Rosemount Emerson Plantweb Insight Quick Start Guide

Page 1
Emerson Plantweb™ Insight
Quick Start Guide
00825-0100-4541, Rev DE
March 2020
Page 2
Quick Start Guide March 2020
Contents
Overview......................................................................................................................................3
System requirements................................................................................................................... 4
Installation................................................................................................................................... 6
Launching the application............................................................................................................ 9
Customize system settings.........................................................................................................10
Application installation...............................................................................................................13
Application configuration...........................................................................................................14
2 Emerson.com/Rosemount
Page 3
March 2020 Quick Start Guide
Thank you for choosing Plantweb Insight. This document guides you through initial set up of the software platform. For more details and configuration information on specific applications, refer to the Plantweb Insight Reference Manual.
Before installing Plantweb Insight be sure you have one of the required virtualization software/hypervisor set up and running correctly. Compatible virtualization softwares/hypervisors are listed in the System requirements section of this document.
Quick Start Guide 3
Page 4
Quick Start Guide March 2020

2 System requirements

Plantweb Insight is delivered as a fully developed virtual machine (e.g. .ova file). Users will receive a complete virtual machine image to install in user provided virtualization software or hypervisors.
The Plantweb Insight virtual machine contains a web server that can be accessed by any web client with network access. All configuration and visualization will be completed from the web browser user interface.
Plantweb Insight can be installed on a network server or PC/laptop. Both installations have the same requirements and installation steps. Network connection settings can be made subject to organization policies. Any pertinent Gateways must be accessible on the network.
Before you begin, verify your system meets the minimum requirements.

2.1 Host operating system

Virtualization software/hypervisor
VMware Workstation Pro™ 10 or higher (requirements can be found
here)
VMware vSphere® 5.5 or higher (requirements can be found here)
OR
Contact Rosemount™ support if utilizing a different virtualization
software (Microsoft® Hyper-V®)
2.2
2.3
4 Emerson.com/Rosemount

Guest operating system

Processors = 4
Memory = 16 GB RAM minimum
Hard drive = 100 GB of free space

Application

Browsers (recent versions supported)
Chrome™ browser
Microsoft Internet Explorer
®
Page 5
March 2020 Quick Start Guide

2.4 Other requirements

A DVD drive is required for installations
A DHCP server is required to assign a valid IP address (static IP address
can be configured once connected to the Plantweb Insight web interface)

2.5 Gateway compatibility

Plantweb Insight is compatible with Emerson Wireless 1410/1420 Gateways on firmware version 4.7.68 or higher. Plantweb Insight may experience calculation response issues on certain applications when Gateway firmware is not up to date. These may effect the Pump, Heat Exchanger, Air Cooled Heat Exchanger, and Pressure Relief Device applications.

2.6 Device compatibility

Emerson devices must be in Emerson Optimized burst configuration. If devices are not set to this, change using a device configuration tool.
Devices without this capability must be in either of the two configuration modes to be compatible with Plantweb Insight:
command 9 and command 48
command 3 and command 48
Quick Start Guide 5
Page 6
Quick Start Guide March 2020

3 Installation

Two DVDs will be supplied for installations.
Procedure
1. Exit/close all programs, including any running in the background.
2. Insert Disk 1 into the DVD drive.
3. Open the ova file. This file will prompt VMware workstation/vSphere to open with an Import Virtual Machine pop-up.
Note
This file name may change based on version and type.
4. Name and store the new virtual machine, then select Import.
5. If the following message appears, select Retry.
6. Wait for the virtual machine to load.
6 Emerson.com/Rosemount
Page 7
March 2020 Quick Start Guide
7. Select Power on this virtual machine once the loading process is complete.
8. Find the IP address in the command window.
Note
This IP address will vary depending on installation. What is shown here will not be your IP address.
Note
A DHCP server will be required to assign an IP address. If no DHCP server is available please contact Rosemount support (contact information on last page).
Note
The virtual machine login and password are not necessary and will not be provided.
Note
A message about features may pop up during the installation process; select OK.
Quick Start Guide 7
Page 8
Quick Start Guide March 2020
CAUTION
End users should not change any settings except those outlined above. Alterations could impact the performance and functionality of Plantweb Insight.
8 Emerson.com/Rosemount
Page 9
March 2020 Quick Start Guide

4 Launching the application

The Plantweb Insight web interface can be launched from any of the supported web browsers shown in the system requirements.
Procedure
1. Open a supported web browser.
2. Input the IP address from Step 8 in the web browser. It is required to use https:// when entering the IP address.
3. Login with the following credentials:
Email: admin@emerson.com
Password: Default.1234
Note
Both the Email and Password are case sensitive.
4. Change your password as prompted. Default settings are listed below but can be changed in System Settings.
Minimum length: 12
Minimum lowercase: 1
Minimum uppercase: 1
Minimum numbers: 1
5. Login with the updated credentials.
Quick Start Guide 9
Page 10
Quick Start Guide March 2020

5 Customize system settings

System settings should be configured during the setup of Plantweb Insight.

5.1 Add/edit users

Procedure
1. Navigate to System Settings Users User Accounts then select the Add User Account button.
2. Enter the user’s Email, Role, and Password and select Save.
Table 5-1: Roles and Privileges
User role Privileges
Admin Read and write
User Read

5.2 Password options

Password requirements and settings can be made in the Password Option page. These settings include password limitations and requirements (e.g. uppercase letters, lowercase letters, numbers, characters), session idle timeouts, and account locking details.
5.3
5.4
10 Emerson.com/Rosemount

Connecting to Gateway

Procedure
1. Navigate to System Settings Data Sources Gateway Connections.
2. Select the Add Gateway button.
3. Enter the IP Address, Port, and Description and select Save.
Note
HART-IP™ Port 5094.
Ensure both HART-IP TCP and HART-IP UDP are enabled in the Gateway.

Connecting to an OPC UA® server

Procedure
1. Navigate to System Settings Data Sources OPC UA Server Connections.
Page 11
March 2020 Quick Start Guide
2. Select Add OPC UA Server button.
3. Enter the IP Address, Port, Tag, and Description and select Save.
Note
The OPC UA Port in Plantweb Insight is designated as 4880 (the OPC UA Server must be set up for this port). Plantweb Insight uses a opc.tcp:// connection to the OPC UA Server. Tag and Description are used for explanatory reasons only. The IP address field will only accept IP addresses and will not accept full URLs (it assumes the opc.tcp://). The OPC UA Server must be configured to security configuration “none”. The OPC UA Server must be configured for “allow anonymous login”.

5.5 Network configuration (optional)

Important
Use caution when making changes to IP network settings. If they are lost or improperly configured, it may be difficult to log into the application. Contact the network administrator for information on the proper IP network settings to apply.
Plantweb Insight contains two network interfaces. Only network interface 1 allows web client access. Network interface 1 will be associated to network adapter 1 of the virtual machine. Network interface 2 will be associated to network adapter 2 of the virtual machine. Network interface 2 is non­routable.
The second network adapter needs to be configured in VMware Workstation/vSphere to activate the functionality of the second network.
To change IP Network Settings:
Procedure
1. Navigate to System Settings Platform Settings Ethernet Communication.
2. To change network interface 1, select Static IP Address.
3. Enter the following:
Hostname
IP Address
Netmask
Gateway
4. To enable network interface 2, select the enable check box.
5. Select Static IP Address.
Quick Start Guide 11
Page 12
Quick Start Guide March 2020
6. Enter the following:
IP Address
Netmask
7. Select Save.

5.6 Backup system settings

After initial installation and configuration, a backup of system settings is recommended.
Procedure
1. Navigate to System Settings Platform Settings Backup and Restore.
2. Create a Passphrase and select Save Backup.
Note
Passphrase is required for restoring your system to these settings.
12 Emerson.com/Rosemount
Page 13
March 2020 Quick Start Guide

6 Application installation

Procedure
1. Insert Disk 2 into the DVD drive.
2. In the web interface navigate to System Settings Platform Settings Manage Applications.
3. Under the Install App section, select the Browse button.
4. Navigate to Disk 2 and select the pertinent .app file and select Open.
5. Select Install.
6. An action prompt will appear - select Restart Server if this is the last app to install. Otherwise, select Resume and repeat Step 3-Step 5 for subsequent apps.
7. Navigate to Home and the apps installed will appear.
Quick Start Guide 13
Page 14
Quick Start Guide March 2020

7 Application configuration

There are a few configuration steps that are consistent across specific Plantweb Insight applications. These are briefly discussed below. More information about configuration can be found in the Plantweb Insight
Reference Manual.
Note
All configuration mentioned below is specific to Plantweb Insight. Changes will not be communicated to the Gateway or devices.

7.1 Global settings

Each application contains specific global settings that should be set before any asset configuration. Global settings apply to all assets. These settings could include units used for inputs (e.g. inlet pressure units), units used for calculations (e.g. currency), or key performance indicators to be tracked on the dashboard (e.g. overall health index).

7.2 Adding assets

There are two ways to add assets. The options are discussed below.
Configuration of devices occurs during addition of assets.

7.2.1 Add an asset

Use this method to add a single asset.
Procedure
1. Navigate to the Asset Summary tab and select the Add an Asset button.
2. Complete all information on the New Asset modal window and select Save.
Note
Depending on the application, it will likely take a period of time for the calculations to begin processing.
Adding a measurement point
There are multiple ways to configure variables to certain assets. They are described below.
Procedure
1. Wireless Device from an Emerson Wireless Gateway.
Depending on the application, wireless devices can either be added using a drop-down list or a search function.
14 Emerson.com/Rosemount
Page 15
March 2020 Quick Start Guide
For applications requiring specific devices, the devices can be
added by selecting the appropriate device via a drop-down list. The drop-down list will contain all devices with the pertinent device type.
For applications with generic measurements (pressure,
temperature, flow, etc.) the wireless devices can be added using the following procedure.
a. Select Source: HART-IP
b. Begin to type the device tag. After a few characters, a
drop-down list of recognized devices will appear. Select the pertinent device.
c. Select the pertinent variable (ex: PV).
2. OPC-UA tags
OPC-UA tags can be set up for certain measurement points.
Select Source: OPC-UA
Select the pertinent OPC-UA server
Type in the complete path to the pertinent measurement point
(ex: Objects/Devices/OPC_Server1/3051S/PV)
a. Use forward slashes, "/", for path breaks.
b. The entire path is case sensitive.
3. Manual input
Manual inputs should be used sparingly for measurement points. They should only be considered for known consistent conditions (motor speed).
Quick Start Guide 15
Page 16
Quick Start Guide March 2020
Select Source: Manual
Type in the manual value
Select the pertinent units

7.2.2 Import asset config

Use this method to add/edit multiple assets at the same time.
Procedure
1. Navigate to the Asset Summary tab and select the Import Asset Config button.
2. Select Download asset configuration and download the csv file.
Note
If there are no assets configured, select the Empty File box.
3. Complete the csv file and save files.
Note
Data fields have strict requirements for entries; these can be found in Import Specs File.
4. Browse and upload the csv file via the Import Asset Config modal window and select Save.
5. Check all assets were successfully downloaded.
6. If assets fail download, check all fields are filled out correctly and download again.
16 Emerson.com/Rosemount
Page 17
March 2020 Quick Start Guide
Quick Start Guide 17
Page 18
Quick Start Guide March 2020
18 Emerson.com/Rosemount
Page 19
March 2020 Quick Start Guide
Quick Start Guide 19
Page 20
*00825-0100-4541*
00825-0100-4541, Rev. DE
Quick Start Guide
March 2020
Global Headquarters
Emerson Automation Solutions 6021 Innovation Blvd. Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 204 8889 RFQ.RMD-RCC@Emerson.com
Latin America Regional Office
Emerson Automation Solutions 1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA
+1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@Emerson.com
Asia Pacific Regional Office
Emerson Automation Solutions 1 Pandan Crescent Singapore 128461
+65 6777 8211 +65 6777 0947 Enquiries@AP.Emerson.com
North America Regional Office
Emerson Automation Solutions 8200 Market Blvd. Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 204 8889 RMT-NA.RCCRFQ@Emerson.com
Europe Regional Office
Emerson Automation Solutions Europe GmbH Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland
+41 (0) 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@Emerson.com
Middle East and Africa Regional Office
Emerson Automation Solutions Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
+971 4 8118100 +971 4 8865465 RFQ.RMTMEA@Emerson.com
Linkedin.com/company/Emerson-
Automation-Solutions
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/
RosemountMeasurement
©
2020 Emerson. All rights reserved.
Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.
Loading...