Emerson™ Wireless 1410D Gateway with 781
Field Link
Gateway connects the WirelessHART
Easy configuration and management of self-organizing networks
Easy integration into control systems and data applications through serial and EtherNet connections
Seamless integration into AMS Device Manager
Greater than 99 percent data reliability with industry proven security
Wireless capabilities extend the full benefits of Plantweb
®
self-organizing networks with any host system
™
architecture to previously inaccessible locations
Emerson Wireless 1410D Gateway and 781 Field Link
Emerson Wireless Solution
IEC 62591 (WirelessHART)... the industry standard
Self-organizing, adaptive mesh routing
No wireless expertise required, network automatically finds the best
communication paths
The self-organizing, self-healing network manages multiple communication paths
for any given device. If an obstruction is introduced into the network, data will
continue to flow because the device already has other established paths. The
network will then lay in more communication paths as needed for that device
Reliable wireless architecture
Standard IEEE 802.15.4 radios
2.4 GHz ISM band sliced into 15 radio-channels
Time Synchronized Channel Hopping to avoid interference from other radios,
®
, and EMC sources and increase reliability
Wi-Fi
Direct sequence spread spectrum (DSSS) technology delivers high reliability in
challenging radio environment
February 2018
Emerson Wireless
Seamless integration via LAN to all existing host systems
Native integration into Ovation
Gateways interface with existing host systems via LAN using industry standard
protocols including OPC, Modbus® TCP/IP, and Modbus RTU
Layered security keeps your network safe
All wireless data is encrypted so your data is kept safe
All wireless devices are authenticated so you know exactly what is on your network
Third party security certifications including Achilles and FIPS-197 certification
demonstrate Emerson's commitment to security
Complete control of your network using the Gateway secure web interface
SmartPower™ solutions
Optimized Emerson instrumentation, both hardware and software, to extend power module life
SmartPower technologies enable predictable power life
Contents
™
is transparent and seamless
Emerson Wireless 1410D Gateway and 781 Field Link . . .3
Dashboards to configure devices and view diagnostic data
Drag and drop device provisioning enables a secure method to add new wireless devices
to the wireless field network
Emerson.com/Rosemount
3
Emerson Wireless 1410D Gateway and 781 Field Link
February 2018
Emerson Wireless 1410D Gateway
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment.
See page 8 for more information on material selection
Table 1. Emerson Wireless 1410D Gateway Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
100 Device Network with Emerson 781 Field Link (10.5 to 30 Vdc)
EtherNet communications - physical connection
(2)(3)
1
(4)(5)(6)
2
Single EtherNet connection
Dual EtherNet connection
Serial communication
NNone
(7)
A
Modbus RTU via RS-485
EtherNet communication - data protocols
D1Modbus TCP/IP
D2OPC
D3EtherNet/IP
D4Modbus TCP/IP, OPC
D5EtherNet/IP, Modbus TCP/IP
D6EtherNet/IP, OPC
(8)
E1
E2
E3
(8)
(9)
DeltaV ready
Ovation ready
Webserver only
™
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Antenna options
WNAFor use with the Emerson Wireless 781 Remote Field Link
Product certifications
NANo approvals
N1ATEX Type n
N5USA Division 2, Non-incendive
N6Canada Division 2, Non-incendive
N7IECEx Type n
4
★
★
★
★
Emerson.com/Rosemount
February 2018
Emerson Wireless 1410D Gateway and 781 Field Link
Table 1. Emerson Wireless 1410D Gateway Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Redundancy options
(10)(11)
RDGateway redundancy
1.Must order the Emerson Wireless 781Remote Field Link. Reference Emerson Wireless 781 Field Link on page 6 for detail s.
2.Single active 10/100 baseT EtherNet port with RJ45 connector.
3.Additional ports disabled.
4.Dual active 10/100 baseT EtherNet ports with RJ45 connectors.
5.Multiple active ports have separate IP addresses, firewall isolation, and no packet forwarding.
6.Selection of Dual EtherNet option code 2 is recommended.
7.Convertible to RS232 via adapter, not included with Gateway.
8. Includes Modbus TCP and OPC.
9.Requires (A) Modbus RTU via RS-485 Communication protocol.
10.Requires the selection of Dual EtherNet option code 2.
11.Not available with EtherNet/IP option codes D3, D5, and D6.
★
Emerson.com/Rosemount
5
Emerson Wireless 1410D Gateway and 781 Field Link
February 2018
Emerson Wireless 781 Field Link
Table 2. Emerson Wireless 781 Field Link Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
ModelProduct description
781Wireless Field Link
Network capacity and physical connection
A1100 device capacity, RS485
(1)
C1
25 Device Capacity, RS485
Housing
DDual compartment housing - aluminum
EDual compartment housing - stainless steel
Conduit threads
1
1
/2–14 NPT
Product certifications
(2)
I3
I5
I6
I1
I7
KD
KL
IM
(2)
(2)
(2)
(2)
(2)
(2)
(2)
China Intrinsic Safety
USA Intrinsically Safe, Non-incendive
Canada Intrinsically Safe
ATEX Intrinsic Safety
IECEx Intrinsic Safety
USA and Canada Intrinsically Safe, ATEX and IECEx Intrinsic Safety
USA and Canada Intrinsically Safe, ATEX Intrinsic Safety
Technical Regulations Customs Union (EAC) Intrinsic Safety
★
★
★
★
★
★
★
★
★
★
★
★
★
★
NANo approvals
Wireless update rate, operating frequency, and protocol