AUTOMATE™ | ARC™ Venetian blind motor enables motorized tilting function of most 2”
venetian blinds. Precisely control the openness of blind vanes or simply recall a favorite
position.
Automate DC motors are powered from a 12V DC power source. AA Battery wands, re-chargeable battery
packs and A/C power supplies are available, with a variety of quick connect extension cords. For centralized
installations, power supply range can be extended with 18/2 wire (not available through Rollease Acmeda).
• During operation, if voltage drops to less than 10V, the motor will beep 10 times to indicate a power
supply issue.
• Motor will stop running when the voltage is lower than 7V and it will resume again when the voltage is
greater than 7.5V.
DC Power Supply
Power SupplyMotor
MTDCRF18-0.2 - 18mm DCRF Motor, .2N/80
MTBWAND18-25 Battery Tube for 18/25mm DCRF (no Battery) Mtrs
(inc Mt clips)
MTDCPS-18-25 Power Supply for 18/25-CL/Tilt DCRF (no Bttry) Mtr
MTBPCKR-28 Rechargeable Wand
MTDCRF25-1.1 25mm DCRF Motor, 1.1N/40r
MTDCRF-TILT-1
MTDCRF-CL-0.6-50
MTDCRF18-0.2 - 18mm DCRF Motor, .2N/80
MTDCRF25-1.1 25mm DCRF Motor, 1.1N/40r
MTDCRF-TILT-1
MTDCRF-CL-0.6-50
MTDCRF18-0.2
MTDCRF25-1.1
MTDCRFQ28-2
MTDCRF-TILT-1
MTDCRF-CL-0.6-50
Extension CablesLength
MTDC-CBLXT6 DC Battery Motor Cable extender 6” / 155mm6 inch
MTDC-CBLXT48 DC Battery Motor Cable extender 48” / 1220mm48 inches
MTDC-CBLXT96 DC Battery Motor Cable extender 96” / 2440mm96 inches
Ensure cable is kept clear of fabric.
Ensure antenna is kept straight and away from metal objects.
Battery in wand are depletedReplace 8xAA alkaline batteries.
Power failure
Transmitter battery is discharged Replace battery
Battery is inserted incorrectly
Motor is not responding
Unable to adjust or set limits.Remote is in a locked state.
Cannot program a single Motor
(multiple motors respond)
into transmitter
Radio interference/shielding
Receiver distance is too far from
transmitter
Incorrect wiring
Multiple motors are paired to the
same channel.
Check motor to power cable
connection and AC plug.
Check power supply to motor is
connected and active
Check battery polarity
Ensure transmitter is positioned
away from metal objects and the
aerial on motor or receiver is kept
straight and away from metal
Move transmitter to a closer
position
Check that wiring is connected
correctly (refer to motor
installation instructions)
Change remote status to an
unlocked state
Always reserve an individual
channel for programming
functions
SYSTEM BEST PRACTICE - Provide
an extra 15 channel remote in your
multi motor projects, that provides
individual control for each motor
for programming purposes
Place all other motors into sleep
mode (ref to P1 function overview
This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt
RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment.
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
ROLLEASE ACMEDA
AUSTRALIA
110 Northcorp Boulevard,
Broadmeadows VIC 3047
T +61 3 9355 0100 | F +61 3 9355 0110
Queensland Branch
Unit 2/62 Borthwick Avenue,
Murarrie QLD 4172
ROLLEASE ACMEDA
USA
200 Harvard Avenue
Stamford, CT 06902 6320
T +1 203 964 1573 | F +1 203 964 0513
ROLLEASE ACMEDA
EUROPE
Via Conca Del Naviglio 18, Milan
(Lombardia) Italy
T +39 02 8982 7317 | F +39 02 8982 7317
info@rolleaseacmeda.com
rolleaseacmeda.com
15 | Automate™ Programming Instructions | ARC™ Venetian Tilt Motor