Rolls RA63 User Manual

LIMITED WARRANTY
This product is warranted to the original consumer purchaser to be free from defects in materials and workmanship under normal installation, use and service for a period of one (1) year from the date of purchase as shown on the purchaser’s receipt.
The obligation of Rolls Corporation under this warranty shall be limited to repair or replacement (at our option), during the warranty period of any part which proves defective in material or workmanship under normal installation, use and service, provided the product is returned to Rolls Corporation, TRANSPORTATION CHARGES PRE­PAID. Products returned to us or to an authorized Service Center must be accompanied by a copy of the purchase receipt. In the absence of such purchase receipt, the warranty period shall be one (1) year from the date of manufacture.
This warranty shall be invalid if the product is damaged as a result of deface­ment, misuse, abuse, neglect, accident, destruction or alteration of the serial number, improper electrical voltages or currents, repair, alteration or maintenance by any person or party other than our own service facility or an authorized Service Center, or any use violative of instructions furnished by us.
This one-year warranty is in lieu of all expressed warranties, obligations or liabilities. ANY IMPLIED WARRANTIES, OBLIGA TIONS, OR LIABILITIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER­CHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED IN DURATION TO THE ONE YEAR DURATION OF THIS WRITTEN LIMITED WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
IN NO EVENT SHALL WE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, WHATSOEVER. Some states do not allow the exclusion or limitation of special, incidental or consequential damages so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
RA63
DISTRIBUTION AMPLIFIER
H 4 CH 5
CH 6
+ 20 dB
0 dB
PWR
CH 1
CH 2
4 ) $ ! >
CH 3 CH 4
ROLLS CORPORATION
SAL T LAKE CITY, UTAH
7/00
OWNERS MANUAL
INTRODUCTION
INSTALLATION
Thank you for your purchase of the R OLLS RA63 Distribution Amplifier. This unit will distribute six high-lev el balanced lines in a sound distribution system. The screw terminals on the rear panel are for input and output, and each output may power more than one line. The unit is intended for prof essional applications and has a FR4 double sided circuit board and painted steel chassis.
FEATURES
• 6 Distribution outputs on barrier strips
• Screw driver adjustable front panel v olume controls
• Balanced inputs and outputs
• Clean, quiet operation
DESCRIPTION
FRONT PANEL
CH 1
CH 2
CH 3 CH 4 CH 5
+ 20 dB
CH 6
0 dB
PWR
4 ) $ ! >
VOL 1 - 6: These screwdriver adjustable controls adjust the le v el of output signal for each indicated output. +20dB/0dB Switch: Pressing this s witch in provides 20 dB of gain to the input signal. PWR: LED indicating the unit’ s po wer status.
REAR PANEL
120 VAC
50/60 Hz 15 VA
MODEL RA63
SERIAL NUMBER
63-
MADE IN U.S.A.
12 VAC
INPUT
CH 5
CH 3
CH 4
CH 6
-
-
-
+
-
+
+
CH 1
CH 2
+
-
+
-
-
+
+
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT NOT REMOVE BACK. NO USER SERVICABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
RISQUE DE CHOC - NE PAS ENLEVER
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
DO NOT OPEN
NRTL /C
120 VAC 50/60 HZ 15 VA: Power Cord. Connect to a properly grounded A C source.
12 VAC: These two terminals provide 12 volts of ac current. These are a v ailab le for connection to low pow er accessory units. INPUT: These three terminals, labeled + for the positive or “hot” connection, - for the negative connection, and the ground symbol for earth ground connection are for connection to the balanced or unbalanced input signal to be distributed. CH6 - CH1: F or each channel; the two terminals labeled + for the positive or “hot” portion of the output signal, and the - for negative or neutral portion. The g round signal indicates the terminal to be connected to earth ground. This terminal may be lifted in the event of ground loops .
Install the RA63 in a standard 19 rack. The unit is intended for installations where sever al zones or areas need to be controlled and a high le vel balanced signal is required to drive the input lines.
SPECIFICATIONS
Input Impedance: 100 K balanced Max Input Level: +22 dBV I/O Connectors: Screw terminal; +. -, and ground Output Impedance: 50 balanced Max Output Level: +24 dB Max Gain: 20 dB S/N Ratio: >90 dB THD: <.008% Power: 120 VAC 50-60 Hz, 15VA Size: 19 x 1.75 x 6.5
(48 x 4.5 x 17 cm)
Weight: 7 lbs. (3 kg)
SCHEMATIC
C 1 D
C I R C U I T G R O U N D
1 2 V A C
+ I N
- I N
O U T
C H 5
C H 6
1 2
3
4 5
P L 1
P L U G A C M A L E
S W 2
S W S P S T
R 2 D
1 2 0 P F
1 2 0 P F
1 0 U
5 1
C 1 E
1
3
C 9
2 3
C 4
1 0 0 0 U F 1 6 V
C 5
1 0 0 0 U F 1 6 V
C 2 D 1 0 U
1 0 U
C 2 E 1 0 U
2 0 d B B O O S T
R 9 4 . 7 K
O U T +
1
2
3
4
5
R 1 1
1 0 0 K
1 2 0 P F
4 5 6 0
U 7 A
4
- 1 2
R 1 0 4 . 7 K
C H 1
O U T -
G N D
O U T +
O U T -
S 1 A
2
C 1 0 5 0 3
C H 2
C H 3
D P D T
C H 4
1
D 5 L D S G
P O W E R
4 5 6 0
2
U 1 A
3
P 1 1 0 K
4
-12
4 5 6 0
2
U 1 A A
3
P 2 1 0 K
4
-12
2
U 1 B A
3
P 3 1 0 K
4
-12
4 5 6 0
2
U 1 C A
3
P 4 1 0 K
4
-12
5 1
R 4 D
5 1
R 2 E
R 4 E
5 1
R 1 3
1 0 K
1 0 K
+12V
-12V
+12
R 1 D
1 0 K
1
R 1 E 1 0 K
1
C 7 1 2 0 P F
6 5
T 1
R 5
1 0 K
6 5
6 5
R 8 1 0 K
+12
8
U 7 B
R 3 D 1 0 K
+12
R 3 E
4 5 6 0
8
U 1 D B
8
U 1 E B
4 5 6 0
C 3 D
4 5 6 0
C 3 E
1 0 K
7
D 1 1 N 4 0 0 1
D 4
1 N 4 0 0 1
7
7
R 1 2
D 2 1 N 4 0 0 1 D 3 1 N 4 0 0 1
4 5 6 0
2
U 1 D A
3
P 5
1 0 K
4
-12
4 5 6 0
2
U 1 E A
3
P 6
1 0 K
4
-12
R 7
1 0 K
C 8
1 0 2
R 6 1 0 K
C 6
1 2 0 P F
M C I 4 0 7 4 0 2 4
+12
8
R 1
1 0 K
1
6
U 1 B
5
1 0 K
R 3
+12
8
R 1 A
1 0 K
1
6
U 1 A B
5
1 0 K
R 3 A
+12
8
R 1 B
4 5 6 0
1 0 K
1
6
U 1 B B
5
R 3 B
+12
R 1 C
8
1 0 K
1
6
U 1 C B
5
R 3 C 1 0 K
Title: RA63 DISTRIBUTION AMPLIFIER Size
Ba
Date: 31-Jul-2000
R 2
C 1
5 1
4 5 6 0
R 4
7
5 1
C 3
4 5 6 0
7
C 3 A
4 5 6 0
C 3 B
1 0 K
4 5 6 0
C 3 C
ROLLS CORPORATION
5968 South 350 West
Salt Lake City, UT 84107
Document Number: RA63.SCH
1 2 0 P F
1 2 0 P F
7
7
1 2 0 P F
1 2 0 P F
R 2 A 5 1
C 2
1 0 U
C 1 A
R 4 A
C 2 A
5 1
1 0 U
R 2 B
C 1 B
5 1
R 4 B
5 1
1 0 U
5 1
R 2 C
C 1 C 1 0 U
R 4 C
C2C
5 1
1 0 U
1 0 U
OUT +
1
OUT -
2
G N D
3
OUT +
4
OUT -
5
1
2
3
4
5
Sheet 1 of 1
OUT +
OUT -
GND
OUT +
OUT -
Rev: A