AUTOMATE
™
Paradigm Flush Wall Switch
433 MHz
AUTOMATE™ | Paradigm flush wall switches feature a contemporary design and a
wirefree deployment, making them retrofit ready for any location. Paradigm 5 channel
switches are perfect for individual shade, room and whole home control.
The Paradigm flush mount switch can be mounted on top of any surface. Its slim profile
eliminates the need for any holes to be cut in walls.
FEATURES:
• Multi channel selectable
• Retrofit Ready
• Group Control
• Compatible with screwless decorator cover plates
• Optionally functions as handheld remote
MTRF-WS5-FLUSH_PRGM_v1.3 FEB 2018

CONTENTS
1 TECHNICAL DATA / PACK CONTENTS 3
2 SAFETY 4
3 INSTALLATION 5
3.1 Kit Components 5
3.2 Install switch batteries 5
3.3 Magnetic Wall Clip 6
3.4 Fixed Wall Clip 6
4 FUNCTIONAL OVERVIEW 7
4.1 Buttons 7
4.2 Selecting a channel 7
5 PROGRAMMING 8
5.1 Using the P1 button 8
5.2 Using a pre-existing controller 9
6 INITIAL SETUP 10
6.1 Check motor direction 10
6.2 Set limits 10
6.3 Locking the limit setting function 11
7 ADJUSTING LIMITS 12
7.1 Adjusting upper limit 12
7.2 Adjusting lower limit 12
8 FAVORITE POSITIONING 13
8.1 Set a favorite position 13
8.2 Send shade to favorite position 13
8.3 Delete favorite position 13
9 TROUBLESHOOTING 14
2 | Automate™ Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA

1 TECHNICAL DATA / PACK CONTENTS
TECHNICAL SPECIFICATIONS
Voltage: 3V (CR2430)
Frequency: 433.92 MHz
Transmitting Power: 10 milliwatt
Ambient Operating Temperature: -10°C -50°C
Transmission Distance: up to 200 meters (open space)
ROLLEASE ACMEDA Automate™ Programming Instructions | Flush Wall Switch | 3

2 SAFETY
WARNING: Important safety instructions to be read before installation and use.
Incorrect installation or use can lead to serious injury and will void manufacturer’s liability and warranty.
It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference.
• Do not expose to water, moisture, humid and damp environments or extreme temperatures.
• Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge
should not be allowed to use this product.
• Use or modification outside the scope of this instruction manual will void warranty.
• Installation and programming to be performed by a suitably qualified installer.
• Follow installation instructions.
• For use with motorized shading devices.
• Keep away from children.
• Frequently inspect for improper operation. Do not use if repair or adjustment is necessary.
• Keep clear when in operation.
• Replace battery with correctly specified type.
Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of
R&TT EC Directive 1999/5/EC
This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt
RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
Do not dispose of in general waste.
Please recycle batteries and damaged electrical products appropriately.
4 | Automate™ Programming Instructions | Flush Wall Switch ROLLEASE ACMEDA
5005833

3 INSTALLATION
Kit Components
3.1
1. 1 x Cover
2. 1 x Switch Remote
3. 1 x Magnetic Wall Clip
4. 1 x Fixed Wall Clip
5. 2 x Pan Head Screw
6. 2 x Phillips Head Screw
7. 2 x Wall Plug
8. 3V - CR2430 Battery
9. Programming Manual
Install switch batteries
3.2
1.5. 2. 6.8. 3. 7. 4.
Open rear battery cover by gently separating
switch covers with a screwdriver
ROLLEASE ACMEDA Automate™ Programming Instructions | Flush Wall Switch | 5
Install CR2430 battery with positive side facing
up. Snap covers back together.
Snap covers back together.