1187730
Your safety and the safety of others
are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
_1 his is the safety alert symbol.
All safety messages will follow the safety alert symbol and either the word "DANGER" or '"WARNING." These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the
instructions are not followed.
This symbol alerts you to potential hazards that can kill or hurt you
and others.
IMPORTANT SAFETY INSTRUCTIONS
WARNING m To reduce the risk of fire, electrical shock, injury or sickness when using your dehumidifier, follow these basic precautions:
Plug into a grounded 3 prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
SAVE THESE INSTRUCTIONS
Unplug dehumidifier before servicing.
Do not drink water collected in the water bucket.
ElectricalRequirements
Grounding instructions
3prongground-type
outlet .......
3prong "'. groundplug
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these
instructions can result in death, fire, or electrical shock.
A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15- or 20-ampere fused and properly grounded electrical
supply is required. A time-delay fuse or
time-delay circuit breaker is
recommended. Use a separate circuit to
connect only the dehumidifier.
""""_n_ ®
[_. prong
powersupplycord
For your personal safety, this dehumidifier must be grounded.This dehumidifier is equipped with a power supply cord having a 3 prong ground plug.
To minimize possible shock hazard, the cord must be plugged into a mating 3 prong ground-type outlet, grounded
in accordance with local codes and ordinances. If a mating outlet is not
available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified
electrician.
LocationRequirements
Good air circulation is needed for best performance - allow
at least 12-18 in. (30.5 -
45.7 cm) of air space on all sides of the dehumidifier.
(30.5-45.7cm]
Install dehumidifier on a level floor strong enough to support the
dehumidifier with a full bucket of water.
Install your dehumidifier in an area
where the temperature will not fall
below the minimum operating
temperature for your control type.
Lower temperatures will cause your performance to drop.
Keep all outside doors, windows and other
openings closed when operating dehumidifier.
Humid outdoor air will increase dehumidifier workload.
(30.5-45.7cm)
If you have Control type"A":
If ice forms on coils, unplug dehumidifier until ice clears and room
temperature rises. If you have Control Type "B" or"C":
Units with these control types have a deicer that will shut off the compressor
and allow the fan to run.When the deicer senses the correct operating
temperature, the compressor will cycle back on.
SettingtheControls
NOTE: Before turning dehumidifier on, be sure that:
Bucket is properly inserted into
dehumidifier
Bucket is empty
ControlA
Minimumoperating temperatureis65°F(18°C)
ControlB
Minimumoperating temperatureis55°F(13°C)...
selectsfan speed
Toturn dehumidifier on
Turn DRYNESSCONTROL clockwise. If the
Empty/Adjust Bucket light comes on, the
dehumidifier will not operate. Empty or adjust bucket.
indicatesthe bucketis full
.," OR
.../" thebucket is not in position
adjusts humidity removalset point (amountof moisture
removedfrom room)
indicatesthe bucketis fu!l
........ OR
thebucket is notin position
.......adjusts humidity removal set
point (amountof moisture removedfrom room)
Fan speed (Control B models only)
This controls fan operation. Use desired setting.
HIGH - for faster moisture removal. LOW - for slower moisture removal.
Toturn dehumidifier off
Turn DRYNESSCONTROL counterclockwise to OFF.
Empty/Adjust bucket light
If this light is on, the dehumidifier is not running.This light indicates that you
need to check: ° If the bucket is full, empty bucket and
replace.
° If the bucket is not in position, remove
bucket and replace. Make sure the bucket fits all the way into the
dehumidifier and the light is off, or dehumidifier will not run.
Drynesscontrol
This controls the amount of moisture in the room.Turn control knob clockwise
for more drying.Turn control knob counterclockwise for less drying.Turn
control knob to "NORMAL"to maintain average humidity conditions.
NOTE: For the first few days of use,turn the DRYNESSCONTROL clockwise to
"DRYEST'to remove extra moisture from the furnishings as well as the room air.
SettingtheControls
o ....... ..,A.,, indicatesthebucketisful!
o C,,,T_.UOU_ .d_! ...."'"" OR
ControlC
Minimum0perating temperatureis44°F(7%)
selectsmode
o.... __ ..... _ thebucketis notinposition
OL0W _ _ 0"';_:_,u. /
J
"'" adjustshumidityremovalsetpoint
(amountofmoistureremovedfromroom)
To turn dehumidifier on
Pressthe ON/OFF button. If the Empty/Adjust Bucket light comes on, the
dehumidifier will not operate. Empty or adjust bucket.
Each time you unplug the dehumidifier
or power is interrupted, the control will
return to your previous settings.
Toturn dehumidifier off
Pressthe ON/OFF button.The
dehumidifier will retain your last
settings.
Empty/Adjust bucket light
if this light ison, the dehumidifier is not
running.This light indicates that you need to check:
If the bucket is full, empty bucket and
replace.
If the bucket is not in position, remove
bucket and replace. Make sure the bucket fits all the way into the
dehumidifier and the light is off, or dehumidifier will not run.
Mode selection
Press MODE button to select fan speed.
Choose LOW, HIGH, CONTINUOUS or AUTO DRY.High speed will give a faster
response time to reach the humidity set point. Low speed will give a slower
response time to reach the humidity set point, but at a lower sound level.
If you have selected LOW or HIGH:
Press _ or _ to set the amount of moisture you want removed. Pressing
increases the amount of moisture
removed; pressing @ decreases the amount of moisture removed.The
indicator light will change according to the number of times you press O or _.
If you have selected CONTINUOUS:
You cannot select the amount of moisture you want removed. In
Continuous mode, the dehumidifier will run continuously regardless of the
humidity level. The dehumidifier will shut off only if the
bucket is full or removed. NOTE:The Deicer will turn the compressor off if a low temperature
condition exists.Pressing _; or O will not increase or decrease the amount of moisture removed.
If you have selected AUTO DRY:
Press _ or _ to set the amount of moisture you want removed. AUTO DRY
provides the best humidity control of all the modes by automatically adjusting the fan speed and/or turning the dehumidifier on and off to maintain your
settings.
Removing&EmptyingWater Bucket
Sickness Hazard
Do not drink water collected in water bucket.
Doing so can result in sickness.
Drain hose connection method:
(todrainwaterfrombucketcontinuously)
I I _/ . cIFaln nose connectoF
......... i \ j"..... cover(notonal!models)
--. ...... f ----- "
1. If your dehumidifier does not have a drain hose connector cover, go to
Step 2. If your dehumidifier has a drain hose
connector cover, use a flat-blade
screwdriver to remove cover from drain connector.Turn cover counterclockwise. Discard cover. It
cannot be reused. Go to Step 2.
_ jJ
1. Use both side handles to lift bucket. Pull bucket forward and remove.
2. Carry bucket to a large sink or tub.
3. Pour water through opening into a sink or tub.
4. Replace bucket completely and check that EMPTY/ADJUST BUCKET
light is off.
.. Donotdamage
.... outside,or
connection
wil!leak.
center of drain hose connector
2. Drill out only the center of the drain hose connector. Use a minimum
% in.drill bit.
'--... . ...--- ....
3. Attach a garden hose to drain hose connector.The garden hose should
not be longer than 8 ft (2.4 m). Run
other end of garden hose into a floor drain. Check that the hose lies flat
and in the drain.
Tousethebucketwithoutthegardenhose:
Use a garden hose cap to seal the drain hose connector.
WaterLevelFloat&Automatic Shutoff
All dehumidifiers have automatic shutoff and a water level float. All dehumidifiers
feature an adjustable Water Level Float. The bucket must be properly aligned for the Water Level Float to work.
Water Level Float Adjustment:
"High'setting: Water Level Float is preset to the"high" position - left side of opening.The dehumidifier will shut off automatically when bucket is % full.
You can set the adjustable Water Level
Float at the "high'or"low" position. Both settings will turn off the dehumidifier
automatically.To adjust water level, push float left or right until it snaps into place.
"Low" setting: Slide Water Level Float to "low" position - right side of opening - to make the bucket lighter to carry.The dehumidifier will shut off automatically
when bucket is % full.