![](/html/fe/fe22/fe2265eb9eb847e8a35c17d1e377fc3e18aafc3cc9813b7f4bad0c88c4cde891/bg1.png)
User’s Guide
Switching Regulator Series
Isolated Flyback DC/DC Converter
BD7F100EFJ-LB Evaluation Board
BD7F100EFJ-EVK-002 (24V→±15V, 0.165A)
BD7F100EFJ-EVK-002 Evaluation board delivers outputs 15volts and -15 volts from an input 24 volts using BD7F100EFJ-LB, Isolated Flyback
DC/DC converter integrated circuit, with output current rating of maximum 0.165A.
Performance specification
These are representative values, and it is not a guaranteed against the characteristics.
VIN = 24V, V
OUT1
= 15V, V
= -15V, Unless otherwise specified.
OUT2
Parameter Min Typ Max Units Conditions
Input Voltage 24.0 V
Output Voltage 1 15.0 V R4=3.9kΩ, R5=76.8kΩ
Output Voltage 2 -15.0 V R4=3.9kΩ, R5=76.8kΩ
Output Current 1 Range 3.2 165 mA
Maximum Output Power:5W
Output Current 2 Range 3.2 165 mA
Operating Frequency 400 kHz
Maximum Efficiency 81.7 % IO = 165mA
Evaluation Board
PCB size: 70mm×50mm×1.6mm
Figure 1. BD7F100EFJ-EVK-002 Evaluation Board Figure 2. BD7F100EFJ-EVK-002 Evaluation Board
Top View Bottom View
© 2017 ROHM Co., Ltd.
1/5
No. 60UG028E Rev.00
OCT.
![](/html/fe/fe22/fe2265eb9eb847e8a35c17d1e377fc3e18aafc3cc9813b7f4bad0c88c4cde891/bg2.png)
User’s Guide
Operation Procedures
1. Necessary equipments
(1) DC power-supply of 24V/0.5A
(2) Maximum 0.165A load per output
(3) DC voltmeter
2. Connecting the equipments
(1) DC power-supply presets to 24V and then the power output turns off.
(2) The maximum load should be set at 165mA and over it will be disabled.
(3) Connect positive-terminal of power-supply to VIN terminal and negative-terminal to GND terminal with a pair of wires.
(4) Connect positive-terminal of load 1 to VOUT+ terminal and negative-terminal to COM terminal with a pair of wires.
(5) Connect positive-terminal of load 2 to COM terminal and negative-terminal to VOUT- terminal with a pair of wires.
(6) Connect positive-terminal of DC voltmeter 1 to VIN and negative-terminal to GND for input-voltage measurement.
(7) Connect positive-terminal of DC voltmeter 2 to VOUT+ and negative-terminal to COM for output-voltage measurement.
(8) Connect positive-terminal of DC voltmeter 3 to VOUT- and negative-terminal to COM for output-voltage measurement.
(9) DC power-supply output is turned ON.
(10) Check DC voltmeter 2 displays 15V.
(11) Check DC voltmeter 3 displays -15V.
(12) The load is enabled.
DC Voltmeter 1
DC Power
V
+
-
+
-
+
DC Voltmeter 2
-
-
V
DC Voltmeter 3
+
Load 1
Load 2
© 2017 ROHM Co., Ltd.
Figure 3. Connection Diagram
2/5
No. 60UG028E Rev.00
OCT.