership of this document is and will remain ours. The document must not be used without our authorization or brought to the knowledge of a third party. Contravention will be prosecuted.
Rosemount Tank Radar AB
DOC NO.
PAGE
9261 035-040
1
2/5
4. Preparations
Before the installation start, following preparations must be made:
• If possible check that the still pipe is empty and remove any obstructive objects.
• Make sure the still pipe is vertical within 0.3° (0.1 m over 20 m).
• Arrange for a fixed point, for example a crane or a tripod, approximately 3.5 meters (10 ft) above
the still pipe nozzle. Attach a tackle to facilitate lowering the insertion pipes into the still pipe.
-----------------------------------------------------------------------------------------------------------------------­ Note! The total weight of the pipes will be 75-150 kg depending on how many pipes used.
Each pipe weighs approximately 25 kg.
-------------------------------------------------------------------------------------------------------------------------
• Measure the height of the still pipe. Add 200 mm (~8”) and cut the top pipe to a proper length.
• Mark a centre line along all insertion pipes to make it possible to vertically align the pipes.
Figure 1. Bottom pipe with Wire ring and Bottom pipe legs
• Slip a wire through the wire ring on the lower part of the bottom pipe. The wire is used for inserting the temperature sensors into the still pipe.
• Hang the middle of a rope with a length extending 40 meter (130 ft) between the legs on the bottom pipe. Do not attach the rope to any of the legs.