Ropox Hudson 40-25023, Hudson 40-25026, Hudson 40-25029 User Manual, Mounting Instruction

Hudson, shower bed
User Manual
Mounting instruction
Keep this folder with the product at all times
Page 2
Content
Content .................................................................................................................................................. 2
Product information ............................................................................................................................................... 3
Part Numbers ......................................................................................................................................................... 3
Technical data ........................................................................................................................................................ 4
Daily use ................................................................................................................................................................. 4
The slat ................................................................................................................................................................... 4
After use................................................................................................................................................................. 5
Recommendations in use ....................................................................................................................................... 6
Important info before mounting ............................................................................................................................ 7
Placement of the Main 230 V socket, the hot and cold Water and the Drain: ......................................................... 7
Mounting Instructions ............................................................................................................................................ 8
Receiving the Hudson Shower Bed: ........................................................................................................................ 8
1. Prepare the mounting / dismount the top cover plate ....................................................................................... 9
2. Prepare the mounting / dismount the front plate .............................................................................................10
3. Mounting to the wall .........................................................................................................................................11
4. Remount the front plate ....................................................................................................................................13
5. Mount the shelves on the Lifting unit. ...............................................................................................................14
6. Mount the Shower tray on the Lifting unit. .......................................................................................................15
Wire diagram ........................................................................................................................................................19
Connecting cables..................................................................................................................................................20
Disconnecting cables .............................................................................................................................................20
Placement of the handcontrol. ..............................................................................................................................20
Labelling .............................................................................................................................................. 21
Label......................................................................................................................................................................21
Symbol view: .........................................................................................................................................................21
Support ................................................................................................................................................ 22
Fault finding ..........................................................................................................................................................22
Waste handling .....................................................................................................................................................22
Factors affecting the operation .............................................................................................................................22
Factors affecting storage and transport .................................................................................................................22
Spareparts ........................................................................................................................................... 23
Accessories .......................................................................................................................................... 24
Bed guard ..............................................................................................................................................................24
Maintenance ....................................................................................................................................... 25
Cleaning ................................................................................................................................................................25
CE- erklæring ....................................................................................................................................... 26
EU – Declaration of Conformity .............................................................................................................................26
Complaints........................................................................................................................................... 27
Page 3
General information
Product information
Product : Hudson Shower bed, height adjustable
Producer : Ropox, DK-4700 Naestved, Phone +45 55 75 05 00
Usability – The height adjustable shower bed can be used to nurse children and adults (up to 150Kg). The shower bed can be used at home, in day care center or institutions to obtain good and correct working conditions for the carer.
When not in use, the shower tray can be folded up against the wall to save space. By using the up and down button on the handheld control switch, the height adjustment of the shower bed can be performed.
Part Numbers
Length of
shower bed
Part No.
146cm 40-25023 178cm 40-25026 210cm 40-25029
It is important to read this manual before mounting and daily
use.
Page 4
General information
Technical data
Electrical connection: 230V, 50Hz, max 2.0A Standby consumption: 7W Duty cycle: Max 10%, 2 min/18 min Height: Work surface 30 – 100 cm Unit, B=60 cm, H=116cm, D=13cm Material – Frame: Welded steel tubes St.37, Stainless and aluminum Shower tray: ABS Surface treatment: Powder coating, white RAL 9010 matt, Chromate Maximum load: 150 kg
This product has CE-marking according to ”Medical equipment, Low
Voltage and EMC directives. Has been tested according to the European standards DS/EN ISO 12182 and DS/EN ISO 60601-1. This product is in risk group 1.
Daily use
Before start using this product, be sure that “main power” has been connected as described in electrical connections.
By using the up down bottom on the handheld control switch, the height adjustment of the shower bed can be performed. The control switch has a spiral cord, which can be pulled out to a length of 200cm.
The slat
The slats have two sides with different hardness and can be turned around in the Shower tray. The soft side is used, when the person on the Shower bed needs to be washed. The hard side is used, when the person on the Shower bed needs to be changed.
Maximum load onto the Hudson Shower bed 150 kg.
Page 5
General information
After use
When not using the shower bed, the shower tray can be folded up against the Lifting
unit. This way it will only take up the space of approx. 30cm from the wall.
Inside the lifting unit, a gas damper is mounted, to reduce the power needed, when
folding the tray up and down.
Page 6
General information
Recommendations in use
The height adjustable shower bed helps the caretaker to obtain the most optimal
working height.
Height adjustment allows you to customize the working height to the individual
carer, and can also save unnecessary lifting, when transferring from e.g. wheelchair.
To ensure optimum utilization of the shower bed features
and avoid accidents, it is important to observe some
basics safety procedures
NEVER leave a person on the shower bed unattended - not even for a very short
period.
The shower bed must be operated only by adults.
Pay particular attention to other people in the room, when using the shower
bed. Make sure that no children are playing under or with the shower bed.
Keep the hand control out of the reach of children. Make sure that they cannot
operate the shower bed unattended. A bracket for wall mounting is included with delivery.
Make sure that there is free space above and below the shower bed to allow
height adjustment. The shower bed is upfoldable, but please be aware of obstacles above, below and around the shower bed to prevent risk of trapping.
If the control switch has been damaged or stopped working, it has to be replaced
immediately. The up and down buttons are “push and hold”. The motor stops when the button is being released. This is a very important safety element.
If two shower beds are mounted next to each other, we recommend to mount a
side cover between, to avoid the risk of trapping.
Constantly be aware of objects under the shower bed.
Page 7
Mounting Instructions
Important info before mounting
Make sure that you allow free space on all sides of the Hudson unit as shown below.
Placement of the Main 230 V socket, the hot and cold Water and the Drain:
The main 230 V socket, the drain and the hot and cold water, must be placed in the free area beside the lifting unit and according to the national requirements for such installations.
Page 8
Mounting Instructions
Receiving the Hudson Shower Bed:
The Hudson Shower Bed will come in two packages. One for the “Lifting unit” and one for the “Shower tray unit”.
It is important to follow the mounting instructions to assemble the unit in the right way and to obtain a safe product.
Lifting unit
Shower tray
Page 9
Mounting Instructions
1. Prepare the mounting / dismount the top cover plate
Pull up the cover plate on the top of the lifting unit to get access to the nut, which holds the front plate. Loosen this nut.
Page 10
Mounting Instructions
2. Prepare the mounting / dismount the front plate
Slide the front plate out of the Lifting unit to get access to the wall mounting holes in the unit.
!! Be aware not to bend or scratch the front plate in the process !!
Page 11
Mounting Instructions
3. Mounting to the wall
Attach the frame securely to the wall by using adequate bolts and rawlplugs suitable for the type of wall construction / material on site. The Shower bed is being supplied with a set (8 pcs) of screws and rawlplugs, which is ONLY used to mount the unit in a concrete wall. If the unit must be mounted on another kind of wall, other kinds of plugs and screws must be used. Shower bed is tested according to a load of up to 150 kg. applied to the shower bed.
The attachment holes can be marked up on the wall, four possibilities in the top, and four in the bottom of the frame. Place the frame against the wall and make sure it is horizontal. The frame is standing on two adjustable feet. The holes in the frame are all Ø 10 mm. Remove the frame and drill the holes.
Force for each of the four screws in top of the unit:
F
screw
= (150 kg * 923)/(1122 * 4 screws)
F
screw
= 31 kg for each screw
If you have other objects mounted right next to this shower bed, you have to
consider the risk of trapping, and therefore consider a safe distance to the other
objects.
Make sure that no dust or other obstacles are interfering with the rollers, chain,
sprocket or gas springs. This can cause malfunction and damage the system
Page 12
Mounting Instructions
Page 13
Mounting Instructions
4. Remount the front plate
Slide the front plate back into the Lifting unit and fasten it with the nut.
Page 14
Mounting Instructions
5. Mount the shelves on the Lifting unit.
Use 4 pcs. M5x10 screws to mount the shelves on both sides of the lifting unit.
Page 15
Mounting Instructions
6. Mount the Shower tray on the Lifting unit.
Slide the Shower tray in between the Lifting unit and the support arms on the Lifting unit.
Page 16
Mounting Instructions
Fasten the Shower tray to the Lifting unit with 8 pcs. M8x16 through the bushings in the support arms.
Page 17
Mounting Instructions
7. Mount the cover plate on Shower tray
Place the cover plate between the two support arms underneath the Shower tray.
Fasten it with 4 pcs M5x10
Page 18
Mounting Instructions
8. Mount the Drain and Flexible hose on the Shower tray
Screw the plastic nut on the scuttle and tighteen it firmly. Connect the flexible hose to the drain tube and connect it to the drain in the wall or on the floor.
After mounting, make sure that the chain is in correct position on the sprocket,
also check that cable plugs is connected correctly to the control box.
Check that no cables can be trapped or squeezed
Connect the main power, and the shower bed is ready to be used.
Page 19
Electrical components
Wire diagram
The shower bed is delivered with the control box already mounted on the frame. The diagram shows how the cables which are connected to the control box.
All the plugs are water tight, and therefore they can be a little tricky to connect / disconnect. Make sure that the plugs are positioned correctly before they are pushed into the sockets at the control box. The plugs must be pushed into the sockets until the “O­ring” is no longer visible.
Motor, control box and control switch apply to IP66. This means that they are dust tight and protected against heavy seas, or powerful jets of water.
The electronic system is designed for periodical use only, this means a max. duty cycle of 10%; 2min on /18min off.
1. Control box
2. Mains cable 230V
3. Motor, connects to socket 1
4. End plugs, connects to socket 2, 3 & 4
5. Hand control, connects to HB socket
4
5
1
2
3
Page 20
Electrical components
Connecting cables
The shower bed is delivered with the control box already mounted on the frame.
Motor cable connects to socket 1. Socket 2, 3 & 4 are not in use and are blocked.
Control switch connects to ”HB”.
When all cables have been connected, use the safe locking bracket. Pushed in until you hear a “click”.
Mains cable connects to the socket at the side of the box.
Disconnecting cables
Mains cable can be pulled out (no safe locking bracket). Before the other cables can be disconnected, the safe locking bracket needs to be released / removed (use a screwdriver to remove). Locking clips at each end of the safe locking bracket have to be released before the bracket can be removed, and the cables can be disconnected.
Placement of the handcontrol.
Bracket for hand control can be placed at the wall as shown. To be mounted with the two screws which are delivered with the bracket.
To obtain the full IP66 value, it is very important that all the plugs have been pressed
firmly into the sockets and the safe locking bracket is mounted.
Hand control should be placed out of the reach of children
Page 21
Labelling
Label
Each shower bed has its own label as shown. The label contains information which is very important to specify when contacting your supplier. It also shows main power supply.
Symbol view:
User Manual must be read before use
Waste must be sorted. Most parts for re-use.
Type B equipment. As for EN 60601-1
Class 2 equipment. Without earth connection.
CE-marking. This product complies with the demands for general safety and
functionality in the relevant EU directives and standards.
EMC information The shower bed complies with the demands for electromagnetic compatibility (EMC), if installation and daily use is according to instructions in this Manual. In seldom situations the Shower bed might be affected by electronic signals from ex. Portable computers, cell phones etc.
Serial No. Item No.
Name / model
Production year & month
Max. load 150kg
See explanation below
Page 22
Support
Fault finding
Hudson does not move up or down by when operating using the hand control
Check if: Main power connected 230V. Motor is connected to control box Hand control is connected to control box Motor is overloaded
Hand control defect Check if:
Hudson works with another hand control By pressing the up or down button, no movement is achieved, only clicking sounds is are heard from control box
Plugs are not connected correctly.
Dismount all cables and re-connect.
Waste handling
Used equipment shall be disposed of according to the National law. We recommend to dismount the product to the greatest extent possible, in a way that most parts can be reused. Be aware that this product contains electronically components. Example of groups this product can be sorted in: metal, plastic, cables, electronics and parts for destruction.
Factors affecting the operation
Temperature: 0°C to 40°C
Relative humidity: 5% to 85% non-condensing
Factors affecting storage and transport
Page 23
Spareparts
Spareparts
97000431
Actuator/motor
Type : LA34.5
Stroke 350 mm
97000434
Control Box
Type : CB6096-2
97000425
Hand Control
Type : HB8195V0001+61
40*40090-180
Slat
40*40090-315
Flexible plumbing kit
Page 24
Accessories
Bed guard
Bed guard is available as an option. The brackets will be mounted underneath the
frame with the screws supplied.
Length of
Shower bed
Shower bed Bed guard foldable
L=126 cm
Bed end guard
Fixed
146cm 40-25023 40-25036 40-25038
178cm 40-25026 40-25036 40-25038
210cm 40-25029 40-25036 40-25038
Page 25
Maintenance
The Hudson is maintenance free. For safety reasons it is recommendable to check all mounting screws and moving parts to be sure all is tightened ok, and that all attachment to the wall is in correct and safe condition.
Cleaning
To clean this product, do not use a high-pressure washer. Simply use a soft cloth or sponge with soapy water (pH 7) of max 60°C or householding spirit. Always clean this product after use to prevent dirt from sticking to the surface.
Important:
Do not use scouring powder or other abrasives as they may scratch the surface. Also avoid the use of cleaning utensils with sharp edges. Never use strong mineral acids or alkali.
Page 26
CE- erklæring
EU – Declaration of Conformity
I hereby declare under sole responsibility that the following products:
40-25023 Hudson Shower bed, 146 cm
40-25026 Hudson Shower bed, 178 cm
40-25029 Hudson Shower bed, 210 cm
are all under Classification Class I and in conformity with the following directives and standards:
DIRECTIVES
The Council Directive No.2007/47/EEC, concerning Medical Devices
amended through Directive No.98/79/EC
2006/95/EEC Directive for Low-voltage, amended through Directive
No.93/68/EEC
2004/108/EEC, EMC-Directive, amended through Directives
No.92/31/EEC and 93/68/EEC
STANDARDS
DS/EN 1041: 2009 DS/EN ISO 10993-1: 2009 DS/EN 14971: 2008 DS/EN 60601-1+CORR: 2006 DS/EN 12182: 2002 DS/EN 60601-1-2: 2007 DS/EN ISO 9999: 2009
Dato:
01-05-2011
Page 27
Complaints
See General Terms of Sale and Delivery on www.ropox.com
Ropox A/S
Ringstedgade 221
DK – 4700 Naestved
Tel.: +45 55 75 05 00 Fax.: +45 55 78 05 50
E-mail: info@ropox.dk
www.ropox.de
Ropox A/S
Ringstedgade 221
DK – 4700 Naestved
Tel.: +45 55 75 05 00 Fax.: +45 55 78 05 50
E-mail: info@ropox.dk
www.ropox.com
Ropox A/S
Ringstedgade 221
DK – 4700 Næstved
Tel.: +45 55 75 05 00 Fax.: +45 55 78 05 50
E-mail: info@ropox.dk
www.ropox.dk
Loading...