ROHM UMH14N, IMH14A Technical data

UMH14N / IMH14A
Transistors

General purpose (dual digital transistors)

UMH14N / IMH14A

zFeatures
zEquivalent circuit
UMH14N
(3)
(2) (1)
R
1
(4) (5) (6)
R
1
IMH14A
(4)
(5) (6)
R
1
(3) (2) (1)
R
1
zPackage, marking, and packaging specifications
Type
Package
Marking
Code
Basic ordering unit (pieces)
UMH14N
UMT6
H14
TR
3000
IMH14A
SMT6
H14 T108 3000
zAbsolute maximum ratings (Ta=25°C)
Collector-base voltage
Parameter Symbol
Collector-emitter voltage Emitter-base voltage Collector current
Collector power dissipation Junction temperature
Storage temperature
UMH14N
IMH14A
CBO
V VCEO VEBO
IC
Pc
Tj
Tstg
Limits
50 50
5
100 150(TOTAL) 300(TOTAL)
150
55
to
+150
zElectrical characteristics (Ta=25°C)
Parameter Symbol Min. Typ. Max. Collector-base breakdown voltage Collector-emitter breakdown voltage Emitter-base breakdown voltage Collector cutoff current Emitter cutoff current Collector-emitter saturation voltage DC current transfer ratio
Transition frequency
Input resistance
Transition frequency of the device.
BV BV BV
V
CBO CEO EBO
I
CBO
I
EBO
CE(sat)
h
FE
f
T
R
1
Unit
V V V
mA
mW
°C °C
50 50
100
32.9 47 61.1
zExternal dimensions (Unit : mm)
UMH14N
0.2
0.1Min.
ROHM : UMT6 EIAJ : SC-88
IMH14A
0.3Min.
ROHM : SMT6 EIAJ : SC-74
Unit
V
0.5
0.5
0.3
600
V
V
µA µA
V
MHz
k
5
250 250
)
)
4
3
(
(
)
5
(
)
)
6
1
(
(
1.25
2.1
0.15
0~0.1
Each lead has same dimensions
)(
)
6
1
(
0.3
0.15
(
)(
)
5
2
(
)
)
4
3
(
1.6
2.8
0~0.1
Each lead has same dimensions
I
C
=50µA IC=1mA I
E
=50µA V
CB
=50V
EB
=4V
V IC/IB=10mA/1mA VCE/IC=5V/1mA V
CE
=10V, IE= −5mA, f=100MHz
0.65
)
2
(
1.3
0.65
0.9
0.7
0.95
1.9
0.95
1.1
0.8
Conditions
2.0
2.9
Rev.A 1/2
Transistors
zElectrical characteristics curves
1k
500
FE
200 100
50
20 10
5
DC CURRENT GAIN : h
2 1
100µ 200µ 500µ 1m 2m 5m 10m 20m 50m 100m
COLLECTOR CURRENT : I
Ta=100°C
Fig.1 DC current gain vs. collector
current
25°C
40°C
C
V
(A)
CE
=
5V
1
(V)
500m
CE(sat)
200m 100m
50m
20m 10m
5m
2m 1m
100µ 200µ 500µ 1m 2m 5m 10m 20m 50m 100m
COLLECTOR SATURATION VOLTAGE : V
Ta=100°C
COLLECTOR CURRENT : I
Fig.2 Collector-emitter saturation
voltage vs. collector current
25°C
40°C
lC/lB=10
C
(A)
UMH14N / IMH14A
Rev.A 2/2
Appendix
No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and operation. Please pay careful attention to the peripheral conditions when designing circuits and deciding upon circuit constants in the set. Any data, including, but not limited to application circuit diagrams information, described herein are intended only as illustrations of such devices and not as the specifications for such devices. ROHM CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any third party's intellectual property rights or other proprietary rights, and further, assumes no liability of whatsoever nature in the event of any such infringement, or arising from or connected with or related to the use of such devices. Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design.
Notes
The products listed in this document are designed to be used with ordinary electronic equipment or devices (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger human life (such as medical instruments, transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers and other safety devices), please be sure to consult with our sales representative in advance.
About Export Control Order in Japan
Products described herein are the objects of controlled goods in Annex 1 (Item 16) of Export Trade Control Order in Japan. In case of export from Japan, please confirm if it applies to "objective" criteria or an "informed" (by MITI clause) on the basis of "catch all controls for Non-Proliferation of Weapons of Mass Destruction.
Appendix1-Rev1.1
Loading...