Rosemount 114C Specifications

Page 1
Rosemount™ 114C Thermowells
Product Data Sheet
June 2019
00813-0200-4952, Rev EB
Wide variety of industry standard process connections including flanged, threaded, welded, and Van
Stone.
exotic materials such as duplex and alloy C-276.
Additional thermowell options and certificates available.
Page 2
Rosemount 114C
Contents
June 2019
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Rosemount 114C Threaded Thermowells . . . . . . . . . . . . 6
Threaded thermowell overview . . . . . . . . . . . . . . . . . . . 7
Threaded ordering information . . . . . . . . . . . . . . . . . . . 7
Threaded thermowell drawings . . . . . . . . . . . . . . . . . . 16
Rosemount 114C Flanged Thermowells . . . . . . . . . . . . 18
Flanged thermowell overview . . . . . . . . . . . . . . . . . . . 19
Flanged ordering information . . . . . . . . . . . . . . . . . . . 21
Flanged thermowell drawings . . . . . . . . . . . . . . . . . . . 30
Rosemount 114C Van Stone Thermowells . . . . . . . . . . .33
Van Stone thermowell overview . . . . . . . . . . . . . . . . .34
Van Stone ordering information . . . . . . . . . . . . . . . . .36
Van Stone thermowell drawings . . . . . . . . . . . . . . . . .44
Rosemount 114C Welded Thermowells . . . . . . . . . . . . .46
Welded thermowell overview . . . . . . . . . . . . . . . . . . .47
Welded ordering information . . . . . . . . . . . . . . . . . . . 49
Weld-in Type 4 thermowells according to DIN 43772 .55
Welded thermowell drawings . . . . . . . . . . . . . . . . . . .57
Ordering information detail . . . . . . . . . . . . . . . . . . . . . . .59
2
Emerson.com/Rosemount
Page 3
June 2019
Rosemount 114C

Rosemount 114C Thermowell

Product overview

Temperature sensors are rarely inserted directly into an industrial process. They are installed into a thermowell to isolate them from the potentially damaging process conditions of flow-induced stresses, high pressure, and corrosive chemical effects. Thermowells are closed-end metal tubes or barstock installed into the process vessel or piping and become an integral pressure-tight part of the process vessel or pipe. They permit the sensor to be quickly and easily removed from the process for calibration or replacement without requiring a process shutdown and possible drainage of the pipe or vessel.
The Rosemount 114C Thermowell is made from solid barstock to ensure strength and integrity. The Rosemount 114C was designed to accommodate a host of industry standard configurations, but has the flexibility to adapt to special configurations for different types of applications.

Flexible design modifiers accommodate many process requirements

Different sizes of root (A), tip (B), and bore (d) diameters
Different tip (t) thickness as required
Numerous combinations for various industrial applications
Meet ASME PTC 19.3 TW standard with flexible design
A
B
t
d

Thermowell calculations ensure thermowell design is compatible with process conditions

Thermowells inserted into any process are subjected to forces
from the fluid flow.
ASME released design standard PTC 19.3 TW that defines a
series of qualitative calculations to determine design suitability to withstand process conditions.
Calculations are based on process conditions, process fluid,
installation method, thermowell geometry and material.
The thermowell calculation tool from Emerson is designed to
meet the ASME standard.
The free online software version can be used for preliminary
calculations. Click here to access the tool.
Formal calculations by our expert team of engineers are
available prior to order placement to ensure design is acceptable.
Recommendations are also made if thermowell design is found
to be unacceptable for the application.
Order Thermowell Calculation option (R21) to receive a formal
report with product shipment.
Figure 1. Thermowell Calculation Report (R21)
Emerson.com/Rosemount
3
Page 4
Rosemount 114C
June 2019

Wide range of thermowell options and certificates for any application

Options for special testing requirements, such as External Hydrostatic Pressure Test (Q5) and Dye Penetration Test (Q73)
Options to ensure material traceability or compatibility, including Positive Material Identification or PMI (Q76), Material
®
Certification (Q8), Thermowell X-ray/Radiograph (Q81), and NACE
Options for special processing requirements such as Electropolishing (R20)
Approval (Q35)

Experience global consistency and local support from numerous worldwide Emerson manufacturing sites

World-class manufacturing provides globally consistent product
from every factory and the capacity to fulfill the needs of any project, large or small.
Experienced Instrumentation Consultants help select the right
product for any temperature application and offer advice on best installation practices.
An extensive global network of Emerson service and support
personnel can be on-site when and where they are needed.

Explore the benefits of a Complete Point Solution™ from Emerson

An “Assemble Sensor to Specific Transmitter” and “Assemble Sensor to Specific Thermowell” option enables Emerson to provide a
Complete Point Solution for measuring temperature, delivering an installation-ready transmitter, sensor, and thermowell assembly.
Emerson has a complete portfolio of Single Point and Multi-Input Temperature Measurement solutions, allowing effective
measurement and process control with reliable Rosemount products.
4
Emerson.com/Rosemount
Page 5
June 2019
UH
L
Rosemount 114C

Selection guide

Ensure sensor fits thermowell

Rosemount 114C Head length (H) + Immersion length (U) = Rosemount 214C Sensor insertion length (L).

Basic selection guide

Selecting the proper thermowell for an application is an important activity as it impacts plant safety and measurement efficiency. Thermowells are considered a wetted part; they physically become part of the pressure retaining system.
The four major factors to consider when selecting a thermowell for an application are described below:
Thermowell length
There is no standard formula to determine thermowell immersion length. However, there are a few common practices that the process industry follows along with good engineering judgment. Ideally the thermowell tip should be located near the centerline in turbulent flow conditions because this represents the most accurate process temperature.
To ensure optimal performance, a general guideline for immersion length into a pipe is as follows:
10 the thermowell root diameter for air or gas
5 the thermowell root diameter for liquids
Another guideline is at least one-third the way into the pipe for any measurement. The American Petroleum Institute (API) has a specific recommendation of using an immersion length of the sensing element plus 50 mm (2-in.).
Mounting configuration
Consider how the thermowell is mounted on the pipe or tank. The process designer typically specifies what mating connection will be used and the thermowell selected should match that connection. Temperature, pressure, and material are usually taken into consideration to ensure the process connection will be adequate for the application. Welded, threaded, flanged, and Van Stone are standard mounting configuration options.
Thermowell stem profile
Factors to be considered when selecting a stem style include the process pressure, required response speed of the measurement, drag force of the fluid flow on the well, and the wake frequency. The stem or shank is the part of a thermowell inserted into the process piping or vessel. Straight, stepped and tapered stem styles are available. Each profile has its advantages depending on the need and situation.
Thermowell material
Rosemount Thermowells are supplied in most materials required for industrial applications. Standard materials are 316/316L Stainless Steel, 304/304L Stainless Steel, and A105 Carbon Steel. For corrosive environments, special materials such as Alloy C-276 and Alloy 600 are also available. See the ordering table for a complete listing of standard materials. Contact your local Emerson representative for additional material availability.
Emerson.com/Rosemount
5
Page 6
Rosemount 114C

Rosemount 114C Threaded Thermowells

June 2019
6
Emerson.com/Rosemount
Page 7
June 2019
Model
Instrument
connection threads
Head
length (H)
Thermowell
material
Stem
style
Process
connection
Mounting
style
Immersion
length (U)
Units
114C X XXXXXXXXXTXXXX
16151413121198765432110 191817
(5) Units
English (E)
Metric (M)
(6-9) Immersion length (U)
25 to 1165 mm (M) Example: 25 mm = 0025, 1165 mm =1165
1- to 42-in. (E) Example: 2-in. = 0020, 42-in. =0420
XXXX
XXXX
(10) Mounting style
Threaded (T)
(11-12) Process connections
AA ½-14 NPT
AB AC
¾-14 NPT
1-11.5 NPT
(13) Stem style
1
Straight stem
2 3
Tapered stem
Stepped stem
(14-15) Thermowell material
SC 316/316L SST
SF CS
304/304L SST
Carbon steel
(16-18) Head length (H)
40 to 225mm (M) Example: 40 mm = 040, 225 mm =225
1.75- to 11.25-in. (E) Example: 1.75.in = 017, 10-in. = 100
XXX
XXX
(19) Instrument connection
A
½-14 NPT
B
½-14 NPSM
Options
XX, XXX, XX
Common options
External pressure test
Q5
R21
Q35
Q8
NACE certification Thermowell
calculation
Material certification
DA M20 x 1.5p
DB DE
M24 x 1.5p
½-in. BSPF (G½)
D
M18 x 1.5p
E
M20 x 1.5p
F
M24 x 1.5p
Rosemount 114C

Threaded thermowell overview

Threaded thermowells are threaded into a process pipe or tank, allowing for easy installation and removal when necessary. While this is a common mounting method, it has the lowest pressure rating of all mounting configuration options.
Figure 2. Standard Offering–Threaded
The common options shown in Figure 2 represent a partial offering; reference the Rosemount 114C Threaded Ordering Information for a full list of available options.
Figure 3. Threaded Thermowell Components
A
A. Instrument connection B. Process connection
Note
Wetted surface includes engaged threads and immersion length (U).
Emerson.com/Rosemount
H
Tapered threads Parallel threads
B
U
A
H. Head length U. Immersion length
HU
B
7
Page 8
Rosemount 114C
June 2019
Use the form below to record your model code:
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Instrument connection
Options
114C T
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 X X X X X
8
Emerson.com/Rosemount
Page 9
June 2019
U

Threaded ordering information

Figure 4. Model Number Ordering Example
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Rosemount 114C
Instrument connection
Options
114C E 0060 T A A 1 S C 0 5 0 A
1234 5 6789 10 11 12 13 14 15 16 17 18 19 X X X X X
WR5,
Q76...
The numbers below the model number ordering example correlate to the character place numbers in the second column of the ordering table.
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
1-4
Place #
Model Details
Barstock temperature
114C
thermowell
Dimension units
5
E English units (in.)
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip wall thickness of 0.25-in. (6.4 mm)
Ref.
page
N/A
Ref.
page
59
Specifies whether length units will be in inches (in.) or millimeters (mm)
M Metric units (mm) 59
Tapered threads Parallel threads
Place #s
6-9
Immersion length (U)
U
Ref.
page
xxxx
Example of a 6.25-in. length where the second decimal is dropped off: 0062
xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
xxx.x-in., 1.00 to 100-in. in 1/4-in. increments (when ordered with dimension units code E)
xxxx
Example of a 50 mm length: 0050
Place #
10
Place #s
11-12
Emerson.com/Rosemount
Mounting style
T Threaded N/A
Process connection
1
AA
AB
AC 1–11.5 NPT Taper ed threads N/A
AD 11/2–11.5 NPT Taper ed threads N/A
AE
/2–14 NPT Taper ed threads N/A
3
/4–14 NPT Taper ed threads N/A
1
/2-in. BSPT Tap ered t hreads N/ A
59
59
Ref.
page
Ref.
page
9
Page 10
Rosemount 114C
June 2019
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
3
AF
/4-in. BSPT Tap ered t hreads N/ A
AG 1-in. BSPT Taper ed threads N/A
DA M20 1.5p Parallel threads N/A
DB M24 1.5p Parallel threads N/A
DC M27 2p Parallel threads N/A
DD M33 2p Parallel threads N/A
1
DE
DF
/2-in. BSPF (G1/2) Parallel threads N/A
3
/4-in. BSPF (G3/4) Parallel threads N/A
DG 1-in. BSPF (G1) Parallel threads N/A
Place #
13
Stem style Details Image
Minimum immersion length
1 Straight
1-in. (25 mm) - Tapered threads
1.75-in. (45 mm) - Parallel threads
Minimum immersion length
2 Tap e re d
1-in. (25 mm) - Tapered threads
1.75-in. (45 mm) - Parallel threads
Minimum immersion length
3 Stepped
3-in. (75 mm) - Tapered threads
3.75-in. (95 mm) - Parallel threads
Place #s
14-15
Thermowell material Details
SC 316/316L dual rated 61
SD 316/316L dual rated (NORSOK) Must order the Q8 Material Certificate to get NORSOK documentation 62
SF 304/304L dual rated 61
CS Carbon steel (A-105) 61
SG 316Ti SST 61
SL 310 SST 61
SM 321 SST 61
Ref.
page
60
60
60
Ref.
page
SN 321H SST 61
SR 904L SST 61
SP 347 SST 61
AB Alloy B3 61
AC Alloy C-276 61
AG Alloy 20 62
AH Alloy 400 61
AK Alloy 600 61
10
Emerson.com/Rosemount
Page 11
June 2019
H
Rosemount 114C
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
AM Alloy 601 61
AN Alloy 625 61
AP Alloy 800 61
AQ Alloy 800H/HT 61
AR Alloy 825 61
AU Alloy C-202 61
AS Alloy F44 Mo6 61
MO Molybdenum 61
Chrome-Moly Grade B-11/F-11
CA
Class II
Chrome-Moly Grade B-22/ F-22
CB
Class III
61
61
CC Chrome-Moly Grade F-91 61
NK Nickel 200 61
TT Titanium Grade 2 61
DS Super duplex SST Grade F-53 61
Super duplex SST Grade F-53 –
DT
NORSOK
Must order the Q8 Material Certificate to get NORSOK documentation 62
DU Duplex 2205 Grade F51 61
Duplex 2205 Grade F51 –
DV
NORSOK
Must order the Q8 Material Certificate to get NORSOK documentation 62
Tapered threads Parallel threads
Place #
16-18
xxx
xxx
Head length (H)
xx.x-in., 1.75 to 11.25-in. in 1/4-in. increments (when ordered with dimension units code E)
Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 1.75-in.)
xxx mm, 40 to 225 mm in 5 mm increments (when ordered with dimension units code M)
Example of a 50 mm length: 050 (default head length = 45 mm)
H
Ref.
page
63
63
Emerson.com/Rosemount
11
Page 12
Rosemount 114C
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
June 2019
Place #
19
Instrument connection Details Image
1
A
B
C
D M18 1.5p 64
E M20 1.5p 64
F M24 1.5p 64
G G 1/2-in. (BSPF) 64
H G 3/4-in. (BSPF) 64
J M27 2p 64
K M14 1.5p 64
/2–14 NPT
1
/2–14 NPSM 64
3
/4–14 NPT 64
Female threads
Options (include with selected model number)
Sensor/thermowell assemble to options
Hand tight assembly of sensor
XT
and thermowell
Process-ready assembly of
XW
sensor and thermowell
Details
Ensures sensor is threaded into thermowell but only hand tightened 65
Ensures sensor is threaded into thermowell and torqued for process-ready installation
Ref.
page
64
Ref.
page
65
Extended product warranty
WR3 3-year limited warranty
WR5 5-year limited warranty 65
This warranty option extends manufacturer’s warranty to three or five years for manufacturer related defects
Thermowell calculation
R21 Thermowell calculation Set of calculations to ensure thermowells are safe in certain process conditions 65
NACE certification
Q35 NACE certification Meets MR0175/ISO 15156 and MR0103 requirements 66
PMI testing
Q76 PMI testing Verifies chemical composition of material 66
Material certification
Q8 Material certification
Certificate for material conformance and traceability in accordance with EN 10204 type 3.1
Ref.
page
65
Ref.
page
Ref.
page
Ref.
page
Ref.
page
67
12
Emerson.com/Rosemount
Page 13
June 2019
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Rosemount 114C
Material tests
M01 Low temperature Charpy Test Measures the low temperature ductility of the material 67
M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 67
Surface finish Details
Q16 Certification Certificate showing measured surface finish values 68
R14 Finish < Ra 0.3 μm (12 μin) Improves surface roughness of thermowell 68
Electropolish
R20 Electropolish Improve smoothness and surface quality 68
Hydrostatic external pressure test
Q5 Standard external pressure test
Q9 Extended external pressure test Same as standard external pressure test but tested twice as long 69
Verifies structural quality and checks for leaks at thermowell process connection and stem
Hydrostatic internal pressure test
Ref.
page
Ref.
page
Ref.
page
Ref.
page
68
Ref.
page
Q85 Standard internal pressure test Verify internal structural integrity of thermowell 69
Q86 Extended internal pressure test Same as standard internal pressure test but tested twice as long 70
Canadian Registration Number
Q17 Canadian Registration Number Canadian approvals for all provinces (Approved materials in reference section) 70
Dye penetration test
Q73 Dye penetration test Checks quality of material 70
Wall thickness test
Q83 Ultrasonic test Checks the bore concentricity of the thermowell 71
Q84 Radiography (X-ray) test Checks the bore concentricity of the thermowell 72
Special cleaning
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 71
Thermowell markings
Ref.
page
Ref.
page
Ref.
page
Ref.
page
Ref.
page
R40 Test markings on thermowell
Emerson.com/Rosemount
External marking of the thermowell for specific tests (see reference page for list of tests)
71
13
Page 14
Rosemount 114C
A
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
June 2019
Plug and chain
R06 Stainless steel Protects thermowell threads when sensor is not installed 73
R23 Brass Protects thermowell threads when sensor is not installed 73
Spherical tip
R60 Spherical tip Changes the flat tip to spherical 72
Vent hole
R11 Vent hole
Allows for the venting of a thermowell and for indication that thermowell structural integrity has been compromised
Thermowells with wrench flats
R37 Thermowells with wrench flats
Converts the two wrench flats to hex wrench flats; only applies to exotic materials
Root diameter (A)
Ref.
page
Ref.
page
Ref.
page
73
Ref.
page
79
Ref.
page
x.xx-in., 0.36 to 3.15-in. in 0.01-in. increments (when ordered with dimension units code E)
Axxx
Examples: Code A040 = 0.4-in., Code A315 = 3.15-in.
xx.xx mm, 10 to 80 mm in 0.5 mm increments (when ordered with dimension units code M)
Axxx
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm
Tip diameter (B)
x.xx-in., 0.36 to 1.83-in. in 0.01-in. increments (when ordered with dimension units code E)
Bxxx
Examples: Code B040 = 0.4-in., Code B180 = 1.80-in.
xx.xx mm, 10 to 46 mm in 0.5-mm. increments (when ordered with dimension units code M)
Bxxx
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm
B
Non-standard bore diameter (d) Details Image
D01 0.276-in./7.0 mm
d
D03 0.138-in./3.5 mm 82
D04 0.386- in./9.8 mm 82
D05 0.354-in./9.0 mm 82
D06 0.433-in./11.0 mm 82
Default = 0.26-in. (6.6 mm)
80
80
Ref.
page
81
81
Ref.
page
82
14
Emerson.com/Rosemount
Page 15
June 2019
t
A
B
C
D
C
Rosemount 114C
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Non-standard tip thickness (t)
Ref.
page
T01 0.197-in./5.0 mm
Default = 0.25-in. (6.4 mm)
T02 0.236-in./6.0 mm 82
Threaded installation
Threaded thermowells are screwed into the process using a threaded fitting or directly into a tapped pipe if there is sufficient wall thickness. Tapered threads will deform to each other to create a seal. Thread sealant and appropriate torque should be applied to reduce risk of leaks.
Figure 5. Installation Components
82
A. Thermowell B. Threaded fitting C. Weld D. Process
Emerson.com/Rosemount
15
Page 16
Rosemount 114C
.75 (19)
2.5 (63.5)
N
P
H
U
d
t
A
B
A
B
C
E
A

Threaded thermowell drawings

June 2019
Figure 6. Thread Mount Thermowell Drawings (Tapered Thread)
Straight Tapered Stepped
A. Root diameter B. Tip diameter C. Total length (U + H) E. Wrench allowance F. Thread allowance H. Head length
(1)
N. Instrument connection P. Process connection U. Immersion length d. Bore diameter t. Tip thickness
Table 2. Thread Mount Thermowells (Tapered Thread)
Code T, threaded
mounting style
Code
Process
connection “P”
AA
AB
AC 1–11.5 NPT 1.34 (34) 1
AD 1
AE
AF
AG 1-in. BSPT 1.34 (34) 1
1. Dimensions are in inches (millimeters).
1. Total length = U+ H.
16
1
/2–14 NPT 1.18 (30) 11/8 (28.6) 0.67 (17) 0.67 (17) 0.50 (12.7) 0.669 (17)
3
/4–14 NPT 1.18 (30) 11/8 (28.6) 0.75 (19) 0.89 (22.5) 0.63 (16) 0.71 (18)
1
/2–11.5 NPT 1.89 (48) 13/4 (44.5) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18)
1
/2-in. BSPT 1.18 (30) 11/8 (28.6) 0.67 (17) 0.67 (17) 0.50 (12.7) 0.669 (17)
3
/4-in. BSPT 1.18 (30) 11/8 (28.6) 0.75 (19) 0.89 (22.5) 0.63 (16) 0.71 (18)
Wrench flat size “G”
Metric units
(code M)
English units
(code E)
1
/4 (31.8) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18)
1
/4 (31.8) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18)
(1)
Root diameter
stepped stem
Root diameter
tapered stem
Tip diameter
tapered stem
Root diameter
straight stem
Thread
specification
NPT per SAE -AS
71051
(reference PS-71)
THD per ISO 7/1 (BS
21)
Emerson.com/Rosemount
Page 17
June 2019
F
2.50 [63,5]
STEP LENGTH
N
P
H
U
d
t
B
B
A
A
C
A
Rosemount 114C
Figure 7. Thread Mount Thermowell Drawings (Parallel Thread)
Straight Tapered Stepped
A. Root diameter B. Tip diameter C. Total length (U + H) F. Hex size H. Head length
(1)
N. Instrument connection P. Process connection U. Immersion length d. Bore diameter t. Tip thickness
Table 3. Thread Mount Thermowells (Parallel Thread)
Code T, threaded mounting
Code
Process connection “P”
DA M20 1.5 1.18 (30) 0.67 (17) 0.67 (17) 0.5 (12.7)
DB M24 1.5 1.18 (30) 0.75 (19) 0.75 (19) 0.5 (12.7)
DC M27 2 1.26 or 1.42 (32 or 36) 0.75 (19) 0.75 (19) 0.5 (12.7)
DD M33 2 1.61 (41) 0.85 (21.5) 1.04 (26.5) 0.71 (18)
DE
DF
DG 1-in. BSPF (G1) 1.61 (41) 0.85 (21.5) 1.04 (26.5) 0.71 (18)
style
1
/2-in. BSPF (G1/2) 1.06 (27) 0.67 (17) 0.67 (17) 0.5 (12.7)
3
/4-in. BSPF (G3/4) 1.26 (32) 0.75 (19) 0.75 (19) 0.5 (12.7)
Hex size “F”
(1)
Root diameter
stepped stem
Root diameter
tapered stem
Tip diameter tapered
stem and straight
stem
Thread
specification
Thread per BS3643
Thread per ISO 228/1
(BS 2779)
1. Dimensions are in inches (millimeters).
Note
Hex size will be different depending on units selected (english and metric). Wrench flats are used on exotic materials instead of hex flats. For hex flats on exotic materials, select option R37. Additional root and tip diameters available.
1. Total length = U+ H.
Emerson.com/Rosemount
17
Page 18
Rosemount 114C

Rosemount 114C Flanged Thermowells

June 2019
18
Emerson.com/Rosemount
Page 19
June 2019
Model
Instrument
connection threads
Head
length (H)
Thermowell
material
Stem
style
Process
connection
Mounting
style
Immersion
length (U)
Units
114C X XXXXXXXXXXXXXX
16151413121198765432110 191817
(5) Units
English (E)
Metric (M)
(6-9) Immersion length (U)
XXXX
XXXX
(10) Mounting style
(11-12) Process connections
AA
1-in. Class 150
AB AC
1½-in. Class 150
2-in. Class 150
(13) Stem style
1
Straight stem
2 3
Tapered stem
Stepped stem
(14-15) Thermowell material
SC
316/316L SST
SF
CS
304/304L SST
Carbon steel
(16-18) Head length (H)
XXX
XXX
(19) Instrument connection
A
½-14 NPT
B
½-14 NPSM
Full penetration weld
F P
Partial penetration weld
Options
XX, XXX, XX
Common options
External pressure test
Q5
R21
Q35
Q8
NACE certification Wake frequency
calculation
Material certification
Q73
Dye penetration test
AH
AJ
1-in. Class 300
1½-in. Class 300
AK
2-in. Class 300
0.5in to 42in (E) Example: 0.5in=0005, 42in=0420
2.25in to 11.25in (E) Example: 2.25in=022, 10in=100
G
Forged, no welds
25mm to 1165mm (M) Example: 25mm=0025, 1165mm=1165
40mm to 225mm (M) Example: 40mm=040, 225mm=225
D M18 x 1.5p
E
M20 x 1.5p
F
M24 x 1.5p
U
H
A
B
Rosemount 114C

Flanged thermowell overview

All Rosemount flanged thermowells are manufactured in accordance with ANSI B16.5. The flange to stem weld is in accordance to ASME Section IX. There is also full traceability with material certifications available on request. Rosemount flanged thermowells are available in two manufacturing configurations: full and partial penetration welds.
Full penetration weld (F) Partial penetration weld (P) Forged, no welds (G)
Stronger weld
joint per ASME PTC 19.3 TW
Used for heavy
duty applications
Emerson recommended option
Figure 8. Standard Offering–Flanged
Adequate for
most process applications
Weld withstands
same pressure and temperature rating as flange
Lower cost than full penetration weld
Highest fatigue
resistance per ASME PTC 19.3 TW
Eliminates weld
qualifications and failures
Used in extreme process applications
The common options shown in Figure 8 represent a partial offering; reference the Rosemount 114C Flanged Ordering Information for a full list of available options.
Figure 9. Flanged Thermowell Components
A. Instrument connection B. Process connection
Note
Wetted surface includes flange face and immersion length (U).
Emerson.com/Rosemount
H. Head length U. Immersion length
19
Page 20
Rosemount 114C
June 2019
Use the form below to record your model code:
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Instrument connection
Options
114C
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 X X X X X
20
Emerson.com/Rosemount
Page 21
June 2019
U

Flanged ordering information

Figure 10. Model Number Ordering Example
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Rosemount 114C
Instrument connection
Options
114C E 0150 F A C 1 S C 0 5 0 A
1234 5 6789 10 11 12 13 14 15 16 17 18 19 X X X X X
The numbers below the model number ordering example correlate to the character place numbers in the second column of the ordering table.
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
1-4
Place #
Model Details
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip
114C Barstock temperature thermowell
Dimension units
5
E English units (in.)
M Metric units (mm) 59
wall thickness of 0.25-in. (6.4 mm). Default ASME flange facing is raised face with spiral serrations. Default EN 1092-1 flange facing is raised face Type B1.
Specifies whether length units will be in inches (in) or millimeters (mm)
WR5,
Q76...
Ref.
page
N/A
Ref.
page
59
Place #
6-9
Place #
10
Immersion length (U)
xx.x-in., 1 to 100-in. in 1/4-in. increments (when ordered with dimension units code E)
xxxx
Example of a 6.25-in. length where the second decimal is dropped off: 0062
xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
xxxx
Example of a 25 mm length: 0025
Mounting style
P Flange, partial penetration weld
Weld refers to welding of the flange to thermowell stem
F Flange, full penetration weld N/A
G Flange, forged Single piece forging, no welds N/A
Ref.
page
59
59
Ref.
page
N/A
Emerson.com/Rosemount
21
Page 22
Rosemount 114C
June 2019
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
11-12
Process connection Details
Ref.
page
Partial weld (P) Full penetration weld (F) Forged, no welds (G)
AA 1-in. Class 150 1-in. Class 150 1-in. Class 150 N/A
AB 11/2-in. Class 150 11/2-in. Class 150 11/2-in. Class 150 N/A
AC 2-in. Class 150 2-in. Class 150 2-in. Class 150 N/A
AD 3-in. Class 150 3-in. Class 150 3-in. Class 150 N/A
AE 4-in. Class 150 4-in. Class 150 4-in. Class 150 N/A
AF 6-in. Class 150 6-in. Class 150 6-in. Class 150 N/A
3
AG
/4-in. Class 300
AH 1-in. Class 300 1-in. Class 300 1-in. Class 300 N/A
AJ 11/2-in. Class 300 11/2-in. Class 300 11/2-in. Class 300 N/A
AK 2-in. Class 300 2-in. Class 300 2-in. Class 300 N/A
3
/4-in. Class 300
3
/4-in. Class 300 N/A
AL 1-in. Class 400/600 1-in. Class 400/600 1-in. Class 400/600 N/A
AM 11/2-in. Class 400/600 11/2-in. Class 400/600 11/2-in. Class 400/600 N/A
AN 2-in. Class 400/600 2-in. Class 400/600 2-in. Class 400/600 N/A
AP N/A 1-in. Class 900/1500 1-in. Class 900/1500 N/A
AQ N/A 11/2-in. Class 900/1500 11/2-in. Class 900/1500 N/A
AR N/A 2-in. Class 900/1500 2-in. Class 900/1500 N/A
AT N /A 11/2-in. Class 2500 11/2-in. Class 2500 N/A
AU N/A 2-in. Class 2500 2-in. Class 2500 N/A
AV 3-in. Class 300 3-in. Class 300 3-in. Class 300 N/A
FA DN 20/PN 2.5/6 DN 20/PN 2.5/6 N/A N/A
FE DN 20/PN 10/16/25/40 DN 20/PN 10/16/25/40 N/A N/A
FG DN 20/PN 63/100 DN 20/PN 63/100 N/A
N/A
GA DN 25/PN 2.5/6 DN 25/PN 2.5/6 N/A N/A
GE DN 25/PN 10/16/25/40 DN 25/PN 10/16/25/40 N/A N/A
GG DN 25 PN 63/100 DN 25/PN 63/100 N/A N/A
JA DN 40/PN 2.5/6 DN 40/PN 2.5/6 N/A N/A
JE DN 40/PN 10/16/25/40 DN 40/PN 10/16/25/40 N/A
N/A
JG DN 40/PN 63/100 DN 40/PN 63/100 N/A N/A
KA DN 50/PN 2.5/6 DN 50/PN 2.5/6 N/A N/A
KC DN 50/PN 10/16 DN 50/PN 10/16 N/A N/A
KE DN 50/PN 25/40 DN 50/PN 25/40 N/A N/A
KF DN 50/PN 63 DN 50/PN 63 N/A N/A
22
Emerson.com/Rosemount
Page 23
June 2019
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
11-12
Process connection Details
Partial weld (P) Full penetration weld (F) Forged, no welds (G)
KG DN 50/PN 100 DN 50/PN 100 N/A N/A
LA DN 65/PN 2.5/6 DN 65/PN 2.5/6 N/A N/A
LC DN 65/PN 10/16 DN 65/PN 10/16 N/A N/A
LE DN 65/PN 24/40 DN 65/PN 24/40 N/A N/A
LF DN 65/PN 63 DN 65/PN 63 N/A N/A
LG DN 65/PN 100 DN 65/PN 100 N/A N/A
MA DN 80/PN 2.5/6 DN 80/PN 2.5/6 N/A N/A
MC DN 80/PN 10/16 DN 80/PN 10/16 N/A N/A
ME DN 80/PN 25/40 DN 80/PN 25/40 N/A N/A
MF DN 80/PN 63 DN 80/PN 63 N/A N/A
Rosemount 114C
Ref.
page
MG DN 80/PN 100 DN 80/PN 100 N/A N/A
NA DN 100/PN 2.5/6 DN 100/PN 2.5/6 N/A N/A
NC DN 100/PN 10/16 DN 100/PN 10/16 N/A N/A
NE DN 100/PN 25/40 DN 100/PN 25/40 N/A N/A
NF DN 100/PN 63 DN 100/PN 63 N/A N/A
NG DN 100/PN 100 DN 100/PN 100 N/A N/A
Place #
13
Stem style Details Image
1 Straight
2 Ta p er e d
Minimum immersion length = 1-in. (25 mm)
Minimum immersion length = 1-in. (25 mm)
Ref.
page
60
60
3 Stepped
Emerson.com/Rosemount
Minimum immersion length = 3-in. (75 mm)
60
23
Page 24
Rosemount 114C
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Place #s
14-15
Thermowell material Details
SC 316/316L dual rated 61
SD 316/316L dual rated (NORSOK)
SF 304/304L dual rated 61
CS Carbon steel (A-105) 61
SG 316Ti SST 61
SH 316/316L SST with tantalum sheath
SJ 316/316L SST with PFA coating 61
SK 304/304L SST with PTFE coating 61
SL 310 SST 61
SM 321 SST 61
Must order the Q8 Material Certificate to get NORSOK documentation
Only available as a straight stem profile with a 0.75 diameter thus requires option A075 for English units
June 2019
Ref.
page
62
62
SN 321H SST 61
SR 904L SST 61
SP 347 SST 61
AB Alloy B3 61
AC Alloy C-276 61
AD Alloy C-4 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 61
AE Alloy C-22 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 61
AF Alloy C-22 (with 316/316L SST flange) Not available with G (Fully forged) mounting style 61
AG Alloy 20 61
AH Alloy 400 61
AJ Alloy 400 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 61
AK Alloy 600 61
AL Alloy 600 (with 304/304L SST flange) Not available with G (Fully forge) mounting style 61
AM Alloy 601 61
AN Alloy 625 61
AP Alloy 800 61
AQ Alloy 800H/HT 61
AR Alloy 825 61
AU Alloy C-20 61
AS Alloy F44 Mo6 61
CA Chrome-Moly Grade B-11/F-11 Class II 61
CB Chrome-Moly Grade B-22/ F-22 Class III 61
24
Emerson.com/Rosemount
Page 25
June 2019
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
CC Chrome-Moly Grade F-91 61
NK Nickel 200 61
TT Titanium Grade 2 61
DS Super duplex SST Grade F-53 61
DT Super duplex – NORSOK
DU Duplex 2205 Grade F51 61
DV Duplex 2205 – NORSOK
Place #s
16-18
Head length (H)
xx.x-in., 2.25 to 11.25-in. in 1/4-in. increments (when ordered with dimension units code E)
xxx
Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 2.25-in. for flanges under Class 900)
xxx mm, 45 to 225 mm in 5 mm increments (when ordered with dimension units code M)
xxx
Example of a 50 mm length: 050 (default head length = 60 mm for flanges under Class 900)
Must order the Q8 Material Certificate to get NORSOK documentation
Must order the Q8 Material Certificate to get NORSOK documentation
Rosemount 114C
62
62
Ref.
page
63
63
Place #
19
Instrument connection Details Image
1
A
B
C
D M18 1.5p 64
E M20 1.5p 64
F M24 1.5p 64
G G 1/2-in. (BSPF) 64
H G 3/4-in. (BSPF) 64
J M27 2p 64
K M14 1.5p 64
/2–14 NPT
1
/2–14 NPSM 64
3
/4–14 NPT 64
Female threads
Options (include with selected model number)
Sensor/thermowell assemble to options Details
Hand tight assembly of sensor and
XT
thermowell
Process-ready assembly of sensor and
XW
thermowell
Ensures sensor is threaded into thermowell but only hand tightened 65
Ensures sensor is threaded into thermowell and torqued for process-ready installation
Ref.
page
64
Ref.
page
65
Emerson.com/Rosemount
25
Page 26
Rosemount 114C
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Extended product warranty
WR3 3-year limited warranty
WR5 5-year limited warranty 65
This warranty option extends manufacturer’s warranty to three or five years for manufacturer related defects
June 2019
Ref.
page
65
Thermowell calculation Details
Set of calculations to ensure thermowells are safe in certain process conditions
R21 Thermowell calculation
Note: If your chosen mounting style is flange with full penetration weld (F) then you must choose dye penetration option (Q73) to meet the ASME PTC 19.3 TW standard requirements.
NACE certification
Q35 NACE certification Meets MR0175/ISO 15156 and MR0103 requirements 66
PMI testing
Q76 PMI testing Verifies chemical composition of material 66
Material certification
Q8 Material certification
Certificate for material conformance and traceability in accordance with EN 10204 type 3.1
Material tests
M01 Low temperature Charpy Test
M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 67
Measures the low temperature ductility of the material. This option drives a different weld documentation.
Ref.
page
65
Ref.
page
Ref.
page
Ref.
page
67
Ref.
page
67
Surface finish
Q16 Certification Certificate showing measured surface finish values 68
R14 Finish < Ra 0.3 μm (12 μin) Improves surface roughness of thermowell 68
Electropolish
R20 Electropolish Improve smoothness and surface quality 68
Hydrostatic external pressure test
Q5 Standard external pressure test
Q9 Extended external pressure test Same as standard external pressure test but tested for twice as long 69
Verifies structural quality and checks for leaks at thermowell process connection and stem
Hydrostatic internal pressure test
Q85 Standard internal pressure test Verifies internal structural integrity of thermowell 69
Q86 Extended internal pressure test Same as standard internal pressure test but tested for twice as long 70
26
Emerson.com/Rosemount
Ref.
page
Ref.
page
Ref.
page
68
Ref.
page
Page 27
June 2019
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Canadian Registration Number
Q17 Canadian Registration Number
Canadian approvals for all provinces (Approved materials in reference section)
Dye penetration test
Q73 Dye penetration test Checks quality of welds and material 70
Rosemount 114C
Ref.
page
70
Ref.
page
Wall thickness test
Q83 Ultrasonic test Checks the bore concentricity of the thermowell 71
Special cleaning
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 71
Thermowell markings
R40 Test markings on thermowell
External marking of the thermowell for specific tests (see reference page for list of tests)
Phased array test
Q80 Phased array test
Verifies the quality of full penetration flange welds using ultrasonic technology
X-ray/radiograph test
Q81 X-ray/radiograph Verifies quality of full penetration flange welds 72
Flange welding documentation
Q66 Procedure Qualification Records (PQR)
Welder Performance Qualifications
Q67
(WPQ)
Q68 Welding Procedure Specifications (WPS)
A record of a test weld performed and tested rigorously to ensure that the procedure will produce good weld.
A test certificate that shows whether a welder possesses the necessary experience and knowledge to perform the specifications of a particular weld procedure.
A formal written document that describes and provides direction to a welder or welding operator for making sound and quality production welds per code requirement.
Spherical tip
Ref.
page
Ref.
page
Ref.
page
71
Ref.
page
72
Ref.
page
Ref.
page
72
72
72
Ref.
page
R60 Spherical tip Changes the flat tip to spherical 72
Plug and chain
R06 Stainless steel
Protects thermowell threads when sensor is not installsed
R23 Brass 73
Emerson.com/Rosemount
Ref.
page
73
27
Page 28
Rosemount 114C
B
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Vent hole
R11 Vent hole Allows for the venting of a thermowell 73
June 2019
Ref.
page
Flange face
R09 Concentric serrations Concentric serrations on flange face per ASME B16.5 74
R10 Flat Flat flange face per ASME B16.5 or EN 1092-1 facing Type A 74
R15 Raised face, Type B2 Raise face per EN 1092-1 facing Type B2 75
R16 RTJ Ring type joint flange face per ASME B16.5 76
R18 Groove, Type D Groove, Type D per EN 1092-1 76
R19 Tongue, Type C Tongue, Type C per EN 1092-1 77
R24 Spigot, Type E Spigot Type E per EN 1092-1 78
R25 Recess, Type F Recess Type F per EN 1092-1 78
A
Root diameter (A)
x.xx-in., 0.36 to 3.15-in. in 0.01-in. increments (when ordered with dimension units code E)
Axxx
Examples: Code A040 = 0.4-in., Code A315 = 3.15-in.
x.xx mm, 10 to 80 mm in 0.5 mm increments (when ordered with dimension units code M)
Axxx
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm
Ref.
page
Ref.
page
80
80
Tip diameter (B)
x.xx-in., 0.36 to 1.83-in. in 0.01-in. increments (when ordered with dimension units code E)
Bxxx
Examples: Code B040 = 0.4-in., Code B180 = 1.80-in.
xx.x mm, 10 to 46 mm in 0.5 mm increments (when ordered with dimension units code M)
Bxxx
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm
28
Ref.
page
81
81
Emerson.com/Rosemount
Page 29
June 2019
d
t
e
A
B
C
D
E
Rosemount 114C
Table 4. Rosemount 114C Flanged Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.
Non-standard bore diameter (d) Details Image
Ref.
page
D01 0.276-in./7.0 mm
D03 0.138-in./3.5 mm 82
D04 0.386-in./9.8 mm 82
Standard = 0.26-in. (6.6 mm)
D05 0.354-in./9.0 mm 82
D06 0.433-in./11.0 mm 82
Non-standard tip thickness (t) Details Image
T01 0.197-in./5.0 mm
Standard = 0.25-in. (6.4 mm)
T02 0.236-in./6.0 mm 82
Fillet Radius (e) Details Image
E03 0.118-in./3 mm
Standard = 0.157-in.
E05 0.197-in./5 mm
(4 mm)
82
Ref.
page
82
Ref.
page
83
Flanged installation
Flanged thermowells are bolted to a mating flange which protrudes from the process. It is important to select appropriate gasket for the process conditions, to provide a seal between the flange faces. The Rosemount 114C Thermowells come standard with a raised face and spiral serrations designed per the ASME B16.5 standard. These should be installed with an inside bolt circle (IBC) gasket/ring gasket, which extends to and is centered by the bolts. Other flange face options are available.
Figure 11. Installation Components
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process
Emerson.com/Rosemount
29
Page 30
Rosemount 114C
H
A
t
N
d
U
B
B
A
C
E
A
e

Flanged thermowell drawings

June 2019
Figure 12. Flange Mounted Thermowell Drawings
Straight Tapered Stepped
(1)
A. Root diameter B. Tip diameter C. Lap flange E. Total length (U + H) H. Head length
N. Instrument connection U. Immersion length d. Bore diameter e. Fillet radius t. Tip thickness
1. Total length = U+H.
30
Emerson.com/Rosemount
Page 31
June 2019
Rosemount 114C
Table 5. Flange Mounted Thermowells
Process connection
Code P, flanged,
Code
partial penetration
weld
AA 1-in. Class 150 1-in. Class 150 1-in. Class 150 19 (.748) 22.5 (.886) 16 (.630) 19 (.748)
AB 11/2-in. Class 150 11/2-in. Class 150 11/2-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AC 2-in. Class 150 2-in. Class 150 2-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AD 3-in. Class 150 3-in. Class 150 3-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AE 4-in. Class 150 4-in. Class 150 4-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AF 6-in. Class 150 6-in. Class 150 6-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AG
AH 1-in. Class 300 1-in. Class 300 1-in. Class 300 19 (.748) 22.5 (.886) 16 (.630) 19 (.748)
AK 2-in. Class 300 2-in. Class 300 2-in. Class 300 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AM 1
AN 2-in. Class 400/600 2-in. Class 400/600 2-in. Class 400/600 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AP N/A 1-in. Class 900/1500 1-in. Class 900/1500 19 (.748) 22.5 (.886) 16 (.630) 19 (.748)
AQ N/A 1
AR N/A 2-in. Class 900/1500 2-in. Class 900/1500 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AU N/A 2-in. Class 2500 2-in. Class 2500 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AV 3-in. Class 300 3-in. Class 300 3-in. Class 300 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
GA DN 25/PN 2.5/6 DN 25/PN 2.5/6 DN 25/PN 2.5/6 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
GE
GG DN 25 PN 63/100 DN 25 PN 63/100 DN 25/PN 63/100 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
GH DN 25/PN 160 DN 25/PN 160 DN 25/PN 160 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
GK DN 25/PN 320 DN 25/PN 320 DN 25/PN 320 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
KA DN 50/PN 2.5/6 DN 50/PN 2.5/6 DN 50/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KC DN 50/PN 10/16 DN 50/PN 10/16 DN 50/PN 10/16 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KG DN 50/PN 100 DN 50/PN 100 DN 50/PN 100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KH DN 50/PN 160 DN 50/PN 160 DN 50/PN 160 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
3
/4-in. Class 300
1
AJ 1
AL 1-in. Class 400/600 1-in. Class 400/600 1-in. Class 400/600 19 (.748) 22.5 (.886) 16 (.630) 19 (.748)
AT N /A 1
FA DN 20/PN 2.5/6 DN 20/PN 2.5/6 DN 20/PN 2.5/6 17 (.669) 17 (.669) 12.7 (.500) 17 (.669)
FE
FG DN 20/PN 63/100 DN 20/PN 63/100 DN 20/PN 63/100 17 (.669) 17 (.669) 12.7 (.500) 17 (.669)
GJ DN 25/PN 250 DN 25/PN 250 DN 25/PN 250 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
GL DN 25/PN 400 DN 25/PN 400 DN 25/PN 400 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
JA DN 40/PN 2.5/6 DN 40/PN 2.5/6 DN 40/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
JE
JG DN 40/PN 63/100 DN 40/PN 63/100 DN 40/PN 63/100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
JH DN 40/PN 160 DN 40/PN 160 DN 40/PN 160 21.5 (.846) 26.5 (1.043) 16 (.630) 21.5 (.846)
JJ DN 40/PN 250 DN 40/PN 250 DN 40/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
JK DN 40/ PN 320 DN 40/ PN 320 DN 40/ PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
JL DN 40/PN 400 DN 40/PN 400 DN 40/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KE DN 50/PN 25/40 DN 50/PN 25/40 DN 50/PN 25/40 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KF DN 50/PN 63 DN 50/PN 63 DN 50/PN 63 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
/2-in. Class 300 11/2-in. Class 300 11/2-in. Class 300 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
1
/2-in. Class 400/600 11/2-in. Class 400/600 11/2-in. Class 400/600 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
DN 20/PN
10/16/25/40
DN 25/PN
10/16/25/40
DN 40/PN
10/16/25/40
Code F, flanged, full
penetration weld
3
/4-in. Class 300
1
/2-in. Class 900/1500
1
/2-in. Class 2500 11/2-in. Class 2500 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
DN 20/PN
10/16/25/40
DN 25/PN
10/16/25/40
DN 40/PN
10/16/25/40
(1)
Root
diameter
Code G, flanged, forged/no welds
3
/4-in. Class 300 17 (.669) 17 (.669) 12.5 (.495) 17 (.669)
1
1
/2-in. Class
900/1500
DN 20/PN
10/16/25/40
DN 25/PN
10/16/25/40
DN 40/PN
10/16/25/40
stepped
stem
21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
17 (.669) 17 (.669) 12.7 (.500) 17 (.669)
19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
Root
diameter
tapered stem
Tip diameter
tapered stem
Tip diameter
straight stem
Flanges per
specification
ASME B16.5
EN 1092-1
Emerson.com/Rosemount
31
Page 32
Rosemount 114C
June 2019
Table 5. Flange Mounted Thermowells
Process connection
Code P, flanged,
Code
partial penetration
weld
KJ DN 50/PN 250 DN 50/PN 250 DN 50/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KK DN 50/PN 320 DN 50/PN 320 DN 50/PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KL DN 50/PN 400 DN 50/PN 400 DN 50/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LA DN 65/PN 2.5/6 DN 65/PN 2.5/6 DN 65/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LC DN 65/PN 10/16 DN 65/PN 10/16 DN 65/PN 10/16 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LE DN 65/PN 24/40 DN 65/PN 24/40 DN 65/PN 24/40 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LF DN 65/PN 63 DN 65/PN 63 DN 65/PN 63 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LG DN 65/PN 100 DN 65/PN 100 DN 65/PN 100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LH DN 65/PN 160 DN 65/PN 160 DN 65/PN 160 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LJ DN 65/PN 250 DN 65/PN 250 DN 65/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LK DN 65/PN 320 DN 65/PN 320 DN 65/PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LL DN 65/PN 400 DN 65/PN 400 DN 65/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MA DN 80/PN 2.5/6 DN 80/PN 2.5/6 DN 80/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MC DN 80/PN 10/16 DN 80/PN 10/16 DN 80/PN 10/16 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
ME DN 80/PN 25/40 DN 80/PN 25/40 DN 80/PN 25/40 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MF DN 80/PN 63 DN 80/PN 63 DN 80/PN 63 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MG DN 80/PN 100 DN 80/PN 100 DN 80/PN 100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MH DN 80/PN 160 DN 80/PN 160 DN 80/PN 160 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MJ DN 80/PN 250 DN 80/PN 250 DN 80/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MK DN 80/PN 320 DN 80/PN 320 DN 80/PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
ML DN 80/PN 400 DN 80/PN 400 DN 80/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NA DN 100/PN 2.5/6 DN 100/PN 2.5/6 DN 100/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NC DN 100/PN 10/16 DN 100/PN 10/16 DN 100/PN 10/16 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NE DN 100/PN 25/40 DN 100/PN 25/40 DN 100/PN 25/40 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NF DN 100/PN 63 DN 100/PN 63 DN 100/PN 63 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NG DN 100/PN 100 DN 100/PN 100 DN 100/PN 100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
Code F, flanged, full
penetration weld
(1)
Code G, flanged, forged/no welds
Root
diameter
stepped
stem
Root
diameter
tapered stem
Tip diameter
tapered stem
Tip diameter
straight stem
Flanges per
specification
EN 1092-1
1. Dimensions are in millimeters (inches).
Table 6. External Pressure Test–EN 1092-1
EN 1092-1 flanged thermowells
Nominal pressure (bar) Test pressure (bar)
16 40
40 100
100 250
Test to 2.5 nominal pressure rating
32
Emerson.com/Rosemount
Page 33
June 2019

Rosemount 114C Van Stone Thermowells

Rosemount 114C
Emerson.com/Rosemount
33
Page 34
Rosemount 114C
Model
Instrument
connection threads
Head
length (H)
Thermowell
material
Stem
style
Process
connection
Mounting
style
Immersion
length (U)
Units
114C X XXXXXXXXXVXXXX
16151413121198765432110 191817
(5) Units
English (E)
Metric (M)
(6-9) Immersion length (U)
XXXX
XXXX
(10) Mounting style
Van Stone (V)
(11-12) Process connections
AA
1-in. Class 150
AB AC
1½-in. Class 150
2-in. Class 150
(13) Stem style
1
Straight stem
2 3
Tapered stem Stepped stem
(14-15) Thermowell material
SC
316/316L SST
SF CS
304/304L SST
Carbon steel
(16-18) Head length (H)
XXX
XXX
(19) Instrument connection
A
½-14 NPT
B
½-14 NPSM
Options
XX, XXX, XX
Common options
External pressure test
Q5
R21
Q35
Q8
NACE certification Wake frequency calculation
Material certification
C01
Van Stone w/no cover flange
C02
Van Stone w/SST cover flange
0.5in to 42in (E) Example: 0.5in=0005,
42in=0420 25mm to 1165mm (M) Example: 25mm=0025, 1165mm=1165
2.25in to 11.25in (E) Example: 2.25in=022, 10in=100
40mm to 225mm (M) Example: 40mm=040, 225mm=225
D
M18 x 1.5p
E
M20 x 1.5p
F
M24 x 1.5p
June 2019

Van Stone thermowell overview

Van Stone/lap Joint thermowells are mounted between the mating flange and lap joint flange. This unique design enables thermowell designers to specify thermowell flange materials different than the thermowell stem material; flanges are easily replaceable. These thermowells allow use of different thermowell materials for the flange contacting the process and overlaying flange which can save material and manufacturing costs. They are a good choice for corrosive applications, because there are no welds so weld-joint corrosion is eliminated. The Emerson standard for the Van Stone thermowell is a raised face style made of carbon steel. Other styles and flange materials are also available.
The standard offering figure below shows the thermowell configurations that can typically be shipped in two weeks or less.
Figure 13. Standard Offering–Van Stone
The common options shown in Figure 13 represent a partial offering; reference the Rosemount 114C Van Stone Ordering Information for a full list of available options.
Figure 14. Van Stone Thermowell Components
A
A. Instrument connection B. Process connection
Note
Wetted surface includes flange face and immersion length (U).
34
H
B
U
H. Head length U. Immersion length
Emerson.com/Rosemount
Page 35
June 2019
Rosemount 114C
Use the form below to record your model code:
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem
style
Thermowell
material
Head length (H)
Instrument connection
Options
114C V
1234 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 X X X X X
Emerson.com/Rosemount
35
Page 36
Rosemount 114C
U

Van Stone ordering information

Figure 15. Model Number Ordering Example
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem
style
Thermowell
material
Head length (H)
Instrument connection
June 2019
Options
114C M 0150 V A B 1 S C 0 5 0 A
1234 5 6789 10 11 12 13 14 15 16 17 18 19 X X X X X
The numbers below the model number ordering example correlate to the character place numbers in the second column of the ordering table.
Table 7. Rosemount 114C Van Stone Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
Place #s
1-4
114C Barstock temperature thermowell
Place #
E English units (inches)
M Metric units (mm) 59
Model Details
Dimension units Details
5
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip wall thickness of 0.25-in. (6.4 mm). Default cover flange material is carbon steel.
Specifies whether length units will be in inches (in.) or millimeters (mm)
WR5,
Q76...
Ref.
page
N/A
Ref.
page
59
Place #
6-9
xxxx
xxxx
Place #
10
V Van Stone, lap flange Default cover flange material is carbon steel N/A
Place #s
11-12
AA 1-in. Class 150 N/A
AB 11/2-in. Class 150 N/A
AC 2-in. Class 150 N/A
Immersion length (U)
xx.x-in., 1.0 to 100-in. in 1/4-in. increments (when ordered with dimension units code E)
Example of a 6.25-in. length where the second decimal is dropped off: 0062
xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
Example of a 25 mm length: 0025
Mounting style Details
Process connection Details
Ref.
page
59
59
Ref.
page
Ref.
page
36
Emerson.com/Rosemount
Page 37
June 2019
Table 7. Rosemount 114C Van Stone Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
AH 1-in. Class 300 N/A
AJ 11/2-in. Class 300 N/A
AK 2-in. Class 300 N/A
AL 1-in. Class 400/600 N/A
AM 11/2-in. Class 400/600 N/A
AN 2-in. Class 400/600 N/A
AP 1-in. Class 900/1500 N/A
AQ 11/2-in. Class 900/1500 N/A
AR 2-in. Class 900/1500 N/A
AS 1-in. Class 2500 N/A
AT 11/2-in. Class 2500 N/A
AU 2-in. Class 2500 N/A
Rosemount 114C
Place #
13
1 Straight
2 Ta pe r e d
3 Stepped
Stem style Details Image
Minimum immersion length = 1-in. (25 mm)
Minimum immersion length = 1-in. (25 mm)
Minimum immersion length = 3-in. (75 mm)
Ref.
page
60
60
60
Place #s
14-15
SC 316/316L dual rated 61
SD 316/316L dual rated (NORSOK)
SF 304/304L dual rated 61
Thermowell material Details
Must order the Q8 Material Certificate to get NORSOK documentation
Emerson.com/Rosemount
Ref.
page
62
37
Page 38
Rosemount 114C
Table 7. Rosemount 114C Van Stone Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
CS Carbon steel (A-105) 61
SG 316Ti SST 61
SH 316/316L SST with tantalum sheath 61
SJ 316/316L SST with PFA coating 61
SK 304/304L SST with PTFE coating 61
SL 310 SST 61
SM 321 SST 61
SN 321H SST 61
SR 904L SST 61
SP 347 SST 61
AB Alloy B3 61
AC Alloy C-276 61
June 2019
AG Alloy 20 61
AH Alloy 400 61
AK Alloy 600 61
AM Alloy 601 61
AN Alloy 625 61
AP Alloy 800 61
AQ Alloy 800H/HT 61
AR Alloy 825 61
AU Alloy C-20 61
MO Molybdenum 61
CA Chrome-Moly Grade B-11/F-11 Class II 61
CB Chrome-Moly Grade B-22/ F-22 Class III 61
CC Chrome-Moly Grade F-91 61
NK Nickel 200 61
TT Titanium Grade 2 61
DS Super duplex SST Grade F-53 61
DT Super duplex – NORSOK
DU Duplex 2205 Grade F51 61
DV Duplex 2205 – NORSOK
Must order the Q8 Material Certificate to get NORSOK documentation
Must order the Q8 Material Certificate to get NORSOK documentation
62
62
38
Emerson.com/Rosemount
Page 39
June 2019
H
Table 7. Rosemount 114C Van Stone Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
Rosemount 114C
Place #s
16-18
xxx
xxx
Place #
19
A
B
C
D M18 1.5p 64
E M20 1.5p 64
F M24 1.5p 64
Head length (H)
xx.x-in., 1.75to 11.25-in. in 1/4-in. increments (when ordered with Dimension units code E)
Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 2.25-in. for flanges under Class 900)
xxx mm, 40 to 225 mm in 5 mm increments (when ordered with Dimension units code M)
Example of a 50 mm length: 050 (default head length = 60 mm for flanges under Class 900)
Instrument connection Details Image
1
/2–14 NPT
1
/2–14 NPSM 64
3
/4–14 NPT 64
Female threads
Ref.
page
63
63
Ref.
page
64
G G 1/2-in. (BSPF) 64
H G 3/4-in. (BSPF) 64
J M27 2p 64
K M14 1.5p 64
Options (include with selected model number)
Sensor/thermowell assemble to options Details
Extended product warranty Details
Hand tight assembly of sensor and
XT
thermowell
Process-ready assembly of sensor and
XW
thermowell
WR3 3-year limited warranty
WR5 5-year limited warranty 65
Ref.
page
Ensures sensor is threaded into thermowell but only hand tightened 65
Ensures sensor is threaded into thermowell and torqued for process-ready installation
65
Ref.
page
This warranty option extends manufacturer’s warranty to three or five years for manufacturer related defects
65
Emerson.com/Rosemount
39
Page 40
Rosemount 114C
Table 7. Rosemount 114C Van Stone Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
June 2019
Thermowell calculation Details
R21 Thermowell calculation
Set of calculations to ensure thermowells are safe in certain process conditions
NACE certification Details
Q35 NACE certification Meets MR0175/ISO 15156 and MR0103 requirements 66
Ref.
page
65
Ref.
page
PMI testing Details
Q76 PMI testing Verifies chemical composition of material 66
Material certification Details
Q8 Material certification
Certificate for material conformance and traceability in accordance with EN 10204 type 3.1
Material tests Details
M01 Low temperature Charpy Test Measures the low temperature ductility of the material 67
M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 67
Surface finish Details
Q16 Certification Certificate showing measured surface finish values 68
R14 Finish < Ra 0.3 μm (12 μin) Improves surface roughness of thermowell 68
Electropolish Details
R20 Electropolish Improve smoothness and surface quality 68
Stepped instrument threads Image
Ref.
page
Ref.
page
67
Ref.
page
Ref.
page
Ref.
page
Ref.
page
R61 Stepped instrument threads 68
Roughened stem Details
R62 Roughened stem
Roughens the last 4.7-in. (120 mm) of the stem
40
Image
Emerson.com/Rosemount
Ref.
page
N/A
Page 41
June 2019
Table 7. Rosemount 114C Van Stone Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
Rosemount 114C
Hydrostatic external pressure test Details
Q5 Standard external pressure test
Q9 Extended external pressure test Same as standard external pressure test but tested for twice as long 69
Verifies structural quality and checks for leaks at thermowell process connection and stem
Ref.
page
68
Hydrostatic internal pressure test Details
Q85 Standard internal pressure test Verifies internal structural integrity of thermowell 69
Q86 Extended internal pressure test Same as standard internal pressure test but tested for twice as long 70
Canadian Registration Number Details
Q17 Canadian Registration Number
Canadian approvals for all provinces (Approved materials in reference section)
Dye penetration test Details
Q73 Dye penetration test Checks quality of welds and material 70
Wall thickness test Details
Q83 Ultrasonic test Checks the bore concentricity of the thermowell 71
Special cleaning Details
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 71
Thermowell markings Details
R40 Test markings on thermowell
External marking of the thermowell for specific tests (see reference page for list of tests)
Spherical tip Details
Ref.
page
Ref.
page
70
Ref.
page
Ref.
page
Ref.
page
Ref.
page
71
Ref.
page
R60 Spherical tip Changes the flat tip to spherical 72
Plug and chain Details
R06 Stainless steel
Protects thermowell threads when sensor is not installed
R23 Brass 73
Vent hole Details
R11 Vent hole Allows for the venting of a thermowell 73
Flange face Details
R09 Concentric serrations Concentric serrations on flange face per ASME B16.5 74
R16 RTJ Ring type joint flange face per ASME B16.5 75
Emerson.com/Rosemount
Ref.
page
73
Ref.
page
Ref.
page
41
Page 42
Rosemount 114C
d
e
Table 7. Rosemount 114C Van Stone Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
June 2019
A
Root diameter (A)
x.xx-in., 0.36 to 3.15-in. in 0.01-in. increments (when ordered with dimension units code E)
Axxx
Examples: Code A040 = 0.4-in, Code A315 = 3.15-in.
xx.x mm, 10 to 80 mm in 0.5 mm increments (when ordered with dimension units code M)
Axxx
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm
B
Tip diameter (B)
x.xx-in., 0.36 to 1.83-in. in 0.01-in. increments (when ordered with dimension units code E)
Bxxx
Examples: Code B040 = 0.4-in, Code B180 = 1.80-in.
xx.x mm, 10 to 46 mm in 0.5 mm. increments (when ordered with dimension units code M)
Bxxx
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm
Non-standard bore diameter (d) Details Image
Ref.
page
80
80
Ref.
page
81
81
Ref.
page
D01 0.276-in./7.0 mm
D03 0.138-in./3.5 mm 82
D04 0.386-in./9.8 mm 82
D05 0.354-in./9.0 mm 82
D06 0.433-in./11.0 mm 82
Standard = 0.26-in. (6.6 mm)
Non-standard tip thickness (t) Details Image
T01 0.197-in./5.0 mm
Standard = 0.25-in.
T02 0.236-in./6.0 mm
(6.4 mm)
t
Fillet Radius (e) Details Image
E03 0.118-in./3 mm
Standard = 0.157-in.
E05 0.197-in./5 mm
(4 mm)
82
Ref.
page
82
Ref.
page
83
42
Emerson.com/Rosemount
Page 43
June 2019
f
A
B
C
D
E
Rosemount 114C
Table 7. Rosemount 114C Van Stone Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
Van stone stub thickness Details Image
F01 0.591-in. (15 mm)
Ref.
page
Standard = 0.394-in.
F02 0.787-in. (20 mm)
(10 mm)
Lap flange material for Van Stone design Details
C01 No flange Provides a Van Stone stem without a lap flange. 84
C02 316/316LSST flange Provides a Van Stone stem with a 316/316LSST lap flange. 84
C03 Flange per stem material
Van Stone installation
Van Stone thermowells are installed using a lap joint flange which slips over the stub end of the thermowell. The lap joint flange has no flange face. Instead the flange is bolted over the stub end which acts as the flange face and compresses the gasket. The Rosemount 114C Thermowells come standard with spiral serrations on the stub end designed per the ASME B16.5 standard. These should be installed with an inside bolt circle (IBC) gasket/ring gasket, which extends to and is centered by the bolts. Other flange face options are available.
Provides a Van Stone stem with a matching lap flange per stem material. Coatings do not apply to lap flange.
Figure 16. Installation Components
83
Ref.
page
84
Emerson.com/Rosemount
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process
43
Page 44
Rosemount 114C
H
t
N
d
U
E
F
G
C
A
e

Van Stone thermowell drawings

June 2019
Figure 17. Van Stone/Lap Flanged Mounted Thermowell Drawings
Straight Tapered Stepped
A
B
A. Root diameter B. Tip diameter C. Head diameter E. ASME B16.5 lap flange
F. St ub th ic kn es s H. Head length N. Instrument connection ( U. Immersion length
1
/2-in. NPT)
(1)
A
B
d. Bore diameter e. Fillet radius t. Tip thickness
1. Total length = U + H.
44
Emerson.com/Rosemount
Page 45
June 2019
Rosemount 114C
Table 8. Van Stone/Lap Flanged Mounted Thermowells
Code V, Van Stone lap
flange mounting style Lagging
Code
Process connection
AA 1-in. Class 150
AB 1
AC 2-in. Class 150
AH 1-in. Class 300
AJ 1
AK 2-in. Class 300
AL 1-in. Class 400/600
AM 1
AN 2-in. Class 400/600
AP 1-in. Class 900/1500
AQ 1
AR 2-in. Class 900/1500
AS 1-in. Class 2500
AT 1
AU 2-in. Class 2500
1
/2-in. Class 150
1
/2-in. Class 300
1
/2-in. Class 400/600
1
/2-in. Class 900/1500
1
/2-in. Class 2500
diameter
“C”
1.31
(33.4)
1.90
(48.3)
2.37
(60.3)
1.31
(33.4)
1.90
(48.3)
2.37
(60.3)
1.31
(33.4)
1.90
(48.3)
2.37
(60.3)
1.31
(33.4)
1.90
(48.3)
2.37
(60.3)
1.31
(33.4)
1.90
(48.3)
2.37
(60.3)
Stub
diameter
K
standard
raised
face
1.99
(50.8)
2.87 (73)
3.62
(92.1)
1.99
(50.8)
2.87 (73)
3.62
(92.1)
1.99
(50.8)
2.87 (73)
3.62
(92.1)
1.99
(50.8)
2.87 (73)
3.62
(92.1)
1.99
(50.8)
2.87 (73)
3.62
(92.1)
Stub
diameter
K ring
type joint
option
R16
2.50
(63.5)
3.25
(82.5)
(102)
2.75 (70)
3.56
(90.5)
4.25
(108)
2.75 (70)
3.56
(90.5)
4.25
(108)
2.81
(71.5)
3.62 (92)
4.88
(124)
3.25
(82.5)
4.50
(114)
5.25
(133)
(1)
4
Stub
thickness
“F”
standard
raised face
10
(.394)
Stub
thickness
“F”
ring type
joint
option R16
0.644
(16.35)
0.644
(16.35)
0.644
(16.35)
0.644
(16.35)
0.644
(16.35)
0.707
(17.92)
0.644
(16.35)
0.644
(16.35)
0.707
(17.92)
0.644
(16.35)
0.644
(16.35)
0.707
(17.92)
0.644
(16.35)
0.707
(17.92)
0.707
(17.92)
Root
diameter
stepped
stem
0.75 (19)
0.85
(21.5)
0.85
(21.5)
0.75 (19)
0.85
(21.5)
0.85
(21.5)
0.75 (19)
0.85
(21.5)
0.85
(21.5)
0.75 (19)
0.85
(21.5)
0.85
(21.5)
0.75 (19)
0.85
(21.5)
0.85
(21.5)
Root
diameter
tapered
stem
0.89
(22.5)
1.04
(26.5)
1.04
(26.5)
0.89
(22.5)
1.04
(26.5)
1.04
(26.5)
0.89
(22.5)
1.04
(26.5)
1.04
(26.5)
0.89
(22.5)
1.04
(26.5)
1.04
(26.5)
0.89
(22.5)
1.04
(26.5)
1.04
(26.5)
Tip
diameter
tapered
stem
0.63 (16)
0.71 (18)
0.71 (18)
0.63 (16)
0.71 (18)
0.71 (18)
0.63 (16)
0.71 (18)
0.71 (18)
0.63 (16)
0.71 (18)
0.71 (18)
0.63 (16)
0.71 (18)
0.71 (18)
Tip
diameter
straight
stem
.75
(19)
.85
(21.5)
.85
(21.5)
.75
(19)
.85
(21.5)
.85
(21.5)
.75
(19)
.85
(21.5)
.85
(21.5)
.75
(19)
.85
(21.5)
.85
(21.5)
.75
(19)
.85
(21.5)
.85
(21.5)
1. Dimensions are in inches (millimeters).
Emerson.com/Rosemount
45
Page 46
Rosemount 114C

Rosemount 114C Welded Thermowells

June 2019
46
Emerson.com/Rosemount
Page 47
June 2019
Model
Instrument
connection threads
Head
length (H)
Thermowell
material
Stem
style
Process
connection
Mounting
style
Immersion
length (U)
Units
114C X XXXXXXXXXWXXXX
16151413121198765432110 191817
(5) Units
English (E)
Metric (M)
(6-9) Immersion length (U)
XXXX
XXXX
(10) Mounting style
Socket weld (W)
(11-12) Process connections
AA
¾-in. Pipe
AB
1-in. Pipe
(13) Stem style
1
Straight stem
2 3
Tapered stem
Stepped stem
(14-15) Thermowell material
SC
316/316L SST
SF
304/304L SST
(16-18) Head Length (U)
XXX
XXX
(19) Instrument connection
A
½-14 NPT
B
½-14 NPSM
Options
XX, XXX, XX
Common options
NACE certification
Q35
Q8
R21
Q73
Thermowell calculation
Material certification
Dye penetration test
0.5- to 42-in. (E) Example: 0.5-in. = 0005, 42-in. = 0420
1.75- to 11.25-in. (E) Example: 1.75-in. = 017, 10-in. = 100
25 to 1165 mm (M) Example: 25 mm = 0025, 1165 mm = 1165
40 to 225 mm (M) Example: 40 mm = 040, 225 mm = 225
AC 1 1/4-in. Pipe
AD
1½-in. Pipe
Weld in (D)
D M18 x 1.5p
E
M20 x 1.5p
F
M24 x 1.5p
U
H
B
A
Rosemount 114C

Welded thermowell overview

Welded thermowells are permanently welded to process pipes or tanks. Welded thermowells have the highest pressure rating and are generally used in applications with high velocity flow, high temperature, or extremely high pressure. They are necessary where a leak-proof seal is required.
The standard offering figure below shows the thermowell configurations that can typically be shipped in two weeks or less.
Figure 18. Standard Offering–Welded
The common options shown in Figure 18 represent a partial offering; reference the Rosemount 114C Welded Ordering Information for a full list of available options.
Figure 19. Welded Thermowell Components
A. Instrument connection B. Process connection (dependent on weld point)
Note
Actual wetted surface varies; it is measured from the weld point to the thermowell tip.
Emerson.com/Rosemount
Socket weld Weld-in
H
A
U. Immersion length H. Head length
B
U
47
Page 48
Rosemount 114C
June 2019
Use the form below to record your model code:
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Instrument connection
Options
114C
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 X X X X X
48
Emerson.com/Rosemount
Page 49
June 2019
U
U

Welded ordering information

Figure 20. Model Number Ordering Example
Model Units
Immersion
length (U)
Mounting
style
Process
connection
Stem style
Thermowell
material
Head length (H)
Rosemount 114C
Instrument connection
Options
114C E 0060 W A B 1 S C 0 5 0 A
1234 5 6789 10 11 12 13 14 15 16 17 18 19 X X X X X
WR5,
Q76...
The numbers below the model number ordering example correlate to the character place numbers in the second column of the ordering table.
Table 9. Rosemount 114C Welded Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
Place #s
1-4
114C Barstock temperature thermowell
Place #
E English units (inches)
M Metric units (mm) 59
Place #
6-9
Model Details
Dimension units Details
5
Immersion length (U)
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip wall thickness of 0.25-in. (6.4 mm)
Specifies whether length units will be in inches (in.) or millimeters (mm)
Ref.
page
N/A
Ref.
page
59
Ref.
page
xxxx
Example of a 6.25-in. length where the second decimal is dropped off: 0062
xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
xxx-in., 1 to 100-in. in 1/4-in. increments (when ordered with dimension units code E)
xxxx
Example of a 50 mm length: 0050
Place #
10
W Welded–socket weld N/A
D Welded–weld-in (only available in tapered stem profile) N/A
Place #s
11-12
Mounting style Details
Process connections Details
Welded–socket weld (W) Welded–weld-in (D) (only available in tapered stem profile)
3
AA
/4-in. pipe
AB 1-in. pipe 1-in. pipe N/A
AC 11/4-in pipe 11/4-in. pipe N/A
AD 11/2-in. pipe 11/2-in. pipe N/A
AE N/A
3
/4-in. pipe N/A
Custom diameters (required for Root [Axxx] and tip [Bxxx] modifications)
59
59
Ref.
page
Ref.
page
N/A
Emerson.com/Rosemount
49
Page 50
Rosemount 114C
Table 9. Rosemount 114C Welded Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
DA N/A DIN 43772-4-7 (18 h7/3.5 mm bore/M14) N/A
DB N/A DIN 43772-4-7 (24 h7/7.0 mm bore/M18) N/A
DC N/A DIN 43772-4-7 (26 h7/7.0 mm bore/G1/2 or M20) N/A
DD N/A DIN 43772-4-7 (26 h7/9.0 mm bore/G1/2 or M20) N/A
DE N/A DIN 43772-4-7 (32 h11/11.0 mm bore/G3/4 or M27) N/A
DH N/A
Place #
13
Stem style Details Image
Custom diameters (required for root (Axxx) and tip ( Bxxx) modifications
June 2019
N/A
Ref.
page
1 Straight
2 Ta p er e d
3 Stepped
Place #s
14-15
SC 316/316L dual rated 61
SD 316/316L dual rated (NORSOK)
SF 304/304L dual rated 61
CS Carbon steel (A-105) 61
SG 316Ti SST 61
SL 310 SST 61
SM 321 SST 61
SN 321H SST 61
SR 904L SST 61
Thermowell material Details
Minimum immersion length = 1-in. (25 mm)
Minimum immersion length = 1-in. (25 mm)
Minimum immersion length = 3-in. (75 mm)
Must order the Q8 Material Certificate to get NORSOK documentation
60
60
60
Ref.
page
62
SP 347 SST 61
AB Alloy B3 61
AC Alloy C-276 61
AG Alloy 20 61
AH Alloy 400 61
AK Alloy 600 61
AM Alloy 601 61
AN Alloy 625 61
AP Alloy 800 61
AQ Alloy 800H/HT 61
50
Emerson.com/Rosemount
Page 51
June 2019
H
Rosemount 114C
Table 9. Rosemount 114C Welded Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
AR Alloy 825 61
AU Alloy C-22 61
AS Alloy F44 Mo6 61
MO Molybdenum 61
CA Chrome-Moly Grade B-11/F-11 Class II 61
CB Chrome-Moly Grade B-22/ F-22 Class III 61
CC Chrome-Moly Grade F-91 61
NK Nickel 200 61
TT Titanium Grade 2 61
DS Super duplex SST Grade F-53 61
DT Super duplex – NORSOK
Must order the Q8 Material Certificate to get NORSOK documentation
DU Duplex 2205 Grade F51 61
DV Duplex 2205 – NORSOK
Place #s
16-18
Head length (H)
Must order the Q8 Material Certificate to get NORSOK documentation
H
62
62
Ref.
page
xxx
Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 1.75-in.)
xxx mm, 40 to 225 mm in 5-mm increments (when ordered with dimension units code M)
xx.x-in., 1.75 to 11.25-in. in 1/4-in. increments (when ordered with dimension units code E)
xxx
Example of a 50 mm length: 050 (default head length = 45 mm)
Place #
19
A
B
C
Instrument connection Details Image
1
/2–14 NPT
1
/2–14 NPSM 64
3
/4–14 NPT 64
D M18 1.5p 64
E M20 1.5p 64
Female threads
F M24 1.5p 64
G G 1/2-in. (BSPF) 64
H G 3/4-in. (BSPF) 64
J M27 2p 64
K M14 1.5p 64
63
63
Ref.
page
64
Emerson.com/Rosemount
51
Page 52
Rosemount 114C
Table 9. Rosemount 114C Welded Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
June 2019
Options (include with selected model number)
Sensor/thermowell assemble to options Details
Hand tight assembly of sensor and
XT
thermowell
Sensor is threaded into thermowell but only hand tightened 65
Extended product warranty Details
WR3 3-year limited warranty
WR5 5-year limited warranty 65
This warranty option extends manufacturer’s warranty to three or five years for manufacturer related defects
Thermowell calculation Details
R21 Thermowell calculation
Set of calculations to ensure thermowells are safe in certain process conditions
NACE certification Details
Q35 NACE certification Meets MR0175/ISO 15156 and MR0103 requirements 66
PMI testing Details
Q76 PMI testing Verifies chemical composition of material 66
Material certification Details
Q8 Material certification
Certificate for material conformance and traceability in accordance with EN 10204 type 3.1
Material tests Details
Ref.
page
Ref.
page
65
Ref.
page
65
Ref.
page
Ref.
page
Ref.
page
67
Ref.
page
M01 Low temperature Charpy Test Measures the low temperature ductility of the material 67
M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 67
Surface finish Details
Q16 Certification Certificate showing measured surface finish values 68
R14 Finish < Ra 0.3μm (12μin) Improves surface roughness of thermowell 68
Electropolish Details
R20 Electropolish Improves smoothness and surface quality 68
Hydrostatic internal pressure test Details
Q85 Standard internal pressure test Verifies internal structural integrity of thermowell 69
Q86 Externded internal pressure test
52
Same as standard internal pressure test but tested for twice as long
Emerson.com/Rosemount
Ref.
page
Ref.
page
Ref.
page
70
Page 53
June 2019
A
B
Table 9. Rosemount 114C Welded Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
Rosemount 114C
Canadian Registration Number Details
Q17 Canadian Registration Number
Canadian approvals for all provinces (Approved materials in reference section)
Dye penetration test Details
Q73 Dye penetration test Checks quality of welds and material 70
Ref.
page
70
Ref.
page
Wall thickness test Details
Q83 Ultrasonic test Checks the bore concentricity of the thermowell 71
Special cleaning Details
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 71
Thermowell markings Details
R40 Test markings on thermowell
External marking of the thermowell for specific tests (see reference page for list of tests)
Spherical tip Details
R60 Spherical tip Changes the flat tip to spherical 72
Plug and chain Details
R06 Stainless steel
R23 Brass 73
Protects thermowell threads when sensor is not installed
Vent hole Details
Ref.
page
Ref.
page
Ref.
page
71
Ref.
page
Ref.
page
73
Ref.
page
R11 Vent hole Allows for the venting of a thermowell 73
Root diameter (A)
x.xx-in., 0.36 to 3.15-in. in 0.01-in. increments (when ordered with dimension units code E)
Axxx
Examples: Code A040 = 0.4-in, Code A315 = 3.15-in.
xx.xx mm, 10 to 80 mm in 0.5 mm increments (when ordered with dimension units code M)
Axxx
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm
Tip diameter (B)
x.xx-in., 0.36 to 1.83-in. in 0.01-in. increments (when ordered with dimension units code E)
Bxxx
Examples: Code B040 = 0.4-in, Code B180 = 1.80-in.
xx.xx mm, 10 to 46 mm in 0.5 mm. increments (when ordered with dimension units code M)
Bxxx
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm
Emerson.com/Rosemount
Ref.
page
80
80
Ref.
page
81
81
53
Page 54
Rosemount 114C
A
B C
D
E
F
June 2019
Table 9. Rosemount 114C Welded Ordering Information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time. The Expanded offering is subject to additional delivery lead time.
Non-standard bore diameter (d) Details Image
Ref.
page
D01 0.276-in./7.0 mm
D03 0.138-in./3.5 mm 82
D04 0.386-in./9.8 mm 82
Standard = 0.26-in. (6.6 mm)
d
82
D05 0.354-in./9.0 mm 82
D06 0.433-in./11.0 mm 82
Non-standard tip thickness (t) Details Image
T01 0.197-in./5.0 mm
Ref.
page
82
Standard = 0.25-in. (6.4 mm)
T02 0.236-in./6.0 mm 82
t
Socket weld installation
Socket weld thermowells are typically welded into a socket weld fitting. Welds should be designed according to the appropriate standards. It is important to order a head length (H) that leaves enough space so the instrument threads will not be deformed by welding at installation. The customer should also make sure the root diameter of the thermowell will fit through the inner diameter of the weld fitting.
Note
When specified in a thermowell calculation, the unsupported length for a socket weld thermowell is from the point of weld (B shown on Figure 21 on page 54) to the thermowell tip.
Figure 21. Installation Components
A. Thermowell B. Weld C. Socket weld fitting
1
D.
/16-in. gap E. Weld F. Process
54
Emerson.com/Rosemount
Page 55
June 2019
Rosemount 114C

Weld-in Type 4 thermowells according to DIN 43772

This section only defines the requirement necessary to provide a Type 4 thermowell according to the DIN 43772 Standard (for ordering information on weld-in thermowells outside the DIN Standard, see Table 9 on page 49).
The illustration below shows the breakdown of a model according to the DIN Standard:
Thermowell DIN 43772 – 4 – 7 – M18 1.5 200 65 16Mo3
Name
Standard number
Typ e
Thermowell inside
diameter d
Thermometer
connection thread N
Overall length L
Immersion length U
Material abbreviation
or material number
Table 10 , Tabl e 11, and Ta ble 12 show all required thermowell dimensions necessary to conform to DIN 43772 Type 4 and the
relationship to the Rosemount 114C Thermowell.
1
Ordering process
1. Select overall length (L) and immersion length (U) from Tab le 1 0. U = 65 mm L = 200 mm H = LU = 135 mm
Rosemount 114C = U = 0065 Rosemount 114C = H = 135
Table 10. DIN Required Lengths
Immersion length (U)
(mm) Code (mm) (mm) Code
65 0065 110 45 045
65 0065 140 75 075
65 0065 200 135 135
125 0125 260 135 135
275 0275 410 135 135
2. Select process connection (PC), instrument connection (IC), and bore diameter (BD) from Tab le 11. PC = 18 h7/3.5 mm IC = M14 ⫻ 1.5 BD = 3.5 mm
Rosemount 114C = 18 h7/3.5 mm = DA Rosemount 114C = M14 1.5 = K Rosemount 114C = 3.5 mm = D03
Table 11. DIN Connection Information
Overall length (L)
(U + H)
Head length (H)
Process connection (PC) Instrument connection (IC) Bore diameter (BD)
Type Code Internal threads Code (mm) Code
18 h7 DA M14 1.5 K 3.5 D03
24 h7 DB M18 1.5 D 7.0 D01
26 h7 DC G
1
/2 (BSPF) G 7.0 D01
Emerson.com/Rosemount
55
Page 56
Rosemount 114C
June 2019
Table 11. DIN Connection Information
Process connection (PC) Instrument connection (IC) Bore diameter (BD)
26 h7 DD M20 1.5 E 9.0 D05
32 h11 DE G
3
/4 (BSPF) H 11.0 D06
32 h11 DE M27 2J11.0D06
3. Determine thermowell material from Tab le 12 . Material = 316 Ti SST
Rosemount 114C = 316 Ti SST= SG
Table 12. DIN Material
Thermowell material (M) Material code
Molybdenum DIN 1.5415 EN 10273 MO
Chrome-Moly B-11 DIN 1.7335 EN 10273 CA
Chrome-Moly B-22 DIN 1.7380 EN 10273 CB
316 Ti SST DIN 1.4571 EN 10272 SG
4. Apply to Rosemount 114C model as shown below:
Metric Weld-in Tapered
0.5 mm tip thickness
114C – M – XXXX – D – XX – 2 – XX – XXX – X – T01 – XXX
UPCMHIC BD
Resulting model code example: 114C-M-0065-D-DA-2-SG-135-K-T01-D03
Figure 22. Weld Mounted Thermowell Drawings (Weld-in)
H. Head length
F_2, F_3, and H_1, refer to Table 13.
Table 13. DIN Weld Mounted Thermowells (Weld-in)
(1)
Code D, welded (weld-in) style
Head diameter “ F_2” Tip diameter “ F_3”
Code
DA DIN 43772-4-7 (18 h7/3.5 mm bore/M14) 18 h7 (+0.000/–0.018 mm) 9 ±0.27 16
DB DIN 43772-4-7 (24 h7/7 mm bore/M18) 24 h7 (+0.000/–0.021 mm) 12.5 ±0.38 16
DC DIN 43772-4-7 (26 h7/7 mm bore/G
DD DIN 43772-4-7 (26 h7/9 mm bore/G
DE DIN 43772-4-7 (32 h11/11 mm bore/G
Process connection
1
/2 or M20) 26 h7 (+0.000/–0.021 mm) 12.5 ±0.38 19
1
/2 or M20) 26 h7 (+0.000/–0.021 mm) 15 ±0.38 19
3
/4 or M27) 32 h11 (+0.000/–0.160 mm) 17 ±0.38 22
U. Immersion length
Thread length
“H_1”
1. Dimensions are in millimeters.
56
Emerson.com/Rosemount
Page 57
June 2019
H
A
t
N
d
U
B
B
A
S
A
∅∅∅

Welded thermowell drawings

Rosemount 114C
Figure 23. Weld Mounted Thermowell Drawings (Socket Weld)
Straight Tapered Stepped
(1)
A. Root diameter B. Tip diameter H. Head length N. Instrument connection
Table 14. Weld Mounted Thermowells (Socket Weld)
(1)
S. Socket size U. Immersion length d. Bore diameter t. Tip thickness
Code W, welded mounting style
Code
Socket size “ S” Root diameter “ A” Tip diameter “ B”
Process connection
AA
AB 1-in. pipe 1.32 (33.4) 0.75 (19) 0.50 (12.7)
AC 1
AD 1
1. Dimensions are in inches (millimeters).
3
/4-in. pipe 1.05 (26.67) 0.75 (19) 0.50 (12.7)
1
/4-in. pipe 1.66 (42.16) 0.75 (19) 0.50 (12.7)
1
/2-in. pipe 1.90 (48.26) 0.75 (19) 0.50 (12.7)
1. Total length = U + H.
Emerson.com/Rosemount
57
Page 58
Rosemount 114C
A
B
UH
N
June 2019
Figure 24. Weld Mounted Thermowell Drawings (Weld-in)
A. Root diameter B. Tip diameter H. Head length
Table 15. Weld Mounted Thermowells (Weld-in)
(1)
(1)
N. Instrument connection U. Immersion length
Code D, welded mounting style
Code
Root diameter “ A” Tip diameter “ B”
Process connection
AA
AB 1-in. pipe 1.315 (33.40) .846 (21.5)
AC 1
AD 1
AE Custom Specified by design modifier “AXXX” Specified by design modifier “BXXX”
3
/4-in. pipe 1.050 (26.67) .748 (19)
1
/4-in. pipe 1.660 (42.16) 1.043 (26.5)
1
/2-in. pipe 1.900 (48.26) 1.250 (31.75)
1. Dimensions are in inches (millimeters).
1. Total length = U + H.
58
Emerson.com/Rosemount
Page 59
June 2019
U
Rosemount 114C

Ordering information detail

Dimension units

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The Rosemount 114C Thermowell has the flexibility to be specified in either inches (E) or millimeters (M).
English units (inches)
If English is selected, all lengths will be in inches.
Metric
If metric is selected, all lengths will be in millimeters.

Immersion length (U)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The immersion length normally refers to the length of the thermowell stem beginning underneath the process connection to the tip of the thermowell. This length is typically specified by the process designer but the general rule is at least one-third or one-half the pipe diameter. Thermowells longer than 42-in. will be required to have an internal pressure test (Q85) performed to ensure the internal cavity integrity has not been compromised. Parallel thread thermowells have a U length that actually includes the process threads thus requiring an extra 1-in. (25 mm) for min. U length.
Table 16. Minimum Immersion Length by Profile Style
Profile
Straight 1-in. (25 mm) 2-in. (50 mm)
Tapered 1-in. (25 mm) 2-in. (50 mm)
Stepped 3 -in. (75 mm) 4-in. (100 mm)
Note
Long-length thermowells are those longer than 42-in. (1065 mm) and may be manufactured from two or three pieces of bar stock.
Minimum length
Emerson.com/Rosemount
Minimum length
(parallel threads)
59
Page 60
Rosemount 114C
June 2019

Stem style

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Straight style thermowells (1)
Straight style thermowells have the same diameter along the entire immersion length. They present the largest profile to the process medium and have the highest drag force compared to other styles with the same root diameter. Because of the large tip diameter, there is more mass to heat which slows the thermal response of the measurement assembly. The minimum immersion length (U) allowed with this profile is 1-in. (25 mm) except for parallel threaded thermowells that have a minimum immersion of 2-in. (50 mm).
Tapered style thermowells (2)
Tapered style thermowells have an outside diameter that decreases uniformly from root to tip. For the same root diameter, this design represents a good compromise between straight and stepped thermowells. It’s drag will be less than a straight style, but greater than a stepped style. The response time will be faster than a straight style and slower than a stepped style. The two general forms of a tapered stem are uniform (tapered from root to tip) and non-uniform (straight portion followed by tapered portion). Because of its profile shape, it is a good compromise for strength between the two other styles. It is the common choice for high velocity flow applications where the flow forces typically are too great to use a stepped well. The tapered design has faster response than the straight style offering an optimal balance of strength and response time factors. The minimum immersion length (U) allowed with this profile is 1-in. (25 mm) except for parallel threaded thermowells that have a minimum immersion of 2-in. (50 mm). The maximum length allowed for the tapered profile is; Immersion length (U) + Head length (H) <= 4-in. (1067 mm)
Stepped style thermowells (3)
Stepped style thermowells have two straight sections with the smaller diameter straight section at the tip. For the same root diameter as a straight profile thermowell, this design has less profile exposure to the flowing process and exhibits less drag force and quicker response time due to the smaller mass at the tip. In general, stepped thermowells will have thinner walls. By the geometry of its design, the stepped well has a higher natural frequency than the other styles with the same root diameter, and is less susceptible to vibration induced failure. Since this design has less material at the tip, its considered the best thermowell for fast time response. The minimum immersion length (U) allowed with this profile is 3-in. (75 mm) except for parallel threaded thermowells that have a minimum immersion of 4-in. (100 mm).
60
Emerson.com/Rosemount
Page 61
June 2019
Rosemount 114C

Thermowell material

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The material of construction is typically the first consideration in choosing a thermowell for any given application. Three factors affect the choice of material:
1. Chemical compatibility with the process media to which the thermowell will be exposed.
2. Temperature limits of the material
3. Compatibility with the process piping material to ensure solid, non-corroding welds and junctions.
It is important the thermowell conforms to the design specs of the pipe or vessel it will be inserted into to ensure structural and material compatibility. The original process design most likely included temperature, pressure, and corrosive considerations as well as cleaning procedures, agency approvals required, and conformance with codes or standards. Since an installed thermowell essentially becomes part of the process, these original design considerations also apply to the thermowell and will drive the thermowell material of construction and mounting type selection. International pressure vessel codes are explicit about the types of materials and methods of construction allowed.
Table 17. Thermowell Materials
Code Thermowell material Flange material Code Thermowell material Flange material
SC
316/316L SST dual rated (NORSOK)
(1)
SD
ASTM A479 NORSOK M-630 MDS D57
SF
SG
316/316L SST with Tantalum sheath
(2)
SH
SJ
SK
SL
SM
SN
SR
316/316L SST
UNS S31600/S31603
ASTM A479
UNS S31600/S31603
304/304L SST
UNS S30400/S30403
ASTM A479
316T i SST
UNS S31635
ASTM A479
UNS S31600/S31603
ASTM A479
316/316L SST w / PFA coating
UNS S31600/S31603
ASTM A479
304/304L SST with PTFE coating
UNS S30400/S30403
ASTM A479
310 SST
UNS S31008
ASTM A479
321 SST
UNS S32100
ASTM A479
321H SST
UNS S32109
ASTM A479
DIN 1.4
904L SST
UNS N08904
ASTM A479 DIN 1.4539
316/316L SST
UNS S31600/S31603
ASTM A182 or A240
(1)
316/316L SST dual rated (NORSOK)
UNS S31600/S31603
ASTM A182 NORSOK M-630 MDS D54
304/304L SST
UNS S30400/S30403
ASTM A182 or A240
316T i SST
UNS S31635
ASTM A182
316/316L SST with Tantalum sheath
UNS S31600/S31603
ASTM A182 or A240
Tantalum sheath UNS R05252 AF
316/ 316L SST w / PFA coating
UNS S31600/S31603
ASTM A182 or A240
304/304L SST with PTFE coating
UNS S30400/S30403
ASTM A182 or A240
310 SST
UNS S31008
ASTM A182 or A240
321 SST
UNS S32100
ASTM A182 or A240
321H SST
UNS S32109
ASTM A182 or A240
DN 1.4878
904L SST
UNS N08904
ASTMor A240
DIN 1.4539
AM
SP
AB
AC
AD
AE
AG
AH
AJ
AK
AL
347 SST
UNS S34700
ASTM A479 DIN 1.4550
Alloy B3
UNS N10001
ASTM B335
Alloy C-276
UNS N10276
ASTM B574
Alloy C-4
UNS N06455
ASTM B574
Alloy C-22
UNS N06022
ASTM B574
Alloy C-22
UNS N06022
ASTM B574
Alloy 20
UNS N08020
ASTM B473
Alloy 400
UNS N04400
ASTM B164
Alloy 400
UNS N04400
ASTM B164
Alloy 600
UNS N06600
ASTM B166
Alloy 600
UNS N06600
ASTM B166
Alloy 601
UNS N06601
ASTM B166 DIN 2.4851
347 SST
UNS S34700
ASTM A182 or A240
DIN 1.4550
Alloy B3
UNS N10001
ASTM B333
Alloy C-276
UNS N10276
ASTM B462 or B575
304/304L SST
UNS S30400/S30403
ASTM A182 or A240
304/304L SST
UNS S30400/S30403
ASTM A182 or A240
316/316L SST
UNS S31600/S31603
ASTM A182 or A240
Alloy 20
UNS N08020
ASTM B462 or B463
Alloy 400
UNS N04400
ASTM B564 or B127
304/304L SST
UNS S30400/S30403
ASTM A182 or A240
Alloy 600
UNS N06600
ASTM B564 or B168
304/304L SST
UNS S30400/S30403
ASTM A182 or A240
Alloy 601
UNS N06601
ASTM B168 or B564
DIN 2.4851
Emerson.com/Rosemount
61
Page 62
Rosemount 114C
June 2019
Table 17. Thermowell Materials
Code Thermowell material Flange material Code Thermowell material Flange material
AN
AP
AQ
AR
AU
AS
CS
TT
DS
Alloy 625
UNS N06625
ASTM B446 DIN 2.4856
Alloy 800
UNS N08800
ASTM B408 DIN 1.4876
Alloy 800H/HT
UNS N08811
ASTM B408 DIN 1.4959
Alloy 825
UNS N08825
ASTM B425 DIN 2.4858
Alloy C-22
UNS N06022
ASTM B574 DIN 2.4602
Alloy F44 Mo6
UNS S31254
ASTM A479 DIN 1.4547
Carbon steel UNS K03504
ASTM A105
Titanium grade 2
UNS R50400
ASTM B348 GR 2
Super duplex
UNS 32750
ASTM A479 GR F53
Alloy 625
UNS N06625
ASTM B443 or B564
DIN 2.4856
Alloy 800
UNS N08800
ASTM B409 or B564
DIN 1.4876
Alloy 800H/HT
UNS N08811
ASTM B409 or B564
DIN 1.4959
Alloy 825
UNS N08825
ASTM B424 or B564
DIN 2.4858
Alloy C-22
UNS N06022
ASTM B567 or B575
DIN 2.4602
Alloy F44 Mo6
UNS S31254
ASTM A182 or A240
DIN 1.4547
Carbon steel
ASTM A105, A216 GR WCB, or A515 GR
UNS K03504
70
Titanium grade 2
UNS R50400
ASTM B381 GR 2
Super duplex
UNS 32750
ASTM A182 GR F53 or A240
Duplex 2205
UNS 31803
ASTM A479 GR F51
Chrome-Moly Grade F-91
UNS K90901
ASTM A182
Nickel 200
UNS N02200
ASTM B160
Molybdenum
UNS R03600
ASTM B387
Chrome-Moly Grade B-11
UNS K11797
ASTM A739 GR B-11
Chrome-Moly Grade B-22
UNS K21390
ASTM A739 GR B-22
Super duplex (NORSOK)
UNS 32750
AS TM A 47 9 GR F53 NO RSO K
M-630 MDS D57
Duplex 2205 (NORSOK)
UNS 31803
AS TM A 47 9 GR F51 NO RSO K
M-630 MDS D47
Molybdenum
UNS R03600
ASTM B387
DIN 1.5415 EN 10273
DT
DV
DU
CC
NK
MD
CA
CB
MO
(1)
(1)
Duplex 2205
UNS 31803
ASTM A182 GR F51or A240
Chrome-Moly Grade F-91
ASTM A182 GR F-9, A217 GR C12A,
ASTM A182 GR F-11 CL2 or A387
ASTM A182 GR F-22 CL3, A217 GR
ASTM A182 GR F53 NORSOK M-630
ASTM A182 GR F51 NORSOK M-630
UNS K90901
or A387 GR 91 CL2
Nickel 200
UNS N02200
ASTM B162 or B564
Molybdenum
UNS R03630
ASTM A204 or B386
Chrome-Moly Grade F-11
UNS K11572
GR11 CL2
Chrome-Moly Grade F-22
UNS K21590
WC9, or A387 GR22 CL2
Duplex 2205 (NORSOK)
UNS 31803
MDS D54
Duplex 2205 (NORSOK)
UNS 31803
MDS D44
Molybdenum
UNS R03630
ASTM A204 or B386
DIN 1.5415 EN 10222-2
1. Material supplier qualified per NORSOK M-650; material qualified per NORSOK M-630.
2. Sheath thickness = 0.01-in. (0.38 mm).

NORSOK

Rosemount 114 Thermowell ordered with NORSOK will have raw material from a NORSOK M-650 approved supplier, material approver per NORSOK M-630 datasheet, and flange welding qualified to NORSOK M-601. The NORSOK material will also meet requirements of NACE MR0175/ISO 15156.
Q8 should be ordered to receive the MTR. The MTR will come with an M-650 Qualification Test Record (QTR) cover sheet. Additional testing required by the M-630 datasheet will be included in the MTR.
Some of the required testing for NORSOK Duplex in addition to ASTM requirements;
Micrographic examination at 400 to 500 magnification
Ferrite content analysis according to ASTM E 562 or by image analysis according to ASTM E 1245. Ferrite content shall be within
35–55 percent.
Charpy V-notch testing according to ASTM A 370 at –46 °C. Minimum absorbed energy shall be 45 J average and 35 J single.
Corrosion testing according to ASTM G 48 Method A. No pitting at 20 magnification; Weight loss shall be less than
2
.
4 g/m
Full details of the material requirements can be found in the ASTM and NORSOK M-630 standards.
62
Emerson.com/Rosemount
Page 63
June 2019
H
Rosemount 114C

Head length (H)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Head length is the distance from the bottom of the process connection to the top of the thermowell. Each style has a minimum head length; the length specified must meet or exceed that minimum. It is shown below for all process connection styles.
Note
The industry standard minimum head length for flanged and Van Stone thermowells with connections under Class 900 (ASME B16.5) or PN 100 (EN 1092-1) is 2.25-in. (60 mm).
Table 18. Recommended Minimum Head Length
Process connection
Threaded
Welded
1. Dimensions are in inches (millimeters).
Minimum head length (H)
1.75 (45)
Table 19. Recommended Minimum Head Length by Connection Class for ASME B16.5
Connection size
(1)
(1)
Connection class
Flanged 150 300 400/600 900/1500 2500
3
/4 N/A 1.75 (45) N/A N/A N/A
1 1.75 (45) 2.00 (50) 2.00 (50) 2.50 (65) N/A
1
1
/2 1.75 (45) 2.00 (50) 2.00 (50) 2.50 (65) 3.00 (75)
2 1.75 (45) 2.00 (50) 2.00 (50) 2.75 (70) 3.25 (80)
3 2.00 (50) N/A N/A N/A N/A
4 2.00 (50) N/A N/A N/A N/A
6 2.00 (50) N/A N/A N/A N/A
Flanged with RTJ 150 300 400/600 900/1500 2500
3
/4 N/A 2.00 (50) N/A N/A N/A
1 1.75 (45) 2.00 (50) 2.00 (50) 2.50 (65) N/A
1
1
/2 2.00 (50) 2.00 (50) 2.00 (50) 2.50 (65) 3.25 (80)
2 2.00 (50) 2.00 (50) 2.00 (50) 2.75 (70) 350 (85)
3 2.25 (60) N/A N/A N/A N/A
4 2.25 (60) N/A N/A N/A N/A
6 2.25 (60) N/A N/A N/A N/A
Emerson.com/Rosemount
63
Page 64
Rosemount 114C
June 2019
Table 19. Recommended Minimum Head Length by Connection Class for ASME B16.5
Connection size
Connection class
(1)
Van Stone 150 300 400/600 900/1500 2500
1 1.75 (45) 1.75 (45) 1.75 (45) 2.00 (50) 2.25 (60)
1
1
/2 1.75 (45) 1.75 (45) 1.75 (45) 2.25 (60) 2.75 (70)
2 1.75 (45) 1.75 (45) 2.00 (50) 2.75 (70) 3.25 (80)
Van Stone with RTJ 150 300 400/600 900/1500 2500
1 1.75 (45) 1.75 (45) 2.25 (60) 2.25 (60) 2.50 (65)
1
1
/2 1.75 (45) 2.00 (50) 2.00 (50) 2.50 (65) 3.00 (75)
2 1.75 (45) 2.00 (50) 2.25 (60) 3.00 (75) 3.50 (90)
1. Dimensions are in inches (millimeters).
Table 20. Recommended Minimum Head Length by Connection Class for EN 1092-1
Connection size
Connection class
(1)
Flanged PN 2.5/6 PN 10/16 PN 25/40 PN 63 PN 100
DN 20 40 45 50
DN 25 40 45 50
DN 40 40 45 50
DN 50 40 45 55 60
DN 65 40 45 50 55 60
DN 80 40 45 50 55 60
DN 100 40 45 50 55 60
1. Dimensions are in millimeters.

Instrument connection

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Thread Specification Internal thread
1
/2–14 NPT SAE-AS 71082
1
/2–14 NPSM ASME B1.20.1, 8 threads minimum
3
/4–14 NPT SAE-AS 71082
M18 1.5p
M20 1.5p
M24 1.5p
M27 2p
M14 1.5p
1
G
/2-in. (BSPF) ISO 228/1 (BS 2779)
G3/4-in. (BSPF) ISO 228/1 (BS 2779)
BS 3643
64
Emerson.com/Rosemount
Page 65
June 2019
Rosemount 114C

Sensor/thermowell assemble to options (XT, XW)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
XT
This option is selected when a Rosemount 214C Sensor is ordered with the Rosemount 114C Thermowell. This ensures the sensor is threaded into the thermowell, but only hand tightened.
XW
This option is selected when a Rosemount 214C Sensor is ordered with the Rosemount 114C Thermowell. This ensures the sensor is threaded into the thermowell and torqued for a process-ready installation.

Extended product warranty (WR3, WR5)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The extended product warranty options are available in three or five year coverage plans. In the model string, order option codes WR3 for a three year extended warranty or WR5 for a five year warranty. This coverage is an extension of the manufacturer's limited warranty and states that the goods manufactured or services provided by seller will be free from defects in materials or workmanship under normal use and care until the expiration of the applicable warranty period.

Thermowell calculation (R21)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The ASME PTC 19.3TW is internationally recognized as a mechanical design standard yielding reliable thermowell service in a wide range of temperature measurement applications. It includes evaluation of stresses applied to a barstock thermowell as installed in a process based on the design, material, mounting method, and process conditions. The documentation provided will detail the process information, thermowell geometry, and comprehensive calculation analysis. It will also provide an acceptable or unacceptable statement based on the analysis.
There are four quantitative criteria in ASME PTC 19.3 TW for a thermowell to be found acceptable for a particular set of process conditions:
Frequency Limit: the resonant frequency of the thermowell must be sufficiently high so that destructive oscillations are not
excited by the fluid flow.
Dynamic Stress Limit: the maximum primary dynamic stress must not exceed the allowable fatigue stress limit. If the design
requires that the thermowell pass through the in-line resonance to get to the operating conditions, there is an additional fatigue check at resonance.
Static Stress Limit: the maximum steady-state stress on the thermowell must not exceed the allowable stress, as determined by
the Von Mises criteria.
Hydrostatic Pressure Limit: the external pressure must not exceed the pressure ratings of the thermowell tip, shank, and flange
(or threads).
Emerson.com/Rosemount
65
Page 66
Rosemount 114C
In addition, the suitability of the thermowell material for the process environment must be considered. This means the designer must evaluate how corrosion and erosion affects the thermowell as well as how exposure to the process conditions affects material properties.
June 2019
For detailed information about this standard, refer to the Thermowell Calculations White Paper should have a wake frequency calculation performed to ensure they are suitable for the process conditions in their application. Emerson assumes that the customer has either done their own calculations or understands the risks of not having calculations done if this option is not requested.
. Emerson advises that all thermowells

NACE certification (Q35)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
This option certifies that thermowell materials used are compliant to NACE MR0175/ISO 15156 and NACE MR0103. The material certification provided will list compliance to the referenced standard.
Material code
SC 316/316L Dual Rated
SF 304/304L Dual Rated
SL 310 SST
SM 321 SST
SN 321H SST
SP 347 SST
SR 904L SST
AB Alloy B3
AC Alloy C-276
AG Alloy 20
AH Alloy 400
NACE certified material
Material code
AK Alloy 600
AM Alloy 601
AN Alloy 625
AR Alloy 800
AQ Alloy 800H/HT
AR Alloy 825
AS Alloy F44 Mo6
AU Alloy C-22
CA Chrome-Moly Grade B-11/F-11 Class II
CB Chrome-Moly Grade B-22/ F-22 Class III
NACE certified material

PMI testing (Q76)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Positive Material Identification (PMI) is a test that verifies the thermowell material is as specified by the Rosemount 114C model code. X-ray/radiograph fluorescence (XRF) is used to provide elemental analysis in a nondestructive manner. The certificate will provide PMI results in comparison with the applicable material standards for each individual thermowell and state the reference standard. Two points are provided on flanges. All other thermowell components (including welds) will have a single point. XRF will not detect carbon in steels. PM I can be marke d on the thermowell by choosing option R40. Due to type of technology used carbon steel material is exempt from this testing.
66
Emerson.com/Rosemount
Page 67
June 2019
Rosemount 114C

Material certification (Q8)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Material certificate and traceability in accordance with EN 10204 Type 3.1 Inspection Certificate. The certificate provided will document the heat code, chemical analysis, and testing required by material standards.

Low temperature Charpy test (M01)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Test is performed in accordance with ASTM A370 and report will be include in the Material Traceability Report (Q8). This report must be ordered if any documentation is required. Charpy test will be done to check toughness of the raw bar and flange material used for the construction of the thermowell. The table below shows the material available with the option, test temperature, and acceptance criteria.
Material Material codes
Charpy temperature Acceptance impact value
DS – Super duplex
Duplex
DT – Super duplex (NORSOK) DU – Duplex
–58 °F (–50 °C)
Average: 45 J (33 ft-lb)
Minimum: 35 J (26 ft-lb)
DV – Duplex (NORSOK)
SC – 316/316L SST SD – 316/316L SST (NORSOK) SF – 304/304L
300 Series SST
SG – 316 Ti SH – 316/316L with tantalum sheath
–321 °F (–196 °C)
Average: 60 J (44 ft-lb)
Minimum: 55 J (41 ft-lb) SJ – 316/316L with PFA coating SK – 304/304L with PTFE coating SM – 321 SST
When ordering this option with any weld documentation (Q66-Q68), note that there is a separate set of documents needed to meet the test requirements. There are Q66-68 weld documents specifically for M01 tested material.

Ultrasonic material test (M02)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Ultrasonic examination will be done to check quality of the raw bar and flange material used for thermowell construction. The testing shall be performed in accordance with procedures specified in ASTM A388 by a Level 2 inspector. Calibration and acceptance criteria shall be per API 6A.
Emerson.com/Rosemount
67
Page 68
Rosemount 114C
μ
June 2019

Surface finish certification (Q16)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Thermowell surface finish is typically done to remove all the burrs and sharp edges which smooths the thermowell stem surface. The Rosemount 114C comes with a standard surface finish of T32 in. CLA N6 (0.8 μm Ra) or better. This option provides a certificate that documents the maximum surface finish reading for stem and flange (when applicable) and a pass/fail statement. Improved surface finish options are also available for the Rosemount 114C (see options R14 and R20).
Surface finish <Ra 0.3 μm (12 μin) (R14)
Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Improves surface finish to be less than Ra 0.3 μm. An improved surface finish will increase corrosion resistance and make the thermowell easier to clean. This is common in sanitary applications.

Electropolish (R20)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The electropolish process uses a combination of electrical current and chemicals to improve the surface finish. The surface will appear shiny and polished. It can have an advantage over mechanical polishing because there is no cold work involved that can lead to scratches, strains, metal debris, and embedded abrasives on the surface. An improved surface finish will increase corrosion resistance and make the thermowell easier to clean. This is common in sanitary applications.

Stepped instrument threads (R61)

Back to Van Stone ordering table
Threads are recessed and begin 0.35-in. (9 mm) from the top of the face of the thermowell's instrument connection entry as shown below:

Standard external hydrostatic pressure test (Q5)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Thermowells are tested at room temperature for 10 minutes. Water is certified to have a chlorine content of less than 30 ppm. The certificate will document the chlorine content, hydrostatic test pressure level, duration, and test results. The pressure rating (in psi) for the different thermowell mounting styles is given below.
68
Emerson.com/Rosemount
Page 69
June 2019
Rosemount 114C
Flanged and Van Stone
Hydrostatic pressure test levels are in accordance with ASME B16.5. When the table below and the standard conflict, the standard shall govern.
Thermowell material (psi)
Flange class (lb)
150 300 350 425 450 450 450
300 725 900 1100 1125 1125 1125
600 1450 1800 2175 2225 2250 2250
1500 (900) 3600 4500 5400 5575 5600 5625
2500 6000 7500 9000 9275 9300 9375
AH, AQ, TTSC, SD, SF, SG, SH, SJ, SK, SL, SM,
NK
SN, SP, AP, AM, AD, AE, AF, AJ, AL
CS SR
AG, AK, CA, AB, AC, CB, CC, DU, DT, DV, AN, AR,
DIN flanged thermowells
Table 21. External Pressure Test–DIN
DIN flanged thermowells
Nominal pressure (bar) Test pressure (bar)
16 40
40 100
100 250
Tes t to 2.5 nominal pressure rating
Threaded thermowells
1500 psi
AU, AS, MO, DS

Extended external hydrostatic pressure test (Q9)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Thermowells are tested at room temperature for 20 minutes. Water is certified to have a chlorine content of less than 30 ppm. The certificate will document the chlorine content, hydrostatic test pressure level, duration, and test results. The pressure rating (in psi) for the different thermowell mounting styles are the same as the standard external pressure test.

Standard internal hydrostatic pressure test (Q85)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
This test is performed at room temperature for a minimum of 10 minutes to 3000 PSI. The water used here is certified to ensure a chloride content of less than 30 PPM. The certificate provided will document the chloride content, hydrostatic test level, duration, and results. Thermowells longer than 42-in. will be required to have an internal pressure test (Q85) performed to ensure the internal cavity integrity has not been compromised.
Emerson.com/Rosemount
69
Page 70
Rosemount 114C
June 2019

Extended internal hydrostatic pressure test (Q86)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
This test is performed at room temperature for a minimum of 20 minutes to 3000 PSI. The water used here is certified to ensure a chloride content of less than 30 PPM. The certificate provided will document the chloride content, hydrostatic test level, duration, and results. Thermowells longer than 42-in. will be required to have an standard internal pressure test (Q85) performed to ensure the internal cavity integrity has not been compromised.

Canadian registration number (Q17)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Any pressure vessel, piping system, or fitting used in Canada is required by law to have a CRN (Canadian Registration Number). This ensures all pressure vessels, piping systems, and fittings are built under appropriate quality control programs. This CRN is for all Canadian provinces but the end destination province still needs to be known during the order process.
Material code
SC 316/316L Dual Rated AK Alloy 600
SF 304/304L Dual Rated AL Alloy 600 (with 304 SST Flange)
SH 316 SST with Tantalum Sheath AM Alloy C-22
SJ 316L SST with PFA Coating AN Alloy 625
SK 304 SST with PTFE Coating AP Alloy 800
SL 310 SST AQ Alloy 800H/HT
SM 321 SST AR Alloy 825
SN 321H SST CA Chrome-Moly Grade B-11/F-11 Class II
SP 347 SST CB Chrome-Moly Grade B-22/F-22 Class III
AB Alloy B3 CC Chrome-Moly Grade F-91
AC Alloy C-276 CS Carbon Steel (A-105)
AG Alloy 20 TT Titanium Grade 2
AH Alloy 400 DU Duplex 2205 Grade F51
AJ Alloy 400 (with 304 SST Flange)
CRN approved material
Material code
CRN approved material

Dye penetration test (Q73)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Dye or liquid penetration testings are performed by ASME Level II or III trained inspectors. These tests are all done in accordance to ASME Section V, Article 6 with an acceptance criteria per ASME Section III, Div 1 NB-2546. The certificate will document the inspectors name, dye penetration acceptance criteria, and test result.
70
Emerson.com/Rosemount
Page 71
June 2019
Rosemount 114C

Wall thickness test (Q83)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Ultrasonic examination performed to check stem wall thickness. Min and max wall thickness measurements shall be recorded 25 mm or 1-in. from the thermowell tip. Bore position should be 10 percent of minimum stem wall thickness at nominal dimensions (see image below).

Special cleaning (Q6)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Special cleaning for oxygen/special service to be performed in accordance to ASTM G93. The procedure to be qualified using ASTM G93 Type II quantitative tests. The documentation provided for this test will have a compliance statement to ASTM G93. All cleaned thermowells will come in a sealed plastic bag to prevent contamination. Not available with carbon steel or any coated material.

Thermowell markings (R40)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
This options provides the ability to have certain test markings on the thermowell. Below are the tests available for this option.
Q5 — Standard external pressure tests the values and units
Q76 — PMI will be marked on the head length portion of the thermowell and on the top of the flange if applicable
Q9 — Extended external pressure test values and units
Q85 — Standard internal pressure tests values and units
Q86 — Extended internal pressure tests values and units
Emerson.com/Rosemount
71
Page 72
Rosemount 114C
MAX = t+ 3.5 MIN = t
June 2019

Welding procedure qualification record (Q66)

Back to Flanged ordering table
A record of a test performed and tested to ensure that the procedure will produce a good weld. Documentation to be supplied in accordance with QW-200.2 ASME Section IX.
The records for thermowells with option M01 (low temperature charpy) are different and are highlighted when choosing to ensure the right documents are submitted to the customer.

Welder performance qualifications (Q67)

Back to Flanged ordering table
A test certificate that shows whether a welder possesses the necessary experience and knowledge to perform the specifications of a particular weld procedure. Documentation to be supplied in accordance with QW-301.4 ASME Section IX.

Welding procedure specification (Q68)

Back to Flanged ordering table
A formal written document that describes and provides direction to a welder or welding operator for making sound and quality production welds per code requirements. Documentation to be supplied in accordance with Article V, ASME Section IX.

Phased array ultrasonic test (Q80)

Back to Flanged ordering table
This test is only available on the full penetration weld flanged thermowells. Testing shall be performed in accordance with ASME section V article 4. Inspection criteria shall be per ASME Section VIII Div 1 per UW3 and conducted by a Level 2 Inspector. The certificate provided with this option will document the results and the inspectors acceptance criteria .

X-ray/radiograph test (Q81)

Back to Flanged ordering table
Weld joints to be examined for any internal imperfections. Available only with full penetration flanged thermowells. test shall be performed according with ASME section V, article 24. Inspection criteria shall be per ASME section VIII, Div 1 per UW-51 by a level 2 inspector. Supplier to x-ray report for 10 years. Certificate shall include inspector, acceptance criteria and results. Marking made during test shall be removed.

Spherical tip (R60)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Radius of spherical tip (B) is the same as the specified thermowell tip radius. Thermowell will still maintain specified “U” length.
72
Emerson.com/Rosemount
Page 73
June 2019
Rosemount 114C

Stainless steel plug and chain (R06)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The plug and chain are made from stainless steel. This plug is used to protect the thermowell threads when a sensor isn't installed. It also keeps elements such as rain, dust, and dirt out of the thermowell.

Brass plug and chain (R23)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The plug and chain are made from brass. This plug is used to protect the thermowell threads when a sensor isn't installed. It also keeps elements such as rain, dust, and dirt out of the thermowell.

Vent hole (R11)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
The vent hole allows for the venting of a thermowell. Vent or weep holes are often used to prevent gas buildup in certain applications. This option is useful in applications where gas build up is a concern. Process fluid leakage from the vent hole is an indicator of thermowell failure.
Emerson.com/Rosemount
73
Page 74
Rosemount 114C
A
B
C
D
E
June 2019

Flange face – concentric serrations (R09)

Back to Flanged ordering table
Back to Van Stone ordering table
This option changes the flange face so it has concentric serrations covering the wetted portion of the flange raised face. It is installed with an inside bolt circle (IBC) gasket/ring gasket, which extends to and is centered by the bolts. This flange face is designed per the ASME B16.5 standard.
Figure 25. Installation Components
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process

Flange face – flat (R10)

Back to Flanged ordering table
This option changes the flange face so it has no raised section on the wetted portion of the flange face. The flat face is finished with spiral serrations. This style is frequently used where the mating flange is made from a casting or fragile material. It can be installed with ring gaskets or full face gaskets that extend past the bolt holes. This flange face is designed per the ASME B16.5 standard.
74
Emerson.com/Rosemount
Page 75
June 2019
A B
C
D
E
A B
C
D
E
Figure 26. Installation Components
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process

Raised face – Type B2 (R15)

Rosemount 114C
Back to Flanged ordering table
This option provides a smoother finish to the flange face compared to the standard Type B1 flange face.
Figure 27. Installation Components
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process
Emerson.com/Rosemount
75
Page 76
Rosemount 114C
A B
C
D
E
June 2019

Flange face – RTJ (R16)

Back to Flanged ordering table
Back to Van Stone ordering table
This option changes the flange face so it has a ring type joint (RTJ). The RTJ flange face is common for high pressure applications using Class 600 flanges or higher. Both mating flanges have grooves that can accept a RTJ gasket which is usually made of solid metal. This flange face is designed per the ASME B16.5 standard.
Figure 28. Installation Components
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process

Flange face – groove, Type D (R18)

Back to Flanged ordering table
Back to Van Stone ordering table
Type C “tongue” will mount to Type D “groove”.
76
Emerson.com/Rosemount
Page 77
June 2019
Figure 29. Installation Components
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process

Flange face – tongue, Type C (R19)

Rosemount 114C
Back to Flanged ordering table
Back to Van Stone ordering table
Type C “tongue” will mount to Type D “groove”.
Figure 30. Installation Components
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process
Emerson.com/Rosemount
77
Page 78
Rosemount 114C

Flange face – spigot, Type E (R24)

Back to Flanged ordering table
Back to Van Stone ordering table
Type E “spigot” will mount to type F “recess”.
Figure 31. Installation Components
June 2019
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process

Flange face – recess, Type F (R25)

Back to Flanged ordering table
Back to Van Stone ordering table
Type E “spigot” will mount to type F “recess”.
78
Emerson.com/Rosemount
Page 79
June 2019
Figure 32. Installation Components
A. Thermowell B. Bolt/washers C. Ring gasket D. Nozzle and mating flange E. Process

Thermowells with wrench flats (R37)

Rosemount 114C
Back to Threaded ordering table
This option only applies to threaded thermowells made from exotic materials. By default, these thermowells are made with two wrench flats; this option must be selected to get hex (6) wrench flats.
Figure 33. Wrench Flats
Standard Option R37
Emerson.com/Rosemount
79
Page 80
Rosemount 114C
A
June 2019
Table 22. Exotic Materials
Code Material Code Material Code Material
AB Alloy B3 AL
with 304/304L SST flange)
Alloy 600
CA
AC Alloy C-276 AU Alloy C-22 CB
AD
AE
AF
(with 304/304L SST flange)
(with 304/304L SST flange)
(with 316/316L SST flange)
Alloy C-4
Alloy C-22
Alloy C-22
AM Alloy 601 CC Chrome-Moly Grade F-91
AN Alloy 625 NK Nickel 200
AP Alloy 800 TT Titanium Grade 2
AG Alloy 20 AQ Alloy800H/HT DS Super duplex SST Grade F-53
AH Alloy 400 AR Ally 825 DT
AJ
(with3 04/304L SST flange)
Alloy 400
AS Alloy F44 Mo6 DU Duplex 2205 Grade F-51
AK Alloy 600 MO Molybdenum DV Duplex 2205 Grade F-51 (NORSOK)
Chrome-Moly Grade B-11/F-11
Class II
Chrome-Moly Grade B-22/ F-22
Class III
Super duplex SST Grade F-53
(NORSOK)

Root diameter (A0XX)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Larger root diameters will provide greater strength. Changing the root diameter is helpful when designing a thermowell to pass wake frequency calculations.
Guidelines on specifying design modifiers based on the stem profile are as follows:
Straight – only root diameter (Axxx) should be specified
Tapered – both root (Axxx) and tip diameter (Bxxx) must be specified
Stepped – if root diameter (Axxx) only is specified, the tip will be standard 0.5-in diameter; if tip diameter (Bxxx) is ordered, root
diameter (Axxx) must also be specified
80
Emerson.com/Rosemount
Page 81
June 2019
B
Rosemount 114C

Tip diameter (B0XX)

Table 23. Sample Root Diameters
Code Dimension (E) Code Dimension (M)
A040 0.4-in. A100 10 mm
A045 0.45-in. A110 11 mm
A100 1.00-in. A205 20.5 mm
A310 3.10-in. A790 79 mm
A315 3.15-in. A800 80 mm
Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Smaller tip diameters will improve time response. Changing the tip diameter is helpful when designing a thermowell to pass wake frequency calculations.
Guidelines on specifying design modifiers based on the stem profile are as follows:
Straight – only root diameter (Axxx) should be specified
Tapered – both root (Axxx) and tip diameter (Bxxx) must be specified
Stepped – if root diameter (Axxx) only is specified, the tip will be standard 0.5-in. diameter; if tip diameter (Bxxx) is ordered, root
diameter (Axxx) must also be specified
Table 24. Sample Tip Diameters
Code Dimension (E) Code Dimension (M)
B040 0.4-in. B120 12 mm
B045 0.45-in. B130 13 mm
B100 1.00-in. B205 20.5 mm
B175 1.75-in. B450 45 mm
B180 1.80-in. B460 46 mm
Emerson.com/Rosemount
81
Page 82
Rosemount 114C
d
June 2019

Bore diameter (d0X)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Bore diameter (d) can be selected to accommodate different temperature sensor sizes. Time response is improved when the sensor and thermowells have a tighter fit.
Table 25. Available Bore Diameters
Code Dimension Code Dimension (M)
D01 0.276-in./7.0 mm D05 0.354-in./9 mm
D03 0.138-in./3.5 mm D06 0.433-in./11 mm
D04 0.385-in./9.8 mm

Tip thickness (t0X)

Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table
Tip thickness (t) is specified as the minimum thickness and measured from the top of the gun drill web as shown in the figure below
t
Table 26. Available Tip Thicknesses
Code Dimension
T01 0.197-in./5.0 mm
T02 0.236-in./6.0 mm
82
Emerson.com/Rosemount
Page 83
June 2019
f
e
e

Van Stone stub thickness (F0X)

Back to Van Stone ordering table
Van Stone stub thickness is the thickness of the surface on which the flange lies as shown in the figure below.
Table 27. Available Stub Thicknesses
Code Dimension
F01 0.591-in. (15 mm)
F02 0.787-in. (20 mm)

Fillet radius (E0X)

Rosemount 114C
Back to Flanged ordering table
Back to Van Stone ordering table
Lap Joint flanges are machined with a flat face and a fillet radius to accommodate the stub end or pipe lap as shown in image below.
Table 28. Available Fillet Radius
Code Dimension
E01 0.118-in. (3.0 mm)
E02 0.197-in. (5.0 mm)
Emerson.com/Rosemount
83
Page 84
Rosemount 114C
June 2019

Lap flange material for Van Stone design (C0X)

Back to Van Stone ordering table
This option is only available when the Van Stone (V) mounting configuration is selected. By default, a Van Stone thermowell comes with a carbon steel A105 lap flange. These options give the choice of having the thermowell ordered without a flange, with a 316/316LSST flange, or with a flange of similar material as the thermowell stem. Below are some model string examples of the standard offering and options for reference:
Example model: 114CE0030VAA2SC032A – carbon steel A105 lap flange with 316/316L SST thermowell stem provided (standard)
Example model: 114CE0030VAA2SC032AC01 – no lap flange, only thermowell stem provided
Example model: 114CE0030VAA2SC032AC02 – changes default carbon steel A105 lap cover flange to 316/316LSST flange
Example model: 114CE0030VAA2SC032AC03 – changes default cover flange to match thermowell stem material
Note
Coatings do not apply to lap flange.
84
Emerson.com/Rosemount
Page 85
June 2019
Rosemount 114C
Emerson.com/Rosemount
85
Page 86
Rosemount 114C
00813-0200-4952, Rev EB
Global Headquarters
Emerson Automation Solutions
6021 Innovation Blvd. Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@Emerson.com
North America Regional Office
Emerson Automation Solutions
8200 Market Blvd. Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.com
Latin America Regional Office
Emerson Automation Solutions
1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA
+1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@Emerson.com
Product Data Sheet
June 2019
Europe Regional Office
Emerson Automation Solutions Europe GmbH
Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland
+41 (0) 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@Emerson.com
Asia Pacific Regional Office
Emerson Automation Solutions
1 Pandan Crescent Singapore 128461
+65 6777 8211 +65 6777 0947 Enquiries@AP.Emerson.com
Middle East and Africa Regional Office
Emerson Automation Solutions
Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
+971 4 8118100 +971 4 8865465 RFQ.RMTMEA@Emerson.com
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
Google.com/+RosemountMeasurement
Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies.
All other marks are the property of their respective owners.
© 2019 Emerson. All rights reserved.
Loading...