Romac Industries ARMOR LINK Installation Manual

ROMAC
INDUSTRIES,
2
INC.
Armor Link
INSTALLATION INSTRUCTIONS
Stainless Steel Coupling
The Armor Linkis not designed to withstand
that the product label matches your application.
Armor Link™ is compatible with steel, CI, DI, A/C,
Concrete, PVC and HDPE pipe.
Pipe stiffeners are required on HDPE pipe.
SIZE
(inches)
4.50 4.41 - 4.61 435 8 6
4.80 4.76 - 4.84 290 8 6
6.63 6.54 - 6.73 330 15 10
6.90 6.77 - 7.01 330 15 10
8.63 8.54 - 8.78 260 20 10
9.05 8.82 - 9.06 260 20 10
10.75 10.63 - 10.87 215 20 10
11.10 10.94 - 11.18 215 20 10
12.75 12.60 - 12.83 230 25 10
13.20 13.15 - 13.39 230 25 10
17.40 17.32 - 17.56 230 25 10
25.80 25.59 - 25.91 230 45 14
RANGE
(inches)
WORKING
PRESSURE
(PSI)
ALLOWABLE DEFLECTION
BOLT
TORQUE
(ft-lbs)
WRENCH
SIZE
(MM hex key)
Step 1Clean and eliminate any irregularities on
the pipe ends.
1
Step 3Slide the coupling over one pipe end with-
3
Step 4 • Bring the other pipe end to a facing
position. Make sure the pipes are aligned concentrically and that both pipe ends are correctly supported. See tolerances indicated on the label.
4
Step 2 On each pipe end, make a mark at a dis-
tance equal to half the width of the coupling.
Document # 10-9-0039 02/23/2015
21919 20th Avenue SE • Suite 100 • Bothell, WA 98021 • Phone (425) 951-6200 • 1-800-426-9341 • Fax (425) 951-6201
ROMAC INDUSTRIES, INC.
INSTALLATION INSTRUCTIONS
Armor Link
Stainless Steel Coupling
Step 5 • Place the coupling between the marks
and make sure that the armor is correctly placed under the bolts.
5
½ ½
Step 6 • Do not rotate the coupling or the pipe dur-
ing tightening. If there are three bolts, start with the center bolt, and begin tightening the bolts alternately and evenly to the required torque.
6
NOTE: Do not exceed the torque requirements indicated on the product label.
Step 7 • If necessary, you may hydraulically test the
coupling up to 1.5 times the working pressure shown on the product label.
HELPFUL HINTS
1. Be sure that the bolts are tightened to the proper torque shown on the label.
2. Eliminate any rocks or debris between pipe and gasket.
3. Eliminate any dirt on threads of bolts or nuts.
4. Pressure test for leaks before backlling.
5. Backll and compact carefully around coupling.
6. Reusing parts with stainless steel hardware may lead to a loss in pressure holding ability due to wear.
7. Make sure you have the proper size coupling.
21919 20th Avenue SE • Suite 100 • Bothell, WA 98021 • Phone (425) 951-6200 • 1-800-426-9341 • Fax (425) 951-6201
Loading...