The purpose of this guide is to assist you in correctly operating your InTENSity™ Micro Combo unit. This
device should only be used under the continued supervision of a healthcare professional. This guide is
not intended to replace or substitute the InTENSity™ Micro Combo Instruction Manual. PLEASE READ THE INSTRUCTION MANUAL COMPLETELY BEFORE USING THIS DEVICE. Read, understand and practice
the contraindications, warnings, cautions and operating instructions found on pages 7 – 12 on your
instruction manual. Always follow the operating instructions prescribed by your healthcare provider.
12
Top
5
3
4
10
FrontBack
INTENSITY
™
MICRO COMBO UNIT
Channel 1 output socket
1
Channel 2 output socket
2
Channel 1 intensity increase button
3
Channel 1 intensity decrease button
4
Mode (M) selection button
5
LCD display
6
6
7
8
9
11
12
13
Parameter (S) selection button
7
Channel 2 intensity increase button
8
Channel 2 intensity decrease button
9
Power on/o button
10
Belt clip
11
Battery compartment cover
12
13
AC/DC adapter receptacle
InTENSity™ MICRO COMBO
replacement parts:
WW3005 – lead wires
EIF1515TC2 – electrodes
ELECTRODES
SET OF 4
LEAD WIRES
2 SETS
For more information about your InTENSity™ Micro Combo unit, please visit roscoemedical.com or call 1-800-871-7858.
DEFINITIONS
TENS
Transcutaneous
Electrical
Nerve Stimulator
MIC
Microcurrent
Do not use this
device for
undiagnosed pain
syndromes until
consulting
a physician.
INDICATION FOR USE
The TENS and MIC modes are often prescribed for:
• Symptomatic relief of chronic pain
• Post traumatic pain
• Post surgical pain
TENS is a non-invasive, drug-free method of controlling pain
that uses tiny electrical impulses sent to the nerves to modify
your perception of pain. TENS does not cure any physiological
problem; it only helps control pain.
MIC stimulation consists of a very low current sent into the
cells of the body. The current is so faint it is measured in
millionths of an amp (or microamps) and is often not felt by
the user. MIC increases energy production in cells of your body
and increases tissue healing rates.
Steps 1 – 4 should be performed with the
device turned OFF. Once the unit has been
turned ON, do not remove electrodes
IMPORTANT!
without rst turning OFF the device.
QUICK REFERENCE GUIDE PAGE 2
INSERT BATTERY
1
Press arrow and slide battery compartment
cover open. Insert 9V battery, matching the
+ and – ends to those in unit.
PLACE ELECTRODES
4
ON SKIN
Remove electrodes from
protective backing. Keep
backing to properly store
electrodes after use.
Apply electrodes to the
exact site indicated by
your doctor or therapist.
Skin at the application site
should be clean and dry.
See Electrode Placement Guide for more information.
CONNECT ELECTRODES
2
TO LEAD WIRES
Firmly insert
the end of
the lead wire
pin into the
electrode
connectors.
Make sure no bare metal of the pins are exposed.
TURN DEVICE ON
5
Check that electrodes are securely placed on
the skin before activating device. Press and release the
button in the center of the unit to turn it ON.
CONNECT LEAD WIRES
3
TO TOP OF DEVICE
TOP VIEW
This unit operates with
one or two sets of
electrodes. When using
one set, plug lead wire
into Channel 1 on top of
the unit. Use Channel 2
to operate a second set.
Both channels may be
used to stimulate two
dierent areas at the
same time.
SELECT THE
6
THERAPEUTIC MODE
There are 2 therapeutic modes available: TENS and
MIC (microcurrent). Press the M button and continue
to press until you have advanced to your desired
therapeutic mode.
Consult your physician for your suitable
therapeutic mode.
TENS SETTING
Press the S button to enter and cycle through
to each setting state.
1
SET THERAPEUTIC PROGRAM
There are 4 programs available in the TENS therapeutic mode: B - Burst, N - Normal,
M - Pulse Width Modulation, and M1- Pulse Rate Modulation. The therapeutic
program can be selected by pressing the s and t buttons.
2
SET CYCLE TIME (OPTIONAL)
Cycle time is adjustable from 5 to 30 seconds. Only modulation has this parameter
setting. Press S button to enter this menu, and then press the s and t buttons to
adjusting the setting.
SET TIMER
3
Press the S button to enter this setting. The treatment time is adjustable from
1 to 60 minutes or Continuous. Press the s and t buttons to adjust setting. You
can set the timer to “Continuous” mode by pressing the s control when it shows
60 minutes. The output will be shut o when time is up. If in continuous mode, you
need to manually turn o device.
4
SET PULSE WIDTH
Pulse Width is adjustable from 50 uS to 300 uS. Press S button to enter this menu,
then press the s and t buttons to adjust the setting.
1
3
4
5
SET PULSE RATE
Pulse rate is adjustable from 1 Hz to 150 Hz (0.5 Hz to 5 Hz for Burst). Press the
S button after scrolling through and completing all settings to start the therapy
program. The s and t buttons can be used to increase s or decrease t the
intensity level.
3
5
QUICK REFERENCE GUIDE PAGE 3
MICROCURRENT SETTING
Press the S button to enter and cycle through to each
setting state.
1
SET THERAPEUTIC PROGRAM
There are 3 programs available in MIC therapeutic mode: N - Constant, M - Pulse
Width Modulation, and M1 - Pulse Rate Modulation. The therapeutic program can be
selected by pressing the s and t buttons. The mode you selected will show up on
the top of liquid crystal display.
2
SET TIMER
Press the S button to enter this setting. The treatment time is adjustable from
1 to 60 minutes or Continuous. Press the s and t buttons to adjust setting.
You can set the timer to “Continuous” mode by pressing the s control when it shows
60 minutes. The output will be shut o when time is up. If in continuous mode, you
need to manually turn o device.
3
SET PULSE WIDTH
Pulse width is adjustable from 2 ms to 200 ms. Press the S button to enter this
menu, and then press the s and t buttons to adjusting the setting.
4
SET PULSE RATE
Pulse rate is adjustable from 0.1 Hz to 150 Hz. Press the S button to enter this
menu, and then press the s and t buttons to adjusting the setting.
SET CYCLE TIMER
5
Cycle time is adjustable from 5 to 30 seconds. Only modulation mode has
the parameter setting. Press the S button to enter this menu, and then press the
s and t buttons to adjusting the setting.
1
2
2
3
5
4
IMPORTANT TIPS AND SAFETY FEATURES
Adjust intensity by pressing the intensity
control s and t buttons. Slowly press the
appropriate intensity button control until
you reach the setting recommended by your
physician or therapist. Repeat for the other
channel, if both channels are to be used.
If the stimulation levels are or become
uncomfortable, reduce the stimulation
intensity to a comfortable level and
contact your medical practitioner if
problems persist.
In the TENS therapeutic mode, if the electrodes are not placed rmly on the skin or the
device is not connected to the electrodes, the stimulator’s output surpasses 12mA and
will cancel out by automatically resetting to 0mA.
PROBLEMS WITH YOUR DEVICE? Please see pages 31 of your InTENSity™ Micro Combo Instruction Manual for troubleshooting tips.
The Safety Lock Feature automatically activates after there is no operation in
the panel for 30 seconds by locking out the ability to press the buttons. This is a safety
feature to prevent accidental changes to your settings and to prevent accidental
increases to the intensity levels. You can press either one of the t buttons to unlock
the device.
Once you have activated the treatment timer, you can press the M button or the
t button to control stop the treatment.
Turn o the device by pressing and holding the power on/o button for
3 seconds. If in “lock” mode, press the t button to unlock the device and then press
and hold the power on/o button for 3 seconds to turn o.
The device will automatically power o after 2 minutes of inactivity in the panel.
Low battery indicator signals when battery is low. Replace battery when
stimulation feels weaker.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.