Rosemount 1151 Data sheet

Page 1
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009
Rosemount 1151
Rosemount 1151 Pressure Transmitter
• Proven field performance and reliability
• Commitment to continuous improvement
• Reference accuracy of 0.075%
• Rangeability of 50:1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-3
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-8
Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-10
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-16
www.rosemount.com
Contents
Page 2
Product Data Sheet
00813-0100-4360, Rev HA
Rosemount 1151
Catalog 2008 - 2009
Leading a tradition of excellence
With over five million transmitters installed worldwide, the Rosemount 1151 continues to offer industry leading value. Changing customer needs and new technologies have driven product improvements, while advanced manufacturing and testing processes have guaranteed product quality. Even today, the Rosemount 1151 is world-reowned for proven field reliability and longevity.

Proven field performance and reliability

For over 35 years, the 1151 has provided the process control industry with unsurpassed service and reliability in even the harshest of environments. The lasting customer preference results from a combination of advanced technology, and a tradition of field proven performance.

Commitment to continuous improvement

Through ongoing focus on continuous improvement, ±0.075% reference accuracy has been accomplished as a result of manufacturing and engineering enhancements. In addition, Smart electronics offer rangeability to 50:1, reducing the number of transmitters to specify, procure, and carry in inventory. A modular design allows interchangeable mechanical and electrical components, providing backward and forward compatibility.

Rosemount Pressure Solutions

Rosemount 3051S Series of Instrumentation

Scalable pressure, flow and level measurement solutions improve installation and maintenance practices.

Rosemount 3095 Mass Flow Transmitter

Accurately measures differential pressure, static pressure and process temperature to dynamically calculate fully compensated mass flow.

Rosemount 305, 306 and 304 Manifolds

Factory-assembled, calibrated and seal-tested transmitter-to-manifold assemblies reduce installation costs.

Rosemount 1199 Diaphragm Seals

Provides reliable, remote measurements of process pressure and protects the transmitter from hot, corrosive, or viscous fluids.

Orifice Plate Primary Element Systems: Rosemount 1495 and 1595 Orifice Plates, 1496 Flange Unions and 1497 Meter Sections

A comprehensive offering of orifice plates, flange unions and meter sections that are easy to specify and order. The 1595 Conditioning Orifice provides superior performance in tight fit applications.

Application flexibility

The 1151 offers a variety of configurations for differential, gage, absolute and liquid- level measurements including integrated solutions for pressure, level, and flow. High pressure models allow static line pressures up to 4500 psi (310 bar). Multiple wetted materials, as well as alternative fill fluids ensure process compatibility. Smart, analog and low-power electronics are available to meet specific application requirements.
Annubar® Flowmeter Series: Rosemount 3051SFA
®
ProBar
The state-of-the-art, fifth generation Rosemount 485 Annubar combined with the 3051S or 3095 MultiVariable transmitter creates an accurate, repeatable and dependable insertion-type flowmeter.

Compact Orifice Flowmeter Series: Rosemount 3051SFC, 3095MFC, and 405

Compact Orifice Flowmeters can be installed between existing flanges, up to a Class 600 (PN100) rating. In tight fit applications, a conditioning orifice plate version is available, requiring only two diameters of straight run upstream and two downstream.

ProPlate® Flowmeter Series: Rosemount 3051SFP ProPlate, 3095MFP Mass ProPlate, and 1195

These integral orifice flowmeters eliminate the inaccuracies that become more pronounced in small orifice line installations. The completely assembled, ready to install flowmeters reduce cost and simplify installation.
, 3095MFA Mass ProBar®, and 485
Pressure-2
Page 3
Product Data Sheet
accuracy 0.02
URL
span
--------------
⎝⎠
⎛⎞
0.1 %ofcalibratedspan±=
0.2 0.05 x
URL
span
-------------
⎝⎠
⎛⎞
+ % of calibrated flow span±
00813-0100-4360, Rev HA Catalog 2008 - 2009
Rosemount 1151

Specifications

PERFORMANCE SPECIFICATIONS

(Zero-based calibrated ranges, reference conditions, silicone oil fill, 316 SST isolating diaphragms.)

Accuracy

Output Code S
Ranges 3 through 8, DP and GP transmitters; Ranges 4 through 7, HP transmitters
±0.075% of calibrated span for spans from 1:1 to 10:1 of URL. Between 10:1 and 50:1 of URL.
All other ranges and transmitters
±0.25% of calibrated span
Output Code S, square root mode
Output Codes E, G, L, and M
±0.2% of calibrated span for 1151DP Ranges 3 through 5. All other ranges and transmitters, ±0.25% of calibrated span.

Stability

Output Code S
±0.1% of URL for 2 years for DP and GP Ranges 3 through 8. (±0.25% for all other ranges and transmitters.)
Output Codes E and G
±0.2% of URL for six months for Ranges 3 through 5. (±0.25 for all other ranges.)
Output Codes L and M
±0.25% of URL for six months

Temperature Effect

Output Code S [–20 to 185 °F (–29 to 85 °C)]
For DP and GP transmitter Range 4 through 8; HP transmitter Range 4 through 7:
Zero Error = ±0.2% URL per 100 °F (56 °C) Total Error = ±(0.2% URL + 0.18% of calibrated span) per 100 °F; For Range 3, double the stated effects. For other ranges and transmitters follow analog temperature specifications (Output Code E).
Output Code E, G, L, and M
[–20 to 200 °F (–29 to 93 °C)] For Ranges 4 through 0
Zero Error = ±0.5% URL per 100 °F. Total Error = ±(0.5% URL + 0.5% of calibrated span) per 100 °F; double the effect for Range 3.
(1)
Static Pressure Effect – DP Transmitters
DP Transmitters
Zero Error
±0.25% of URL for 2,000 psi (13790 kPa) for Range 4 and 5 or ±0.5% for other ranges, correctable through rezeroing at line pressure.
Span Er ror
Correctable to ±0.25% of input reading per 1,000 psi (6895 kPa), or to ±0.5% for Range 3.
HP Transmitters
Zero Error
±2.0% of URL for 4,500 psi (31027 kPa), correctable through rezeroing at line pressure.
Span Er ror
Correctable to ±0.25% of input reading per 1,000 psi (6895 kPa).

Vibration Effect

0.05% of URL per g to 200 Hz in any axis

Power Supply Effect

Output Codes S, E, and G
Less than 0.005% of output span per volt
Output Codes L, M
Output shift of less than 0.05% of URL for a 1 V power supply shift

Load Effect

Output Codes S, E, and G
No load effect other than the change in power supplied to the transmitter.
Output Codes L, M
Less than 0.05% of URL effect for a change in load from 100k to infinite ohms.

Short Circuit Condition (Low Power Only)

No damage to the transmitter will result when the output is shorted to common or to power supply positive (limit 12 V).

EMI/RFI Effect

Output shift of less than 0.1% of span when tested to SAMA PMC
33.1 from 20 to 1000 MHz and for field strengths up to 30 V/m.
(1) Accuracy for Range 9, GP transmitter at 40:1 is ±0.7%
of calibrated span.
Pressure-3
Page 4
Rosemount 1151
R
max
R
L
R
min
V
min
V
S
V
max
0
Operating
Region
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009

Mounting Position Effect

Zero shift of up to 1 inH2O (0.25 kPa).
With liquid level diaphragm in vertical plane, zero shift of up to 1
O (0.25 kPa). With liquid level diaphragm in horizontal plane,
inH
2
zero shift of up to 5 inH extended units. All zero shifts can be calibrated out. No effect on span.
O (1.25 kPa) plus extension length on
2

FUNCTIONAL SPECIFICATIONS

Service

Liquid, gas, and vapor applications

Ranges

See Table 2 for ranges. Minimum span equals the upper range limit (URL) divided by rangedown. Rangedown varies with the output code See Table 1.

Outputs

Code S, Smart
4–20 mA dc, user selectable for linear or square root output. Digital process variable superimposed on 4–20 mA signal, available to any host that conforms to the HART
Code E, Analog
4–20 mA dc, linear with process pressure
Code G, Analog
10–50 mA dc, linear with process pressure
Code L, Low Power
0.8 to 3.2 V dc, linear with process pressure
Code M, Low Power
1 to 5 V dc, linear with process pressure

Current Consumption Under Normal Operating Conditions (Low Power Only)

Output Code L
1.5 mA dc
Output Code M
2.0 mA dc
®
protocol.

Span and Zero

Output Code S
Span and zero may be accessed with local adjustments or remotely through a HART-compatible Interface.
Output Codes E, G, L, and M
Span and zero are continuously adjustable.

Power Supply

External power supply required. Transmitter operates according to the following requirements:
Output Codes S, E
12 to 45 V dc with no load
Output Code G
30 to 85 V dc with no load
Output Code L
5 to 12 V dc
Output Code M
8 to 14 V dc
Where:
Code V
(1)
S
(2)
E G308501100 R L 5 12 Low Power Minimum Load M814
(1) A minimum of 250 ohms is required for communication.
(2) For CSA approvals V
minVmaxRminRmaxRL
12 45 0 1650 RL = 43.5 (VS – 12) 12 45 0 1650 RL = 50 (VS – 12)
= 42.4 V dc.
max
at Supply Voltage (VS)
= 20 (VS – 30)
L
Impedance: 100 k

Zero Elevation and Suppression

Output Codes S, E, and G
Zero elevation and suppression must be such that the lower range value is greater than or equal to the (–URL) and the upper range value is less than or equal to the (+URL). The calibrated span must be greater than or equal to the minimum span and less than or equal to the maximum span.
Output Code L
Zero is adjustable ±10% of URL and span is adjustable from 90 to 100% of URL.
Output Code M
Zero is adjustable ±50% of URL and span is adjustable from 50 to 100% of URL.
Pressure-4

Temperature Limits

Electronics Operating
Code S: –40 to 185 °F (–40 to 85 °C)
Code E: –40 to 200 °F (–40 to 93 °C)
Code G, L, M: –20 to 200 °F (–29 to 93 °C)
Sensing Element Operating
Silicone fill: –40 to 220 °F (–40 to 104 °C)
Inert fill: 0 to 160 °F (–18 to 71 °C)
Storage
Code S: –60 to 185 °F (–51 to 85 °C)
Codes E, G, L, M: –60 to 250 °F (–51 to 121 °C)
Page 5
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009

TABLE 1. Rangeability

Output Code Minimum Span Maximum Span
S (DP and GP, SST, Range 3–8; HP SST, Range 4–7) URL/50 2 URL S (All Others) URL/50 E, G URL/6 URL L URL/1.1 URL M URL/2 URL
(1) Transmitter is capable of measuring from –URL to URL.
(2) Accuracy specification for calibrated spans from 1:1 to 6:1 of URL only.

TABLE 2. Transmitter Range Availability by Model (URL = Upper Range Limit)

Range Code 1151 Ranges (URL) DP HP GP DP/GP/Seals AP LT
3 30 inH2O (7.46 kPa) NA NA NA NA 4 150 inH2O(37.3 kPa) • 5 750 inH2O (186.4 kPa) • 6 100 psi (689.5 kPa) • 7 300 psi (2,068 kPa) NA 8 1,000 psi (6,895 kPa) NA NA NA 9 3,000 psi (20,684 kPa) NA NA NA NA NA 0 6,000 psi (41,369 kPa) NA NA NA NA NA
(2)
Rosemount 1151
(1)
2 URL
(1)

TABLE 3. Upper Range Limits (URL)

Range Code bar mbar kg/cm
3 0.075 75 0.076 1.082 7.461 30 762 2.203 4 0.373 373 0.380 5.409 37.305 150 3810 11.013 5 1.865 1865 1.901 27.045 186.505 750 19050 55.065 6 6.90 6895 7.031 100 690 2773 70434 204 7 21 20685 21 300 2069 8319 211302 611 8 69 68950 70 1000 6895 27730 704340 2036 9 207 206850 211 3000 20685 83190 2113020 6108 0 413.686 413686 421.842 6000 41369 166378 4225992 12216.12
2
psi kPa inH2O @20 °C mmH2O @20 °C inHg @0 °C

TABLE 4. Output Code Availability

Code 1151 Output Options/Damping DP HP GP DP/GP/Seals AP LT
S 4–20 mA, Digital, Smart/Variable • E 4–20 mA, Linear, Analog/Variable • G 10–50 mA, Linear, Analog/Variable • L 0.8 to 3.2 V, Linear, Low Power/Fixed NA M 1 to 5 V, Linear, Low Power/Fixed NA

TABLE 5. Fill Fluid Specifications

Fill Fluid Temperature Limits
D.C.® 200 Silicone –40 to 400 °F (–40 to 205 °C) 0.934 0.00060 (0.00108) 9.5 D.C. 704 Silicone 60 to 400 °F (15 to 204 °C) 1.07 0.00053 (0.00095) 44
Inert Fill –50 to 350 °F (–45 to 177 °C) 1.85 0.0004 (0.000864) 6.5 Syltherm®XLT, Silicone –100 to 300 °F (–73 to 149 °C) 0.85 0.000666 (0.001199) 1.6 Glycerin and Water Propylene Glycol and Water Neobee M-20
(1) Temperature limits are reduced in vacuum service. Contact an Emerson Process Management representative for assistance.
(2) Glycerin and Water and Propylene Glycol and Water are not suitable for vacuum service.
(3) Not compatible with Buna-N or Ethylene-Propylene O-ring material.
®(3)
(2)
0 to 200 °F (–17 to 93 °C) 1.13 0.00019 (0.00034) 12.5
(3)
0 to 200 °F (–17 to 93 °C) 1.02 0.00019 (0.00034) 2.85 0 to 400 °F (–17 to 205 °C) 0.900 0.00056 (0.001008) 9.8
(1)
Specific Gravity
Coeff. of Therm. Exp. cc/cc/°F (cc/cc/°C)
Viscosity at 25 °C centistokes
Pressure-5
Page 6
Rosemount 1151
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009
Static Pressure and Overpressure Limits
115 1DP
0 psia to 2,000 psig (0 to 13.79 MPa) on either side without damage to transmitter. Operates within specifications from static line pressures of 0.5 psia (3.45 kPa) to 2,000 psig (13.79 MPa).
115 1HP
0 psia to 4,500 psig (0 to 31.02 MPa) on either side without damage to transmitter. Operates within specifications from 0.5 psia (3.45 kPa) to 4,500 psig (31.02 MPa). Consult an Emerson Process Management representative for higher Static Pressure options up to 6000 psi.
115 1AP
0 psia to 2,000 psia (0 to 13.79 MPa) without damage to transmitter. Operates within specifications from 0 psia to the upper range limit of the transmitter.
115 1GP
0 psia to 2,000 psig (0 to 13.79 MPa) for ranges to 1,000 psig (6.90 MPa), 4,500 psig (31.02 MPa) for the 3,000 psig (20.68 MPa) range, and 7,500 psig (51.71 MPa) for the 6,000 psig (41.37 MPa) range, without damage to the transmitter. Operates within specifications from 0.5 psia (3.45 kPa) to the upper range limit of the transmitter.
115 1LT

TABLE 6. Flange Pressure Rating

Standard Class/Rating Carbon Steel Stainless Steel
ANSI 150 285 psig ANSI 300 740 psig ANSI 600 1,480 psig DIN PN 10–40 40 bar DIN PN 10/16 16 bar DIN PN 25/40 40 bar
(1) At 100 °F (38 °C); the rating decreases with increasing
temperature.
(2) At 248 °F (120 °C); the rating decreases with increasing
temperature.
(1)
(1)
(1)
(2)
(2)
(2)
1,440 psig
275 psig 720 psig
40 bar 16 bar 40 bar
(1)
(1)
(1)
(2)
(2)
(2)
Burst Pressure All Models
10,000 psig (68.95 MPa) proof pressure on the flanges.
Transmitter Security (Output Code S)
Activating the transmitter security function prevents changes to the transmitter configuration, including local zero and span adjustments. Security is activated by an internal switch.
Overpressure Saturation Value (Output Code S)
If the sensor detects a negative overpressure value, the analog signal will be driven to 3.9 mA. If the sensor detects a positive overpressure value, the analog signal is driven to 20.8 mA.
Damping
Numbers given are for silicone fill fluid at room temperature. The minimum time constant is 0.2 seconds (0.4 seconds for Range 3). Inert-filled sensor values would be slightly higher.
Output Code S
Time constant is adjustable in 0.1 second increments from minimum to 16.0 seconds.
Output Codes E and G
Time constant continuously adjustable between minimum and
1.67 seconds.
Output Codes L, M
Damping is fixed at minimum time constant.
1151LT
Time constant continuously adjustable between 0.4 and 2.2 seconds with silicone oil fill, or 1.1 and 2.7 seconds with inert fill for flush models and electronics codes E or G.
Turn-on Time
Maximum of 2.0 seconds with minimum damping. Low power output is within 0.2% of steady state value within 200 ms after application of power.
Physical Specifications, Standard Configuration
Electrical Connections
1
/2–14 NPT conduit with screw terminals and integral test jacks compatible with miniature banana plugs (Pomona 2944, 3690, or equivalent). The HART Hand-Held Interface connections are fixed to the terminal block on smart transmitters.
Humidity Limits
0 to 100% relative humidity
Volumetric Displacement
Less than 0.01 in3 (0.16 cm3)
Failure Mode Alarm (Output Code S)
If self-diagnosis detects a gross transmitter failure, the analog signal will be driven below 3.9 mA or above 21 mA to alert the user. High or low alarm signal is user selectable.
Level 4–20 mA Saturation Value 4–20 mA Alarm Value
Low 3.9 mA 3.75 mA
High 20.8 mA 21.75 mA
Pressure-6
Wetted Materials
Isolating Diaphragms
316L SST, Hastelloy C-276, or Tantalum. See ordering table for availability per model type.
Drain/Vent Valves
316 SST or Hastelloy C-276, see ordering table for availability per model type.
Process Flanges and Adapters
Plated carbon steel, 316 SST or Hastelloy C-276, see ordering table for availability per model type.
Wetted O-rings
®
(other materials also available)
Viton
Page 7
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009
Rosemount 1151
Non-wetted Materials
Fill Fluid
Silicone oil or inert fill
Nuts and Bolts
Plated carbon steel
Blank flange (GP and AP only)
Plated carbon steel
Electronics Housing
Low-copper aluminum. NEMA 4X
Cover O-rings
Buna-N
Paint
Polyurethane
Process Connections
Rosemount 1151DP, HP, GP, AP
1
/4–18 NPT on 2.125-in. (54-mm) centers on flanges for
Ranges 3, 4, and 5.
1
/4–18 NPT on 2.188-in. (56-mm) centers on flanges for
Ranges 6 and 7.
1
/4–18 NPT on 2.250-in. (57-mm) centers on flanges for
Range 8.
1
/2–14 NPT on adapters.
For Ranges 3, 4, and 5, flange adapters can be rotated to give centers of 2.0 in. (51 mm), 2.125 in. (54 mm), or 2.250 in. (57 mm).
Rosemount 1151LT
High pressure side: 2-, 3-, or 4-in., Class 150, 300 or 600 flange; 50, 80, or 100 mm, PN 40 or 10/16 flange.
Low pressure side: 1/4–18 NPT on flange. 1/2–14 NPT on adapter.
Weight
12 lb (5.4 kg) for AP, DP, GP, and HP transmitters, excluding options. Meter option: Add 2 lb (1 kg)

TABLE 7. 1151LT Weight with Flange

(1)
Flange
2-in., Class 150 18 (8.2) N/A N/A N/A 3-in., Class 150 23 (10.4) 25 (11.3) 26 (11.8) 27 (12.3) 4-in., Class 150 29 (13.2) 32 (14.5) 34 (15.4) 36 (16.3) 2-in., Class 300 20 (9.1) N/A N/A N/A 3-in., Class 300 28 (12.7) 30 (13.6) 31 (14.1) 32 (14.5) 4-in., Class 300 38 (17.2) 41 (18.6) 43 (19.5) 45 (20.4) 2-in., Class 600 22 (10.0) N/A N/A N/A 3-in., Class 600 31 (14.1) 33 (15.0) 34 (15.4) 35 (15.9) DN 50, PN10-40 20 (9.1) N/A N/A N/A DN 80, PN 25/40 25 (11.3) 27 (12.3) 28 (12.7) 29 (13.2) DN 100, PN 10/16 25 (11.3) 28 (12.7) 30 (13.6) 32 (14.5) DN 100, PN 25/40 29 (13.2) 32 (14.5) 34 (15.4) 36 (16.3)
(1) Stainless steel flange weights are listed.
Flush lb. (kg)
2-in (50mm) Ext. lb. (kg)
4-in. (100mm) Ext. lb. (kg)
6-in. (150mm) Ext. lb. (kg)
Pressure-7
Page 8
Rosemount 1151
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009

Product Certifications

Approved Manufacturing Locations

Rosemount Inc. — Chanhassen, Minnesota, USA
Emerson Process Management GmbH & Co. — Wessling, Germany
Emerson Process Management Asia Pacific Private Limited — Singapore
Beijing Rosemount Far East Instrument Co., Limited – Beijing, China

European Directive Information

The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at www.rosemount.com. A hard copy may be obtained by contacting our local sales office.

ATEX Directive (94/9/EC)

Emerson Process Management complies with the ATEX
Directive.

European Pressure Equipment Directive (PED) (97/23/EC)

1151GP9, 0; 1151HP4, 5, 6, 7, 8 Pressure Transmitters — QS Certificate of Assessment - EC No. PED-H-100 Module H Conformity Assessment
All other 1151 Pressure Transmitters — Sound Engineering Practice
Transmitter Attachments: Diaphragm Seal - Process Flange ­Manifold — Sound Engineering Practice

Electro Magnetic Compatibility (EMC) (2004/108/EC)

All models — EN 61326: 1997 with Amendments A1, A2, and A3

Hazardous Locations Certifications

North American Certifications

Ordinary Location Certification for Factory Mutual

As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

Factory Mutual (FM) Approvals

FM Explosion-Proof tag is standard. Appropriate tag will be substituted if optional certification is selected.
Explosion-Proof: Class I, Division 1, Groups B, C, and D. Dust-Ignition Proof: Class II, Division 1, Groups E, F, and G; Class III, Division 1. Indoor and outdoor use. NEMA 4X. Factory Sealed.
I5 Intrinsically safe for Class I, II, and III Division 1, Groups A,
B, C, D, E, F, and G hazardous locations in accordance with entity requirements and Control drawing 01151-0214 and 00268-0031. Non- incendive for Class I, Division 2, Groups A, B, C and D hazardous locations.
For entity parameters see control drawing 01151-0214.

Canadian Standards Association (CSA) Approvals

E6 Explosion-Proof for Class I, Division 1, Groups C and D;
Class II, Division 1, Groups E, F, and G; Class III, Division 1 Hazardous Locations. Suitable for Class I, Division 2, Groups A, B, C, and D; CSA enclosure type 4X. Factory Sealed.
I6 Intrinsically safe for Class I, Division 1, Groups A, B, C, and
D hazardous locations when connected per Drawing 01151-2575. For entity parameters see control drawing 01151-2575. Temperature Code T2D.
Pressure-8

European Certifications

I1 ATEX Intrinsically Safe and Combustible Dust
(1151 Smart only) Certificate No.: BAS99ATEX1294X ATEX Marking II 1 GD EEx ia IIC T5 (-60°C EEx ia IIC T4 (-60°C
118 0
IP66

TABLE 8. IS Entity Parameters

Ui = 30 V Ii = 125 mA Pi = 1.0 W (T4) or 0.67 W (T5) Ci = 0.034 μF Li = 20 µH
Special Conditions for Safe Use (X)
The apparatus, is not capable of withstanding the 500V test as required by EN 50020: 1994. This must be taken into account when installing the apparatus.
Ta 40°C) Ta 80°C)
Page 9
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009
Rosemount 1151
N1 ATEX Type n and Combustible Dust
(1151 Smart only) Certificate No.: BAS 99ATEX3293X ATEX marking: II 3 GD EEx nL IIC T5 (-40°C EEx nL IIC T4 (-40°C Dust Rating: T90 °C (Ta = -20°C to 40°C)
= 45 Vdc Max
U
i
IP66
Special Conditions for Safe Use (x)
The apparatus is not capable of withstanding the 500V insulation test required by EN 50021: 1999. This must be taken into account when installing the apparatus.
E8 ATEX Flame-Proof
Certification Number CESI03ATEX037 ATEX Marking II 1/2 G EEx d IIC T6 (–40 ≤ Ta ≤ 40 °C) EEx d IIC T4 (–40 Ta 80 °C)
1180
V = 60 Vdc maximum
Ta 40°C) Ta 80°C)

Australian Certifications

Standards Association of Australia (SAA) Certification

E7 SAA Flame-proof
Certificate Number Ex 494X Ex d IIB + H DIP T6 IP65
Special Conditions for safe use (x):
For transmitters having NPT, PG or G cable entry threads, an appropriate flame-proof thread adaptor shall be used to facilitate application of certified flame-proof cable glands or conduit system.
T6
2
I7 SAA Intrinsically Safe
Certificate Number: Ex 122X Ex ia IIC T5 (T Ex ia IIC T4 (T
Special Conditions for Safe Use (x):
The equipment has been assessed to the entity concept and accordingly the following electrical parameters must be taken into account during installation.
amb
amb
= 40 °C) = 60 °C)

TABLE 9. Entity Parameters

Ui = 30V
= 125 mA
I
i
Pi = 1.0 W (T4) or 0.67W (T5)
= 14.8 nF
C
i
Li = 20 μH
N7 SAA Type n
Certificate Number: Ex 887X Ex n IIC T6 (T Ex n IIC T5 (T IP66
Special Conditions for safe use (x):
The equipment must be connected to a supply voltage which does not exceed the rated voltage. The enclosure end caps must be correctly fitted whilst the equipment is energized.
amb
amb
= 40 °C) = 80 °C)

Combination Certifications

Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types.
C6 Combination of I6 and E6,
K5 Combination of FM Approvals Explosion-Proof and I5.
K6 Combination of E6, I6, I1, and E8
Pressure-9
Page 10
Rosemount 1151
Flange Distance “A” Center to Center
Range inches mm
3, 4, 5 2.125 54
6, 7 2.188 56
8 2.250 57 9 2.281 58 0 2.328 59
Meter
Housing
Terminal Connections
this Side
¼–18 NPT on
Flanges for Pressure
Connection without
Flange Adapters
½–14 NPT on Flange
Adapters
A
(See Table)
4.5 (114) Max.
7.5 (191) Max.
with Optional Meter
0.75 (19) Clearance for Cover Removal (Typical)
Transmitter Circuitry this Side
1.625 (41)
Blank Flange Used on AP and GP Transmitters
Flange
Adapter
4.5
(114)
3.375 (86)
Flanges Can Be Rotated
3.69 (94)
4.5 (114) Max.
Permanent Tag (Optional)
Nameplate
Wired-on Tag
(Standard)
Drain/Vent
Valve
¼–18 NPT for
Side Drain/Vent
(Optional Top
or Bottom)
NOTE Dimensions are in inches (millimeters).
½–14 NPT
Conduit
Connection
(2 Places)
9.0 (229) Max.
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009

Dimensional Drawings

1151 Transmitter
Pressure-10
Page 11
Product Data Sheet
Smart
Electronics
Terminal Eyelets
Transmitter Security and Failure
Mode Alarm Switches
Zero and Span Buttons
Board
Spacers
Blank Flange for AP and GP
Process
Flange
-Cell
Sensing
Module
00813-0100-4360, Rev HA Catalog 2008 - 2009
Typical Transmitter Exploded View with Smart Electronics
Rosemount 1151
Pressure-11
Page 12
Rosemount 1151
C
B
DIAPHRAGM ASSEMBLY
AND MOUNTING FLANGE
NOTE Dimensions are in inches (millimeters).
Meter
Housing
Terminal Connections This Side
Nameplate (Remove for Span and Zero Adjust)
Transmitter Circuitry
This Side ½–14 NPT for Conduit Connection (2 places)
0.75 (19) Clearance for Cover Removal (typical)
½–14 NPT on Flange Adapters
¼–18 NPT on Flanges for Pressure Connection without the Use of Flange Adapters
Permanent Tag
(optional)
11.38 (289) Max.
Serrated Face Gasket Surface
E
D
A
Wired-on Tag
(standard)
Flange
Adapter
2-, 4-, or 6-in. (51, 102, or 152) Extension
4.5 (114) Max.
4.5 (114) Max.
4.45 (113) Max.
7.5
(190.5)
Max. with
Optional
Meter
Flushing
Connection
1
(25)
G
E
OPTIONAL FLUSHING
CONNECTION RING
(LOWER HOUSING)
Drain/Vent Valve
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009
1151LT
Pressure-12
Page 13
Product Data Sheet

3.75 (95)

1.65 (42)
3.87 (98)
2.81 (71)
NOTE Dimensions are in inches (millimeters).
4.97
(127)
2.62 (67)
2.625 (67)
5.625 (143)
2.625 (67)
5.625 (143)
00813-0100-4360, Rev HA Catalog 2008 - 2009

TABLE 10. 1151LT Dimensional Specifications

Class
ANSI 150 2 (51)
ANSI 300 2 (51)
ANSI 600 2 (51)
DIN
PN10-40
DIN
PN 25/40
DIN
PN 10/16
(1) Tolerances are 0.040 (1.02), –0.020 (0.51).
Pipe Size
3 (76)
4 (102)
3 (76)
4 (102)
3 (76)
DN 50 26 mm 125 mm 165 mm 4 18 mm NA 4.0 (102) 2.5 (63)
DN 80
DN 100 DN 100 26 mm 180 mm 220 mm 8 18 mm 89 mm 6.2 (158) 4.5 (114)
Flange
Thickness
A
1.12 (28)
1.31 (33)
1.31 (33)
1.25 (32)
1.50 (38)
1.62 (41)
1.12 (28)
1.37 (35)
30 mm 30 mm
Bolt Circle
Diameter
B
4.75 (121)
6.0 (152)
7.5 (191)
5.0 (127)
6.62 (168)
7.88 (200)
5.0 (127)
6.62 (168)
160 mm 190 mm
Outside
Diameter
C
6.0 (152)
7.5 (191)
9.0 (229)
6.5 (165)
8.25 (210)
10.0 (254)
6.5 (165)
6.62 (168)
200 mm 235 mm
No. of
Bolts
4 4 8
8 8 8
8 8
8 8
Bolt Hole Diameter
0.75 (19)
0.75 (19)
0.75 (19)
0.75 (19)
0.88 (22)
0.88 (22)
0.75 (19)
0.88 (22)
18 mm 22 mm
Rosemount 1151
O.D.
Exten.
Diam.
(1)
D
NA
2.58 (66)
3.5 (89) NA
2.58 (66)
3.5 (89) NA
2.58 (66)
65 mm 89 mm
Gask.
Surf.
E
3.6(92)
5.0 (127)
6.2 (158)
3.6(92)
5.0 (127)
6.2 (158)
3.6(92)
5.0 (127)
5.4 (138)
6.2 (158)
Proc.
Side
G
2.12 (54)
3.5 (89)
4.5 (114)
2.12 (54)
3.5 (89)
4.5 (114)
2.12 (54)
3.5 (89)
3.7 (94)
4.5 (114)
Mounting Bracket Option Codes B1, B4, and B7
Pressure-13
Page 14
Rosemount 1151

2.625 (67)

3.87 (98)
NOTE Dimensions are in inches
1.40 (36)
Mounting Holes
0.375 (10) Diameter
3.75 (95)
4.5
(114)
2.81 (71) Typ ica l
1.40 (46)
2.81 (71) Typical
2.81 (71) Typ ica l
1.65 (42)
8.0

(203)

1.62 (41)
2.81 (71)
2.125 (54)
NOTE Dimensions are in inches (millimeters).
Panel Mounting Bracket Option Codes B2 and B5
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009
Pressure-14
Flat Mounting Bracket Option Codes B3, B6, and B9
Page 15
Product Data Sheet
NOTE DImensions are in inches
OPTION CODE M4
LINEAR SCALE
OPTION CODE M1
LINEAR SCALE
7.5 (191) Max.
with Optional Meter
0.75 (19) Clearance for Cover Removal (Typical)
9.0 (229) Max.
Kynar
Insert
¼–18 or ½–14 NPT Process Connection
½–14 NPT Connection on Adapters
(Option code DF)
Standard Drain/Vent
Replaced with Plug
Alternate Side
Drain/Vent
Top Position
(Option Code D1)
Alternate Side Drain/Vent
Bottom Position
(Option Code D2)
00813-0100-4360, Rev HA Catalog 2008 - 2009
Rosemount 1151
Meter Options
Flange Insert 1151 Process Connections
Pressure-15
Page 16
Product Data Sheet
00813-0100-4360, Rev HA
Rosemount 1151
Catalog 2008 - 2009

Ordering Information

= Applicable — = Not Applicable
Model Transmitter Type DP HP GP AP
1151DP Differential Pressure Transmitter ——— 115 1HP Differential Pressure Transmitter for High Line Pressures — 1151GP Gage Pressure Transmitter —— 1151AP Absolute Pressure Transmitter
Code Pressure Ranges (URL) (select one) DP HP GP AP
3 30 inH2O (7.46 kPa) — 4 150 inH2O (37.3 kPa) 5 750 inH2O (186.4 kPa) 6 100 psi (689.5 kPa) 7 300 psi (2068 kPa) 8 1,000 psi (6895 kPa) 9 3,000 psi (20684 kPa) — 0 6,000 psi (41369 kPa) ——
Code Transmitter Output (select one) DP HP GP AP
S 4–20 mA with Digital Signal based on HART Protocol (Smart) •••• E 4–20 mA, Linear with Input
(1)
G
M
Code Flanges/Adapters Drains/Vents Diaphragms Fill Fluid DP HP GP
33
73 83
7B 8B
Code Mounting Brackets (optional - select one) DP HP GP AP
10–50 mA, Linear with Input ••••
L Low Power 0.8 to 3.2 Vdc
(2)
Low Power 1 to 5 Vdc ••••
MATERIALS OF CONSTRUCTION
52 Nickel-plated Carbon Steel 316 SST 316L SST Silicone 53 Nickel-plated Carbon Steel 316 SST Hastelloy C-276 Silicone •••• 55 Nickel-plated Carbon Steel 316 SST Tantalum Silicone 22 316 SST 316 SST 316L SST Silicone •••• 23 316 SST 316 SST Hastelloy C-276 Silicone 25 316 SST 316 SST Tantalum Silicone
(5)
Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 Silicone
35 Hastelloy C-276 Hastelloy C-276 Tantalum Silicone
(5)
316 SST Hastelloy C-276 Hastelloy C-276 Silicone
(5)
Nickel-plated Carbon Steel Hastelloy C-276 Hastelloy C-276 Silicone ••••
5A Nickel-plated Carbon Steel 316 SST 316L SST Inert 5B
Nickel-plated Carbon Steel 316 SST Hastelloy C-276 Inert
5D Nickel-plated Carbon Steel 316 SST Tantalum Inert 2A 316 SST 316 SST 316L SST Inert 2B 316 SST 316 SST Hastelloy C-276 Inert 2D 316 SST 316 SST Tantalum Inert 3B Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 Inert 3D Hastelloy C-276 Hastelloy C-276 Tantalum Inert
(5)
316 SST Hastelloy C-276 Hastelloy C-276 Inert
(5)
Nickel-plated Carbon Steel Hastelloy C-276 Hastelloy C-276 Inert
B1 Bracket, 2-in. Pipe Mount •••• B2 Bracket, Panel Mount B3 Bracket, Flat, 2-in. Pipe Mount •••• B4 B1 Bracket w/Series 316 SST Bolts B5 B2 Bracket w/Series 316 SST Bolts •••• B6 B3 Bracket w/Series 316 SST Bolts B7 316 SST B1 Bracket with 316 SST Bolts •••• B9 316 SST B3 Bracket with 316 SST Bolts
(3)
••••
••••
••
(4)
AP
Pressure-16
Page 17
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009
Rosemount 1151
Code Meters
(6)
(optional - select one) DP HP GP AP
M1 Analog Scale, Linear Meter, 0–100% M2 Analog Scale, Square Root Meter, 0–100% Flow ••——
(7)
M3
M4
M7
M8 M9
Analog Scale, Linear Meter, Special Scale
(8)
(9)
LCD Display, Linear Meter, 0–100%, User Selectable ••••
M6 Analog Scale, Square Root Meter, 1–10
(9)
LCD Display, Linear Meter, Special Configuration ••••
(9)
LCD Display Square Root Meter, 0–100% Flow
(9)
LCD Display, Square Root Meter, 0–10 ••——
Code Product Certifications DP HP GP AP
E8 ATEX Flameproof
(10)
I1
N1
I5 K5 C6
I6 K6
ATEX Intrinsic Safety
(10)
ATEX Type n ••••
(10)
FM Intrinsically Safe, Division 2
(10)
FM Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ••••
(10)
CSA Explosion-Proof, Intrinsically Safe
(10)
CSA Intrinsically Safe ••••
(10)
CSA Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2
NOTE
FM explosion-proof approval is standard.
••••
E6 CSA Explosion-Proof, Dust Ignition-proof, Division 2 •••• E7 SAA Flameproof, Dust Ignition-proof
(10)
I7 N7 C5
SAA Intrinsic Safety ••••
(10)
SAA Type n
(11)
Measurement Canada Accuracy Approval ••••
Code Housing (optional - select one) DP HP GP AP
(12)
H1 H2
SST Non-wetted Parts on Transmitter without Meter ••••
(12)
SST Non-wetted Parts on Transmitter with Meter H3 SST Housing, Covers, Conduit Plug, Lock-nut, without Meter •••• H4 SST Housing, Covers, Conduit Plug, Lock-nut, with Meter
(13)
C2
M20 Conduit Threads •••• J1 G½ Conduit Threads
Code Terminal Blocks (optional - select one) DP HP GP AP
R1 Integral Transient Protection (Only available with Option Code S and E electronics
Code Bolts for Flanges and Adapters (optional - select one) DP HP GP AP
L3 ASTM A193-B7 Flange and Adapter Bolts L4 316 SST Flange and Adapter Bolts •••• L5 ASTM A193-B7M Flange and Adapter Bolts
Code Process Connections (optional
D1 Side Drain/ Vent, Top 316 SST
(14)
) Materials DP HP GP AP
•••
Hastelloy C-276••••
D2 Side Drain/ Vent, Bottom 316 SST
•••
Hastelloy C-276••••
DF ½–14 NPT Flange adapter(s)- Material determined by flange material Carbon Steel
316 SST Hastelloy C-276
D4
D5
(15)
Conformance to DIN EN61518 Ranges 3, 4, 5 with ¼ NPT Process Connections
Thread (Available in Germany Only)
(15)
Conformance to DIN EN61518 Ranges 6, 7, 8, without ¼ NPT Process Connections
••——
Thread (Available in Germany Only) D6 316 SST Low Side Blank Flange —— •• D9 JIS Process Connection–RC ¼ Flange with RC ½ Flange
Adapter
Carbon Steel 316 SST Hastelloy C-276
G1 DIN Spacing (Single Entry Port, No Side V/D Hole Flange) •••• G2 DIN Spacing (Single Entry Port, Two Side V/D Hole Flange) G3 DIN Spacing (Dual Entry Port, No Side V/D Hole Flange) •••• G4 DIN Spacing (Dual Entry Port, One Top Side V/D Hole Flange) G5 DIN Spacing (Dual Entry Port, One Bottom Side V/D Hole Flange) •••• G6 DIN Spacing (Dual Entry Port, Two Side V/D Hole Flange)
Pressure-17
Page 18
Product Data Sheet
00813-0100-4360, Rev HA
Rosemount 1151
(16)
K1 K2
(17)(18)
S1
(17)(18)
S2
(18)(19)
S4
S6
Code Wetted O-ring Material (optional - select one) DP HP GP AP
W2 Buna-N W3 Ethylene-Propylene •••• W4 Aflas
W6 W7
Code Special Configuration (Software) DP HP GP AP
(23)(24)
CN
(23)(24)
C4
C9
Code Special Certifications DP HP GP AP
Q8
Q16 Surface Finish Certification for Sanitary Remote Seals
Code Toolkit Total System Performance Reports DP HP GP AP
Code Procedures (optional - select one) DP HP GP AP
P1 P2
Code Outputs (optional - select one) DP HP GP AP
V1 V2 V3
Typical Model Number: 1151DP 4 S 52 B3 M4
(1) Output Code G is not available with CE Mark. (2) Meter or SST housing not valid with this option. (3) Bolts and conduit plugs are plated carbon steel. (4) On GP and AP transmitters, the low-side flange is plated carbon steel. For a stainless-steel low-side flange, order process connection Option Code D6. (5) These selections meet NACE material recommendations per MR 01-75. (6) Not available with Output Codes L or M, or Option Codes V2 or V3. (7) Limited availability. Contact your Emerson Process Management representative. (8) Specify the range, mode, and engineering units. Also, the 20 mA value must be greater than the 4 mA value. (9) Not available with Output Codes G. (10) Not available with Output Codes E, G, L, or M. (11) Limited availability depending on transmitter type and range. Contact an Emerson Process Management representative. (12) Option includes SST housing, covers, conduit plug, locknut, L4 bolting, and D6 low side blank flange for GP and AP transmitters.
(13) Not available with Output Codes L or M. (14) Allowable combinations are: D1, D3, D6; D2, D3, D6; and D6, S1. (15) Material Traceability Certificate Option Q8 available. (16) The maximum working pressure on this option is 300 psig. Available only with materials of construction Option Code 2x. (17) This option may only be used on Ranges 4–8. (18) “Assemble-to” items are specified separately and require a completed model number. (19) This option has a maximum static pressure rating of 3,000 psi, and is available for factory assembly only without associated piping and is available only for
(20) Contains a Hastelloy spring that is wetted by the process; consult factory for PTFE O-ring without a spring. (21) Available for all the ranges of DP (3-8), HP (4-7), and AP (4-8), but it is only available for GP ranges 3-8. (22) PTFE O-ring has seal property limitations; Consult an Emerson Process Management representative for more information. (23) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field. (24) Available with Output Code S only. (25) This option is available for the transmitter flange and adapters. (26) Hydrostatic testing for Range 0, 125% maximum working pressure. (27) Fluorolube (28) Reverse output option is not needed with smart electronics; configured via HART-based communicator. (29) Not available with Output Codes L or M.
Kynar insert, ¼–18 NPT ••
(16)
Kynar insert, ½–14 NPT
Assemble to one Rosemount diaphragm seal
Assemble to two Rosemount diaphragm seals
Assemble to Rosemount 1195 Integral Orifice ———
(18)
Assemble to Rosemount 304 Manifold or Connection System
(20)(21)
Spring-loaded PTFE ••
(21)(22)
PTFE
Analog Output Levels Compliant with NAMUR Recommendation NE43: 27-June-1996 and Low Alarm Level
Analog Output Levels Compliant with NAMUR Recommendation NE43: 27-June-1996 and High Alarm
Level
(24)
Software Configuration (Requires completed Configuration Data Sheet)
Q4 Calibration Certificate
(25)
Material Traceability per EN 10204 3.1
QZ Remote Seal System Performance Calculation Report
(26)
Hydrostatic Testing, 150% Maximum Working Pressure ••••
(27)
Cleaning for Special Service P3 Cleaning for <1 PPM Chlorine/Fluorine ••••
(28)
Reverse Output
(29)
4–20 mV Test Signal ••••
(29)
20–100 mV Test Signal
Option Codes L4 and D6 parts are included with housing Option Codes H1 and H2.
Ranges 2, 3, 4, and 5.
®
grease on wetted O-rings.
Catalog 2008 - 2009
••••
Pressure-18
Page 19
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009
Model Product Description
115 1LT Flange-Mounted Liquid Level Transmitter
Code Pressure Range
4 150 inH2O (0–635 to 0–3,810 mmH2O) 5 750 inH2O (0–3,175 to 0–19,050 mmH2O) 6 2,770 inH2O (0–11.96 to 0–70.36 mmH2O)
Code Output
S 4–20 mA with Digital Signal based on HART Protocol (Smart) E 4–20 mA, Linear with Input
(1) (2)
G
Code Size Material Extension Length
Code Size Rating Material
10–50 mA, Linear with Input
G0 2 in./DN 50 316L SST Flush Mount Only When specifying these option codes, a lower H0 2 in./DN 50 Hastelloy C-276 Flush Mount Only J0 2 in./DN 50 Tantalum Flush Mount Only A0 3 in./DN 80 316L SST Flush Mount A2 3 in./DN 80 316L SST 2 in./50 mm A4 3 in./DN 80 316L SST 4 in./100 mm A6 3 in./DN 80 316L SST 6 in./150 mm B0 4 in./DN 100 316L SST Flush Mount B2 4 in./DN 100 316L SST 2 in./50 mm B4 4 in./DN 100 316L SST 4 in./100 mm B6 4 in./DN 100 316L SST 6 in./150 mm C0 3 in./DN 80 Hastelloy C-276 Flush Mount C2 3 in./DN 80 Hastelloy C-276 2 in./50 mm C4 3 in./DN 80 Hastelloy C-276 4 in./100 mm C6 3 in./DN 80 Hastelloy C-276 6 in./150 mm D0 4 in./DN 100 Hastelloy C-276 Flush Mount D2 4 in./DN 100 Hastelloy C-276 2 in./50 mm D4 4 in./DN 100 Hastelloy C-276 4 in./100 mm D6 4 in./DN 100 Hastelloy C-276 6 in./150 mm E0 3 in./DN 80 Tantalum Flush Mount Only F0 4 in./DN 100 Tantalum Flush Mount Only
MOUNTING FLANGE
M 2-in. Class 150 CS 2 in./DN 50
A 3-in. Class 150 CS 3 in./DN 80 B 4-in. Class 150 CS 4 in./DN 100 N 2-in. Class 300 CS 2 in./DN 50 C 3-in. Class 300 CS 3 in./DN 80 D 4-in. Class 300 CS 4 in./DN 100 P 2-in. Class 600 CS 2 in./DN 50 E 3-in. Class 600 CS 3 in./DN 80 X 2-in. Class 150 SST 2 in./DN 50 F 3-in. Class 150 SST 3 in./DN 80 G 4-in. Class 150 SST 4 in./DN 100 Y 2-in. Class 300 SST 2 in./DN 50 H 3-in. Class 300 SST 3 in./DN 80
J 4-in. Class 300 SST 4 in./DN 100 Z 2-in. Class 600 SST 2 in./DN 50 L 3-in. Class 600 SST 3 in./DN 80 Q DN 50 PN 10-40 CS 2 in./DN 50 R DN 80 PN 40 CS 3 in./DN 80 S DN 100 PN 40 CS 4 in./DN 100 V DN 100 PN 10/16 CS 4 in./DN 100 K DN 50 PN 10-40 SST 2 in./DN 50
Rosemount 1151
housing must be selected from the flushing connection options.

NOTE

Extension diameters are sized to fit Schedule 80 pipe. Consult factory for Schedule 40 pipe.
Applicable with these High Pressure Side Diaphragm Sizes
Pressure-19
Page 20
Rosemount 1151
T DN 80 PN 40 SST 3 in./DN 80 U DN 100 PN 40 SST 4 in./DN 100
W DN 100 PN 10/16 SST 4 in./DN 100
SENSOR MODULE AND LOW-SIDE MATERIALS OF CONSTRUCTION
Code
and Adapter
Drain/ Vent Valves
52 Nickel-plated CS 316 SST 316L SST Silicone 55 Nickel-plated CS 316 SST Tantalum Silicone 22 316 SST 316 SST 316L SST Silicone 23 316 SST 316 SST Hastelloy C-276 Silicone 25 316 SST 316 SST Tantalum Silicone 33 Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 Silicone 35 Hastelloy C-276 Hastelloy C-276 Tantalum Silicone 5D Nickel-plated CS 316 SST Tantalum Inert 2A 316 SST 316 SST 316L SST Inert 2B 316 SST 316 SST Hastelloy C-276 Inert 2D 316 SST 316 SST Tantalum Inert 3B Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 Inert 3D Hastelloy C-276 Hastelloy C-276 Tantalum Inert
Code Process Fill - High Pressure Side Temperature Limits
A Syltherm XLT –100 to 300 °F (–73 to 135 °C) C D. C. Silicone 704 60 to 400 °F (15 to 205 °C) D D. C. Silicone 200 –40 to 400 °F (–40 to 205 °C) H Inert –50 to 350 °F (–45 to 177 °C) G Glycerin and Water 0 to 200 °F (–17 to 93 °C) N Neobee M-20 0 to 400 °F (–17 to 205 °C) P Propylene Glycol and Water 0 to 200 °F (–17 to 93 °C)
Code Options
Low-Side Flange
(3)(4)
S1
M1
M3 M4 M7
Assemble to one Rosemount diaphragm seal
METERS
(5)
Linear Meter, 0–100% Scale
(5)
Special Scale Meter, Specify Range
(5)(6)
LCD Display, 0–100%
(5)(7)
LCD Display, Linear, Special Configuration
TERMINAL BLOCKS
R1 Integral Transient Protection (Available with output codes S and E only)
HARZARDOUS LOCATIONS CERTIFICATIONS
E8 ATEX Flameproof
(8)
I1
N1
I5 K5 C6
I6 K6
ATEX Intrinsic Safety
(8)
ATEX Type n
(8)
FM Intrinsically Safe, Division 2
(8)
FM Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(8)
CSA Explosion-Proof, Intrinsically Safe
(8)
CSA Intrinsically Safe
(8)
CSA Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2 E6 CSA Explosion-Proof, Dust Ignition-proof, Division 2 E7 SAA Flameproof, Dust Ignition-proof
(8)
I7 N7 C5
SAA Intrinsic Safety
(8)
SAA Type n
(9)
Measurement Canada Accuracy Approval
Low-Side Isolator Diaphragm
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009
Low-Side Fluid Fill

NOTE

FM explosion-proof approval is standard.
Pressure-20
Page 21
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009
OTHER OPTIONS
W5 Copper O-ring for Vacuum Service (Nonwetted)
C2 M20 Conduit Threads Q4 Calibration Data Sheet
(10)
Q8
Q16 Surface Finish Certification for Sanitary Remote Seals (all options)
Typical Model Number: 1151LT 4 S A0 A 52 D F1
(1) Not available with Output Codes E and G. (2) Output Code G is not available with CE Mark. (3) For welded capillary assemblies, order sensor module and low-side materials of construction Option Code 22 (refer to 00813-0100-4016 for more information). (4) “Assemble-to” items are specified separately and require a completed model number. (5) Not available with Option Codes Zx, V2, or V3. (6) Limited availability. Contact an Emerson Process Management representative. (7) Specify the Range, Mode, and Engineering Units. Also, the 20 mA value must be greater than the 4 mA value. (8) Not available with Output Codes E and G. (9) Limited availability depending on transmitter type and range. Contact an Emerson Process Management representative. (10) Available for the diaphragm, upper housing, flange, adapter, extension, and lower housing.
Material Traceability per EN 10204 3.1B
QZ Remote Seal System Performance Calculation Report V1 Reverse Output V2 4–20 mV Test Signal V3 20–100 mV Test Signal F_ Select One Code from Flushing Connections Lower Housing Option. See Table 11.
Rosemount 1151

TABLE 11. Flushing Connections Lower Housing Options

Flushing Connection Ring
Code
Material (Lower Housing)
F1 SST 1
F2 SST 2
F3
F4
(1)
(1)
Hastelloy C-276 1
Hastelloy C-276 2
F7 SST 1
F8 SST 2
F9 Hastelloy C-276 1
F0 Hastelloy C-276 2
(1) Not available with high pressure side Option Codes A0, B0, and G0.
Flushing
Connections
= Applicable — = Not Applicable
Diaphragm Size
Size
1
/4 - 18 NPT •••
1
/4 - 18 NPT
1
/4 - 18 NPT •••
1
/4 - 18 NPT
1
/2 - 14 NPT •••
1
/2 - 14 NPT
1
/2 - 14 NPT •••
1
/2 - 14 NPT
2-in. 3-in. 4-in.
Pressure-21
Page 22
Rosemount 1151
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009

Standard Accessories

All models are shipped with drain/vent valves, and one instruction manual per shipment.
Tagging
The transmitter will be tagged, at no charge, in accordance with customer requirements. All tags are stainless steel. The standard tag is wired to the transmitter, however a permanently attached tag is available upon request. Tag character height is 0.125 in. (0.318 cm).
Calibration
Transmitters are factory calibrated to the customer’s specified range. If calibration is not specified, the transmitters are calibrated at maximum range. Calibration is performed at ambient temperature and pressure.

Options

The following sections describe a variety of available options for the 1151 Transmitter. These options permit greater application flexibility.
Optional Manifolds
Refer to Manifold Product Data Sheet (document number 00813-0100-4839).
Optional Diaphragm and Sanitary Seals
Refer to Product Data Sheet (document numbers 00813-0100-4016 or 00813-0201-4016)
Mounting Brackets
B1 Bracket for 2-in. Pipe Mounting
• Bracket for mounting transmitter on 2-in. pipe
• Constructed of carbon steel with carbon steel U-bolt
• Coated with polyurethane paint
B4 Bracket for 2-in. Pipe with 316 SST Bolts
• Same bracket as Option Code B1 with 316 SST bolts
B7 304 SST Bracket and 316 SST Bolts for 2-in. Pipe Mounting
• Same bracket as Option Code B1 with all SST materials
B2 Bracket for Panel Mounting
• Bracket for mounting transmitter on panel or wall
• Constructed of carbon steel with carbon steel bolts
• Coated with polyurethane paint
B5 Bracket for Panel with 316 SST Bolts
• Same bracket as Option Code B2 with 316 SST bolts
B3 Flat Bracket for 2-in. Pipe Mounting
• Bracket for vertical mounting of transmitter on 2-in. pipe
• Constructed of carbon steel with carbon steel U-bolt
• Coated with polyurethane paint
B6 Flat Bracket for 2-in. Pipe with 316 SST Bolts
• Same bracket as Option Code B3 with 316 SST bolts
B9 304 SST Flat Bracket and 316 SST Bolts for 2-in. Pipe Mounting
• Same bracket as Option Code B3 with all 316 SST materials
Bolts and Nuts for Flanges and Adapters
Options permit bolts and nuts for flanges and adapters in the specified material.
• L3 ANSI/ASTM A - 193-B7
• L4 Austenitic 316 SST
• L5 ANSI/ASTM A193-B7M
Meters
Analog
• Meters have 2-in. (50.8 mm) scale
• Plug-in mounting configuration
• Indication accuracy ±2%
• Operating temperature limit: –40 to 150 °F (–40 to 65 °C)
• Meters are enclosed in a housing certified by Factory Mutual as Explosion-Proof for Class I, Division 1, Groups B, C, and D; Class II, Division 1, Groups E, F, and G and Class III, Division 1
• For optional CSA explosion-proof approval, see certification Option Code E6
• M1 Linear Analog Meter, 0–100% Scale
• M2 Square Root Analog Meter, 0–100% Flow Scale
• M3 Special Scaling Analog Meter (Specify Range)
• M6 Square Root Analog Meter, 0–
LCD
• 4-digit display
• Indication accuracy ±0.25% of calibrated span ±1 digit
• Display resolution at ±0.5% of calibrated span ±1 digit
• Operating temperature limit: –4 to 158 °F (–20 to 70 °C)
• Plug-in mounting configuration
• Meters are enclosed in a housing certified by FM as Explosion-Proof for Class I, Division 1, Groups B, C, and D; Class II, Division 1, Groups E, F, and G and Class III, Division 1
• For Optional CSA explosion-proof approval, see certification Option Code E6
• Reverse output not available with LCD Display
• M4 Linear LCD Meter, 0 to 100%
• M7 Special Scale LCD Display (Specify Range, Mode, and Engineering Units)
• M8 Square Root LCD Display, 0 to 100%
• M9 Square Root LCD Display, 0–10
NOTES
Meter Options are not available with Output Codes L or M, or Option Codes V2 or V3. Meter Options M4, M7, M8, and M9 are not available with Output Code G.
10 Scale
Scale
Process Connections
D1 Side Drain/Vent-Top
• Drain/vent valve mounted in side of flange.
• Top position used to vent gas buildup in liquid process applications with transmitter mounted vertically.
Pressure-22
• Plug of same material as requested flange inserted in end of flange opposite adapter.
Page 23
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009
Rosemount 1151
D2 Side Drain/Vent-Bottom
• Drain/vent valve mounted in side of flange.
• Bottom position used to drain liquid buildup in gas process applications with transmitter mounted vertically.
• Plug of same material as requested flange inserted in end of flange opposite adapter.
D6 316 SST Low Side Flange (1151GP and 1151AP Only)
1
/2–14 NPT flange adapters
DF
• Options provide rather than
1
/4–18 NPT Kynar™ Process Flange Insert
K1
1
/2–14 NPT Kynar Process Flange Insert
K2
• Options provide Kynar plastic process flange insert that prevents process from coming in contact with the metal of the flange. One process insert for the 1151GP and LT; two inserts for the 1151DP.
• Process connections are from the side.
• Available with carbon steel and stainless steel process flanges only.
• Pressure Maximum: 200 psi at 200 °F with Kynar impulse piping; 300 psi at 200 °F with metal impulse piping.
S1 Assembled with One Remote Diaphragm Seal
S2 Assembled with Two Remote Diaphragm Seals
• Options provide for the assembly of one or two remote diaphragm seals.
S4 Assembled with 1195 Integral Orifice
• Designed for highly accurate, small-bore flow measurement of any clean gas, liquid, or vapor.
• Reduce the costs associated with traditional orifice plate installations.
• Several configurations are available factory assembled to Rosemount differential pressure transmitters.
• Wide orifice bore/flow range capability.
• Wide choice of process connections, including threaded, socket weld, and ANSI flanges.
• Static pressure maximum limit is 3,000 psig.
• Wetted materials are available that comply with NACE MR 01-75(90).
• Available only with Ranges 2, 3, 4, and 5.
(1) Applicable only to orifice assemblies without piping.
1
/2–14 NPT process connection on flanges
1
/4–18 NPT
(1)
Wetted O-rings
• Standard: Viton®
• W2 Buna N
• W3 Ethylene-Propylene
•W4 Aflas
• W5 Copper O-ring for Vacuum Service (Nonwetted - 1151LT only)
• W6 Spring-Loaded PTFE
Contains a Hastelloy spring that is in contact with the
• W7 PTFE
®
process fluid. Consult factory if Hastelloy is unacceptable.
Procedures
Standard Configuration
Unless otherwise specified, transmitter will be shipped as follows:
Engineering Units: inH2O 4 mA: 0 20 mA: Upper Range Limit Output: Linear Software Tag: Blank
Customer may specify the above items at no charge. Software tag (8 characters) is left blank unless specified.
C9 Custom Configuration (Option Code C9)
If Option Code C9 is ordered, the customer may specify the following data in addition to the standard configuration parameters.
Descriptor: 16 characters Message: 32 characters Date: Day, Month, Year Damping: Seconds Burst Mode: Select Output Choice Failure Mode: High or Low Transmitter Security: Off or On
Pressure-23
Page 24
Rosemount 1151
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009

TABLE 12. Hydrostatic Test Pressure

Model Test Pressure
1151DP 3,000 psi 1151HP 6,750 psi 1151AP 2,000 psi 1151GP
Ranges 3–8 2,000 psi Range 9 4,500 psi Range 0 7,500 psi
1151LT
Class 150 Flange 450 psi Class 300 Flange 1,100 psi
P1 Hydrostatic Testing
• Each transmitter is hydrostatic tested according to Table 12.
• Test medium is water.
• This option provided for transmitters with remote diaphragm seal on application only.
• Rosemount Procedure 1746 outlines the testing procedure.
P2 Cleaning for Special Service
• This option minimizes contaminants to the process system by cleaning wetted surfaces with a suitable detergent.
• Rosemount Procedure 97412 outlines the cleaning procedure.
P3 Cleaning for <1 PPM Chlorine/Fluorine

Outputs

V1 Reverse Output
• This option permits reversing of pressure input so that electrical output will increase as pressure input decreases.
• This option applies only to 1151GP and 1151LT. When this option is selected, the process flange, adapter, drain/vent valve, appropriate O-rings, and bolting are installed on low side of transmitter. Not available for Ranges 9 and 0.
• Not available with 1151AP. Reverse output on 1151DP and 1151HP can be obtained by connecting high-pressure input to low side of transmitter and vice versa.
• This option should not be ordered with smart transmitters (Output Code S). The 1151 Smart transmitter can be configured for reverse output through a HART-Compatible Interface.
V2 1 Test Resistor
•A 1 precision resistor is mounted across the test terminals to provide 4–20 mV output or a 10–50 mV output if 10–50 mA output is used.
• This option cannot be used with any meter options or Option Codes I5 or I6.
V3 5 Test Resistor
•A 5 precision resistor is mounted across test terminals to provide 20–100 mV output or a 50–250 mV output if 10–50 mA output is used.
• This option cannot be used with any meter options or Option Codes I5 or I6.
Pressure-24
Page 25
Product Data Sheet
00813-0100-4360, Rev HA Catalog 2008 - 2009
Rosemount 1151
Pressure-25
Page 26
Rosemount 1151
Product Data Sheet
00813-0100-4360, Rev HA
Catalog 2008 - 2009
Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount, Annubar, ProPlate, and the Rosemount logotype are registered trademarks of Rosemount Inc. HART is a registered trademark of the HART Communication Foundation. δ-Cell is a trademark of Rosemount Inc. Fluorolube is a registered trademark of Hooker Chemical Co. Viton is a registered trademark of E.I. du Pont de Nemours & Co. Neobee M-20 is a registered trademark of Stepan Chemical Co. Syltherm and D.C. are registered trademarks of Dow Corning Corp. Aflas is a registered trademark of Asahi Glass Co., Ltd. Kynar is a trademark of Pennwalt Inc..
Emerson Process Management
Rosemount Inc.
8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1 800 999 9307 T (International) (952) 906 8888 F (952) 949 7001
www.rosemount.com
Emerson Process Management
Heath Place Bognor Regis West Sussex PO22 9SH England T 44 (0) 1243 863121 F 44 (0) 1243 867554
Emerson Process Management Asia Pacific Private Limited
1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.EmersonProcess.com
¢00813-0100-4360@¤
© 2008 Rosemount Inc. All rights reserved.
Loading...