Roper RUD1000K, RUD3000K, RUD4000M, RUD4500M, RUD5000K Dimension Guide

...
Undercounter Dishwasher
®
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
RUD1000K RUD3000K RUD4000M
RUD4500M RUD5000K RUD5750K
Electrical: 120-volt, 60-Hz, AC-only, 15- or 20-amp. electrical supply. Use copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended.
Water: A hot water line with 20-120 psi (138-862 kPa) water pressure. Water temperature must be 120°F (49°C) at dishwasher. Use 3/8" O.D. copper tubing with compression fitting or flexible stainless steel braided fill line (1/2" minimum plastic tubing is optional but not recommended). Use a 90° elbow with 3/8" N.P.T. external pipe threads on one end to connect to water inlet valve. Do not solder within 6" (15.2 cm) from water inlet valve.
Drain: Use the new drain hose supplied with your dishwasher. If this is not suitable, use a new drain hose with a maximum length of 12 feet (3.7 m) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the drain connector of the dishwasher. Must have a high drain loop 20 inches (50.8 cm) above the subfloor or floor. Connect drain hose to waste tee or disposer inlet above drain trap in house plumbing and 20 inches (50.8 cm) minimum above the floor. An air gap must be used if the drain hose is connected to house plumbing lower than 20 inches (50.8 cm) above subfloor or floor. Use 1/2" minimum I.D. drain line fittings.
Corner installation: Allow 2" (5,1 cm) minimum between corner wall and dishwasher opening.
Grommet is required for electrical cable or power supply cord hole cut in a metal cabinet.
Do NOT install dishwasher over carpeted floor. Accepts custom door panels:
RUD1000K, RUD3000K, RUD4000M
Accepts custom door and access panels:
RUD5000K, RUD5750K
Power supply line should enter through the right side of opening in shaded areas. Power supply line hole-direct wired: 3/4" (1.9 cm) Power supply line hole-with plug: 1-1/2" (3.8 cm)
Water line should enter through the left side of opening in shaded areas. Minimum 1/2" (12,7 mm) hole.
24" (61 cm)
*
20-3/4" (52.7 cm)
23-7/8" (60.6 cm)
33-7/8"
(86 cm) min.
* to front of
door frame
2-1/2"
(6.4 cm)
2-1/2"
(6.4 cm)
10"
(25.4 cm
)
4" (10.2 cm)
4" (10.2 cm)
4"
(10.2 cm)
5" (12.7 cm)
5" (12.7 cm)
2"
(5.1 cm)
2"
(5.1 cm)
34" (86.4 cm) min.*
6"(15.2 cm)
6"(15.2 cm)
24" (61 cm)
24" (61 cm)**
* Measured from the lowest point
on the underside of countertop.
** Minimum, measured from
narrowest point of opening.
Drain hose should enter through cabinet in shaded areas. Drain hose size: 1-1/2" (3.8 cm)
door panel (side view)
door panel (front view)
access panel (front view)
22 31/32" (58.3 cm)
All edges routed to 7/32" (5.6 mm) thickness. Note: This panel is wider than the door panel.
23 5/16" (59.2 cm)
7/32" (5.6 mm)
7/32" (5.6 mm)
3/8" (9.5 mm)
1" (25.4 mm)
Note: Access panel is wider than door panel.
18 21/32" (47.4 cm)
side view
door closed
door pivot
door opened
access panel
Cut door panel to clear access panel when door is in open position .
CUSTOM FRONT PANEL DIMENSIONS
4 7/16"
11.3 cm
(top view)
7/32" (5.6 mm) thick
access panel frame
1/4" (6.4 mm) min.
maximum weight is 8 lbs (3.6 kg). Heavy duty door springs required for door panels weighing more than 4 lbs (1.8 kg).
Ref. 3385181
03-09-04
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.