BD7F100EFJ-EVK-002 Evaluation board delivers outputs 15volts and -15 volts from an input 24 volts using BD7F100EFJ-LB, Isolated Flyback DC/DC converter integrated circuit, with output current rating of maximum 0.165A.
Performance specification
These are representative values, and it is not a guaranteed against the characteristics. VIN = 24V, V
OUT1
= 15V, V
= -15V, Unless otherwise specified.
OUT2
Parameter Min Typ Max Units Conditions
Input Voltage 24.0 V Output Voltage 1 15.0 V R4=3.9k, R5=76.8k Output Voltage 2 -15.0 V R4=3.9k, R5=76.8k Output Current 1 Range 3.2 165 mA
Maximum Output Power5W
Output Current 2 Range 3.2 165 mA Operating Frequency 400 kHz Maximum Efficiency 81.7 % IO = 165mA
Evaluation Board
PCB size: 70mm×50mm×1.6mm
Figure 1. BD7F100EFJ-EVK-002 Evaluation Board Figure 2. BD7F100EFJ-EVK-002 Evaluation Board
Top View Bottom View
© 2017 ROHM Co., Ltd.
1/5
No. 60UG028E Rev.00
BD7F
100
EFJ-
EVK
-
002
1
2017
V
User’s Guide
Operation Procedures
1. Necessary equipments (1) DC power-supply of 24V/0.5A
(2) Maximum 0.165A load per output (3) DC voltmeter
2. Connecting the equipments (1) DC power-supply presets to 24V and then the power output turns off.
(2) The maximum load should be set at 165mA and over it will be disabled. (3) Connect positive-terminal of power-supply to VIN terminal and negative-terminal to GND terminal with a pair of wires. (4) Connect positive-terminal of load 1 to VOUT+ terminal and negative-terminal to COM terminal with a pair of wires. (5) Connect positive-terminal of load 2 to COM terminal and negative-terminal to VOUT- terminal with a pair of wires. (6) Connect positive-terminal of DC voltmeter 1 to VIN and negative-terminal to GND for input-voltage measurement. (7) Connect positive-terminal of DC voltmeter 2 to VOUT+ and negative-terminal to COM for output-voltage measurement. (8) Connect positive-terminal of DC voltmeter 3 to VOUT- and negative-terminal to COM for output-voltage measurement. (9) DC power-supply output is turned ON. (10) Check DC voltmeter 2 displays 15V. (11) Check DC voltmeter 3 displays -15V. (12) The load is enabled.
DC Voltmeter 1
DC Power
V
+
-
+
-
+
DC Voltmeter 2
-
-
V
DC Voltmeter 3
+
Load 1
Load 2
© 2017 ROHM Co., Ltd.
Figure 3. Connection Diagram