This guide provides instructions for installing a hygienic process
connection adapter on Rosemount 326, 327, and 1408 transmitters
with G1 process connectors. The following adapters are covered by
this guide:
Table 1-1: Hygienic Process Connection Adapters
Part numberDescription
FB-10011½-in. Tri Clamp (ISO 2852 / DIN 32676)
FB-10022-in. Tri Clamp (ISO 2852 / DIN 32676)
FB-1010VARIVENT® Type F
FB-1011VARIVENT Type N
FB-1020DN32 Dairy Coupling (DIN 11851)
FB-1021DN40 Dairy Coupling (DIN 11851)
FB-1022DN50 Dairy Coupling (DIN 11851)
2
1.1 Safety instructions
Follow these guidelines to ensure safe use and extend the life of the
product.
CAUTION
• Read this document before using the product and keep it during
the entire service life.
• The product must be suitable for the corresponding applications
and environmental conditions without any restrictions.
• Only use the product for its intended purpose.
• If the operating instructions or the technical data are not adhered
to, personal injury and/or damage to property might occur.
• The manufacturer assumes no liability or warranty for any
consequences caused by tampering with the product or incorrect
use by the operator.
• Installation, electrical connection, set-up, operation and
maintenance of the product must be carried out by qualified
personnel.
1.2 Hygienic adapter O-ring
The adapter comes with an EPDM O-ring. More O-rings are available
as accessories. See each product's Product Data Sheet for more
information.
3
2 Install the adapter
326P
1408
326L
327T
Prerequisites
Use a new adapter when replacing a PEEK sealing ring or changing
from a PEEK seal to O-ring sealing.
Procedure
Place the O-ring in the groove of the transmitter.
1.
Note
Be careful not to scratch or damage the surfaces of the
transmitter.
2. Grease the transmitter thread with lubricating paste.
Note
The paste must be approved for the application and
compatible with the elastomers used.
4
3. (Only for DIN 11851) Slide the coupling nut up over the
bottom of the transmitter.
4. Screw the adapter onto the transmitter until it is hand-tight.
5. Secure the transmitter and adapter using a vise.
CAUTION
Do not over-tighten the vise as it might damage the adapter.
5
6. Tighten the transmitter to the recommended torque.
34 mm / 39 mm
Torque 310 in-lb (35 N-m)
Note
Further tightening may affect the sealing effect.
6
3 Mount the transmitter
Procedure
Mount the transmitter and adapter assembly using a fixing element
(coupling nut or clamp flange).
7
4 Product certifications
4.1 3-A® certification
FB-1001, FB-1002, FB-1010, and FB-1011 are authorized to display the
3-A symbol. Ensure gaskets and any other accessories selected for
installation meet both the application and 3-A requirements. A
certificate of compliance is available at
4.2 Other industry certifications
All connector surfaces and materials which come into contact with
process medium comply with the following regulations:
Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a
trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the
Emerson family of companies. All other marks are the property of their respective owners.
North America Regional Office
Emerson Automation Solutions
8200 Market Blvd.
Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
RMT-NA.RCCRFQ@Emerson.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.