Rosemount 114C Specifications

Rosemount™ 114C Thermowells
Product Data Sheet
June 2019
00813-0200-4952, Rev EB
Wide variety of industry standard process connections including flanged, threaded, welded, and Van
Stone.
exotic materials such as duplex and alloy C-276.
Additional thermowell options and certificates available.
Rosemount 114C
Contents
June 2019
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Rosemount 114C Threaded Thermowells . . . . . . . . . . . . 6
Threaded thermowell overview . . . . . . . . . . . . . . . . . . . 7
Threaded ordering information . . . . . . . . . . . . . . . . . . . 7
Threaded thermowell drawings . . . . . . . . . . . . . . . . . . 16
Rosemount 114C Flanged Thermowells . . . . . . . . . . . . 18
Flanged thermowell overview . . . . . . . . . . . . . . . . . . . 19
Flanged ordering information . . . . . . . . . . . . . . . . . . . 21
Flanged thermowell drawings . . . . . . . . . . . . . . . . . . . 30
Rosemount 114C Van Stone Thermowells . . . . . . . . . . .33
Van Stone thermowell overview . . . . . . . . . . . . . . . . .34
Van Stone ordering information . . . . . . . . . . . . . . . . .36
Van Stone thermowell drawings . . . . . . . . . . . . . . . . .44
Rosemount 114C Welded Thermowells . . . . . . . . . . . . .46
Welded thermowell overview . . . . . . . . . . . . . . . . . . .47
Welded ordering information . . . . . . . . . . . . . . . . . . . 49
Weld-in Type 4 thermowells according to DIN 43772 .55
Welded thermowell drawings . . . . . . . . . . . . . . . . . . .57
Ordering information detail . . . . . . . . . . . . . . . . . . . . . . .59
2
Emerson.com/Rosemount
June 2019
Rosemount 114C

Rosemount 114C Thermowell

Product overview

Temperature sensors are rarely inserted directly into an industrial process. They are installed into a thermowell to isolate them from the potentially damaging process conditions of flow-induced stresses, high pressure, and corrosive chemical effects. Thermowells are closed-end metal tubes or barstock installed into the process vessel or piping and become an integral pressure-tight part of the process vessel or pipe. They permit the sensor to be quickly and easily removed from the process for calibration or replacement without requiring a process shutdown and possible drainage of the pipe or vessel.
The Rosemount 114C Thermowell is made from solid barstock to ensure strength and integrity. The Rosemount 114C was designed to accommodate a host of industry standard configurations, but has the flexibility to adapt to special configurations for different types of applications.

Flexible design modifiers accommodate many process requirements

Different sizes of root (A), tip (B), and bore (d) diameters
Different tip (t) thickness as required
Numerous combinations for various industrial applications
Meet ASME PTC 19.3 TW standard with flexible design
A
B
t
d

Thermowell calculations ensure thermowell design is compatible with process conditions

Thermowells inserted into any process are subjected to forces
from the fluid flow.
ASME released design standard PTC 19.3 TW that defines a
series of qualitative calculations to determine design suitability to withstand process conditions.
Calculations are based on process conditions, process fluid,
installation method, thermowell geometry and material.
The thermowell calculation tool from Emerson is designed to
meet the ASME standard.
The free online software version can be used for preliminary
calculations. Click here to access the tool.
Formal calculations by our expert team of engineers are
available prior to order placement to ensure design is acceptable.
Recommendations are also made if thermowell design is found
to be unacceptable for the application.
Order Thermowell Calculation option (R21) to receive a formal
report with product shipment.
Figure 1. Thermowell Calculation Report (R21)
Emerson.com/Rosemount
3
Rosemount 114C
June 2019

Wide range of thermowell options and certificates for any application

Options for special testing requirements, such as External Hydrostatic Pressure Test (Q5) and Dye Penetration Test (Q73)
Options to ensure material traceability or compatibility, including Positive Material Identification or PMI (Q76), Material
®
Certification (Q8), Thermowell X-ray/Radiograph (Q81), and NACE
Options for special processing requirements such as Electropolishing (R20)
Approval (Q35)

Experience global consistency and local support from numerous worldwide Emerson manufacturing sites

World-class manufacturing provides globally consistent product
from every factory and the capacity to fulfill the needs of any project, large or small.
Experienced Instrumentation Consultants help select the right
product for any temperature application and offer advice on best installation practices.
An extensive global network of Emerson service and support
personnel can be on-site when and where they are needed.

Explore the benefits of a Complete Point Solution™ from Emerson

An “Assemble Sensor to Specific Transmitter” and “Assemble Sensor to Specific Thermowell” option enables Emerson to provide a
Complete Point Solution for measuring temperature, delivering an installation-ready transmitter, sensor, and thermowell assembly.
Emerson has a complete portfolio of Single Point and Multi-Input Temperature Measurement solutions, allowing effective
measurement and process control with reliable Rosemount products.
4
Emerson.com/Rosemount
June 2019
UH
L
Rosemount 114C

Selection guide

Ensure sensor fits thermowell

Rosemount 114C Head length (H) + Immersion length (U) = Rosemount 214C Sensor insertion length (L).

Basic selection guide

Selecting the proper thermowell for an application is an important activity as it impacts plant safety and measurement efficiency. Thermowells are considered a wetted part; they physically become part of the pressure retaining system.
The four major factors to consider when selecting a thermowell for an application are described below:
Thermowell length
There is no standard formula to determine thermowell immersion length. However, there are a few common practices that the process industry follows along with good engineering judgment. Ideally the thermowell tip should be located near the centerline in turbulent flow conditions because this represents the most accurate process temperature.
To ensure optimal performance, a general guideline for immersion length into a pipe is as follows:
10 the thermowell root diameter for air or gas
5 the thermowell root diameter for liquids
Another guideline is at least one-third the way into the pipe for any measurement. The American Petroleum Institute (API) has a specific recommendation of using an immersion length of the sensing element plus 50 mm (2-in.).
Mounting configuration
Consider how the thermowell is mounted on the pipe or tank. The process designer typically specifies what mating connection will be used and the thermowell selected should match that connection. Temperature, pressure, and material are usually taken into consideration to ensure the process connection will be adequate for the application. Welded, threaded, flanged, and Van Stone are standard mounting configuration options.
Thermowell stem profile
Factors to be considered when selecting a stem style include the process pressure, required response speed of the measurement, drag force of the fluid flow on the well, and the wake frequency. The stem or shank is the part of a thermowell inserted into the process piping or vessel. Straight, stepped and tapered stem styles are available. Each profile has its advantages depending on the need and situation.
Thermowell material
Rosemount Thermowells are supplied in most materials required for industrial applications. Standard materials are 316/316L Stainless Steel, 304/304L Stainless Steel, and A105 Carbon Steel. For corrosive environments, special materials such as Alloy C-276 and Alloy 600 are also available. See the ordering table for a complete listing of standard materials. Contact your local Emerson representative for additional material availability.
Emerson.com/Rosemount
5
Rosemount 114C

Rosemount 114C Threaded Thermowells

June 2019
6
Emerson.com/Rosemount
June 2019
Model
Instrument
connection threads
Head
length (H)
Thermowell
material
Stem
style
Process
connection
Mounting
style
Immersion
length (U)
Units
114C X XXXXXXXXXTXXXX
16151413121198765432110 191817
(5) Units
English (E)
Metric (M)
(6-9) Immersion length (U)
25 to 1165 mm (M) Example: 25 mm = 0025, 1165 mm =1165
1- to 42-in. (E) Example: 2-in. = 0020, 42-in. =0420
XXXX
XXXX
(10) Mounting style
Threaded (T)
(11-12) Process connections
AA ½-14 NPT
AB AC
¾-14 NPT
1-11.5 NPT
(13) Stem style
1
Straight stem
2 3
Tapered stem
Stepped stem
(14-15) Thermowell material
SC 316/316L SST
SF CS
304/304L SST
Carbon steel
(16-18) Head length (H)
40 to 225mm (M) Example: 40 mm = 040, 225 mm =225
1.75- to 11.25-in. (E) Example: 1.75.in = 017, 10-in. = 100
XXX
XXX
(19) Instrument connection
A
½-14 NPT
B
½-14 NPSM
Options
XX, XXX, XX
Common options
External pressure test
Q5
R21
Q35
Q8
NACE certification Thermowell
calculation
Material certification
DA M20 x 1.5p
DB DE
M24 x 1.5p
½-in. BSPF (G½)
D
M18 x 1.5p
E
M20 x 1.5p
F
M24 x 1.5p
Rosemount 114C

Threaded thermowell overview

Threaded thermowells are threaded into a process pipe or tank, allowing for easy installation and removal when necessary. While this is a common mounting method, it has the lowest pressure rating of all mounting configuration options.
Figure 2. Standard Offering–Threaded
The common options shown in Figure 2 represent a partial offering; reference the Rosemount 114C Threaded Ordering Information for a full list of available options.
Figure 3. Threaded Thermowell Components
A
A. Instrument connection B. Process connection
Note
Wetted surface includes engaged threads and immersion length (U).
Emerson.com/Rosemount
H
Tapered threads Parallel threads
B
U
A
H. Head length U. Immersion length
HU
B
7
Rosemount 114C
June 2019
Use the form below to record your model code:
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Instrument connection
Options
114C T
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 X X X X X
8
Emerson.com/Rosemount
June 2019
U

Threaded ordering information

Figure 4. Model Number Ordering Example
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Rosemount 114C
Instrument connection
Options
114C E 0060 T A A 1 S C 0 5 0 A
1234 5 6789 10 11 12 13 14 15 16 17 18 19 X X X X X
WR5,
Q76...
The numbers below the model number ordering example correlate to the character place numbers in the second column of the ordering table.
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
1-4
Place #
Model Details
Barstock temperature
114C
thermowell
Dimension units
5
E English units (in.)
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip wall thickness of 0.25-in. (6.4 mm)
Ref.
page
N/A
Ref.
page
59
Specifies whether length units will be in inches (in.) or millimeters (mm)
M Metric units (mm) 59
Tapered threads Parallel threads
Place #s
6-9
Immersion length (U)
U
Ref.
page
xxxx
Example of a 6.25-in. length where the second decimal is dropped off: 0062
xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
xxx.x-in., 1.00 to 100-in. in 1/4-in. increments (when ordered with dimension units code E)
xxxx
Example of a 50 mm length: 0050
Place #
10
Place #s
11-12
Emerson.com/Rosemount
Mounting style
T Threaded N/A
Process connection
1
AA
AB
AC 1–11.5 NPT Taper ed threads N/A
AD 11/2–11.5 NPT Taper ed threads N/A
AE
/2–14 NPT Taper ed threads N/A
3
/4–14 NPT Taper ed threads N/A
1
/2-in. BSPT Tap ered t hreads N/ A
59
59
Ref.
page
Ref.
page
9
Rosemount 114C
June 2019
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
3
AF
/4-in. BSPT Tap ered t hreads N/ A
AG 1-in. BSPT Taper ed threads N/A
DA M20 1.5p Parallel threads N/A
DB M24 1.5p Parallel threads N/A
DC M27 2p Parallel threads N/A
DD M33 2p Parallel threads N/A
1
DE
DF
/2-in. BSPF (G1/2) Parallel threads N/A
3
/4-in. BSPF (G3/4) Parallel threads N/A
DG 1-in. BSPF (G1) Parallel threads N/A
Place #
13
Stem style Details Image
Minimum immersion length
1 Straight
1-in. (25 mm) - Tapered threads
1.75-in. (45 mm) - Parallel threads
Minimum immersion length
2 Tap e re d
1-in. (25 mm) - Tapered threads
1.75-in. (45 mm) - Parallel threads
Minimum immersion length
3 Stepped
3-in. (75 mm) - Tapered threads
3.75-in. (95 mm) - Parallel threads
Place #s
14-15
Thermowell material Details
SC 316/316L dual rated 61
SD 316/316L dual rated (NORSOK) Must order the Q8 Material Certificate to get NORSOK documentation 62
SF 304/304L dual rated 61
CS Carbon steel (A-105) 61
SG 316Ti SST 61
SL 310 SST 61
SM 321 SST 61
Ref.
page
60
60
60
Ref.
page
SN 321H SST 61
SR 904L SST 61
SP 347 SST 61
AB Alloy B3 61
AC Alloy C-276 61
AG Alloy 20 62
AH Alloy 400 61
AK Alloy 600 61
10
Emerson.com/Rosemount
June 2019
H
Rosemount 114C
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
AM Alloy 601 61
AN Alloy 625 61
AP Alloy 800 61
AQ Alloy 800H/HT 61
AR Alloy 825 61
AU Alloy C-202 61
AS Alloy F44 Mo6 61
MO Molybdenum 61
Chrome-Moly Grade B-11/F-11
CA
Class II
Chrome-Moly Grade B-22/ F-22
CB
Class III
61
61
CC Chrome-Moly Grade F-91 61
NK Nickel 200 61
TT Titanium Grade 2 61
DS Super duplex SST Grade F-53 61
Super duplex SST Grade F-53 –
DT
NORSOK
Must order the Q8 Material Certificate to get NORSOK documentation 62
DU Duplex 2205 Grade F51 61
Duplex 2205 Grade F51 –
DV
NORSOK
Must order the Q8 Material Certificate to get NORSOK documentation 62
Tapered threads Parallel threads
Place #
16-18
xxx
xxx
Head length (H)
xx.x-in., 1.75 to 11.25-in. in 1/4-in. increments (when ordered with dimension units code E)
Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 1.75-in.)
xxx mm, 40 to 225 mm in 5 mm increments (when ordered with dimension units code M)
Example of a 50 mm length: 050 (default head length = 45 mm)
H
Ref.
page
63
63
Emerson.com/Rosemount
11
Rosemount 114C
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
June 2019
Place #
19
Instrument connection Details Image
1
A
B
C
D M18 1.5p 64
E M20 1.5p 64
F M24 1.5p 64
G G 1/2-in. (BSPF) 64
H G 3/4-in. (BSPF) 64
J M27 2p 64
K M14 1.5p 64
/2–14 NPT
1
/2–14 NPSM 64
3
/4–14 NPT 64
Female threads
Options (include with selected model number)
Sensor/thermowell assemble to options
Hand tight assembly of sensor
XT
and thermowell
Process-ready assembly of
XW
sensor and thermowell
Details
Ensures sensor is threaded into thermowell but only hand tightened 65
Ensures sensor is threaded into thermowell and torqued for process-ready installation
Ref.
page
64
Ref.
page
65
Extended product warranty
WR3 3-year limited warranty
WR5 5-year limited warranty 65
This warranty option extends manufacturer’s warranty to three or five years for manufacturer related defects
Thermowell calculation
R21 Thermowell calculation Set of calculations to ensure thermowells are safe in certain process conditions 65
NACE certification
Q35 NACE certification Meets MR0175/ISO 15156 and MR0103 requirements 66
PMI testing
Q76 PMI testing Verifies chemical composition of material 66
Material certification
Q8 Material certification
Certificate for material conformance and traceability in accordance with EN 10204 type 3.1
Ref.
page
65
Ref.
page
Ref.
page
Ref.
page
Ref.
page
67
12
Emerson.com/Rosemount
June 2019
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Rosemount 114C
Material tests
M01 Low temperature Charpy Test Measures the low temperature ductility of the material 67
M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 67
Surface finish Details
Q16 Certification Certificate showing measured surface finish values 68
R14 Finish < Ra 0.3 μm (12 μin) Improves surface roughness of thermowell 68
Electropolish
R20 Electropolish Improve smoothness and surface quality 68
Hydrostatic external pressure test
Q5 Standard external pressure test
Q9 Extended external pressure test Same as standard external pressure test but tested twice as long 69
Verifies structural quality and checks for leaks at thermowell process connection and stem
Hydrostatic internal pressure test
Ref.
page
Ref.
page
Ref.
page
Ref.
page
68
Ref.
page
Q85 Standard internal pressure test Verify internal structural integrity of thermowell 69
Q86 Extended internal pressure test Same as standard internal pressure test but tested twice as long 70
Canadian Registration Number
Q17 Canadian Registration Number Canadian approvals for all provinces (Approved materials in reference section) 70
Dye penetration test
Q73 Dye penetration test Checks quality of material 70
Wall thickness test
Q83 Ultrasonic test Checks the bore concentricity of the thermowell 71
Q84 Radiography (X-ray) test Checks the bore concentricity of the thermowell 72
Special cleaning
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 71
Thermowell markings
Ref.
page
Ref.
page
Ref.
page
Ref.
page
Ref.
page
R40 Test markings on thermowell
Emerson.com/Rosemount
External marking of the thermowell for specific tests (see reference page for list of tests)
71
13
Rosemount 114C
A
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
June 2019
Plug and chain
R06 Stainless steel Protects thermowell threads when sensor is not installed 73
R23 Brass Protects thermowell threads when sensor is not installed 73
Spherical tip
R60 Spherical tip Changes the flat tip to spherical 72
Vent hole
R11 Vent hole
Allows for the venting of a thermowell and for indication that thermowell structural integrity has been compromised
Thermowells with wrench flats
R37 Thermowells with wrench flats
Converts the two wrench flats to hex wrench flats; only applies to exotic materials
Root diameter (A)
Ref.
page
Ref.
page
Ref.
page
73
Ref.
page
79
Ref.
page
x.xx-in., 0.36 to 3.15-in. in 0.01-in. increments (when ordered with dimension units code E)
Axxx
Examples: Code A040 = 0.4-in., Code A315 = 3.15-in.
xx.xx mm, 10 to 80 mm in 0.5 mm increments (when ordered with dimension units code M)
Axxx
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm
Tip diameter (B)
x.xx-in., 0.36 to 1.83-in. in 0.01-in. increments (when ordered with dimension units code E)
Bxxx
Examples: Code B040 = 0.4-in., Code B180 = 1.80-in.
xx.xx mm, 10 to 46 mm in 0.5-mm. increments (when ordered with dimension units code M)
Bxxx
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm
B
Non-standard bore diameter (d) Details Image
D01 0.276-in./7.0 mm
d
D03 0.138-in./3.5 mm 82
D04 0.386- in./9.8 mm 82
D05 0.354-in./9.0 mm 82
D06 0.433-in./11.0 mm 82
Default = 0.26-in. (6.6 mm)
80
80
Ref.
page
81
81
Ref.
page
82
14
Emerson.com/Rosemount
June 2019
t
A
B
C
D
C
Rosemount 114C
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Non-standard tip thickness (t)
Ref.
page
T01 0.197-in./5.0 mm
Default = 0.25-in. (6.4 mm)
T02 0.236-in./6.0 mm 82
Threaded installation
Threaded thermowells are screwed into the process using a threaded fitting or directly into a tapped pipe if there is sufficient wall thickness. Tapered threads will deform to each other to create a seal. Thread sealant and appropriate torque should be applied to reduce risk of leaks.
Figure 5. Installation Components
82
A. Thermowell B. Threaded fitting C. Weld D. Process
Emerson.com/Rosemount
15
Rosemount 114C
.75 (19)
2.5 (63.5)
N
P
H
U
d
t
A
B
A
B
C
E
A

Threaded thermowell drawings

June 2019
Figure 6. Thread Mount Thermowell Drawings (Tapered Thread)
Straight Tapered Stepped
A. Root diameter B. Tip diameter C. Total length (U + H) E. Wrench allowance F. Thread allowance H. Head length
(1)
N. Instrument connection P. Process connection U. Immersion length d. Bore diameter t. Tip thickness
Table 2. Thread Mount Thermowells (Tapered Thread)
Code T, threaded
mounting style
Code
Process
connection “P”
AA
AB
AC 1–11.5 NPT 1.34 (34) 1
AD 1
AE
AF
AG 1-in. BSPT 1.34 (34) 1
1. Dimensions are in inches (millimeters).
1. Total length = U+ H.
16
1
/2–14 NPT 1.18 (30) 11/8 (28.6) 0.67 (17) 0.67 (17) 0.50 (12.7) 0.669 (17)
3
/4–14 NPT 1.18 (30) 11/8 (28.6) 0.75 (19) 0.89 (22.5) 0.63 (16) 0.71 (18)
1
/2–11.5 NPT 1.89 (48) 13/4 (44.5) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18)
1
/2-in. BSPT 1.18 (30) 11/8 (28.6) 0.67 (17) 0.67 (17) 0.50 (12.7) 0.669 (17)
3
/4-in. BSPT 1.18 (30) 11/8 (28.6) 0.75 (19) 0.89 (22.5) 0.63 (16) 0.71 (18)
Wrench flat size “G”
Metric units
(code M)
English units
(code E)
1
/4 (31.8) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18)
1
/4 (31.8) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18)
(1)
Root diameter
stepped stem
Root diameter
tapered stem
Tip diameter
tapered stem
Root diameter
straight stem
Thread
specification
NPT per SAE -AS
71051
(reference PS-71)
THD per ISO 7/1 (BS
21)
Emerson.com/Rosemount
June 2019
F
2.50 [63,5]
STEP LENGTH
N
P
H
U
d
t
B
B
A
A
C
A
Rosemount 114C
Figure 7. Thread Mount Thermowell Drawings (Parallel Thread)
Straight Tapered Stepped
A. Root diameter B. Tip diameter C. Total length (U + H) F. Hex size H. Head length
(1)
N. Instrument connection P. Process connection U. Immersion length d. Bore diameter t. Tip thickness
Table 3. Thread Mount Thermowells (Parallel Thread)
Code T, threaded mounting
Code
Process connection “P”
DA M20 1.5 1.18 (30) 0.67 (17) 0.67 (17) 0.5 (12.7)
DB M24 1.5 1.18 (30) 0.75 (19) 0.75 (19) 0.5 (12.7)
DC M27 2 1.26 or 1.42 (32 or 36) 0.75 (19) 0.75 (19) 0.5 (12.7)
DD M33 2 1.61 (41) 0.85 (21.5) 1.04 (26.5) 0.71 (18)
DE
DF
DG 1-in. BSPF (G1) 1.61 (41) 0.85 (21.5) 1.04 (26.5) 0.71 (18)
style
1
/2-in. BSPF (G1/2) 1.06 (27) 0.67 (17) 0.67 (17) 0.5 (12.7)
3
/4-in. BSPF (G3/4) 1.26 (32) 0.75 (19) 0.75 (19) 0.5 (12.7)
Hex size “F”
(1)
Root diameter
stepped stem
Root diameter
tapered stem
Tip diameter tapered
stem and straight
stem
Thread
specification
Thread per BS3643
Thread per ISO 228/1
(BS 2779)
1. Dimensions are in inches (millimeters).
Note
Hex size will be different depending on units selected (english and metric). Wrench flats are used on exotic materials instead of hex flats. For hex flats on exotic materials, select option R37. Additional root and tip diameters available.
1. Total length = U+ H.
Emerson.com/Rosemount
17
Rosemount 114C

Rosemount 114C Flanged Thermowells

June 2019
18
Emerson.com/Rosemount
June 2019
Model
Instrument
connection threads
Head
length (H)
Thermowell
material
Stem
style
Process
connection
Mounting
style
Immersion
length (U)
Units
114C X XXXXXXXXXXXXXX
16151413121198765432110 191817
(5) Units
English (E)
Metric (M)
(6-9) Immersion length (U)
XXXX
XXXX
(10) Mounting style
(11-12) Process connections
AA
1-in. Class 150
AB AC
1½-in. Class 150
2-in. Class 150
(13) Stem style
1
Straight stem
2 3
Tapered stem
Stepped stem
(14-15) Thermowell material
SC
316/316L SST
SF
CS
304/304L SST
Carbon steel
(16-18) Head length (H)
XXX
XXX
(19) Instrument connection
A
½-14 NPT
B
½-14 NPSM
Full penetration weld
F P
Partial penetration weld
Options
XX, XXX, XX
Common options
External pressure test
Q5
R21
Q35
Q8
NACE certification Wake frequency
calculation
Material certification
Q73
Dye penetration test
AH
AJ
1-in. Class 300
1½-in. Class 300
AK
2-in. Class 300
0.5in to 42in (E) Example: 0.5in=0005, 42in=0420
2.25in to 11.25in (E) Example: 2.25in=022, 10in=100
G
Forged, no welds
25mm to 1165mm (M) Example: 25mm=0025, 1165mm=1165
40mm to 225mm (M) Example: 40mm=040, 225mm=225
D M18 x 1.5p
E
M20 x 1.5p
F
M24 x 1.5p
U
H
A
B
Rosemount 114C

Flanged thermowell overview

All Rosemount flanged thermowells are manufactured in accordance with ANSI B16.5. The flange to stem weld is in accordance to ASME Section IX. There is also full traceability with material certifications available on request. Rosemount flanged thermowells are available in two manufacturing configurations: full and partial penetration welds.
Full penetration weld (F) Partial penetration weld (P) Forged, no welds (G)
Stronger weld
joint per ASME PTC 19.3 TW
Used for heavy
duty applications
Emerson recommended option
Figure 8. Standard Offering–Flanged
Adequate for
most process applications
Weld withstands
same pressure and temperature rating as flange
Lower cost than full penetration weld
Highest fatigue
resistance per ASME PTC 19.3 TW
Eliminates weld
qualifications and failures
Used in extreme process applications
The common options shown in Figure 8 represent a partial offering; reference the Rosemount 114C Flanged Ordering Information for a full list of available options.
Figure 9. Flanged Thermowell Components
A. Instrument connection B. Process connection
Note
Wetted surface includes flange face and immersion length (U).
Emerson.com/Rosemount
H. Head length U. Immersion length
19
Rosemount 114C
June 2019
Use the form below to record your model code:
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Instrument connection
Options
114C
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 X X X X X
20
Emerson.com/Rosemount
June 2019
U

Flanged ordering information

Figure 10. Model Number Ordering Example
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Rosemount 114C
Instrument connection
Options
114C E 0150 F A C 1 S C 0 5 0 A
1234 5 6789 10 11 12 13 14 15 16 17 18 19 X X X X X
The numbers below the model number ordering example correlate to the character place numbers in the second column of the ordering table.
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
1-4
Place #
Model Details
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip
114C Barstock temperature thermowell
Dimension units
5
E English units (in.)
M Metric units (mm) 59
wall thickness of 0.25-in. (6.4 mm). Default ASME flange facing is raised face with spiral serrations. Default EN 1092-1 flange facing is raised face Type B1.
Specifies whether length units will be in inches (in) or millimeters (mm)
WR5,
Q76...
Ref.
page
N/A
Ref.
page
59
Place #
6-9
Place #
10
Immersion length (U)
xx.x-in., 1 to 100-in. in 1/4-in. increments (when ordered with dimension units code E)
xxxx
Example of a 6.25-in. length where the second decimal is dropped off: 0062
xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
xxxx
Example of a 25 mm length: 0025
Mounting style
P Flange, partial penetration weld
Weld refers to welding of the flange to thermowell stem
F Flange, full penetration weld N/A
G Flange, forged Single piece forging, no welds N/A
Ref.
page
59
59
Ref.
page
N/A
Emerson.com/Rosemount
21
Rosemount 114C
June 2019
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
11-12
Process connection Details
Ref.
page
Partial weld (P) Full penetration weld (F) Forged, no welds (G)
AA 1-in. Class 150 1-in. Class 150 1-in. Class 150 N/A
AB 11/2-in. Class 150 11/2-in. Class 150 11/2-in. Class 150 N/A
AC 2-in. Class 150 2-in. Class 150 2-in. Class 150 N/A
AD 3-in. Class 150 3-in. Class 150 3-in. Class 150 N/A
AE 4-in. Class 150 4-in. Class 150 4-in. Class 150 N/A
AF 6-in. Class 150 6-in. Class 150 6-in. Class 150 N/A
3
AG
/4-in. Class 300
AH 1-in. Class 300 1-in. Class 300 1-in. Class 300 N/A
AJ 11/2-in. Class 300 11/2-in. Class 300 11/2-in. Class 300 N/A
AK 2-in. Class 300 2-in. Class 300 2-in. Class 300 N/A
3
/4-in. Class 300
3
/4-in. Class 300 N/A
AL 1-in. Class 400/600 1-in. Class 400/600 1-in. Class 400/600 N/A
AM 11/2-in. Class 400/600 11/2-in. Class 400/600 11/2-in. Class 400/600 N/A
AN 2-in. Class 400/600 2-in. Class 400/600 2-in. Class 400/600 N/A
AP N/A 1-in. Class 900/1500 1-in. Class 900/1500 N/A
AQ N/A 11/2-in. Class 900/1500 11/2-in. Class 900/1500 N/A
AR N/A 2-in. Class 900/1500 2-in. Class 900/1500 N/A
AT N /A 11/2-in. Class 2500 11/2-in. Class 2500 N/A
AU N/A 2-in. Class 2500 2-in. Class 2500 N/A
AV 3-in. Class 300 3-in. Class 300 3-in. Class 300 N/A
FA DN 20/PN 2.5/6 DN 20/PN 2.5/6 N/A N/A
FE DN 20/PN 10/16/25/40 DN 20/PN 10/16/25/40 N/A N/A
FG DN 20/PN 63/100 DN 20/PN 63/100 N/A
N/A
GA DN 25/PN 2.5/6 DN 25/PN 2.5/6 N/A N/A
GE DN 25/PN 10/16/25/40 DN 25/PN 10/16/25/40 N/A N/A
GG DN 25 PN 63/100 DN 25/PN 63/100 N/A N/A
JA DN 40/PN 2.5/6 DN 40/PN 2.5/6 N/A N/A
JE DN 40/PN 10/16/25/40 DN 40/PN 10/16/25/40 N/A
N/A
JG DN 40/PN 63/100 DN 40/PN 63/100 N/A N/A
KA DN 50/PN 2.5/6 DN 50/PN 2.5/6 N/A N/A
KC DN 50/PN 10/16 DN 50/PN 10/16 N/A N/A
KE DN 50/PN 25/40 DN 50/PN 25/40 N/A N/A
KF DN 50/PN 63 DN 50/PN 63 N/A N/A
22
Emerson.com/Rosemount
June 2019
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
11-12
Process connection Details
Partial weld (P) Full penetration weld (F) Forged, no welds (G)
KG DN 50/PN 100 DN 50/PN 100 N/A N/A
LA DN 65/PN 2.5/6 DN 65/PN 2.5/6 N/A N/A
LC DN 65/PN 10/16 DN 65/PN 10/16 N/A N/A
LE DN 65/PN 24/40 DN 65/PN 24/40 N/A N/A
LF DN 65/PN 63 DN 65/PN 63 N/A N/A
LG DN 65/PN 100 DN 65/PN 100 N/A N/A
MA DN 80/PN 2.5/6 DN 80/PN 2.5/6 N/A N/A
MC DN 80/PN 10/16 DN 80/PN 10/16 N/A N/A
ME DN 80/PN 25/40 DN 80/PN 25/40 N/A N/A
MF DN 80/PN 63 DN 80/PN 63 N/A N/A
Rosemount 114C
Ref.
page
MG DN 80/PN 100 DN 80/PN 100 N/A N/A
NA DN 100/PN 2.5/6 DN 100/PN 2.5/6 N/A N/A
NC DN 100/PN 10/16 DN 100/PN 10/16 N/A N/A
NE DN 100/PN 25/40 DN 100/PN 25/40 N/A N/A
NF DN 100/PN 63 DN 100/PN 63 N/A N/A
NG DN 100/PN 100 DN 100/PN 100 N/A N/A
Place #
13
Stem style Details Image
1 Straight
2 Ta p er e d
Minimum immersion length = 1-in. (25 mm)
Minimum immersion length = 1-in. (25 mm)
Ref.
page
60
60
3 Stepped
Emerson.com/Rosemount
Minimum immersion length = 3-in. (75 mm)
60
23
Rosemount 114C
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
14-15
Thermowell material Details
SC 316/316L dual rated 61
SD 316/316L dual rated (NORSOK)
SF 304/304L dual rated 61
CS Carbon steel (A-105) 61
SG 316Ti SST 61
SH 316/316L SST with tantalum sheath
SJ 316/316L SST with PFA coating 61
SK 304/304L SST with PTFE coating 61
SL 310 SST 61
SM 321 SST 61
Must order the Q8 Material Certificate to get NORSOK documentation
Only available as a straight stem profile with a 0.75 diameter thus requires option A075 for English units
June 2019
Ref.
page
62
62
SN 321H SST 61
SR 904L SST 61
SP 347 SST 61
AB Alloy B3 61
AC Alloy C-276 61
AD Alloy C-4 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 61
AE Alloy C-22 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 61
AF Alloy C-22 (with 316/316L SST flange) Not available with G (Fully forged) mounting style 61
AG Alloy 20 61
AH Alloy 400 61
AJ Alloy 400 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 61
AK Alloy 600 61
AL Alloy 600 (with 304/304L SST flange) Not available with G (Fully forge) mounting style 61
AM Alloy 601 61
AN Alloy 625 61
AP Alloy 800 61
AQ Alloy 800H/HT 61
AR Alloy 825 61
AU Alloy C-20 61
AS Alloy F44 Mo6 61
CA Chrome-Moly Grade B-11/F-11 Class II 61
CB Chrome-Moly Grade B-22/ F-22 Class III 61
24
Emerson.com/Rosemount
June 2019
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
CC Chrome-Moly Grade F-91 61
NK Nickel 200 61
TT Titanium Grade 2 61
DS Super duplex SST Grade F-53 61
DT Super duplex – NORSOK
DU Duplex 2205 Grade F51 61
DV Duplex 2205 – NORSOK
Place #s
16-18
Head length (H)
xx.x-in., 2.25 to 11.25-in. in 1/4-in. increments (when ordered with dimension units code E)
xxx
Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 2.25-in. for flanges under Class 900)
xxx mm, 45 to 225 mm in 5 mm increments (when ordered with dimension units code M)
xxx
Example of a 50 mm length: 050 (default head length = 60 mm for flanges under Class 900)
Must order the Q8 Material Certificate to get NORSOK documentation
Must order the Q8 Material Certificate to get NORSOK documentation
Rosemount 114C
62
62
Ref.
page
63
63
Place #
19
Instrument connection Details Image
1
A
B
C
D M18 1.5p 64
E M20 1.5p 64
F M24 1.5p 64
G G 1/2-in. (BSPF) 64
H G 3/4-in. (BSPF) 64
J M27 2p 64
K M14 1.5p 64
/2–14 NPT
1
/2–14 NPSM 64
3
/4–14 NPT 64
Female threads
Options (include with selected model number)
Sensor/thermowell assemble to options Details
Hand tight assembly of sensor and
XT
thermowell
Process-ready assembly of sensor and
XW
thermowell
Ensures sensor is threaded into thermowell but only hand tightened 65
Ensures sensor is threaded into thermowell and torqued for process-ready installation
Ref.
page
64
Ref.
page
65
Emerson.com/Rosemount
25
Rosemount 114C
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Extended product warranty
WR3 3-year limited warranty
WR5 5-year limited warranty 65
This warranty option extends manufacturer’s warranty to three or five years for manufacturer related defects
June 2019
Ref.
page
65
Thermowell calculation Details
Set of calculations to ensure thermowells are safe in certain process conditions
R21 Thermowell calculation
Note: If your chosen mounting style is flange with full penetration weld (F) then you must choose dye penetration option (Q73) to meet the ASME PTC 19.3 TW standard requirements.
NACE certification
Q35 NACE certification Meets MR0175/ISO 15156 and MR0103 requirements 66
PMI testing
Q76 PMI testing Verifies chemical composition of material 66
Material certification
Q8 Material certification
Certificate for material conformance and traceability in accordance with EN 10204 type 3.1
Material tests
M01 Low temperature Charpy Test
M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 67
Measures the low temperature ductility of the material. This option drives a different weld documentation.
Ref.
page
65
Ref.
page
Ref.
page
Ref.
page
67
Ref.
page
67
Surface finish
Q16 Certification Certificate showing measured surface finish values 68
R14 Finish < Ra 0.3 μm (12 μin) Improves surface roughness of thermowell 68
Electropolish
R20 Electropolish Improve smoothness and surface quality 68
Hydrostatic external pressure test
Q5 Standard external pressure test
Q9 Extended external pressure test Same as standard external pressure test but tested for twice as long 69
Verifies structural quality and checks for leaks at thermowell process connection and stem
Hydrostatic internal pressure test
Q85 Standard internal pressure test Verifies internal structural integrity of thermowell 69
Q86 Extended internal pressure test Same as standard internal pressure test but tested for twice as long 70