AM1-WA1/AM1-XA1
Thermostats AM1-WA1 and AM1-XA1
automatically performs ON/OFF fan control in
accordance with the temperature fluctuation inside
the equipment. It helps improve the equipment’s
“environmental” performance relative to energy
savings, noise reduction, etc.
●Additional Information●
Technical Reference ➜ Page F-1
Safety Standards ➜ Page G-2
List of safety standard approved products (Model, Standards, File No., Certification Body)
●
Page G-11
➜
AM1-WA1 AM1-XA1
Features
■
Effective for Energy-Saving
●
Thermostat makes it possible for fans to operate only when cooling
is necessary.
This product makes for energy-saving by automatically stopping fans
for example, at night, when the amount of heat generation declines
following the load rate’s decline in equipment, or in winter, when the
ambient temperature drops and forced cooling is not necessary.
Noise Reduction
●
The fans are operated only when cooling is required, thereby keeping
fan noise to a minimum.
RoHS-Compliant
●
Thermostats AM1-WA1 and AM1-XA1 conform to the RoHS
Directive that prohibits the use of six chemical substances including
lead and cadmium.
Details of RoHS Directive
●
Product Line
■
The following items are included in each product.
Thermostat, Operating Manual
➜
Page G-38
Type Model
Fahrenheit AM1-WA1
Centigrade AM1-XA1
Easy Setting
●
Range of operating temperature: 0 to +60˚C (+32 to +140˚F)
In addition, the setting is very easy; all you have to do is set the front
dial to the desired temperature.
Elimination of Power Supply
●
There is no need to provide a separate power supply for the
thermostat.
Conforms to DIN Rail, Compact Design
●
W33 mm×H60 mm×D35 mm (W1.30 in.×H2.36 in.×D1.38 in.)
Thermo bimetal built-in thermostat
Specifications
■
Type of Sensor Thermo bimetal, Contact: Normal open
Operating Temperature Range [0∼60˚C (+32∼140˚F)]±10˚C (18˚F)
Differential [Operating temperature −7˚C (12.6˚F)]±4˚C (7.2˚F)
Applicable Lead Wire Size AWG18∼14 (0.75∼2.5 mm
Item Specifications
2
)
E-134
ORIENTAL MOTOR GENERAL CATALOG 2009/2010
General Specifications
■
Item Specifications
Between the frame
Dielectric
Strength
Ambient Temperature −20∼+80˚C (−4∼+176˚F)
Ambient Humidity 90 % or less (non-condensing)
Color Light gray
Notes:
If foreign objects get into the sensor, the thermostat may not work properly. The use of a filter
●
at the intake is recommended so foreign objects will not enter the area where the sensor is
located.
Be sure to use the applicable products.
●
Install the product on an IEC (DIN) rail. Make sure that no force (tension, stress, etc.) is
●
applied to the terminal section.
and the terminal
Between the
terminals
Sufficient to withstand 3.75 kVAC for one minute under
normal ambient temperature and humidity.
Sufficient to withstand 0.5 kVAC for one minute under
normal ambient temperature and humidity.
Features E-134 / Product Line E-134

Cooling Fans
Applicable Products
■
Input Series Model Number of Connectable Fans
Single-Phase
AC-Input
For ✽MB1665 type, thermostats can be used only for single-phase 100 VAC and 200 VAC
products.
Note:
Impression of voltage exceeding the rated voltage may shorten the service life of the product.
●
Effective Use of the Thermostat
■
MU Series All models 9
FM Series All models 9
MRS Series
MB Series
MF Series MF930, MF915 5
MRS25 1
MRS20 2
MRS18 2
MRS16 5
MB1665
MB1255
MB1040 4
MB840 7
MB630, MB520 9
✽
1
Dimensions
■
Mass: 45 g (1.6 oz.)
AM1-WA1:
AM1-XA1:
(
33
1.30
)
2.36
(
60
2
1
E108
E108
)
Using a fan with a thermostat provides automatic on/off control of the fan and air flow switching.
ON/OFF Control of a Single Fan
●
When the temperature within the enclosure rises to a specified level
(preset temperature), the thermostat activates the fan automatically.
Once the enclosure interior is sufficiently cooled, it causes the fan to
stop. This is a great way to save energy and reduce noise.
◇
Application Example
ON/OFF Control of Multiple Fans
●
Multiple fans can be effectively controlled in cases where more than
one fan is needed to produce the required air flow or static pressure.
For example, a thermostat can control a maximum of nine MU1238
type fans. (A six-fan configuration is shown.)
◇
Application Example
MU1238
Unit = mm (in.)
35
(
1.38
)
Introduction FM
Cooling Module
AC Input
MRS
Variable Flow
AC Input
MRS
Axial Flow Fans Centrifugal Blowers Cross Flow Fans
AC Input
MU
Long-Life
DC Input
MDE
MDS/MD
DC Input
◇
Connection Example
Cooling Module FM Series
AM1-WA1
AM1-XA1
AM1-WA1
AM1-XA1
AC Power Supply
AM1-WA1
AM1-XA1
◇
Connection Example
When using 6 fans ( ●MU1238)
Thermostat
Number of
ON 6 84 51
OFF – 0 0
Fans
AM1-WA1
AM1-XA1
AC Power Supply
InputWNoise Level
dB (A)
AC Input
MB
DC Input
MBD
AC Input
MF
DC Input
MFD
Thermostats Accessories Installation
Specifications E-134 / Dimensions E-135 / Connection E-135
E-135

Cooling Fans
AC Power Supply
■Temperature of Lower
Set Temperature: 25°C (77°F)
■Temperature of Upper
Set Temperature: 40°C (104°F)
AM1-WA1
AM1-XA1
Control the Number of Constant Speed Fans in Operation
●
The use of two thermostats enables switching the number of
fans being operated to change the air flow in accordance with
temperature.
This helps save energy and reduce noise.
This control method is effective with densely mounted equipment.
●
◇
Application Example
MU1238 ● Type Multiple Switching Control
Temperature
40˚C
High
(104˚F)
25˚C
Low
(77˚F)
Number of
InputWNoise Level
Fans
684 51
342 48
dB (A)
◇
Connection Example
Inside
Temperature
40˚C (104˚F)
33˚C (91˚F)
25˚C (77˚F)
18˚C (64˚F)
Upper
No Operation
ON
OFF
Operation OperationMax. Load of System
No Operation
Time
E-136
ON
Lower
OFF
Notes:
Connect the lead wire to the thermostat as shown in the diagrams, regardless of how many fans are used or of the fan's wire diameter.
●
When connecting multiple fans, always use a terminal block. Don't connect the lead wires of multiple fans directly to the thermostat.
●
When using variable flow fan, don't connect the lead wires for connecting variable resistor directly to the thermostat.
●
Recommended Crimp Terminal
●
Crimp terminal is not included. When crimp terminal is required for connecting, use the crimp terminal shown below.
Phoenix Contact Inc: Al 1-8
Applicable lead wire size: AWG18
ORIENTAL MOTOR GENERAL CATALOG 2009/2010
Features E-134 / Product Line E-134