1. Product description
This product is a non-contact infrared thermometer that professionally measures the temperature of the human body. It uses imported high­performance sensors to detect subtle temperature changes. The backlight color and numerical display functions are very easy to make the user clear Distinguish the temperature value, the big screen display is simple and easy to understand, it only takes one second You can measure your body temperature, this is a high-tech product you can trust
2. Basic principles
When the temperature of all objects is higher than absolute zero, a certain amount of infrared energy will be radiated. The value of infrared energy radiated by different types of objects is different, but the surface temperature of such objects can be judged according to the radiated infrared energy and wavelength value
According to this principle, the temperature of the forehead can be accurately measured due to the relatively constant temperature. Since the infrared intensity radiated from the forehead at the same tempera­ture is different from other objects, such as the infrared energy radiated from water, there are at least two measurement modes (body tempera­ture mode and object temperature mode). The temperature mode is based on the temperature of pure water, so when you are measuring other objects, there may be some errors depending on the properties of the objects, which is normal
3. Product features
●Non-contact high-precision measurement, clean and hygienic
●Using imported infrared sensor to ensure that the test is very accurate
●The patented software design technology ensures that the test is very stable
●Excellent adaptability to env ironmental changes, can be used in complex environments
●Numerical display function, simple and clear reading results
●The temperature unit can be adjusted to Celsius or Fahrenheit, which is convenient for different users
●Alarm value can be set (the default value of this product is 37.5°C)
● Automatic shutdown function. Automatic shutdown without operation within 20 seconds
4. Precautions
In order to obtain stable and reliable measurement data, when the temperature changes greatly, the human body infrared measuring instrument should be placed indoors for 30 minutes before use. The measured temperature will be different according to the skin color, thickness and body parts of the person . This is quite normal. The more exposed the human body part is, the more it is affected by the ambient temperature.
Do not expose this product to the sun, and do not touch water or other liquids
5. Tips for use
●Please read this manual ca refully before use.
●The ambient temperature of this pro duct is 0 °C to 50°C, the b est temperature is 25.
●Do not use this p roduct in an environment h igher than 40°C or lower than 10°C.
●Do not place the p roduct near live objects to avoid electric shock.
●Do not use this p roduct in an environment wh ere the relative t emperature is greater than 85%.
●Do not put this p roduct too close to the electromagnetic range (such as radio, mobile phone, etc.).
●Please do not expose th is product to the sun or near the stove, let alone contact with water.
● Please d o not hit or drop this p roduct, p lease do not use it if it is damaged.
●Hair on the forehead, swe at, hat or scarf will a ffect the accuracy o f the measurement data.
●Please confirm that the me asuring distance is not greater than 10cm.
●In order to obtain a ccurate, stable and re liable measurement data, when the room temperature changes gre atly Put the thermometer at roo m temperature for 30 minu tes before use.
●Forehead sweating or o ther reasons cause the forehead t emperature to not reflect the body temperature normally Measure after hanging down.
●When cleaning is re quired, please gently wipe the surface of the instrument with alcohol.
●If there is a p roblem with the product, ple ase contact the d istributor, do not try to repair it yo urself.
●Please place this product out of the reach of childrent
GP-100 Software User Guide
This software only supports windows system
1. Turn on the top switch of the thermometer, use th e data cable to connect with the USB interface of th e computer, and install the USB serial port driver.
°C/°F
Note: The driver is usually installed automatically If you encounter an installation failure, you need to manually install the USB driver. The software package contains part of the program dependent filesChanges will cause errors in the program. Please check the following instructions carefully
2. O peration process
(1) Open the software package folder, and then double-click the program. exe icon.
(2) When opening the software for the first time, select the "COM1" interface and click Connect Device
(3) "F ail"will change to"success
Fail
Success
Completing this step means normal connection, then temperature measurement data can be imported into the computer in real time
Note:
1. O pen the software, it will automatically find the COMport, if the COM port displayed by the software is different from the computer resource manager, it will not work properly,please manually set the serial port to the corresponding serial port of the resource manager.
2. After the thermometer is turned off and then on againyou need to click "Disconnect"and then click"Connect to display success to run normally, or closethe software land open the software again, This step is to refresh the connected serial port and the data will be continued Otherwise it wi ll be impossible to read the data.
3.
Data viewing and export
1. [Text Data View The "Quantity, Time, Measured Temperature, Environmental Temperature"data that will be generated after using the thermometer, the folder "This computer\\ Doc"will be automaticall generated in the software package by YearMonth Day sequence recording, the format is"TXT t ext
2. Excel Data View"Save"on the software panel and select" TXT format"to export .
4. So ftware Introduction
(1) Software name: GP-100APP
Success
This part is mainly to establish a communication relationship with the infrared thermometer so that the software can normally receive the temperature data measured by the infrared thermometer. If the communication is normal: display success, otherwise fail
(2) W hen the software just opened and not (3)When the measured temperature is displayed,
received the data s ent by the infrared normal"is disp layed under normal conditions If it thermometer, "36.5°C" will be displayed exceeds a certain upper limit value,abnorm al
will be displayed
(4) )Display Chinese interface (6)Record the measured temperature data of
the day, includ ing the meas ured quantity, the test time and the measured temperature corresponding to each measurement object
(5) Dis play English interface
(7)The default data is saved in the current path, the user can use this button to save the data of the day, you can re-select the path and set the file name, the suffix can choose .txt or. csv Save As
1.Introduction
3.Status Description
1. S tandby: Th e red dot in the bottom of the d isplay lights up in turn. (Fig. 1)
2. N ormal temperature: Flashing green lights and alarm “Di”. (Fig. 2)
(2)Mode: Long press Unit switch for 3 seconds to switch the temperature
measurement mode (Sur: surface mode, boy: body mode, Cou: counting mode)
(8)Set the upper limit of the alarm, when the measured temperature exceeds this value, the infrared thermometer will give an alarm prompt
Medical Infrared Thermometer
User Guide
USB interface
Tripod mounting hole
Switch
3. Abnormal temperature: Flashing red lights and alarm“DiDi Di DiDi” (Fig. 4)
4. D efault(boy: body mode Lo: Ultra-low temperatur e( Fig. 5) HI: Ultra-high temp erature alarm (Fig. 6)
3.Install and replace battery (1)Remove three screws (2)Open the back base and install 18650 Li battery
Double-sided adhesive area
Infrared thermometer
Infrared ranging sensor
Temperature display
Hanging hole
4.Install method
Nampelate
4.Operation lnstruction
Unit switch
1. Temperature measurement: the front of the thermometer, and within 10-15 cm ( the best measurement distance) (Fig. 7)
Alarm light
2.Specification
1.Nail hook
2.Bracket f ixing
3.Double-sided adhesive stick ing
(11)Display specific measurement time of the day and the environm ent temperatu re
1. C ounting capacity: 999
2. Abnormal automatic alarm: flashing+DiDi"sound
3. Automatic measurement: measuring distance 5cm- 10cm
4. S creen: Digital display
5. C harging method: USB charging or battery(18650 Li-ion)
6. In stall me thod: nail hook , doub le-sided adhesive stick ing, bracketfixing
7. E nvironment temperature: 10°C-40°C(Recommended 15°C-35°C) Infrared measuring ran ge: 0-50 °C
8. R esponse time: 0.5s
9. In put: DC 5V
10. Net weight: 263g
11. Standby: About one week
12. Accuracy: +0.2 degrees (34-45 °C, place it in the operating enviro nment for 30
minutes before use)
Warning
5. F AQ
1. Q: Can't open the serial port?
A: W rong selection of CO M port. Solution: Connect the USB cable before opening the software, so that it will automatically recognize the port number) B: The USB driver is not updated. Solution: Connect to the network, right-click on my computer, open the resourc e manager, and update the driver
2. Q: The data is not refreshed after the serial port is opened
A: Reason: The power switch of the infrared thermometer is not turned on or the device is connected after the software is turned on Solution: rec onnect the device, and then open the software.
2. Unit: "°C/°F" button on the front of the device (Figure.8). Just click on it. Short press
the "°C/°F" key to switch bet ween Celsius/Fahrenheit (Figure.9, 1 0)
1. P lease do not disassemble and ass emble the battery without permission. If the
battery is broken or exploded without authorization, it has nothing to do with our company
2. If you need to install the battery, please contact after-sales service
Manufacturer: Harbin Xiande Technology Development C o., Ltd
Office/Production Address: No.434 , Post Street,
Nangang District, Harbin, Heilongjiang
Technical R equirements for Products: HXLZ No 20202070039