RPM7157-R series are remote control receiver modules. Small-sized, light-weight, and low current consumption
modules have been achieved by using resin mold.
zCenter frequency
56.9kHz
zApplications
All household electric appliances su ch as TV, DVD, air conditioner and audio equ ipment.
zElectrical characteristics (Unless otherwise noted, T a = 25°C V
ParameterSymbolMin.Typ.Max.UnitConditions
Consumption CurrentI
Effective Distance
High Level Output Voltage
Low Level Output Voltage
ON Pulse Width
OFF Pulse Width
Center frequency
Horizontal half angle
Vertical half angle
∗1 600/600µs burst wave is transmitted by standard transmitter. However, it must be measured after the initial transmission pulse is 100 pulse.
∗2 It is an angle when the linear arrival distance become half.
CC
L
V
H
V
T
ON
T
OFF
fo
θ 1/2
θ 1/2
L
−
8
4.5
−
400
400
−
−
−
1.0mANo outside light, No signal input
15
−
−
600
600
56.9
45
35
1.6
0.5
800
−
−
CC=5V)
kHz−
deg
deg
m−
Outer light condition Ee < 10 (Ix)
V−
V
Isink=200µA
Outer light condition Ee < 10 (Ix) ∗1
µs
µs800
Outer light condition Ee < 10 (Ix) ∗1
z Measurement Conditions
(1) Transmit signal
∗1
∗1
∗1
∗2
∗2
600µs600µs
Carrier frequency=fo, Duty=50%
Fig.1 Transmit signal
Rev.A 2/7
Photo Link Module
(2) Stand ard transmitter
λ peak=940nm
λ ∆=40nm
20cm
RPM-302B
RPM7157-R series
OUT
/ R
Io=V
Standard transmitter
Fig.2 Measurement of standard transmitter proofreading
R
V
OUT
When standard transmitter output the signal at Fig.1 standard photodiode output become Io=5µAp-p under the
measurement condition Fig.2.
(The radiant intensity of standard transmitter : 50mW / sr)
RPM-302B : standard photodiode has short current Isc=27 µA at E=1000(lx)
(using CIE standard light sou rce A)
(3) Measurement effective distance, horizont al & vertical half angle
RPM7157-R series
θ
θ
Standard transmitter
Light detector face
illuminance : Ee
Effective distance : L
(θ ; Indicates horizontal and vertical directions)
Fig.3 Measurement condition for effective distance
Effective distance L : Effective distance at θ=0° Fig.3
Horizontal & vertical half angle θ : The angle which effective distance became 50% of L.
Rev.A 3/7
Photo Link Module
(4) Output signal
RPM7157-R series
Transmit signal
Output signal
600µs
T
ON
Fig.4
600µs
T
OFF
(5) Measurement circuit for the output voltage and the consumption current
CC
V
I
CC
A
Carrier frequency=f
Carrier Duty=50%
V
CC
V
H
CC
1/2 V
V
L
GND
0
R
OUT
V
RPM7157-R
GND
Fig.5
V
V
H
, V
L
CC
Rev.A 4/7
RPM7157-R series
Photo Link Module
zHow to use the receiver without holder
Please use the receiver with shield case or shield plate as an EMI noise measures.
(Shield case and shield plate are required to be grounded.)
Because internal or external noise (CRT, fluorescent tube, motor, LCD backlight) of the receiver may caus e malf unctio n
like a reduced effective distance.
(In the case of internal and external noise are strong, please use RPM7157-HxR series with holder.)
zNotes
(1) All characteristics of the receiver in this specification are specified by supplying burst wave form with ROHM standard
transmitter (Shown as 8 (2) ).
If in case of other burst wave form w ill be used, p lease check th ese spec. Ca refully under the evaluations.
(2) When the receiver will be used as the w ire-less remote contro ller , please use the signal method the signal fo rmat
which refer to “Measures to prevent malfunctioning of IR remote-controlled electric home appliances”. (Published July
1987 by Association of Electric Home Appliances)
If using other signal method, signal format, (ex: signal format which not including the leader signal) the receiver might
have chances to miss-functio n.
(3) Please set up transmitter’s carrier frequency as same as the receiver’s f
occurred.
(4) If transmission signal has non-continues carrie r , error might be occurred . Continuous carrier is nece ssary.
0 frequency. Otherwise error might be
T1
T1≠T2
T2
(5) The receiver was designed to use as in-door use only.
Therefore, please understand that the receiver cannot cover all characteristics, in case of using it out-door.
(6) Noise environment (Light noise from inverter Lamp, and other kind of Lamps, Power ripple, electromagnetic noise from
power circuit, and etc) may cause a reduced effective distance.
(7) Emitting unit (remote control transmitter) has to be considered about its emitting device function, characteristics and
characteristics of the receiver.
(8) Please connect “Holder” on to the “Ground (GND)” of PCB.
If the holder is not connected to the GND, there is a possibility of worsening the characteristics of product.
(9) Do not supply unnecessary stre ss to lead.
(10) Please pay careful attention to the lens.
It might have a chance to miss-function w hen the lens get dust o r dirty. And also please do not touch the lens.
(11) In order to prevent IC from ESD, human body and solder iron, etc. are required to be grounded.
Rev.A 5/7
Photo Link Module
zElectrical and optical characteristics curves
0.00
120
100
RPM7157-R series
−2.00
−4.00
−6.00
Gain : (dB)
−8.00
−10.00
−4−3 −2 −1fo+1 +2 +3 +4
Frequency : (kHz)
Fig.6 RPM7157 Series BPF Characteristics
100
80
60
80
60
40
20
Rerative sensitivity : (%)
0
700 750 800 850 900 950 1000 1050 1100 1150 1200
Wave length : λ (nm)
Fig.7 Optical bandwidth of the
photo-diode encapsulation
100
80
60
40
20
Relative effective distance : (%)
0
−80 −60 −40 −20020 4060 80
Angle : (˚)
Fig.8 Direction characteristic
(Horizontal direction)
40
20
Relative effective distance : (%)
0
−80 −60 −40 −20020 4060 80
Angle : (˚)
Fig.9 Direction characteristic
(Vertical direction)
Rev.A 6/7
Photo Link Module
zDimensions (Unit : mm)
9.0
1.8
6.0
0.4
3.6
1.4 6.3
2.542.54
7.95
2.5
1.4 4.6
RSIP-A3 (H13)
RPM7157-R series
7.3
7.30
3.607.20
0.651.40
17.95
15.0
3.6
0.5
0.6
0.6
2.95
7.00
123
2.542.54
9.25
0.50
3.60
1.80
2.351.40
0.40
0.60
0.30
0.60
6.5
9.0Max.
22Min.
4.0
123
2.54
RSIP-A3 (H8)RSIP-A3
4.8
3.2
6.0
2.54
0.8
1.5
0.4
0.5
15.9
3.6
2.35
0.65
1.4
1.4
4.2
0.60.6
0.5
1.8
0.4
7.3
2.95
7.0
12.65
2.542.54
RSIP-A3 (H4)RSIP-A3 (H9)
1.89.0
6.0
3.6
12.55
3.6
0.4
2.5
4.61.4
1.4
6.3
2.542.54
7.3
2.95
1.0
0.5
0.60.6
7.30
2.95
7.00
123
2.542.54
12.00
3.60
2.35
6.5
9.0Max.
0.5
4.8
3.2
6.0
0.8
4.0
312
0.4
1.5
2.5
20.0min
2.542.54
0.50
12.65
1.80
1.40
1.400.65
3.60
0.40
0.60
0.60
0.30
RSIP-A3 V4
Pin No.
Rout
GND
V
CC
RSIP-A3 (H5)
Rev.A 7/7
Appendix
No technical content pages of this document may be reproduced in any form or transmitted by any
means without prior permission of ROHM CO.,LTD.
The contents described herein are subject to change without notice. The specifications for the
product described in this document are for reference only. Upon actual use, therefore, please request
that specifications to be separately delivered.
Application circuit diagrams and circuit constants contained herein are shown as examples of standard
use and operation. Please pay careful attention to the peripheral conditions when designing circuits
and deciding upon circuit constants in the set.
Any data, including, but not limited to application circuit diagrams information, described herein
are intended only as illustrations of such devices and not as the specifications for such devices. ROHM
CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any
third party's intellectual property rights or other proprietary rights, and further, assumes no liability of
whatsoever nature in the event of any such infringement, or arising from or connected with or related
to the use of such devices.
Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or
otherwise dispose of the same, no express or implied right or license to practice or commercially
exploit any intellectual property rights or other proprietary rights owned or controlled by
ROHM CO., LTD. is granted to any such buyer.
Products listed in this document are no antiradiation design.
Notes
The products listed in this document are designed to be used with ordinary electronic equipment or devices
(such as audio visual equipment, office-automation equipment, communications devices, electrical
appliances and electronic toys).
Should you intend to use these products with equipment or devices which require an extremely high level of
reliability and the malfunction of with would directly endanger human life (such as medical instruments,
transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers and other
safety devices), please be sure to consult with our sales representative in advance.
About Export Control Order in Japan
Products described herein are the objects of controlled goods in Annex 1 (Item 16) of Export Trade Control
Order in Japan.
In case of export from Japan, please confirm if it applies to "objective" criteria or an "informed" (by MITI clause)
on the basis of "catch all controls for Non-Proliferation of Weapons of Mass Destruction.
Appendix1-Rev1.1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.