WELCOME
Dear Customer,
Thank you for choosing the SYGMA digital electric towel rail, with an exclusive electronic temperature programmer and made with the highest quality materials especially for you.
The SYGMA digital electric towel rail have exceeded the most stringent quality controls in order to comply with the most rigorous requirements for safety.
Before using the SYGMA digital electric towel rail, we recommend that you read this instruction manual in order to ensure correct operation.
IMPORTANT
THIS MANUAL SHOULD BE LEFT WITH THE PRODUCT AFTER
INSTALLATION
3
TABLE OF CONTENTS
1. DESCRIPTION OF THE SYGMA TOWEL RAIL .............................. 4
1.1. Front Panel Parts ................................................................. 4
1.2. Switching On & Off (stand-by) .............................................. 5
1.3. Setting the day and time ....................................................... 6
1.4. Locking the Control Panel .................................................... 7
1.5. Temperature Selection ......................................................... 7
1.6. Manual/Automatic Mode ...................................................... 7
1.7. Two-hour Boost Mode (2H) ................................................... 8
1.8. Open windows function ......................................................... 8
1.9. Screen brightness function .................................................. 9
2. PROGRAMMING THE SYGMA TOWEL RAIL .............................. 10
3. MOUNTING INSTRUCTIONS ..................................................... 12
4. CONNECTING INSTRUCTIONS ................................................. 13
4.1. SYGMA Towel Rail Technical Characteristics .................... 15
4.2. Specific Regulations for Bathrooms .................................. 17
5. MAINTENANCE & CLEANING ................................................... 17
5.1. Safety .................................................................................. 18
6. GUARANTEE .............................................................................. 18
ENGLISH
ATTENTION:
If you are the owner of a model bought in the UK or Éire, please refer
ONLY to its manual as the specifications of the towel rails are different.
4
SYGMA
TFT DISPLAY
CONTROL PANEL
1. DESCRIPTION OF THE SYGMA TOWEL RAIL
1.1. Front panel parts
5
1.1.1. TFT display symbols
SEGMENT INDICATION
1 PROGRAMMING 2 DAYS OF THE WEEK 3 TIME OF DAY 4 TEMPERATURE SELECTED 5 OPEN WINDOW FUNCTION 6 TOWEL RAIL HEATING 7 MANUAL / AUTOMATIC FUNCTION 8 COMFORT / ECO / ANTI-FROST MODE 9 LOCKING THE CONTROL PANEL
1.2. Switching On & Off (stand-by)
By pressing the key , we switch the towel rail on or off. The following
3
7
4
2
5
6
1
9
8
6
SYGMA
image will appear on the screen when switched on:
The screen will automatically go into sleep mode if no button is pushed for 10 seconds. By pushing the button again the towel rail will go into standby mode with the word “Standby” appearing followed by the Rointe logo.
1.3. Setting the day and time
In order to adjust the time and day of the week, please follow the steps below. First we choose the hour, then the minutes, then the day of the week.
To enter the time and day adjust mode, press and hold the button for 3 seconds.The hours will start flashing.
Select the hour using the and buttons to move the hour up or down. Press once and the minutes will start to flash.
In the same way as with the hours, use and to increase or decrease the minutes to select the correct time.
Once the minutes are correct press again so that the day flashes.
This represents Monday. With the button we can advance through to day 2 (Tuesday), day 3 (Wednesday), etc. until we reach the required day. Press again to confirm the day and to leave the time and date adjust mode.
7
1.4. Locking the Control Panel
By pressing the keys and at the same time for 3 seconds, we lock the control panel. The control panel symbol is activated and the keys will not respond when pressed. If one key is pressed this image will appear in the screen of the towel rail:
To unlock, press the and keys again, at the same time for 3 seconds.
1.5. Temperature Selection
By pressing or we change the temperature. When the room temperature is lower than the set temperature, the electric towel rail will begin to generate heat and the symbol will appear.
1.6. Manual / Automatic Mode
By pressing we change between the Manual and Automatic mode. When the manual mode is selected, the symbol appears on the display. When the automatic mode is selected, the symbol appears on the display.
1.6.1. Manual Mode
This enables you to choose between the CONFORT, ECO and ANTI-FROST modes of operation, changing the temperature as indicated in Section 1.5.
ICON MODE TEMPERATURE RANGE
COMFORT 20ºC - 30ºC
ECO 15ºC - 19,5ºC
ANTI-FROST 8ºC
8
SYGMA
1.6.2. Automatic mode
This mode activates the programming set on the heated towel rail.
1.7. Two-hour Boost Mode (2H)
By pressing the key , the heated towel rail will work for two hours at maximum power, regardless of any other mode. This mode takes priority over any other.
When the heated towel rail is set on the two-hour mode, the screen will show this image: for a few seconds.
Once the towel rail is set on the two-hour mode, and until the two hours have finished or the key is pressed again, the display will show this image:
1.8. “Open Window” function
This function is activated when the sensor detects a reduction of 4ºC in respect of the set temperature during 30 minutes.
On activation, the following image will appear on the towel rail display for 5 seconds:
When the “Open Window” function is activated, the following screen