Roper REX3519PQ Dimension Guide

PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
RES6745P RES7646K RES7745P REX3514P
REX3519P REX3614P REX5634P REX6634P
Electrical: A four-wire or three-wire, single phase, 120/240-volt, 60 Hz, AC-only, electrical supply (or 120/208-volt electrical supply, if specified on the serial/rating plate) is required on a separate 30-amp circuit, fused on both sides of the line. Use 10 gauge solid copper wire. A time-delay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8535914
11-16-04
3. Wide Opening Side-Swing Door
4. Wide Opening Hamper Door
1. Small Opening Side-Swing Door
2. Large Opening Side-Swing Door
0
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart. In the column listing the type of metal vent you are using (rigid metal or flexible
metal), find the maximum length of metal vent on the same line as the number of elbows.
Electric Dryer
®
* Most installations require a
minimum 5-1/2” (14 cm) clearance behind the dryer for the exhaust vent with elbow. See Installations Instructions, “Venting Requirements.”
4"
(10.2 cm)
(1
4" (10.2 cm)
Louvered style
Vent Length Chart
Number of
90° turn s
or elbows
0Rigid metal
1Rigid metal
2Rigid metal
3Rigid metal
4Rigid metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
4" (10.2 cm)
Typ e of
vent
Box hood style
Box or
Louvered
hoods
64 ft (20 m) 36 ft (11 m)
54 ft (16.5 m) 31 ft (9.4 m)
44 ft (13.4 m) 27 ft (8.2 m)
35 ft (10.7 m) 25 ft (7.6 m)
27 ft (8.2 m) 23 ft (7 m)
Angled style
Angled
hoods
58 ft (17.7 m) 28 ft (8.5 m)
48 ft (14.6 m) 23 ft (7 m)
38 ft (11.6 m) 19 ft (5.8 m)
29 ft (8.8 m) 17 ft (5.2 m)
21 ft (6.4 m) 15 ft (4.6 m)
2.5"
(6.4 cm)
"
"
29"
"
(73.66 cm)
"
1
27
"
(70.5 cm)
"
5 "
4
(14 cm)
2
"
"
1
2
"
"
1. Recessed area
3
2. Side view - closet or confined area
3. Closet door with vents