INSTALLATION INSTRUCTIONS
Read installation instructions rst before installing. Check parts to ensure that no damage has occurred during transit and that no
parts are missing. Also check the diameter of the pipe and the range marked on the clamp to ensure you have the proper size.
Style SCS
Full Circumferential Repair Clamp
Step 1 • Check the Clamp parts to insure that no dam-
age has occurred during transit and that no parts are missing.
Also check the diameter of the pipe and the size marked on
the clamp to insure you have the proper size. Thoroughly
clean pipe surface that will be covered by the clamp. A suitable gasket lubricant should be used on rough surface pipe
to assure proper seal.
Step 2 • Place reference marks on the pipe in line with
the crack or hole in the pipe, slightly wider than the clamp.
Step 3 • Wrap gasket cartridge around pipe.
Step 5 • Slide the lifter bar up the receiver lug
prole and snap into place over the side bar edge. Slide
bolts and nuts up the receiver lug prole and snap bolts
into place on top of receiver lugs. Make sure the gasket
has seated itself at onto the pipe face. Tighten nuts nger
tight. Rotate clamp into position and center the bolts over
the crack or hole being repaired (check reference marks).
Step 6 • Tighten all nuts evenly in 15 ft-lb. increments.
Keep torques as evenly balanced as possible. Use a wrench
with at least a 12" handle.
Step 4 • Back off nuts of shell to the end of the bolt,
DO NOT REMOVE. Separate clamp and wrap it around the
gasket cartridge.
Document #10-9-0034 04/17/2015
Note: If necessary (because of water pressure) Step 4 and
Step 5 can be performed beside the pipe break. Slide the
clamp over the break after the lifter-bars have been snapped
in place.
21919 20th Avenue SE • Suite 100 • Bothell, WA 98021 • Phone (425) 951-6200 • 1-800-426-9341 • Fax (425) 951-6201
4
6
Torque Recommendation
30-35 ft-lbs.
For best results, wait 10 minutes and then re-tighten
to proper torque.
Note:
35 ft-lbs. torque =
12" wrench
w/35 lbs. force
INSTALLATION INSTRUCTIONS
Style SCS
Full Circumferential Repair Clamp
PRECAUTIONS
1. Check diameter of pipe to make sure you are using the correct size clamp.
2. Clean pipe to remove dirt and corrosion from the surface.
3. Place marks on the pipe to reference the leak. Use these marks to assure that the clamp is properly
positioned.
4. Make sure no foreign materials stick to the gasket as it is brought around the pipe, nor become
lodged between gasket and pipe as nuts are tightened.
5. Avoid loose tting wrenches, or wrenches too short to achieve proper torque.
6. Keep threads free of foreign material to facilitate tightening.
7. Bolts are often not tightened enough when a torque wrench is not used. Take extra care in this situation
to make sure proper tightening occurs.
8. Pressure test for leaks before backlling.
9. Backll and compact carefully around clamp.
10. When reinstalling parts with stainless steel hardware there may be a loss in pressure holding ability due
to worn or damaged threads during the original installation.
COMMON INSTALLATION PROBLEMS
1. Bolts are not tightened to the proper torque.
2. Rocks or debris between pipe and gasket.
3. Dirt on threads of bolts or nuts.
4. Repair clamp too small for the size of damage to pipe.
5. Repair clamp not centered over damaged portion of pipe.
6. Repair clamps should not be used as couplings.
21919 20th Avenue SE • Suite 100 • Bothell, WA 98021 • Phone (425) 951-6200 • 1-800-426-9341 • Fax (425) 951-6201