rollease acmeda AUTOMATE MT01-1145-069011, AUTOMATE MT01, AUTOMATE Programming Instructions Manual

AUTOMATE
X50 VERTICAL DROP AWNING MOTOR
433 MHZ
BI-DIRECTIONAL
ELECTRONIC
FAVORITE POSITION
AUTOMATE | X50 Vertical Drop Awning Motor combine the simple, intuitive features of ARC “Automate Radio Communication” with the higher lifting capacity of an AC motor for larger shade applications.
INSTR. MT01-1145-069011 v1.1 OCT 2018
2 | Automate™ Programming Instructions | ARC VDA Motor ROLLEASE ACMEDA
CONTENTS
1 ASSEMBLY 4
2 WIRING 5
3 P1 BUTTON FUNCTIONS 6
3.1 Motor state test 6
3.2 Motor configuration options 6
4 INITIAL SET UP 7
4.1 Pair motor with controller 7
4.2 Check motor direction 7
4.3 Set Limits 8
5 ADJUSTING LIMITS 9
5.1 Adjust upper limit 9
5.2 Adjust lower limit 9
6 ADDING OR REMOVING CONTROLLERS AND CHANNELS 10
6.1 Using motor P1 Button to add a new controller or channel 10
6.2 Using a pre-existing controller to add or remove a controller or channel 10
7 FAVORITE POSITIONING 11
7.1 Set a favorite position 11
7.2 Send shade to favorite position 11
7.3 Delete favorite position 11
8 SLEEP MODE 12
9 WIND SENSOR FUNCTION 13
9.1 Wind Sensor Prioritize Function 13
9.2 Off line Wind Sensor Function 13
11 TROUBLE SHOOTING 14
3 | Automate™ Programming Instructions | ARC VDA Motor ROLLEASE ACMEDA
SAFETY INSTRUCTIONS
WARNING: Important safety instructions to be read before installation.
Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty.
CAUTION
Do not expose to moisture or extreme temperatures.
Do not allow children to play with this device.
Use or modification outside the scope of this instruction manual will void warranty.
Installation and programming to be performed by a suitably qualified installer.
For use within tubular blinds.
Ensure correct crown and drive adaptors are used for the intended system.
Keep antenna straight and clear from metal objects
Do not cut the antenna.
Use only Rollease Acmeda hardware.
Before installation, remove any unnecessary cords and disable any equipment not needed for powered operation.
Ensure torque and operating time is compatible with end application.
Do not expose the motor to water or install in humid or damp environments.
Motor is to be installed in horizontal application only.
Do not drill into motor body.
The routing of cable through walls shall be protected by isolating bushes or grommets.
Ensure power cable and aerial is clear and protected from moving parts.
If cable or power connector is damaged do not use.
Important safety instructions to be read prior to operation.
It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference.
Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge
should not be allowed to use this product.
Keep remote controls away from children.
Frequently inspect for improper operation. Do not use if repair or adjustment is necessary.
Keep motor away from acid and alkali.
Do not force the motor drive.
Keep clear when in operation.
Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately.
4 | Automate™ Programming Instructions | ARC VDA Motor ROLLEASE ACMEDA
.
Crown
Magnetic Ring
Bracket
Drive
Adapter
Retaining Clip
Motor Head
Step 1. Cut roller tube to required length.
Please refer to Rollease Acmeda System Assembly Manual for full assembly instructions relevant to the hardware system being used.
Step 2. Ensure roller tube is clean and free from burrs.
Step 3. Fit required crown, drive and bracket adapters.
Step 4. Slide Motor into tube.
Insert by aligning key-way in crown and drive wheel into the tube.
Step 5. Mount motorized tube onto brackets.
Refer to Rollease Acmeda System Assembly Manual for recommended crown, drive and bracket adapter kits.
1 ASSEMBLY
For impact dectection to be functional, a 2 piece drive set must be used. Using a standard 1 piece drive will render the collision control feature inoperable even if the feature is turned on.
Tube must be close fitting with chosen crown and drive adapters. A Hall effect sensor embedded in the tube measures the magnetic field change and detect the impact. Refer to Rollease Acmeda System Assembly Manual for recommended crown, drive and bracket adapter kits.
5 | Automate™ Programming Instructions | ARC VDA Motor ROLLEASE ACMEDA
1 2 3
Disconnect the mains power supply.
Connect the motor according to the information in the table below.
Ensure cable is kept clear of fabric.
Ensure antenna is kept straight and away from metal objects.
Power OFF
Water proof connector
2 WIRING
MOTOR POWER NEUTRAL LIVE EARTH
MT01-1145-069011 220-240V AC 50Hz Blue Brown Yellow/Green
DO NO T RE MO VE THIS LABEL
WARNING
E L E C TRIC AL H AZARD !
Power shall only be supplied to this cable once male & female connectors are correctly coupled.
Isolate power prior to connecting or disconnecting this motor.
This connector must not be acces­sible to the end user. It shall be placed within a pelmet box or within a housing in accordance to AS/NZS 60335.1:2011 or (BS) EN 60335-1:2012 Failure to do so could compromise personal safety.
DO NOT REMO VE THI S LABEL
WARNING
ELE C TRIC A L H AZARD !
Power shall only be supplied to this cable once male & female connectors are correctly coupled.
Isolate power prior to connecting or disconnecting this motor.
This connector must not be acces­sible to the end user. It shall be placed within a pelmet box or within a housing in accordance to AS/NZS 60335.1:2011 or (BS) EN 60335-1:2012 Failure to do so could compromise personal safety.
P1 button on motor head
3
2
1
Loading...
+ 9 hidden pages