RPM7237-R series
Photo Link Module
IR Receiver Module
RPM7237-R series
RPM7237-R series are remote control rec eiver modul e. Small-size d, light- weight, and low voltag e operated (from 2. 7V)
modules have been achieved by using resin mold.
zCenter frequency
36.7kHz
zApplications
All household electric appliances su ch as TV, DVD, air conditioner and audio equ ipment.
zFeatures
1) Low voltage operation. (V
2) Low current consumption. (I
3) Superior anti V
CC noise characteristics.
4) 5 types of holders available to each set.
zRPM7237-R series
CC=2.7 to 3.6V )
CC=0.3mA, VCC=3V)
Sub carrier
frequency
Height to lens
36.7kHz
RSIP-A3 (H13)
15.0mm
∗RPM7237-H13R
SIDE VIEW TOP VIEW
RSIP-A3 (H5)
9.6mm
RPM7237-H5R
RSIP-A3 (H4)
15.9mm
RPM7237-H4R
RSIP-A3 (H8)
7.2mm
RPM7237-H8R
RSIP-A3 (H9)
12.0mm
RPM7237-H9R
∗Under development
zAbsolute maximum ratings (Ta = 25°C)
Parameter Symbol
Supply Voltage
Output current
Storage temperature
Operating temperature voltage
Limits
CC
V
O
I
Tstg
Topr °C
6.3
2.0
−30 to +100
−10 to +75
Unit
V
mA
°C
zRecommended operating conditions (Ta = 25°C)
Parameter Symbol Min. Typ. Max. Unit
V
Supply voltage
CC
3.0 V2.7 3.6
Rev.B 1/6
RPM7237-R series
Photo Link Module
zBlock diagram
CC
V
100kΩ
Detector
ComparatorLIMITER
R
OUT
GND
I / V
AMP
BPF
zT ermina l description
Pin namePin No. Function
1V
2
3
OUT
GND
CC
V
OUTPUT TERMINAL
GROUND
POWER SUPPLY
zElectrical, Optical characteristics (Unless otherwise noted, Ta = 25°C V
Parameter Symbol Min. Typ. Max. Unit Conditions
CC
Consumption Current No outside light, No signal input
Effective Distance
High Level Output Voltage
Low Level Output Voltage
ON Pulse Width
OFF Pulse Width
Center frequency
Horizontal half angle
Vertical half angle
∗1 600/600µs burst wave is transmitted by standard transmitter. However, it must be measured after the initial transmission pulse is 10 pulse.
∗2 It is an angle when the linear arrival distance become half.
I
L
V
V
T
ON
T
OFF
fo
θ 1/2
θ 1/2
H
L
2.5
400
400
300 µA
−
8
−
−
−
−
15
−
−
600
600
36.7
45
35
500
0.5
800
−
−
CC=3V)
m−
Outer light condition Ee < 10 (Ix)
V−
<
Isink
V
µs
µs800
kHz−
deg
deg
200µA
=
Outer light condition Ee < 10 (Ix)
Outer light condition Ee < 10 (Ix)
z Measurement Conditions
(1) Transmit signal
∗1
∗1
∗1
∗1
∗1
∗2
∗2
600µs 600µs
Carrier frequency=fo, Duty=50%
Fig.1 Transmit signal
Rev.B 2/6
RPM7237-R series
Photo Link Module
(2) Stand ard transmitter
λ peak=940nm
∆
λ=40nm
OUT
/ R
20cm
RPM-302B
io=V
Standard transmitter
Fig.2 Measurement of standard transmitter proofreading
R
V
OUT
When standard transmitter output the signal at Fig.1 standard photodiode output become io=5µAp-p under the
measurement condition Fig.2.
(The radiant intensity of standard transmitter : 50mW / sr)
RPM-302B : standard photodiode has short current Isc=27 µA at Ee=1000(lx)
(using CIE standard light sou rce A)
(3) Measurement effective distan ce, horizonta l & vertical half angl e
RPM7237-R series
θ
θ
Standard transmitter
Light detector face
illuminance : Ee
Effective distance : L
(θ ; Indicates horizontal and vertical directions)
Fig.3 Measurement condition for effective distance
Effective distance L : Effective distance at θ=0° Fig.3
Horizontal & vertical half angle θ: The angle which effe ctive distan ce became 50% of L .
Rev.B 3/6