Rosemount 5400 Series Cone Antenna with Threaded Connection Quick Start Guide

Page 1
00825-0500-4026, Rev AA

Rosemount® 5400 Series

Cone Antenna with Threaded Connection
Quick Start Guide
September 2015
Page 2
Quick Start Guide
Standard tools, e.g. screwdriver, wrench, pliers
Gasket (for flanged connection)
Allen key (supplied)
Customer supplied flange (for flanged connection)
2 - 11.5 NPT 3 - 8 NPT 4 - 8 NPT
Anti-seize paste or PTFE tape
Failure to follow safe installation and service guidelines could result in death or serious injury.
Make sure the transmitter is installed by qualified personnel and in accordance with applicable code of
practice.
Use the equipment only as specified in the relevant Quick Start Guide (document number
00825-0100-4026) and Reference Manual (document number 00809-0100-4026). Failure to do so may impair the protection provided by the equipment.
Explosions could result in death or serious injury.
Verify that the operating environment of the transmitter is consistent with the appropriate hazardous
locations specifications.
To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing.Before connecting a Field Communicator in an explosive atmosphere, make sure the instruments in the
loop are installed in accordance with intrinsically safe or non-incendive field wiring practices.
Electrical shock can result in death or serious injury.
Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical
shock.
Make sure the main power to the Rosemount 5400 Series Transmitter is off and the lines to any other
external power source are disconnected or not powered while wiring the transmitter.
September 2015
Process leaks could result in death or serious injury.
Make sure that the transmitter is handled carefully. If the process seal is damaged, gas might escape from
the tank if the transmitter head is removed from the antenna.
To avoid process leaks, only use O-rings designed to seal with the corresponding flange adapter.
Note
Be careful of sharp edges. Wear protective gloves!

Required equipment

Contents
Required equipment . . . . . . . . . . . . . . . . . . . . . . 2
Installation procedure . . . . . . . . . . . . . . . . . . . . 3
Mounting on threaded tank connection . . . . . 4
Mounting on customer supplied flange . . . . . 6
Page 3
September 2015
page 4-5
page 6-9
d
D
page 10-15
d
D

Installation procedure

Threaded tank connection
Tank connection with customer supplied flange
Antenna diameter (D) Flange hole diameter (d)
Quick Start Guide
Antenna diameter (D) > Flange hole diameter (d)
Antenna is shipped unmounted for field installation.
Page 4
Quick Start Guide
Use anti-seize paste or PTFE tape
according to your site procedures.

Mounting on threaded tank connection

1. Seal and protect threads.
2. Lower the device into the tank.
September 2015
Page 5
September 2015
Torque 30 Lbft (40 Nm)
3. Screw the adapter into the process connection.
4. Rotate the transmitter head so the cable entries/display face the desired direction.
Quick Start Guide
5. Proceed with electrical installation.
For further instructions, see the Rosemount 5400 Series Quick Start Guide (document number 00825-0100-4026).
Page 6
Quick Start Guide
d
D
Gasket

Mounting on customer supplied flange

Antenna diameter (D) Flange hole diameter (d)
1. Place a gasket on the tank flange.
September 2015
2. Place the customer supplied flange over the gasket.
Page 7
September 2015
Use anti-seize paste or PTFE tape
according to your site procedures.
3. Tighten the bolts and nuts with sufficient torque for the flange and gasket choice.
4. Seal and protect threads.
Quick Start Guide
Page 8
Quick Start Guide
5. Lower the device into the tank.
6. Screw the adapter into the process connection.
September 2015
Page 9
September 2015
Torque 30 Lbft (40 Nm)
7. Rotate the transmitter head so the cable entries/display face the desired direction.
Quick Start Guide
8. Proceed with electrical installation.
For further instructions, see the Rosemount 5400 Series Quick Start Guide (document number 00825-0100-4026).
Page 10
Quick Start Guide
d
D
Note
Handle the adapter carefully to prevent damage to the PTFE seal.
High frequency version Low frequency version
Antenna diameter (D) > Flange hole diameter (d)
1. Place the device on a workbench.
2. Carefully remove the transmitter head.
September 2015
10
Page 11
September 2015
Note
After pre-mounting the screws, make sure to finish the installation procedure immediately. The screws come with pre-applied threadlocker, designed for permanent locking.
Use anti-seize paste or PTFE tape
according to your site procedures.
3. Insert the six M4 screws and tighten them two to three turns.
4. Seal and protect threads.
Quick Start Guide
5. Place the customer supplied flange on the tank flange.
11
Page 12
Quick Start Guide
6. Tighten the adapter by hand.
7. Flip the flange over.
September 2015
12
Page 13
September 2015
Gasket
8. Fit the antenna onto the adapter and tighten the six M4 screws.
9. Carefully lift the antenna and flange assembly.
Quick Start Guide
10. Place a gasket on the tank flange.
13
Page 14
Quick Start Guide
11. Lower the antenna and flange assembly into the tank.
12. Tighten the bolts and nuts with sufficient torque for the flange and gasket choice.
September 2015
14
Page 15
September 2015
13. Screw the adapter until it is properly tightened.
14. Mount the transmitter head and tighten the nut (torque 30 Lbft, 40 Nm).
Quick Start Guide
15. Proceed with electrical installation.
For further instructions, see the Rosemount 5400 Series Quick Start Guide (document number 00825-0100-4026).
15
Page 16
Global Headquarters
Emerson Process Management
6021 Innovation Blvd. Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@EmersonProcess.com
North America Regional Office
Emerson Process Management
8200 Market Blvd. Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.com
Latin America Regional Office
Emerson Process Management
1300 Concord Terrace, Suite 400 Sunrise, Florida, 33323, USA
+1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@EmersonProcess.com
Europe Regional Office
Emerson Process Management Europe GmbH
Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland
+41 (0) 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@EmersonProcess.com
Asia Pacific Regional Office
Emerson Process Management Asia Pacific Pte Ltd
1 Pandan Crescent Singapore 128461
+65 6777 8211 +65 6777 0947
Enquiries@AP.EmersonProcess.com
Middle East and Africa Regional Office
Emerson Process Management
Emerson FZE P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
+971 4 8118100 +971 4 8865465
RFQ.RMTMEA@Emerson.com
*00825-0500-4026*
Quick Start Guide
00825-0500-4026, Rev AA
September 2015
Standard Terms and Conditions of Sale can be found at: www.rosemount.com\terms_of_sale. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and Rosemount logotype are registered trademarks of Rosemount Inc. All other marks are the property of their respective owners. © 2015 Emerson Process Management. All rights reserved.
Loading...