Roland Professional A/V XI-SDI, XI-MADI Users Manual

Before using this unit, carefully read “USING THE UNIT SAFELY” and “IMPORTANT NOTES”
* 5 1 0 0 0 4 4 9 3 1 - 0 1 *
on back side. After reading, keep the document(s) including those sections where it will be available for immediate reference.
Copyright © 2015 ROLAND CORPORATION
Setup Guide
Main Features
MADI (Multichannel Audio Digital Interface) is a transmission standard for digital audio
standardized by AES. An extension of the AES/EBU standard for stereo (two-channel) transmission, it permits transmission of up to 64 channels over a single cable.
The main features of the XI-MADI are as follows.
• Equipped with two types of MADI connectors: optical and BNC
Optical and BNC (coaxial) MADI connectors are provided. You can select separate connectors for both MADI 1 and MADI 2.
Thank you, and congratulations on your choice of the XI-MADI expansion interface.
Installing this expansion interface card in professional audio equipment from Roland makes it possible to expand audio input and output using MADI (Multichannel Audio Digital Interface).
For information on devices on which the XI-MADI expansion interface can be installed, check the Roland website.
http://proav.roland.com
Panel Descriptions
1
2
2
Installing the Expansion interface
Install the expansion interface on a compatible device.
Important Notes on Handling
• Before you touch the expansion interface, always rst grasp a metal object (such as a water pipe), so you are sure that any static electricity you might have been carrying has been discharged.
• When handling the expansion interface, grasp it only by the panel or the expansion interface’s edges. Avoid touching any of the electronic components or connectors.
• Before you connect any cables, make sure they do not carry a static electricity charge. Such charges can be transmitted, for example, if the other end of the cable has been in contact with a carpet (or other object) where there is a static electricity buildup.
• Save the bag in which the expansion interface was originally shipped, and put the expansion interface back into it whenever you need to store or transport it.
Installing
NOTE
• Before installing the expansion interface, you must rst always turn o the unit where installing and unplug its power cord from the power outlet.
• When restarting the device with the expansion interface installed, wait several seconds before turning on the power.
1. Loosen the EXPANSION SLOT mounting screws (2) on the device where you’re
installing, and detach the panel cover.
Attaching Ferrite Cores
Attach ferrite cores to cables connected to the MADI IN/OUT connectors (coaxial) or VIDEO SYNC IN connector.
* The ferrite cores are needed to prevent electromagnetic noise. Be sure to attach ferrite
cores to any cables connected to the MADI IN/OUT connectors (coaxial) or the VIDEO SYNC IN connector.
1. Open an included ferrite core by spreading apart the tabs at two places.
2. Attach the ferrite core at a location near the plug base.
Close the ferrite core by pressing down on each tab until it clicks into place.
MEMO
Connect the plug at the end where the ferrite core is attached to the connector on the other device.
* When signals on the same channel are input via both the optical connector and the
BNC connector, the BNC input takes priority.
* Once optical input has been selected, the system does not switch to BNC as long as
an optical signal continues to be input.
* Depending on the equipment in which the XI-MADI is installed, locking input to
optical or BNC might be possible.
• Support for redundant main and backup transmission
Using a MADI 1 connector as main and a MADI 2 connector as backup is possible. In the event of a problem with the main connection, the system automatically switches to the backup connection.
* Redundant transmission uses either all-optical or all-BNC connections. Redundant
transmission combining optical with BNC is not supported.
• Equipped with a VIDEO SYNC IN connector
A VIDEO SYNC IN connector allowing black-burst signal input is provided. Selecting the VIDEO SYNC IN connector as the clock source enables synchronization with video equipment.
* For information on the equipment in which the XI-MADI can be installed, check the
following Roland website.
http://proav.roland.com
No. Name Explanation
This is for input of a black-burst signal.
VIDEO SYNC IN
1
connector
MADI IN/OUT connectors 1, 2
2
(optical)
MADI IN/OUT connectors 1, 2
3
(coaxial)
Here you connect a black-burst generator or other such external source device when synchronizing the XI-MADI-compatible device to video equipment.
These are optical-type connectors for MADI input and output.
* When no cable is used, attach the connector cap to prevent
entry by dust or other foreign matter. The unit is shipped from the factory with the connector caps attached to the connectors.
About optical cables
• Use multi-mode ber-optic cable having a core diameter or 50/125 μm or 62.5/125 μm.
• Cable length can be up to 2,000 meters per cable.
• Use SC connectors compliant with ISO/IEC 9314-3.
These are BNC-type connectors for MADI input and output.
About coaxial cables
• Use cables whose impedance is 75 Ω.
• Cable length can be up to 100 meters per cable.
• Use BNC-type connectors compliant with IEC 60169-8.
• Canare L-5C2VS cable or equivalent is recommended.
3
3
2. Insert the expansion interface into the EXPANSION SLOT.
* Do not touch any of the expansion interface pathways or connection terminals. * Never use excessive force when installing a expansion interface. If it doesn’t t properly
on the rst attempt, remove the expansion interface and try again.
3. Secure the expansion interface in place using the mounting screws (2).
Main Specications
Channels Up to 64 channels input/output x 2 (48 kHz, 44.1 kHz, 64 ch mode)
Up to 32 channels input/output x 2 (96 kHz, 64 ch mode)
* The number of available channels will be changed by the device that
attach the XI-MADI.
Signal Processing
Data Length 24 bits
Connectors
Power Consumption
Dimensions 120 (W) x 185 (D) x 40 (H) mm
Weight 250 g
Operation Temperature
Accessories
(*1): For single mode type, consult your Roland vendor.
* In the interest of product improvement, the specications and/or appearance of this unit
are subject to change without prior notice.
Sampling Frequency 96 kHz, 48 kHz, 44.1 kHz
MADI channel mode 64 ch, 56 ch
Coaxial MADI IN (1, 2) connectors BNC type
Coaxial MADI OUT (1, 2) connectors BNC type
Optical MADI IN/OUT (1, 2)connectors SC duplex multi mode type (*1)
VIDEO SYNC IN connector BNC type
USB COMPUTER port (Inside of the panel, updates only)
7.0 W
4-3/4 (W) x 7-5/16 (D) x 1-5/8 (H) inches
* Protruding parts not included.
9 oz
+5 to +40 degrees Celsius
+41 to +104 degrees Fahrenheit
Setup Guide, Ferrite core x 5
USB type B
USING THE UNIT SAFELY IMPORTANT NOTES
For the USA
For the USA
For China
Placement
About WARNING and CAUTION Notices
Used for instructions intended to alert the user to the risk of death or severe injury should the unit be used improperly.
Used for instructions intended to alert the user to the risk of injury or material damage should the unit be used improperly.
* Material damage refers to damage or
other adverse effects caused with respect to the home and all its furnishings, as well to domestic animals or pets.
ALWAYS OBSERVE THE FOLLOWING
WARNING
Do not disassemble or modify by yourself
Do not carry out anything unless you are instructed to do so in the Setup Guide. Otherwise, you risk causing malfunction.
Do not repair or replace parts by yourself
Refer all servicing to your retailer, the nearest Roland Service Center, or an authorized Roland distributor, as listed on the “Information.”
Do not use or store in the following types of locations
• Subject to temperature extremes (e.g., direct sunlight in an enclosed vehicle, near a heating duct, on top of heat­generating equipment); or are
• Damp (e.g., baths, washrooms, on wet oors); or are
• Exposed to steam or smoke; or are
• Subject to salt exposure; or are
• Exposed to rain; or are
• Dusty or sandy; or are
• Subject to high levels of vibration and
shakiness; or are
• Placed in a poorly ventilated location.
Do not allow foreign objects or liquids to enter unit; never place containers with liquid on unit
Do not place containers containing liquid (e.g., ower vases) on this product. Never allow foreign objects (e.g., ammable objects, coins, wires) or liquids (e.g., water or juice) to enter this product. Doing so may cause short circuits, faulty operation, or other malfunctions.
Turn o the unit if an abnormality or malfunction occurs
Immediately turn the unit o, and request servicing by your retailer, the nearest Roland Service Center, or an authorized Roland distributor, as listed on the “Information” when:
• Objects have fallen into, or liquid has
• If smoke or unusual odor occurs; or
• The unit has been exposed to rain (or
• The unit does not appear to operate
Be cautious to protect children from injury
Always make sure that an adult is on hand to provide supervision and guidance when using the unit in places where children are present, or when a child will be using the unit.
Do not drop or subject to strong impact
Otherwise, you risk causing damage or malfunction.
Turn the unit o before installing expansion interfaces
Before installing the expansion interface (XI-MADI), you must rst always turn o the unit where installing and unplug its power cord from the power outlet.
About the Symbols
The symbol alerts the user to important instructions or warnings.The specific meaning of the symbol is determined by the design contained within the triangle. In the case of the symbol at left, it is used for general cautions, warnings, or alerts to danger.
The symbol alerts the user to items that must never be carried out (are forbidden). The specific thing that must not be done is indicated by the design contained within the circle. In the case of the symbol at left, it means that the unit must never be disassembled.
The symbol alerts the user to things that must be carried out. The specific thing that must be done is indicated by the design contained within the circle. In the case of the symbol at left, it means that the power-cord plug must be unplugged from the outlet.
WARNING
been spilled onto the unit; or
otherwise has become wet); or
normally or exhibits a marked change in performance.
CAUTION
Route all cables in such a way as to prevent them from getting entangled
Injury could result if someone were to trip on a cable and cause the unit to fall or topple.
Avoid climbing on top of the unit, or placing heavy objects on it
Otherwise, you risk injury as the result of the unit toppling over or dropping down.
Disconnect all cords/cables before moving the unit
Damage or malfunction may result if you fail to disconnect all cables before moving the unit.
Install expansion interface(s) only in specied units
Install the expansion interface only into the specied unit (a device compatible with the XI-MADI). Remove only the specied screws during the installation.
Keep small items out of the reach of children
To prevent accidental ingestion of the parts listed below, always keep them out of the reach of small children.
• Included Parts Ferrite core
• Removable Parts Connector cap
Screws
• This unit may interfere with radio and television reception. Do not use this unit in the vicinity of such receivers.
• Noise may be produced if wireless communications devices, such as cell phones, are operated in the vicinity of this unit. Such noise could occur when receiving or initiating a call, or while conversing. Should you experience such problems, you should relocate such wireless devices so they are at a greater distance from this unit, or switch them o.
• When moved from one location to another where the temperature and/or humidity is very dierent, water droplets (condensation) may form inside the unit. Damage or malfunction may result if you attempt to use the unit in this condition. Therefore, before using the unit, you must allow it to stand for several hours, until the condensation has completely evaporated.
• Do not place containers or anything else containing liquid on top of this unit. Also, whenever any liquid has been spilled on the surface of this unit, be sure to promptly wipe it away using a soft, dry cloth.
Maintenance
• Never use benzine, thinners, alcohol or solvents of any kind, to avoid the possibility of discoloration and/or deformation.
Additional Precautions
• Use a reasonable amount of care when using the unit’s buttons, sliders, or other controls; and when using its jacks and connectors. Rough handling can lead to malfunctions.
• When disconnecting all cables, grasp the connector itself—never pull on the cable. This way you will avoid causing shorts, or damage to the cable’s internal elements.
• To prevent malfunction and equipment failure, always turn down the volume, and turn o all the units before making any connections.
Intellectual Property Right
• MMP (Moore Microprocessor Portfolio) refers to a patent portfolio concerned with microprocessor architecture, which was developed by Technology Properties Limited (TPL). Roland has licensed this technology from the TPL Group.
• This product contains eParts integrated software platform of eSOL Co.,Ltd. eParts is a trademark of eSOL Co., Ltd. in Japan.
• Roland is an either registered trademark or trademark of Roland Corporation in the United States and/or other countries.
• Company names and product names appearing in this document are registered trademarks or trademarks of their respective owners.
FEDERAL COMMUNICATIONS COMMISSION
RADIO FREQUENCY INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment requires shielded interface cables in order to meet FCC class B limit. Any unauthorized changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
For Canada
CAN ICES-3 (B)/NMB-3 (B)
For Korea
For C.A. US (Proposition 65)
WARNING
This product contains chemicals known to cause cancer, birth defects and other reproductive harm, including lead.
2036-1 Nakagawa, Hosoe-cho, Kita-ku, Hamamatsu, Shizuoka 431-1304, JAPAN
For EU Countries
DECLARATION OF CONFORMITY
Compliance Information Statement
Model Name :
Type of Equipment :
Responsible Party :
Address :
Telephone :
XI-MADI Audio Interface Module Roland Corporation U.S. 5100 S. Eastern Avenue Los Angeles, CA 90040-2938 (323) 890-3700