Roper RGS7646K, RGS7648K Dimension Guide

1"
PRODUCT MODEL NUMBER OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
RGS7646K RGS7648K
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
front view
** Opening is minimum for closet door. Louvered door with
equivalent air openings is acceptable.
*** 4" minimum from dryer cabinet rear panel to wall is required for
closet installation or non-exhausted installation.
Recessed front view
* Shelf of cabinet is not permitted
above dryer when non-exhausted
side view
29"
Max.
27-3/4"
Max.
42-3/8"
Ref. 3393136 Rev. A
10-17-02
Gas Dryer
®
3"
3"
48 sq. in.
**
24 sq. in.**
4"***
14"
max.
0" 0"
closet
door
15"*
Maximum length of exhaust system depends upon the type of duct, number of elbows and type of exhaust hood. The maximum length for both rigid and flexible duct is shown in the chart.
For exhaust systems not covered by the exhaust length chart, check with your Roper dealer or service center for a dryer manual Part No. 603197.
MAXIMUM LENGTH OF 4-INCH DIA. RIGID METAL DUCT
MAXIMUM LENGTH OF 4-INCH DIA. FLEXIBLE METAL DUCT
No. of
90°
turns
EXHAUST HOOD TYPE
ABC
A
B
C
2-1/2"
4"
4"
64 FT. 54 FT. 44 FT. 35 FT. 27 FT.
0 1 2 3 4
58 FT. 48 FT. 38 FT. 29 FT. 21 FT.
36 FT. 31 FT. 27 FT. 25 FT. 23 FT.
64 FT. 54 FT. 44 FT. 35 FT. 27 FT.
36 FT. 31 FT. 27 FT. 25 FT. 23 FT.
0 1 2 3 4
28 FT. 23 FT. 19 FT. 17 FT. 15 FT.
Gas supply: Dryer is equipped for use with NATURAL gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2 inch IPS. When acceptable to the gas supplier and local codes, 3/8-inch approved tubing may be used for lengths under 20 feet. For lengths over 20 feet, larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. If local codes permit, it is recommended that new flexible metal tubing, design-certified by AGA or CSA, be used for connecting the appliance to the rigid gas supply line. (The gas pipe which extends through the lower rear of the appliance has 3/8-inch male pipe thread.) An individual manual shutoff valve must be installed within 6 feet of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20-ampere, fused on both sides of the line. A separate circuit serving only this appliance is recommended. A time-delay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the outside. four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.