1
2
3
4
5
6
ROSEMOUNT 214C TEMPERATURE SENSOR MOUNTING STYLES
AND EXTENSIONS
A
7
8
9
10
11
12
13
14
REVISION
15
REVISION TABLE
ECO NO.
APP'D
16
8/15/17N. LOYARTC1068820AD
DATE
A
B
C
COMPRESSION FITTINGS
(CA, CB, CC, CD)
ADJUSTABLE SPRING
LOADED ADAPTER (SA)
SPRING LOADED ADAPTER
WITH THERMOWELL CONTACT
INDICATION (SW)
COMPACT SPRING LOADED ADAPTER
STYLE (SC) or COMPACT WELDED ADAPTER
STYLE (WC)
2.15
[54,6]
.84
SPRING LOADED ADAPTER STYLE (SL)
OR WELDED ADAPTER STYLE (WA)
FIXED
STYLE (FA)
DESCRIPTION
ADD HOUSING
B
UNION
STYLE (UA)
C
D
E
3.60
[91.4]
1.04
[26.4]
[21,3]
3.32
[84.3]
.84
[21.3]
D
"N"
E
"E"
F
G
H
1.29 [32.8]
OR
1.49 [37.9]
OR
1.76 [44.7]
OR
1.82 [46.2]
2.97
[75.4]
.84
[21.3]
1/2-14 NPT
"X"
.87
[22]
1/2-14 NPT
F
G
H
J
K
1/8-27 NPT
OR
1/4-18 NPT
OR
1/2-14 NPT
OR
3/4-14 NPT
"L"
J
.23
[5.92]
K
L
SCALE 5/4
1. .75 [19] CLEARANCE REQUIRED TO REMOVE COVERS.
M
NOTES:
FORM REV AC
SENSORS
ADAPTER LENGTH (WITH THREAD ENGAGEMENT)
N = ADAPTER LENGTH + E
EQUATIONS
WITH EXTENSION
X = E+L
WITHOUT EXTENSION
X = L
EXTENSIONS
SPECIFICATIONS.
©2015 ROSEMOUNT INC.
ACCORDANCE WITH
THESE DRAWINGS ARE IN
ROSEMOUNT INC CERTIFIES
ROSEMOUNT ENGINEERING
REFERENCE ROSEMOUNT
UNIT NOTES IN INCHES [mm].
PRODUCT SPECIFICATIONS.
PRODUCT DATA SHEETS FOR
TITLE
CLICK HERE
DR.
APP'D
CAD MAINTAINED, (PRO/E)
3RD ANGLE
™
ROSEMOUNT 214C
TYPE I DRAWING
6/25/15J. ARMSTRONG
12/02/15O. GHAZI
DRAWING NO.
SHEET
SIZE
SCALE
5/4D
00214-7000
OF
31
L
M
1
2
3
4
5
ROSEMOUNT 214C SENSOR CONNECTION HEADS
6
7
8
9
10
11
12
13
14
15
16
A
B
C
Ex-d CABLE GLAND
(GN1, GN2)
M20 x 1.5 NPT
OR
1/2-14 NPT
OR
3/4-14 NPT
3.08
[78,2]
ROSEMOUNT ALUMINUM (AR1)
OR ROSEMOUNT SST (SR1)
4.16
[105.6]
ROSEMOUNT ALUMINUM WITH DISPLAY COVER (AR2)
OR SST ROSEMOUNT SST WITH DISPLAY COVER (SR2)
COVER CLAMP
AND GROUND SCREW
(OPTION CODE DEPENDANT)
A
B
C
D
E
CABLE ENTRY
EMV CABLE GLAND
(GN6, GN7)
CABLE ENTRY
M20 x 1.5 NPT
OR
1/2-14 NPT
OR
3/4-14 NPT
CONDUIT ENTRY
CONNECTION
2.24
[57]
5.24
[133]
3.94
D
[100,0]
CERTIFICATION
LABEL
E
2.56
[65,0]
F
G
CABLE GLAND
(GP1, GP2)
CABLE ENTRY
M20 x 1.5 NPT
OR
1/2-14 NPT
OR
3/4-14 NPT
1/2-14 NPT
ALUMINUM CONNECTION
HEAD WITH TERMINAL STRIP (AT1)
F
ALUMINUM CONNECTION HEAD WITH
TERMINAL STRIP AND EXTENDED COVER (AT3)
G
4.91
H
J
K
1.20
[30,5]
4.09
[103,9]
3.47
[88,1]
[124,6]
5.29
[134]
H
J
K
L
M
FORM REV AC
CONDUIT ENTRY
CONNECTION
CERTIFICATION
LABEL
3/4-14 NPT
3.92
[99,6]
GROUND SCREW
(OPTION CODE DEPENDANT)
(COVER CLAMP OPTION AVAILABLE)
1/2-14 NPT
SPECIFICATIONS.
©2015 ROSEMOUNT INC.
ACCORDANCE WITH
THESE DRAWINGS ARE IN
ROSEMOUNT INC CERTIFIES
ROSEMOUNT ENGINEERING
REFERENCE ROSEMOUNT
UNIT NOTES IN INCHES [mm].
PRODUCT SPECIFICATIONS.
PRODUCT DATA SHEETS FOR
TITLE
CLICK HERE
DR.
APP'D
CAD MAINTAINED, (PRO/E)
3RD ANGLE
™
ROSEMOUNT 214C
TYPE I DRAWING
6/25/15J. ARMSTRONG
12/02/15O. GHAZI
DRAWING NO.
SHEET
SIZE
SCALE
5/4D
00214-7000
OF
32
L
M