Roper RED4440V, RED4400V User Manual

A. Recessed area B. Side view - closet or confined area C. Closet door with vents
A
B
C
18"* (45.7 cm)
1" (2.5 cm)
29"
(73.7 cm)
1" (2.5 cm)
1" (2.5 cm)
14" max.*
(35.6
cm)
27³⁄₄" (70.5 cm)
5"*
(12.7 cm)
48 in. (310 cm )
2
*
2
24 in. (155 cm )
2
*
2
3"* (7.6 cm)
3"* (7.6 cm)
29" (73.7 cm) Electric Dryer
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
RED4400V RED4440V
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10150612B
03-11-09
43³⁄₈"
(
110cm)
*26" (66cm)
29"
(73.7cm)
A
15¹⁄₄"
(38.7 cm)
43³⁄₈"
(110cm)
*27³⁄₄"
(70.5cm)
29"
B
22³⁄₄"
(57.8cm)
43³⁄₈"
(110cm)
13³⁄₄"
(34.9cm
)
*27³⁄₄"
(70.5cm)
29"
D
43
³⁄₈
"
110cm)
*27³⁄₄"
(70.5cm)
29"
C
22³⁄₄"
(57.8cm)
(73.7cm)
(73.7cm)
(73.7cm)
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.
2. Determine vent length.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
Electrical: To supply the required three- or four­wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply (or three- or four-wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Exhaust venting: Exhaust your dryer to the outside. 4" (10.2 cm) diameter heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended. For best drying performance, rigid metal vents are recommended. Flexible metal vents are acceptable only if accessible for cleaning. Do NOT use plastic or metal foil vent. Exhaust hood must be at least 12" (30.4 cm) from the ground or any object that may be in the path of the exhaust.
A. Small Opening
Side-Swing Door
B. Large Opening
Side-Swing Door
C. Wide Opening
Side-Swing Door
D. Wide Opening
Hamper Door
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust
vent with elbow.
Louvered style
4" (10.2 cm)
4" (10.2 cm)
Box hood style
4"
(10.2 cm)
2.5"
(6.4 cm)
Angled style
Vent Length Chart NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
®
*Required spacing
(
Vent Length Chart
Number of
90 turns
or elbows
0 Rigid metal
1 Rigid metal
2 Rigid metal
3 Rigid metal
4 Rigid metal
Type of
vent
Box or
Louvered
hoods
64 ft (20 m) 58 ft (17.7 m)
54 ft (16.5 m) 48 ft (14.6 m)
44 ft (13.4 m) 38 ft (11.6 m)
35 ft (10.7 m) 29 ft (8.8 m)
27 ft (8.2 m) 21 ft (6.4 m)
Angled