Rosemount 1595 Specifications

March 2015
Rosemount DP Flow
Rosemount 1595 Conditioning Orifice Plate
Rosemount 1595 Conditioning Orifice combines a flow conditioner with an orifice plate into a highly accurate primary element.
Requires only 2 diameters of straight pipe run upstream and downstream from most flow disturbances
Available in 2 to 24-in. (50 - 600 mm) line sizes
Additional Information
Specifications: Dimensional Drawings: page 229 Installation and Flowmeter Orientation: page 189
Ordering information
Table 1. Rosemount 1595 Conditioning Orifice Plate Ordering Table
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Product description
1595 Conditioning Orifice Plate
page 168
Plate type
P Paddle, Square Edged
(1)(2)
U
Universal, Square Edged
Line size
020 2-in. (50 mm)
030 3-in. (76 mm)
040 4-in. (100 mm)
060 6-in. (150 mm)
080 8-in. (200 mm)
100 10-in. (250 mm)
120 12-in. (300 mm)
140 14-in. (350 mm)
160 16-in. (400 mm)
180 18-in. (450 mm)
200 20-in. (500 mm)
240 24-in. (600 mm)
Flange rating
A1 ANSI Class 150 Raised Face (not compatible with standard ASME B16.36 Orifice Flanges)
A3 ANSI Class 300 Raised Face
A6 ANSI Class 600 Raised Face
A9 ANSI Class 900 Raised Face
AF ANSI Class 1500 Raised Face
AT ANSI Class 2500 Raised Face
www.rosemount.com
165
Rosemount DP Flow
Table 1. Rosemount 1595 Conditioning Orifice Plate Ordering Table
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
(1)
D1
(1)
D2
(1)
D3
(1)
D4
(1)
D5
(1)
D6
(1)
R3
(1)
R6
(1)
R9
(1)
RF
(1)
RT
Material type
DIN PN 10 (only available with Plate Type P)
DIN PN 16 (only available with Plate Type P)
DIN PN 25 (only available with Plate Type P)
DIN PN40 (only available with Plate Type P)
DIN PN 63 (only available with Plate Type P)
DIN PN 100 (only available with Plate Type P)
ANSI Class 300 Ring Joint (only available with Orifice Plate Type code U and requires Plate Holder code PH)
ANSI Class 600 Ring Joint (only available with Orifice Plate Type code U and requires Plate Holder code PH)
ANSI Class 900 Ring Joint (only available with Orifice Plate Type code U and requires Plate Holder code PH)
ANSI Class 1500 Ring Joint (only available with Orifice Plate Type code U and requires Plate Holder code PH)
ANSI Class 2500 Ring Joint (only available with Orifice Plate Type code U and requires Plate Holder code PH)
March 2015
S 316/316L Stainless Steel
M Alloy 400
H Alloy C-276
Orifice plate thickness Plate type P Plate type U
A 0.125-in. Line sizes 2 to 4-in. (50 to 100 mm) Line size 2 to 6-in. (50 to 150 mm)
B 0.250-in. Line sizes 6 to 12-in. (150 to 300 mm) Line size 8 to 12-in. (200 to 300 mm)
C 0.375-in. Line sizes 14 to 20-in. (350 to 500 mm) N/A
D 0.500-in. Line size 24-in. (600 mm) N/A
Beta ratio
020 0.20 Beta Ratio
040 0.40 Beta Ratio
050 0.50 Beta Ratio
065 0.65 Beta Ratio (0.60 beta ratio for Line Size option 020 only)
Options (include with selected model number)
Extended product warranty
WR3 3-year limited warranty
WR5 5-year limited warranty
Flow calibration
WD Discharge Coefficient Verification (full 10 points)
Plate holder
(1)
PH
Plate Holder for Universal Type Orifice Plate for use with RTJ flange or section
166
www.rosemount.com
Loading...