Rosemount 781 Specifications

Product Data Sheet
February 2018
00813-0300-4410, Rev AD
Emerson™ Wireless 1410D Gateway with 781 Field Link
Gateway connects the WirelessHART
Easy configuration and management of self-organizing networks
Easy integration into control systems and data applications through serial and EtherNet connections
Greater than 99 percent data reliability with industry proven security
Wireless capabilities extend the full benefits of Plantweb
®
self-organizing networks with any host system
architecture to previously inaccessible locations
Emerson Wireless 1410D Gateway and 781 Field Link

Emerson Wireless Solution

IEC 62591 (WirelessHART)... the industry standard
Self-organizing, adaptive mesh routing
No wireless expertise required, network automatically finds the best
communication paths
The self-organizing, self-healing network manages multiple communication paths
for any given device. If an obstruction is introduced into the network, data will continue to flow because the device already has other established paths. The network will then lay in more communication paths as needed for that device
Reliable wireless architecture
Standard IEEE 802.15.4 radios
2.4 GHz ISM band sliced into 15 radio-channels
Time Synchronized Channel Hopping to avoid interference from other radios,
®
, and EMC sources and increase reliability
Wi-Fi
Direct sequence spread spectrum (DSSS) technology delivers high reliability in
challenging radio environment
February 2018
Emerson Wireless
Seamless integration via LAN to all existing host systems
Native integration into Ovation
Gateways interface with existing host systems via LAN using industry standard
protocols including OPC, Modbus® TCP/IP, and Modbus RTU
Layered security keeps your network safe
All wireless data is encrypted so your data is kept safe
All wireless devices are authenticated so you know exactly what is on your network
Third party security certifications including Achilles and FIPS-197 certification
demonstrate Emerson's commitment to security
Complete control of your network using the Gateway secure web interface
SmartPower™ solutions
Optimized Emerson instrumentation, both hardware and software, to extend power module life
SmartPower technologies enable predictable power life
Contents
is transparent and seamless
Emerson Wireless 1410D Gateway and 781 Field Link . . .3
Emerson Wireless 1410D Gateway . . . . . . . . . . . . . . . . . . . .4
Emerson Wireless 781 Field Link . . . . . . . . . . . . . . . . . . . . . .6
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Product certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Emerson.com/Rosemount
February 2018

Emerson Wireless 1410D Gateway and 781 Field Link

Emerson Wireless 1410D Gateway and 781 Field Link
Gain real-time process information with greater than 99 percent wireless data reliability
The Emerson Wireless 1410D Gateway with 781 Field Link automatically manages wireless communications in constantly
changing environments
Native integration with DeltaV
networks
Connect to data historians, legacy host systems, and other applications through EtherNet, Modbus TCP, Modbus RTU, OPC,
EtherNet/IP
, and HART® outputs
and Ovation automation systems provides simple and fast commissioning for wireless field
Guarantee system availability with redundant Wireless Gateways
Never lose the wireless network with hot standby capability and automatic
fault detection
Wireless Gateways function as a single system, eliminating the need for
duplicate host integration
One-click configuration and plug-and-play architecture
Complete wireless network configuration tools provided with each Gateway
The integrated web interface allows easy configuration of the wireless network and data
integration without the need to install additional software
Complimentary AMS Wireless Configurator software provides Emerson Device
Dashboards to configure devices and view diagnostic data
Drag and drop device provisioning enables a secure method to add new wireless devices
to the wireless field network
Emerson.com/Rosemount
3
Emerson Wireless 1410D Gateway and 781 Field Link
February 2018

Emerson Wireless 1410D Gateway

Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 8 for more information on material selection
Table 1. Emerson Wireless 1410D Gateway Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Model Product description
1410 Wireless Gateway, 2.4 GHz DSSS, WirelessHART, Webserver, AMS Ready, HART-IP
Wireless configuration
(1)
D
100 Device Network with Emerson 781 Field Link (10.5 to 30 Vdc)
EtherNet communications - physical connection
(2)(3)
1
(4)(5)(6)
2
Single EtherNet connection
Dual EtherNet connection
Serial communication
N None
(7)
A
Modbus RTU via RS-485
EtherNet communication - data protocols
D1 Modbus TCP/IP
D2 OPC
D3 EtherNet/IP
D4 Modbus TCP/IP, OPC
D5 EtherNet/IP, Modbus TCP/IP
D6 EtherNet/IP, OPC
(8)
E1
E2
E3
(8)
(9)
DeltaV ready
Ovation ready
Webserver only
Antenna options
WNA For use with the Emerson Wireless 781 Remote Field Link
Product certifications
NA No approvals
N1 ATEX Type n
N5 USA Division 2, Non-incendive
N6 Canada Division 2, Non-incendive
N7 IECEx Type n
4
Emerson.com/Rosemount
February 2018
Emerson Wireless 1410D Gateway and 781 Field Link
Table 1. Emerson Wireless 1410D Gateway Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Redundancy options
(10)(11)
RD Gateway redundancy
1. Must order the Emerson Wireless 781Remote Field Link. Reference Emerson Wireless 781 Field Link on page 6 for detail s.
2. Single active 10/100 baseT EtherNet port with RJ45 connector.
3. Additional ports disabled.
4. Dual active 10/100 baseT EtherNet ports with RJ45 connectors.
5. Multiple active ports have separate IP addresses, firewall isolation, and no packet forwarding.
6. Selection of Dual EtherNet option code 2 is recommended.
7. Convertible to RS232 via adapter, not included with Gateway.
8. Includes Modbus TCP and OPC.
9. Requires (A) Modbus RTU via RS-485 Communication protocol.
10. Requires the selection of Dual EtherNet option code 2.
11. Not available with EtherNet/IP option codes D3, D5, and D6.
Emerson.com/Rosemount
5
Emerson Wireless 1410D Gateway and 781 Field Link
February 2018

Emerson Wireless 781 Field Link

Table 2. Emerson Wireless 781 Field Link Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Model Product description
781 Wireless Field Link
Network capacity and physical connection
A1 100 device capacity, RS485
(1)
C1
25 Device Capacity, RS485
Housing
D Dual compartment housing - aluminum
E Dual compartment housing - stainless steel
Conduit threads
1
1
/2–14 NPT
Product certifications
(2)
I3
I5
I6
I1
I7
KD
KL
IM
(2)
(2)
(2)
(2)
(2)
(2)
(2)
China Intrinsic Safety
USA Intrinsically Safe, Non-incendive
Canada Intrinsically Safe
ATEX Intrinsic Safety
IECEx Intrinsic Safety
USA and Canada Intrinsically Safe, ATEX and IECEx Intrinsic Safety
USA and Canada Intrinsically Safe, ATEX Intrinsic Safety
Technical Regulations Customs Union (EAC) Intrinsic Safety
NA No approvals
Wireless update rate, operating frequency, and protocol
WA3 User configurable update rate, 2.4 GHz DSSS, WirelessHART
Omnidirectional wireless antenna and SmartPower
WM3 Extended range, external antenna, line power 10 to 30 Vdc
Display
M5 LCD display
6
Emerson.com/Rosemount