Digital 16bit Serial Output Type
Ambient Light Sensor IC
BH1751FVI
●Descriptions
BH1751FVI is an digital Ambient Light Sensor IC for I
data for adjusting LCD and Keypad backlight power of Mobile phone. It is possible to detect wide range at High resolution.
( 1 - 65535 lx ).
●Features
1) I2C bus Interface (f / s Mode Support)
2) Spectral responsibility is approximately human eye response
3) Illuminance to Digital Converter
4) Wide range and High resolution. (1 - 65535 lx)
5) Low Current by power down function
6) 50Hz / 60Hz Light noise reject-function
7) 1.8V Logic input interface
8) No need any external parts
9) Light source dependency is little. (ex. Incandescent Lamp. Fluorescent Lamp. Halogen Lamp. White LED. Sun Light )
10) It is possible to select 2 type of I2C slave-address.
11) Adjustable measurement result for influence of optical window
( It is possible to detect min. 0.11 lx, max. 100000 lx by using this function. )
12) Small measurement variation (+/- 20%)
13) The influence of infrared is very small.
14) Build in power on reset circuit
●Applications
Mobile phone, LCD TV, NOTE PC, Portable game machine, Digital camera, Digital video camera, PDA, LCD display
●Absolute Maximum Ratings
2
C bus interface. This IC is the most suitable to obtain the ambient light
No.11046EBT09
Parameter SymbolRatings Units
Supply Voltage Vmax
Operating Temperature Topr -40~85 ℃
Storage Temperature Tstg -40~100 ℃
SDA Sink Current Imax 7 mA
Power Dissipation Pd 260※ mW
※ 70mm × 70mm × 1.6mm glass epoxy board. Derating in done at 3.47mW/℃ for operating above Ta=25℃.
● Electrical Characteristics ( VCC = 3.0V, DVI = 3.0V, Ta = 25℃, unless otherwise noted )
Parameter Symbol
Min. Typ. Max.
Limits
Units Conditions
Supply Current Icc1 -120 190 µA Ev = 100 lx
Powerdown Current Icc2 -0.85 1.5 µA No input Light
Peak Wave Length λp - 560 - nm
Technical Note
1
※
Measurement Accuracy S/A 0.96 1.2 1.44 times
Dark ( 0 lx ) Sensor out S0 0 0 3 count H-Resolution Mode
Sensor out / Actual lx
EV = 1000 lx
※
1, ※2
※
H-Resolution Mode Resolution rHR- 1 - lx
L-Resolution Mode Resolution rLR- 4 - lx
H-Resolution Mode
Measurement Time
L-Resolution Mode
Measurement Time
Incandescent /
Fluorescent Sensor out ratio
tHR- 120 180 ms
t
LR- 16 24 ms
F- 1 - times
rI
EV = 1000 lx
ADDR Input ‘H’ Voltage VAH0.7 * VCC- - V
ADDR Input ‘L’ Voltage VAL--0.3 * VCCV
DVI Input ‘L’ Voltage VDVL-- 0.4 V
SCL, SDA Input ‘H’ Voltage 1 VIH1 0.7 * DVI- - V DVI ≧ 1.8V
SCL, SDA Input ‘H’ Voltage 2 VIH2 1.26 - - V 1.65V ≦ DVI <1.8V
SCL, SDA Input ‘L’ Voltage 1 VIL1 - -0.3 * DVIV DVI ≧ 1.8V
3
SCL, SDA Input ‘L’ Voltage 2 VIL2 - -DVI – 1.26V 1.65V ≦ DVI < 1.8V
SCL, SDA, ADDR Input ‘H’ Current IIH
SCL, SDA, ADDR Input ‘L’ Current IIL
I2C SCL Clock Frequency fSCL
I2C Bus Free Time tBUF 1.3
I2C Hold Time ( repeated )
START Condition
I2C Set up time
for a Repeated START Condition
I2C Set up time
for a Repeated STOP Condition
t
HDSTA 0.6
SUSTA 0.6
t
t
SUSTD 0.6
I2C Data Hold Time tHDDAT 0
I2C Data Setup Time tSUDAT 100
I2C ‘L’ Period of the SCL Clock tLOW 1.3
I2C ‘H’ Period of the SCL Clock tHIGH 0.6
I2C SDA Output ‘L’ Voltage VOL 0
※1 White LED is used as optical source.
※2 Measurement Accuracy typical value is possible to change '1' by "Measurement result adjustment function".
※3 Use H-resolution mode or H-resolution mode2 if dark data ( less than 10 lx ) is need.
Photo diode with approximately human eye response.
・AMP
Integration-OPAMP for converting from PD current to Voltage.
・ADC
AD converter for obtainment Digital 16bit data.
2
・Logic + I
・OSC
・POR
●Measurement Procedure
State is automatically changed to
Power Down mode.
C Interface
Ambient Light Calculation and I2C BUS Interface. It is including below register.
Data Register → This is for registration of Ambient Light Data. Initial Value is "0000_0000_0000_0000".
Measurement Time Register → This is for registration of measurement time. Initial Value is "0100_0101".
Internal Oscillator ( typ. 320kHz ). It is CLK for internal logic.
Power on reset. All register is reset after VCC is supplied. Please refer P.8 (Caution of power on reset function).
One Time Measurement
PD
AMP
Power supply
Power Down
Power On
Measurement Command
ADC
VCC
OSC
GND
Initial state is Power Down mode after
VCC and DVI supply.
Power On 0000_0001 Waiting for measurement command.
Technical Note
Reset 0000_0111
Continuously H-Resolution Mode 0001_0000
Continuously H-Resolution Mode2 0001_0001
Continuously L-Resolution Mode 0001_0011
One Time H-Resolution Mode 0010_0000
One Time H-Resolution Mode2 0010_0001
One Time L-Resolution Mode 0010_0011
Change Measurement time
( High bit )
Change Masurement time
( Low bit )
※ Don't input the other opecode.
●Measurement mode explanation
Measurement Mode Measurement Time. Resolurtion
H-resolution Mode2 Typ. 120ms. 0.5 lx
H-Resolution Mode Typ. 120ms. 1 lx.
L-Resolution Mode Typ. 16ms. 4 lx.
We recommend to use H-Resolution Mode.
Measurement time ( integration time ) of H-Resolution Mode is so long that some kind of noise( including in 50Hz / 60Hz
noise ) is rejected. And H-Resolution Mode is 1 l x resolution so that it is suitable for darkness ( less than 10 lx )
H-resolution mode2 is also suitable to detect for darkness.
●Explanation of Asynchronous reset and Reset command "0000_0111"
1) Asynchronous reset
All registers are reset and BH1751FVI becomes power down during DVI = 'L'. Initial reset is not necessary, because power
on reset function is included in this product.
2) Reset command
Reset command is for only reset Illuminance data register. ( reset value is '0' )It is not necessary after power supply to
VCC because power on reset function is included in this product.
It is used for removing previous measurement result. This command is not working in power down mode, so that please
set the power on mode before input this command.
01000_MT[7,6,5]
011_MT[4,3,2,1,0]
Reset Data register value. Reset command is not acceptable in
Power Down mode.
Start measurement at 1lx resolution.
Measurement Time is typically 120ms.
Start measurement at 0.5lx resolution.
Measurement Time is typically 120ms.
Start measurement at 4lx resolution.
Measurement Time is typically 16ms.
Start measurement at 1lx resolution.
Measurement Time is typically 120ms.
It is automatically set to Power Down mode after measurement.
Start measurement at 0.5lx resolution.
Measurement Time is typically 120ms.
It is automatically set to Power Down mode after measurement.
Start measurement at 4lx resolution.
Measurement Time is typically 16ms.
It is automatically set to Power Down mode after measurement.
Change measurement time.
※ Please refer "adjust measurement result for influence of optical window."
Change measurement time.
※ Please refer "adjust measurement result for influence of optical window."
●Timing chart for VCC and DVI power supply sequence
DVI is I2C bus reference voltage terminal. And it is also asynchronous reset terminal. In DVI 'L' term, internal state is set to
Power Down mode.Initial reset is not necessary, because power on reset function is included in this product. DVI supply with
VCC supply, or after VCC supply. Please do not become DVI>VCC.
1) Recommended Timing chart1 for VCC and DVI supply.
VCC
DVI
2) Recommended Timing chart2 for VCC and DVI supply.