Rokonet Orbit-6, RP-206 User Manual

Page 1
User Manual
1
USER MANUAL
VER. B
Page 2
2
User Manual
1. The ORBIT-6 (Model RP-206 ) complies with FCC Part 68 Rules. On the upper panel of this product is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN is 0.8B). If requested, this information must be provided to the Telephone Company.
2. An FCC compliant telephone connector is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a connector, which is Part 68 compliant.
3. If the ORBIT-6 (RP-206 ) is not operating properly, it may cause harm to the telephone network. If so, the Telephone Company will notify you in advance that a temporary discontinuance of service may be required. If advance notice is not practical, you will be notified as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if it is necessary.
4. The Telephone Company may make changes in its facilities, equipment, operations, or procedures, which could affect the operation of the equipment. If this happens, the Telephone Company will provide advance notice in order to enable you to make the necessary modifications to maintain uninterrupted service. If the equipment is causing harm to the telephone network, the Telephone Company may request that the equipment be disconnected until the problem is resolved.
5. Connection to telephone company-provided coin service is prohibited. Connection to party line service is subject to state tariffs.
6. If trouble is experienced with the ORBIT-6 (RP-206 ), for repair and warranty
information, please contact your supplier.
For service centers please see back cover.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced Radio/TV technician for help.
Changes or modifications to this unit not expressly approved by Rokonet, Ltd., could void the user's authority to operate the equipment.
p/n: 5IN206UM B
Page 3
User Manual
3
Copyright © 2000
by Rokonet Electronics Ltd.,
14 Hachoma Street
Rishon Letzion 75655
Israel
All rights reserved. No part of this document may be reproduced in any form without
prior written permission from the publisher.
Page 4
4
User Manual
Summary of User’s Commands
This User's Manual contains all the information needed to operate your Rokonet ORBIT-6 Security System and to get the most from it. This page, called a Command Summary, is intended to give you brief summaries of common system operations. More detailed explanations and related information can be found within, by referring to the indicated page.
FUNCTION PROCEDURE
MORE
ON
System Arming
[USER CODE] + [ARM] Page 19
Stay Home Arming
[USER CODE] + [STAY] Page 19
Instant Stay
[STAY] + [STAY] Page 19
System Disarming
[USER CODE] Page 22
Duress Disarming
[DURESS CODE] Page 23
Silencing an Alarm
[USER CODE] Page 22
Bypassing / Unbypassing a Zone
[ QQ] + [ 1] + [USER CODE ] + [ ZONE NUMBER TO BE BYPASSED / UNBYPASSED]
Page 20, 25
Quick Bypassing Zone
[ZONE NUMBER TO BE BYPASSED] for at least 2 seconds
Page 25
Reset Smoke Detector(s)
[ QQ ] + [ 2 ] + [USER CODE ] + [UTILITY OUTPUT NUMBER which is responsible for resetting the Smoke Detector]
Page 25
Utility Output Operation
[ QQ ] + [ 2 ] + [USER CODE ] + [ UTILITY OUTPUT NUMBER ]
Page 25
Display Troubles
[ QQ ] + [ 3 ]
Page 26, 29
Display Memory
[ QQ ] + [ 4 ] Page 26
Setting/Changing a User Code
[ QQ ] + [ 5 ] + [MASTER CODE] + [CODE NUMBER TO BE
SET/CHANGED] + [NEW CODE]
Page 17, 26
Set Date
[ QQ ] + [ 6 ] + [ 1 ] + [MASTER CODE] + [MM] [DD] [YY] Page 26
Set Time
[ QQ ] + [ 6 ] + [ 2 ] + [MASTER CODE] + [H][H] [M][M] Page 26
*Set Auto Arm Time
[ QQ ] + [ 6 ] + [ 3 ] + [MASTER CODE] + [H][H] [M][M] Page 26
Set Follow-Me Phone No. 1
[ QQ ] + [ 7 ] + [ 1 ] + [MASTER CODE] + Phone No. + [#] Page 27
Set Follow-Me Phone No. 2
[ QQ ] + [ 7 ] + [ 2 ] + [MASTER CODE] + Phone No. + [#] Page 27
**Set Follow-Me Phone No. 3
[ QQ ] + [ 7 ] + [ 3 ] + [MASTER CODE] + Phone No. + [ #] Page 27
**Set Follow-Me Phone No. 4
[ QQ ] + [ 7 ] + [ 4 ] + [MASTER CODE] + Phone No. + [ #] Page 27
Maintenance: On/Off Buzzer On/Off Door Chime *On/Off Audible Kiss-Off Indication
[ QQ ] + [ 8 ] + [MASTER CODE] + [ 1 ] [ QQ ] + [ 8 ] + [MASTER CODE] + [ 2 ] [ QQ ] + [ 8 ] + [MASTER CODE] + [ 3 ]
Page 28
Get Event From Event Logger
[ QQ ] + [ 9 ] + [MASTER CODE] + [EVENT NO.] Page 28
Test System
[ QQ ] + [ 0 ] + [MASTER CODE] Page 28
LED Trouble
1
Low Battery
2
AC Power Loss
3
Clock/Date Not Set
4
Communication Trouble
Trouble Table
5
Bell Loop Trouble
It is necessary to ARM your system
to obtain protection from intrusion.
All other forms of protection,
including fire and 24-hour panic alarms (i.e. police, fire, and special emergency) are always ready to
report alarms and do NOT need to be armed.
Page 5
User Manual
5
Table of Contents
SECTION 1: LET’S GET ACQUAINTED 7
Introduction 7
SOME DEFINITIONS 8
Zone 8 24-Hour Zone 8 Day Zone 8 Central Stations 8 Chimes 8 Trouble Reporting 8 Utility Outputs 8 Key-switch 8
SECTION 2: YOUR KEYPAD 9
Visual Indicators 9
Keys 11
SECTION 3: THINGS YOU SHOULD KNOW 13
ABOUT YOUR ORBIT-6 13
Arming Your System 13 Full Arming and Home Arming 14 Quick Arming and Code Arming 14 Entry/Exit Delays 14 Arming with the Front Door Open 14 Sounder Cutoff 14 The "Squawk" Feature 15 Follow-Me Feature 15 Voice Feature 15 Zone Bypassing 15 Duress Disarming 15 Quick Bypassing and Code Bypassing 15
SECTION 4: OPERATING YOUR SYSTEM 16
Emergency Keys 16
Police Emergency 16 Fire Emergency 16
Page 6
6
User Manual
Special Emergency 16
User Codes 16
Setting/CHANGING THE MASTER/USER CODES 17
Deleting User Codes 18
ARMING YOUR SYSTEM 19
BYPASSING A ZONE 20
Disarming an armed system 22 Silencing an alarm in progress 22
Duress Disarming 23
SECTION 5: SYSTEM SOUNDS 24
SECTION 6: USER FUNCTIONS 25
Zone Bypassing 25 Quick Bypassing 25 Extra Quick Bypassing 25 Activate a Utility Output 25 Reset a Smoke Detector(s) 25 Display System Troubles 26 Display Alarm Memory 26 Add, Modify, Delete User and Master Code(s) 26 Setting the Date 26 Setting the Time 26 Set Follow-Me Phone Number 1 27 Set Follow-Me Phone Number 2 27 Keypad Sounder/ Chime Operation 28 Event Logger 28 System Testing 28
SECTION 7: SYSTEM TROUBLES 29
Page 7
User Manual
7
Section 1: Let’s Get Acquainted
INTRODUCTION
Congratulations on your purchase of Rokonet’s ORBIT-6 Security System. The ORBIT-6 has been specifically designed to meet a wide range of security needs for many residential and small commercial applications.
You communicate with your ORBIT-6 through its
keypad(s)
. Using its keys, you can issue commands to your system. In turn, the system can communicate information to you via its indicators and by the sounds it makes.
Your ORBIT-6 security system also consists of a variety of
sensors, detectors
, and
contacts
placed throughout the premises and designed to recognize abnormal conditions. Typically, your system protects against
intrusion.
Some systems
may also have
fire
protection or
environmental
protection (such as gas or water level sensors) All of your system's detectors, sensors, and
contacts are wired to the
control panel
. As such, your system always knows the status of any protected door, window, hallway, room, or area. Similarly, it knows if a smoke detector has been activated.
The control panel, which contains the system's electronics and
backup battery
, functions in the background and, for purposes of security, is installed out of sight.
Page 8
8
User Manual
SOME DEFINITIONS
There are a few terms with which you should become familiar. Knowing them will help you to better understand and use your system
Zone
A single detector, or group of detectors, usually relating to a certain area of the premises or type of protection. Zones that use devices designed to detect break-ins, are called
intrusion zones
.
Another kind of zone may contain one or more
Smoke Detectors.
Such zones are called
fire
zones.
An
environmental zone
typically protects the premises from gas leaks and/or flooding.
24-Hour Zone
A
24-Hour
intrusion zone is
always
armed and is usually assigned to openings which should never be disturbed-like fixed glass and non-movable skylights.
Day Zone
A
Day Zone
is one in which a violation during the
disarmed
period results only in a keypad annunciation. However, the same violation during the armed period will cause a full-fledged alarm.
Central Stations
Besides producing audible alarms at your premises, it's likely that your system is set up to
Central Station–
continually monitors the activities of many security systems, usually via the telephone network, and
Chimes
The is a series of short keypad tones, which can be set up to annunciate, during the period, the violation of selected intrusion zone(s). The chime tone can be used to annunciate the
opens. The chime can be
disabled enabled
at
Trouble Reporting
If desired, your security system may also report to
troubles
or malfunctions it
Utility Outputs
In addition to your system's normal operation, it's premises lighting under the control of the ORBIT-
6—
where it can be conveniently turned on and off from any system keypad, or automatically activated in response to a system event.
Key-switch
Your system may also be equipped with a keyswitch, useful for simple arming and disarming operations - usually at a remote location.
Page 9
User Manual
9
Section 2: Your Keypad
VISUAL INDICATORS
The Orbit-6 can support 6 and 8 zone LED and LCD keypads. Both of these keypads have the same operating procedures. This section discusses the keypad's visual indicators and the use of its keys.
Each keypad in your system reports its status via its LED (lighted) indicators at the right. Through its keys, you can enter commands to "arm" and "disarm" the system, bypass intrusion zones, report emergencies, silence an alarm in progress–along with several other useful functions.
The four LED indicators found at the upper right provide typical system indications, as discussed below and on the next page. Some indicators have additional functions, explained later on.
POWER LED
CONDITION
(see note at left)
EXPLANATION
ON
The system is operating properly from commercial (AC) power; its backup battery is in good condition.
OFF
The system is inoperative due to the lack of power (from both commercial AC and backup battery); servicing will be required.
FLASHING
(disarmed
state)
Indicates a trouble condition; for more information on displaying and attending to trouble conditions, see pages 29 through 30.
The POWER LED is a useful indicator reflecting the system's operation.
NOTE: If a trouble condition exists, the POWER LED will flash only when the system is in its disarmed state. Once the system is armed, a previously flashing POWER LED will light steadily.
Page 10
10
User Manual
ARM LED
CONDITION EXPLANATION
ON
The system's intrusion detectors are armed; subsequent violations of a protected point or area (e.g. a door, a window, unauthorized motion) will result in a burglar alarm.
OFF
The intrusion function of the system is disarmed.
The ARM LED indicates whether or not the system's intrusion detectors are armed.
FLASHING
Occurs when using the emergency keys on the keypad to send panic, fire or special emergency alarm and also when viewing alarms after disarming.
READY LED
CONDITION EXPLANATION
ON
All intrusion zones are secure; the system is ready to be armed.
OFF
One or more intrusion zones are not secure and the system is not ready to be armed; before the system can be armed, the condition must be addressed (see pg. 20 through21).
The READY LED indicates whether or not the system's intrusion zones are secured and ready to be armed.
FLASHING
Indicates that one or more of the system's intrusion zones have been bypassed; for more information on bypassing (see pages 20 through
21).
FIRE LED
CONDITION EXPLANATION
ON
A fire alarm or fire emergency is in progress or has recently occurred.
OFF
All fire zones are operating
normally.
When lit, the FIRE LED indicates that the system is experiencing a fire alarm. When flashing, a problem has been detected on the fire circuit, and must be serviced.
FLASHING
A fault has been detected in the system's fire zone and needs to be corrected; for more information on fire zone trouble (see page 29).
Page 11
User Manual
11
ZONE LED
EXPLANATION
CONDITION
SYSTEM DISARMED SYSTEM ARMED
OFF
The corresponding zone is secured.
The corresponding zone is secured.
FLASHING
The indicated zone is
not secured.
N/A
The ZONE LEDs indicate the status of each of the system’s intrusion zones.
ON
N/A
An alarm has occurred on the indicated zone.
KEYS
The keys on the keypad can be used for a variety of functions. Each is explained below:
Used to input the numeric codes which may be required for arming, disarming, triggering emergency alarms, along with several other special functions.
Used to enter the User Functions mode (see pages 25 through 27).
Used to arm the system's intrusion detectors to the "AWAY" mode (see page 13); it may be necessary to enter a numeric
User Code
before pressing the Arm key (see pages 13 and 19 for additional information).
Used to arm the system's intrusion detectors to the "STAY" mode (see page 13); it may be necessary to enter a numeric
User Code
before pressing the Stay key (see pages 13 and 19 for additional information).
Page 12
12
User Manual
Page 13
User Manual
13
Section 3: Things You Should Know About Your ORBIT-6
Arming
Your System
Arming
your system enables its
intrusion
detectors
to trigger an alarm when violated.
Remember,
fire protection
and the protection
offered by the keypad's
emergency keys
are
always
armed and always available. If your system is equipped with environmental protection (e.g. gas and/or water level detection) it is always available too.
Secured or Bypassed:
Before you arm your system, all of its zones must either be secured or
bypassed
. The keypad's
READY
LED, if lit, indicates that all zones are
secured. If the
READY
LED is
not
lit, a numbered LED corresponding to the unsecured zone(s) will be flashing. Before you can arm your system, the indicated zone(s) must be identified and secured. If this is not possible, the affected zone(s) can be
bypassed
and will be ignored by the system during the subsequent armed period. Recall that bypassing, however necessary, reduces the system's degree of intrusion protection.
Page 14
14
User Manual
Full Arming and
Home Arming
Your
ORBIT-6
offers two kinds of system arming.
Full Arming
prepares
all
of the system's intrusion detectors to sound an alarm, if violated. It is most often used when the premises will be empty. Home Arming (or Stay Arming) allows individuals to remain inside and move about the premises even after the system is armed.
Home Arming
arms the
perimeter
detectors (e.g. door and
windows), while leaving
interior
detectors (e.g.
motion detectors) disarmed (bypassed).
Quick Arming and
Code Arming
Your
ORBIT-6
also offers two
methods
of arming.
Quick Arming
achieves the result with just the
press of a single key (either or ).
Code Arming
requires that a valid
Master Code
or
User Code
be entered first. Whether or not your
system permits
Quick Arming
was determined
during its installation.
Entry/Exit Delays
Your security system must incorporate an
Entry/Exit Delay
to allow proper entry and exit to and from the premises without causing inadvertent alarms. A delay period was chosen during your system's installation to provide suitable time to allow for your entry and exit.
Arming with the
Front Door Open
If set up by your alarm company, the
ORBIT-6
allows you the convenience of arming your system with the front door either closed or open, after which you must close the door as you leave the premises before the exit delay period expires. With such a door open (and all other zones secure), the system is considered "ready to arm"; the Zone LED corresponding to the opened door will be lit, as will your keypad's READY LED.
Sounder Cutoff
It's likely that your security system was installed with a sounding device (e.g. a siren or a bell). Typically, all sounding devices have cutoffs; that is, they will shut off after a predetermined interval (usually several minutes) set by your alarm company. In many locales, this is required by law. Once a sounder shuts off, it is still capable of responding to a subsequent alarm during the same armed period.
Panic Button
A special panic button can be installed at any preferred location, to allow immediate and flexible alarm notification in time of distress.
Page 15
User Manual
15
The "Squawk"
Feature
A feature known as
Bell Squawk
is available for your system. If selected by your alarm company, the
Bell Squawk
causes the system's external sounder (either a siren or a bell) to produce a momentary "beep" as follows:
One beep: At the conclusion of the
Exit Delay
, confirming that the system has been successfully armed.
Two beeps: Confirming that the system has been disarmed .
Four beeps: Confirming that the system has been disarmed after an alarm has occurred.
Follow-Me Feature
In case of an alarm event a phone call can be made to a predefined phone number. There are three different tone types that represent burglary, fire and special emergency alarms. The Follow-Me function can support two phone numbers.
Voice Feature
An optional Voice Module can be added to your system. Up to 3 short messages can be recorded. These messages replace the alarm tones normally produced in the follow-me mode.
Zone Bypassing
It may be convenient to have one (or more) of the zones in your installation
bypassed–
and thus
ignored by your system.
Duress Disarming
If you are ever coerced into disarming your system, you can comply with the intruder's wishes while sending a
silent, duress alarm,
to the Central
Station. To do so, you must use a special
Duress Code
. Which when used, will disarm the
system in the regular manner, while simultaneously
transmitting a silent alarm to the central station.
Quick Bypassing
and
Code Bypassing
Your Orbit-6 offers two methods of Bypassing:
Quick Bypassing
achieves the result by pressing the key number corresponding to the zone to be bypassed for 2 seconds.
Code Bypassing
requires a valid Master Code or
User Code to be entered first. Whether or not your system permits Quick
Bypassing was determined during its installation.
Page 16
16
User Manual
Section 4: Operating Your System
In this section, you'll learn how to perform most of the functions needed to properly operate your ORBIT-6 and to get the most out of your security system.
EMERGENCY KEYS
Your keypad provides three sets of keys, which can be pushed at any time the police, fire department, or special emergency is required.
Panic Key
Pressing and
simultaneously, and
for at least two seconds, will activate a
Panic Key alarm.
Fire Emergency
Pressing and simultaneously, and for at least two seconds, will activate a
Fire Emergency alarm.
Special Emergency
Pressing and simultaneously, and for at least two seconds, will activate a Special Emergency alarm.
The annunciation that results during these emergency alarms, along with other system sounds, is covered in Section 5.
USER CODES
To perform many of the ORBIT-6's functions, a four-digit
security code
(often called a
User
Code
) must be entered at the keypad. In residential systems, it's likely that all family members will share the same User Code. In certain commercial systems, however, it's common to give each authorized employee his/her own User Code (discussed on page 17). Your
ORBIT-6
permits up to ten User Codes.
One of the codes is considered the
Master
Code
; the individual(s) using the
Master Code
is given the following special privileges:
•• adding, modifying, and deleting User
Codes
•• setting the system's internal clock
•• performing certain system functions and
tests
Except for these considerations, the
Master Code
and any
User Codes
assigned to the system operate identically. Your
ORBIT-6
was given a
Master Code
of 1–2–3–4 during manufacturing. Unless your alarm company has already changed it to suit your preference, it's best to modify this code to one which is unique and personalized. To change the
Master Code,
and/or to set up
User
Codes, follow the steps on page 17.
Page 17
User Manual
17
SETTING/CHANGING THE MASTER/USER CODES
STEP DESCRIPTION
1
The system must be disarmed (the ARMED LED will be
OFF). Enter the User Functions Mode ( ) and select Codes (5):
2
Enter the current 4-digit Master Code:
3
To change the Master Code, press "0":
To enter/change the User Code 1, press "1":
To enter/change the User Code 2, press "2":
To enter/change the User Code 3, press "3":
It is possible to enter/change up to 9 User Codes.
4
Enter the new 4-digit code selected for the Master Code or for the User Code of your choice:
5
If successful, the keypad will emit a one-second confirming tone. The selected User Code is now in effect.
Example: To change the Master Code 1234 to a new code 7890, press the following keys: [Q][5] [1] [2] [3] [4] [0] [7] [8] [9] [0]
14243 14243 1442443 Master Code Code I.D. New Code to be changed
Page 18
18
User Manual
DELETING USER CODES
At times, it may be desirable to completely delete a User Code. Note that it is impossible to delete the Master Code (although it can be changed).
STEP DESCRIPTION
1
The system must be disarmed. Enter the User Functions Mode ( ) and choose Codes (5):
2
Enter the current 4-digit Master Code:
3
To delete the User Code 1, press "1":
To delete the User Code 2, press "2":
To delete the User Code 3, press "3":
4
Enter 0-0-0-0 (which is NOT a valid code) to clear the selected User Code.
5
If successful, the keypad will emit a one-second confirming tone. The selected User Code is now deleted.
Page 19
User Manual
19
ARMING YOUR SYSTEM
STEP DESCRIPTION
1
Check the READY LED on your keypad. If lit or flashing, the system is READY.
If NOT lit or flashing, the system is NOT ready to be armed. Secure or bypass the violated zone(s) and then proceed.
Away
Arming
2
Arming when Leaving the Premises Empty:
Enter the four digits of your User Code and press .
NOTE: If you make a mistake when entering your User Code, the keypad will produce three short beeps. If so, re­enter the above sequence correctly.
If your system has Quick Arming, simply press
3
Leave the premises and close the door. The keypad will beep as counts down the Exit Delay period.
Stay
Arming
2
Arming with the Premises Occupied Enter the four digits of your User Code and press
.
NOTE: If you make a mistake when entering your User Code, the keypad will produce three short beeps. If so, re­enter the above sequence correctly.
If your system has Quick Arming, simply press .
3
If required, leave the premises and close the door. The keypad will beep as it counts down the Exit Delay period. The internal zones will be automatically bypassed.
Note: By pressing (twice) the system will silence the beeps on
the keypad and cancel the entry delay time. By pressing during exit time will silence the beeps on the
keypad.
Page 20
20
User Manual
BYPASSING A ZONE
STEP DESCRIPTION
1
Check the READY LED on your keypad. If NOT lit or flashing, the system has at least one faulted intrusion zone identified by noting which LED(s) are flashing in the keypad's ZONES area, shown at the left.
Code
Bypassing
2
To bypass such a zone(s) and cause it to be ignored by the system, enter the following sequence correctly:
NOTE: If you make a mistake when entering your User Code, the keypad will produce three short beeps. Re-enter if necessary.
An additional zone(s) can be bypassed at the same time by adding its number to the sequence. For example, to bypass Zones 2 and 3, press:
[
] + [ 1 ] + [USER CODE] + [ 2 ] + [ 3 ]
The same sequence can “toggle” the bypass(es) during the disarmed period so that they may be either applied or
removed.
Press # or Q to approve or wait 2 seconds (timeout period).
Page 21
User Manual
21
BYPASSING A ZONE (CONT.)
If the system is programmed for quick bypass the following option is available:
Quick
Bypass
2
To bypass a zone simply press the corresponding keypad number for at least 2 seconds.
An additional zone(s) can be bypassed at the same time by adding its number to the sequence. For example, to bypass Zones 2 and 3, press:
[ 2 ] for 2 seconds + [ 3 ]
The same sequence can “toggle” the bypass(es) during the disarmed period so that they may be either applied or removed.
3
The READY LED, when flashing, indicates that there is one or more bypassed zones. Any zone(s) bypassed during the disarmed period will remain bypased when the system is armed.
Zone(s) that are bypassed, during the time the system is armed, will automatically be restored to its normal, unbypassed condition, when the system is disarmed.
DETERMINING WHICH ZONE(S) IS BYPASSED
STEP DESCRIPTION
1
The system must be disarmed. If the keypad’s READY LED is flashing, there is at least one bypassed zone, in the system. To determine which zone is bypassed, follow this sequence:
If quick bypass is enabled in your system, simply press:
2
Observe the keypad’s ZONES area. LED(s) corresponding to the bypassed zone(s) will light for several seconds.
Page 22
22
User Manual
DISARMING AN ARMED SYSTEM AND/OR SILENCING AN ALARM IN PROGRESS
STEP DESCRIPTION
1
If outside the premises, open an "entry" door; the keypad(s) will beep indicating that the Entry Delay period has begun.
2
Disarming an armed system
Before the Entry Delay expires, enter the four digits of your User Code.
NOTE: If you make a mistake when entering your User Code, the keypad will produce three short beeps. If so, re-enter the above sequence correctly.
2
Silencing an alarm in progress
Observe the keypad. If any of the following conditions is evident, an alarm has occurred:
· the ARM LED is flashing
· a Zone LED is lit steadily
· the FIRE LED is lit steadily Disarm the system by entering your User Code:
It's best to enter the premises only after police or a security company has investigated and you feel confident that the burglar is no longer on your premises.
3
IMPORTANT! If the alarm was caused by a tripped Smoke Detector(s), the
keypad's FIRE LED will remain lit—providing an indication that the fire system must be reset before it will be capable of detecting subsequent alarms. Furthermore, until reset, you will be prevented from arming your system. To reset the fire system and to turn off the FIRE LED, refer to Activate a Utility Output/Reset Smoke Detectors, in the table on page 25.
Page 23
User Manual
23
DURESS DISARMING
All 10 user codes can activate the Duress disarming by adding 1 to the last digit of your user code.
Example:
if your code is 1-2-3-4 your duress code is 1-2­3-5
If your user code is 5-6-7-0 your duress code is 5-6-7-1
Note: Under no circumstances must the Duress
Code be used haphazardly or without reason.
Central Stations, along with Police
Departments, treat Duress Codes very
seriously and take immediate action.
DISARMING BY USING THE DURESS CODE
STEP DESCRIPTION
1
If outside the premises, open an "entry" door. The keypad(s) will beep indicating that the Entry Delay period has begun.
2
Enter your 4-digit Duress Code:
A utility output in your system may be programmed to be activated continuously after an entry of the duress code. If so, deactivation must be done manually by one of the following procedures:
1. Arming the system.
2. Disarming the system after an alarm that occurred while the utility output was still activated.
Page 24
24
User Manual
Section 5: System Sounds
Besides the visual indications provided by your keypad(s), your system is designed to produce audible annunciation after certain events. Depending on the circumstance, such sounds may be made by your system's keypad(s), its external sounder (e.g. a siren or bell),
EVENT KEYPAD SOUND
SIREN/
BELL
Intrusion Alarm
MAYBE
(see Note 5)
YES
(continuous)
Fire Alarm
Rapidly repeating tones (see Note 3)
YES
(staggered)
Keypad Police Emergency
A momentary chirp
OPTIONAL
(see Note 2)
Keypad Fire Emergency
Rapidly repeating tones (see Note 3)
YES
Keypad Special Emergency
A momentary chirp
no sound
Arming or disarming
A one second tone if completed correctly; three rapid error beeps if incorrect (see Note 3)
no sound
Entering an incorrect key sequence
Three rapid beeps
(see Note 3)
no sound
Entry Delay countdown
Slowly repeating tones until the entry delay period expires (see Note
3)
no sound
Exit Delay countdown
Slowly repeating tones until the exit delay period expires (see Note
3)
OPTIONAL
(see Note 1)
NOTE 1:
If selected during the installation, a brief "chirp" may be heard from the siren when the Exit Delay period expires. See page 14 for additional information.
NOTE 2:
Whether or not the Police Emergency alarm is annunciated by the external sounder is determined by the alarm company during your system's installation.
NOTE 3:
Keypad beeps in response to Entry/Exit Delay countdowns, Keypad Fire Emergencies, and keypad errors and confirmations are typically enabled. At the user's discretion, such beeps may be disabled. See page 14 for additional information.
NOTE 4:
Any intrusion zone, if selected for the chime feature, will, when violated during the disarmed period, cause the keypad to annunciate the event (see page 8). Through User Functions (see page 27), the chime can also be disabled when not desired.
NOTE 5:
Based on decisions made at the time your alarm system was installed, keypad(s) may beep during this type of alarm.
Entering data into the User
Functions
mode
(see page 25)
A one second tone if completed correctly; three rapid error beeps if incorrect (see Note 3)
no sound
Page 25
User Manual
25
0
Section 6: User Functions
Your ORBIT-6 comes with a variety of selectable
User Functions.
By entering
the
User Functions
mode, a number of options become available which
determine how your alarm system operates, such as:
adding, modifying, and deleting User Codes
bypassing zones
displaying a "memory" of previous alarms
displaying system troubles
disabling (and re-enabling) keypad sounds
setting the system's internal clock, time and date
•• performing certain system tests Among these
User Functions
are some which have already been covered. As
required, each will be explained below.
USER
FUNCTION
DESCRIPTION PRESS COMMENTS
Zone Bypassing
+
+ USER CODE
+
(zone number to be
bypassed or unbypassed)
Quick Bypassing
+
+
(zone number to be
bypassed or unbypassed)
Extra Quick Bypassing
To bypass or unbypass a selected zone(s)
for at least 2 sec. (zone number to be
bypassed or unbypassed)
Refer to
Zone Bypassing
procedures, already discussed on page 20.
Activate a Utility Output
To activate or de­activate a Utility Output
+
+ USER CODE
+
(Utility Output number
to be activated or
deactivated)
Refer to
Utility Outputs
on page 8; also consult your security dealer.
Reset a Smoke Detector(s)
To reset a Smoke Detector
+
+ USER CODE
+
(Utility Output number
responsible for resetting
the Smoke Detector(s)
Refer to
System Troubles
on page 29; also consult your security dealer.
Page 26
26
User Manual
USER
FUNCTION
DESCRIPTION PRESS COMMENTS
Display System Troubles
Display system problem(s) causing the POWER LED to flash
+
Refer to
System Troubles on
page 29.
Display Alarm Memory
Reviews any alarms occurring during the last armed period
+
Via its LEDs, the keypad reveals the zone(s) in which an alarm occurred during the previously-armed period.
After several seconds, the LEDs will restore to normal.
Add, Modify, Delete User and Master Code(s)
+
+ MASTER CODE
+
(number of the Code to be added, modified, or deleted)
+
(the new 4-digit code)
NOTE: Use 0-0-0-0 to delete the Code.
Refer to Setting /
Changing Master /
User Codes,
discussed on page 17.
Setting the Date
Set the systems date
+
+ MASTER CODE
+ + +
To enter date as: MM DD YY
MM: month 1-12 DD: Day 1-31 Year: 00-99
Setting the Time
Sets the system’s internal clock
+
+ MASTER CODE
+
enter time in HH:MM format
Use 24-Hour format, as in these examples:
for 12:30 AM, enter 0030
for 8:45 AM, enter 0845
for 6:15 PM, enter 1815
the clock must be set to insure proper system operation.
Setting the Auto Arm
+
+ MASTER CODE
+
enter time in HH:MM format
Use 24-Hour format.
D
Y
Y
D
Page 27
User Manual
27
USER
FUNCTION
DESCRIPTION PRESS COMMENTS
Set Follow­Me Phone Number 1- 4
Sets the first phone number for the follow-me function (up to 24 digits)
+ or
+
or + or +
+ MASTER CODE
+ Phone Number + [#]
Enter the phone number in the same manner as MS number during installation.
* If required, include the following special functions to achieve the effect listed in the table:
FUNCTION
SEQUENCE RESULTS stop dialing and wait for a new dial tone [STAY], [1] A wait a fixed period before continuing [STAY], [2] B switch from Pulse to Tone (or from Tone to Pulse)
[STAY], [3] C
send the DTMF Q character
[STAY], [*]
*
send the DTMF # character [STAY], [#] #
Page 28
28
User Manual
USER
FUNCTION
DESCRIPTION PRESS COMMENTS
Keypad Sounder/ Chime Operation/ Audible Kiss-Off Indication
Determines how the keypad's internal sounder will operate under specific conditions
+
+ MASTER CODE
+ / OR
+ / OR
After entering the Master Code, press to enable/disable current operation of keypad's beeps (see Note 3 on page 24) .
Press to disable/enable the "chime" for intrusion zones having this feature (see page 8).
Press to disable/enable the Audible Kiss-Off Indication.
Event Logger
Retrieves events located in the event logger memory (up to 99 events).
+
+ MASTER CODE
+ Event Number
The event number is represented by the zone LEDs (events are presented from the last entered to the first registered).
System Testing
Provides a brief test of the following:
· keypad LEDs
· keypad sounder
· external siren
· standby battery
+
+ MASTER CODE
The external sounder will be activated momentarily.
The keypad's LEDs will flash.
If enabled, the keypad's sounder will beep.
A low battery (see pages 8 and 29) or a loss of commercial power will cause the POWER LED to flash; if so, consult your security dealer.
Page 29
User Manual
29
Section 7: System Troubles
Your
ORBIT-6
is designed to report any
troubles
or malfunctions it may detect. Notification that a problem exists is made to the user, through indications on the keypad(s) and, in many cases, to the Central Station and to your dealer. Any incidence of trouble should be taken seriously and acted upon immediately. If not remedied quickly, a trouble condition will likely compromise your system and prevent it from properly doing its job.
The ORBIT-6 is designed to be as trouble-free as possible. Were a problem to develop, the
POWER
LED will flash about once every second. If so, to
determine the problem, perform the sequence on the following page. In certain cases, the keypad's FIRE LED may remain lit steadily, even though
there is no alarm in progress and the system is disarmed. Refer to the explanation and remedy below:
USER FUNCTION DESCRIPTION AND REMEDY
the FIRE LED
remains lit
After a fire alarm has occurred and been silenced, the keypad's red FIRE LED will remain lit steadily if a Smoke Detector (presumably the one which caused the alarm) remains tripped. Until reset, a tripped Smoke Detector will prevent the READY LED from being lit, and will NOT permit the system to be armed.
To reset a tripped Smoke detector and to extinguish the red FIRE LED, follow this procedure, which is typical:
+
+ USER CODE
+
64444744448
UTILITY OUTPUT NUMBER
(which is responsible for resetting the Smoke Detector)
Consult your security dealer for alternate information on resetting smoke detectors, if applicable.
Once done, the READY LED will indicate the system's status and you will be able to arm your system.
Page 30
30
User Manual
IDENTIFYING SYSTEM TROUBLES
STEP DESCRIPTION
1
Perform if the POWER LED is flashing. If lit steadily, there are no system troubles. To view trouble conditions, the system must be disarmed. Enter the User Functions Mode by pressing [ ] and then select View Troubles (3):
2
The keypad will beep and its LEDs will light, reflecting the information below. After several seconds, the display will return to normal.
FLASHING: Trouble Detected OFF:
(normal in this mode)
OFF:
(normal in this mode)
IF ON: Fire Zone Trouble
(contact your dealer)
IF ON: Low Battery (contact dealer) IF ON: AC Power Loss (see Note 1)
IF ON: Clock, Time & Date Not Set
(see page 19)
IF ON: Communications Trouble
(see Note 2)
3
IF ON: Bell Loop Trouble
(see Note 3)
In an 8 zone keypad there are 2 more LEDs which are only zone indicators and not system indicators.
NOTE 1: Check that the ORBIT-6's Plug-In Transformer has not been removed from its outlet. If intact, check that a blown fuse, a switch, or a tripped circuit breaker has not interrupted the circuit supplying power to the transformer. NOTE 2: The ORBIT-6 has failed in its attempts to report an alarm or trouble condition to the Central Station. Check that your telephone line is functioning. Check to see if your external bell has been tampered with. If the problem still exists contact your dealer.
NOTE 3: The ORBIT-6 has failed in its attempt to identify the Bell Loop.
It is possible for more than one trouble to be present at the same time. If so, multiple Zone LEDs will be lit simultaneously.
Page 31
User Manual
31
EMERGENCY EVACUATION PLANS
An emergency evacuation plan should be established and used during an actual fire alarm condition. The following steps are recommended by the National Fire Protection Association (NFPA) and can be used as a guide when establishing a similar plan for your circumstances.
1. Draw a floor plan of your premises showing windows, doors, stairs, and rooftops, which can be used for escape. An example has been provided below.
2. Indicate each occupant's escape routes by determining two means of flight from each room. One should be the normal exit from the building, while the other may be a window that opens easily, or another alternate route. An escape ladder may have to be located near an escape window if there is a long drop to the ground below. Always keep escape routes free from obstruction.
3. Practice escape procedures and set a meeting place outdoors for a headcount of the building's occupants.
4. In a home, sleep with the bedroom door closed to increase your escape time. If a fire is suspected, first test the door for heat. If you think it is safe, brace your shoulder against the door and open it cautiously. Be ready to slam the door if smoke and heat rush in.
5. After escaping from a fire, call the Fire Department from a neighbor's phone.
After the installation of your Security System has been completed, notify your local Fire and Police Departments to give them your name and address for their records. Early warning fire detection is best achieved by the installation of fire detection devices in all rooms. This equipment should be installed in accordance with the
National Fire
Protection Association's
Standard 72.
For additional information, write to the
National Fire Protection Association
(NFPA) at Batterymarch Park, Quincy, MA 02289.
Page 32
32
User Manual
Notes
Loading...