GLOBE FLOWCELL
Operating Manual
Rola-Chem Flowcell PN 550182 4/01/2013 page: 1 of 8
Table of Contents
Section title Page
1.0 Safety Instructions 2
2.0 Description 2
3.0 Installation 3
4.0 Use of Manifold 5
5.0 Maintenance 5
6.0 Trouble Shooting 5
7.0 Parts List 6
8.0 Warranty and Service 7
1.0
See controller manual for additional safety instructions.
A- WARNING: Do not shut down circulating and control system immediately after using pool, spa or hot
B- WARNING: Removing power from circulating pump must also remove power from the controller.
C- WARNING: Use a devise such as a flow switch to remove power from the controller in the event of
Safety Instruction
tub. Systems must operate until water chemistry is stable. Systems must be restarted before water
chemistry is out of NSPI recommended ranges or water chemistry must be manually corrected.
Provide a properly located outlet controlled by the circulating pump circuit.
pool pump or circulation failure. It is not safe to automatically dispensed chemicals into circulating
system that is not running.
2.0 Description
The manifold is designed to be used with a controller as part of a chemical automation system, which
continuously monitors and maintains pH balance and sanitizer level in a swimming pool or spa.
Rola-Chem Flowcell PN 550182 4/01/2013 page: 2 of 8
ORP PROBE
PROBE FITTING
FLOW SWITCH LEADS
FLOAT
(INSIDE CELL)
SHUT-OFF VALVE
pH PROBE
FILTER & SHUT-OFF VALVE
(OPTIONAL)
RECOMMENDED
GROUNDING STUD
BOTTOM VIEW
3.0 Installation
1. Mount Manifold:
Pre-mark hole locations for manifold mounting screws using the manifold. The manifold should not be above
the controller unit or other equipment or electrical devices. Manifold holes will accept #10 screws.
2. Install pH and ORP Probes:
Note: standard probes have platinum tips. Special gold tipped probes are recommended for application with
Salt Chlorine Generators.
Probe ends should not dry out. They are packaged within a jar to keep the ends wetted during shipment and
storage. Remove the probes from wetting jars by unscrewing the jar cap. Remove the jar cap and grommet
from the probe. (Save for future probe storage.) Close left and right manifold valves, and open the center
manifold valve.
Remove nuts from probe fittings and slide onto probes, noting direction of nut thread.
Insert the pH probe into the right probe receptacle. Probe should slide freely through the fitting and into the
manifold until it bottoms out inside the manifold. Then rais e the probe about 1/8", hold in position and fingerÂtighten the nut onto the fitting. Use a wrench to tighten the cap about another 1/4 turn.
DO NOT OVER TIGHTEN.
Repeat the procedure for the ORP probe in the left probe fitting.
Rola-Chem Flowcell PN 550182 4/01/2013 page: 3 of 8