AM1-WA1/AM1-XA1
Thermostats AM1-WA1 and AM1-XA1 automatically performs ON/OFF fan control in accordance with the temperature fluctuation inside the equipment. It helps improve the equipment’s “environmental” performance relative to energy savings, noise reduction, etc.
Additional Information
Technical Reference Page F-1
Safety Standards Page G-2
List of safety standard approved products (Model, Standards, File No., Certification Body)
Page G-11
AM1-WA1 AM1-XA1
Features
Effective for Energy-Saving
Thermostat makes it possible for fans to operate only when cooling is necessary. This product makes for energy-saving by automatically stopping fans for example, at night, when the amount of heat generation declines following the load rate’s decline in equipment, or in winter, when the ambient temperature drops and forced cooling is not necessary.
Noise Reduction
The fans are operated only when cooling is required, thereby keeping fan noise to a minimum.
RoHS-Compliant
Thermostats AM1-WA1 and AM1-XA1 conform to the RoHS Directive that prohibits the use of six chemical substances including lead and cadmium.
Details of RoHS Directive
Product Line
The following items are included in each product.
Thermostat, Operating Manual
Page G-38
Type Model
Fahrenheit AM1-WA1 Centigrade AM1-XA1
Easy Setting
Range of operating temperature: 0 to +60˚C (+32 to +140˚F) In addition, the setting is very easy; all you have to do is set the front dial to the desired temperature.
Elimination of Power Supply
There is no need to provide a separate power supply for the thermostat.
Conforms to DIN Rail, Compact Design
W33 mm×H60 mm×D35 mm (W1.30 in.×H2.36 in.×D1.38 in.) Thermo bimetal built-in thermostat
Specifications
Type of Sensor Thermo bimetal, Contact: Normal open Operating Temperature Range [0∼60˚C (+32∼140˚F)]±10˚C (18˚F) Differential [Operating temperature 7˚C (12.6˚F)]±4˚C (7.2˚F) Applicable Lead Wire Size AWG1814 (0.752.5 mm
Item Specifications
2
)
E-134
ORIENTAL MOTOR GENERAL CATALOG 2009/2010
General Specifications
Item Specifications
Between the frame
Dielectric Strength
Ambient Temperature −20∼+80˚C (−4∼+176˚F) Ambient Humidity 90 % or less (non-condensing) Color Light gray
Notes:
If foreign objects get into the sensor, the thermostat may not work properly. The use of a filter
at the intake is recommended so foreign objects will not enter the area where the sensor is located. Be sure to use the applicable products.
Install the product on an IEC (DIN) rail. Make sure that no force (tension, stress, etc.) is
applied to the terminal section.
and the terminal
Between the terminals
Sufficient to withstand 3.75 kVAC for one minute under normal ambient temperature and humidity.
Sufficient to withstand 0.5 kVAC for one minute under normal ambient temperature and humidity.
Features E-134 / Product Line E-134
Cooling Fans
Applicable Products
Input Series Model Number of Connectable Fans
Single-Phase
AC-Input
For ✽MB1665 type, thermostats can be used only for single-phase 100 VAC and 200 VAC products.
Note:
Impression of voltage exceeding the rated voltage may shorten the service life of the product.
Effective Use of the Thermostat
MU Series All models 9 FM Series All models 9
MRS Series
MB Series
MF Series MF930, MF915 5
MRS25 1 MRS20 2 MRS18 2 MRS16 5 MB1665
MB1255 MB1040 4 MB840 7 MB630, MB520 9
1
Dimensions
Mass: 45 g (1.6 oz.)
AM1-WA1: AM1-XA1:
(
33
1.30
)
2.36
( 60
2
1
E108
E108
)
Using a fan with a thermostat provides automatic on/off control of the fan and air flow switching.
ON/OFF Control of a Single Fan
When the temperature within the enclosure rises to a specified level (preset temperature), the thermostat activates the fan automatically. Once the enclosure interior is sufficiently cooled, it causes the fan to stop. This is a great way to save energy and reduce noise.
Application Example
ON/OFF Control of Multiple Fans
Multiple fans can be effectively controlled in cases where more than one fan is needed to produce the required air flow or static pressure. For example, a thermostat can control a maximum of nine MU1238 type fans. (A six-fan configuration is shown.)
Application Example
MU1238
Unit = mm (in.)
35
(
1.38
)
Introduction FM
Cooling Module
AC Input
MRS
Variable Flow
AC Input
MRS
Axial Flow Fans Centrifugal Blowers Cross Flow Fans
AC Input
MU
Long-Life
DC Input
MDS/MD
DC Input
Connection Example
Cooling Module FM Series
AM1-WA1 AM1-XA1
AM1-WA1 AM1-XA1
AC Power Supply
AM1-WA1 AM1-XA1
Connection Example
When using 6 fans ( ●MU1238)
Thermostat
Number of
ON 6 84 51
OFF 0 0
Fans
AM1-WA1 AM1-XA1
AC Power Supply
InputWNoise Level
dB (A)
AC Input
MB
DC Input
MBD
AC Input
MF
DC Input
MFD
Thermostats Accessories Installation
Specifications E-134 / Dimensions E-135 / Connection E-135
E-135
Cooling Fans
MU1238
AM1-WA1 AM1-XA1
AC Power Supply
Temperature of Lower Set Temperature: 25°C (77°F)
Temperature of Upper Set Temperature: 40°C (104°F)
AM1-WA1 AM1-XA1
Control the Number of Constant Speed Fans in Operation
The use of two thermostats enables switching the number of fans being operated to change the air flow in accordance with temperature. This helps save energy and reduce noise.
This control method is effective with densely mounted equipment.
Application Example
MU1238 ● Type Multiple Switching Control
Temperature
40˚C
High
(104˚F)
25˚C
Low
(77˚F)
Number of
InputWNoise Level
Fans
684 51
342 48
dB (A)
Connection Example
Inside Temperature
40˚C (104˚F) 33˚C (91˚F)
25˚C (77˚F) 18˚C (64˚F)
Upper
No Operation
ON OFF
Operation OperationMax. Load of System
No Operation
Time
E-136
ON
Lower
OFF
Notes:
Connect the lead wire to the thermostat as shown in the diagrams, regardless of how many fans are used or of the fan's wire diameter.
When connecting multiple fans, always use a terminal block. Don't connect the lead wires of multiple fans directly to the thermostat.
When using variable flow fan, don't connect the lead wires for connecting variable resistor directly to the thermostat.
Recommended Crimp Terminal
Crimp terminal is not included. When crimp terminal is required for connecting, use the crimp terminal shown below.
Phoenix Contact Inc: Al 1-8 Applicable lead wire size: AWG18
ORIENTAL MOTOR GENERAL CATALOG 2009/2010