This guide provides instructions for installing the Rosemount 326, 327, and 1408 transmitters with G1 process connectors using a weld-in adapter (part number FB-1041).

1.1 Safety instructions

Follow these guidelines to ensure safe use and extend the life of the product.
CAUTION
Read this document before using the product and keep it during
the entire service life.
The product must be suitable for the corresponding applications
and environmental conditions without any restrictions.
Only use the product for its intended purpose.
If the operating instructions or the technical data are not adhered
to, personal injury and/or damage to property might occur.
The manufacturer assumes no liability or warranty for any
consequences caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and
maintenance of the product must be carried out by qualified personnel.

1.2 Hygienic adapter O-ring

The adapter comes with an EPDM O-ring. More O-rings are available as accessories. See each product's Product Data Sheet for more information.
2

2 Install the weld-in adapter

Use the weld-in adapter to install transmitters with G1 process connections to containers or pipes.
Prerequisites
After welding, allow the adapter to cool before installing. Do not weld the adapter to the container or pipe with the transmitter connected.
Procedure
Bore a hole that has the outside diameter of the adapter in the
1. pipe or container wall.
Maximum oversize: 0.008 in (0.2 mm)
Weld the adapter.
2.
Note
While welding, prevent the adapter from warping.
a) Turn the marking (1) (marking may vary) to the
position shown below for the display of the screwed transmitter.
3
b) Fix the adapter in several spots with a sufficient
adhesive force. Apply the fixing points at equal distances opposite
each other.
c) Apply the welding seams between the fixing points
opposite each other. Ensure sufficient and even distance between the
individual sections to avoid glowing through or warping of the adapter caused by overheating.
3. Allow the adapter to cool.
4. If used, remove the welding mandrel.
5.
Remove deposits from the thread.
4

3 Mount the transmitter

326P
1408
326L
327T
Follow these steps to mount the transmitter to a container or pipe using the weld-in adapter.
Procedure
Remove the transmitter from the protective packaging.
1.
If needed, clean the sealing areas.
2.
3. Place the O-ring in the groove of the transmitter.
Note
Be careful not to scratch or damage the surfaces of the transmitter.
4. Grease the transmitter thread with lubricating paste.
Note
The paste must be approved for the application and compatible with the elastomers used.
5
5. Tighten the transmitter to the recommended torque.
34 mm / 39 mm
Torque 310 in-lb (35 N-m)
Note
Over tightening the transmitter can impair the seal. If the sealing areas are damaged, replace the O-ring or the entire process connector.
6

4 Product certifications

4.1 3-A® certification

This product is authorized to display the 3-A symbol. Ensure gaskets and process connection accessories selected for installation meet both the application and 3-A requirements. A certificate of compliance is available at

4.2 Other industry certifications

All connector surfaces and materials which come into contact with process medium comply with the following regulations:
(EC) No. 1935/2004
(EC) No. 2023/2006
CFR Title 21 (FDA) § 177.2600
CFR Title 21 (FDA) § 177. 2415
Emerson.com/Rosemount.
7
*00825-0100-4104*
Quick Start Guide
00825-0100-4104, Rev. 02
August 2020
Emerson Automation Solutions
6021 Innovation Blvd. Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
RFQ.RMD-RCC@Emerson.com
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
©
2020 Emerson. All rights reserved.
Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.
North America Regional Office
Emerson Automation Solutions 8200 Market Blvd. Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
RMT-NA.RCCRFQ@Emerson.com
Loading...