V1.018-11-15 HW team FCC version of manual. FCC warnings added.
V1.131-03-16 HW team Added warnings required by IC.
Translation of all warnings into French, as required by IC.
V1.206-01-17 HW team In “Warnings and cautions” added several warnings as
required by FCC and IC, including French translations.
In 4.5.2 IC warning statements added, including French
translations.
In 4.5.2 Antenna types listed that can be used in combination
with the BSS in Canada.
V1.329-03-17 TN teamITU emission designator updated from 18K to 22K to match
with the test reports.
Issue 1.2, 06 January 2017Confidentialiii
IntroductionTetraNode Base Station System
Warnings and Cautions
Caution:
This manual contains important information concerning installation,
maintenance and user instructions for the R-8070 based TetraNode Base Station.
Read the following pages before installing or using the equipment.
Attention:
Ce manuel contient des informations importantes concernant l'installation et la
maintenance de la station de base R-8070 TetraNode, ainsi que les instructions
destinées aux utilisateurs.
Bien lire ce manuel avant toute installation ou utilisation de l’équipement.
Warning:
This Equipment MUST be connected to a SAFETY EARTH.
Avertissement:
Cet équipement DOIT être connecté à une prise de terre.
Warning:
Do NOT operate the TetraNode Base Station without a suitable high-power 50Ω
load(s) or correctly tuned antenna system being connected.
Avertissement:
Ne PAS faire fonctionner la station de base TetraNode sans une haute-puissance
appropriée d’une charge de 50Ω ou sans une connexion à un système d'antennes
correctement réglé.
Warning:
Do NOT touch or disconnect live (in use) antennas – RF energy can cause
burns!
Issue 1.2, 06 January 2017Confidentialiv
IntroductionTetraNode Base Station System
Avertissement:
Ne PAS toucher ni débrancher les antennes actives (en cours d’utilisation) L'énergie des fréquences radio peut causer des brûlures !
Warning:
Always ensure that the equipment is turned off before disconnecting antenna
cables.
Avertissement:
Toujours s'assurer que l'équipement est éteint avant de débrancher les câbles de
l’antenne.
Warning:
If working on a partially running site (half online), be careful of live power and
RF connections.
Avertissement:
Si vous travaillez sur un site opérant partiellement (partiellement en ligne), faites
attention à l'alimentation sous tension et aux connexions des fréquences radio.
Warning:
If connecting to floating power supplies take care to minimise touch-currents.
Correctly earthed supplies are preferred over floating supplies.
Avertissement:
Lors d’une connexion à une source d’alimentation instable, prendre soin de
minimiser les fuites de courant. A privilégier les sources fixes d’alimentation,
correctement mises à la terre.
Warning:
If dual power supplies are used for redundancy, ensure warnings are clearly
posted on the cabinet and double circuit isolators are provided.
Issue 1.2, 06 January 2017Confidentialv
IntroductionTetraNode Base Station System
Avertissement:
En cas d’utilisation de deux sources d'alimentation dans un but de redondance,
prendre soin d’afficher clairement les avertissements sur l’armoire et de fournir
une isolation double circuit.
Warning:
Do not connect equipment-room earth to the same earth used for the tower
lightning protection.
Avertissement:
Ne PAS connecter la prise de terre de la salle d’équipements à la même prise de
terre du paratonnerre de la tour.
Warning:
Do NOT work on antenna cables or systems when there is any nearby/local
electrical storm activity.
Avertissement:
Ne PAS travailler sur les câbles ou les systèmes des antennes en cas d’orage
voisin/local.
Warning:
The protective earths within the TetraNode Base Station should be adequately
bonded to the electrical earth of the 19” rack cabinet and NOT to any lightning
protection system for transmitter-towers/antennas.
Avertissement:
Les protections de mise à la terre de la station de base TetraNode doivent être
adéquatement jointes à la mise à la terre de la grille 19" de l'armoire et NON au
système paratonnerre des pylônes d’émission/d'antennes.
Issue 1.2, 06 January 2017Confidentialvi
IntroductionTetraNode Base Station System
Warning:
The power supply for the TETRA Base Station is low-voltage, but is nonetheless
capable of delivering a hazardous energy level if short-circuited. Always
disconnect the power before working on this equipment or connected systems.
Avertissement:
L'alimentation de la station de base TETRA est de basse tension, toutefois celleci est capable de fournir un niveau dangereux d'énergie si court-circuitée.
Toujours débrancher l'alimentation avant de travailler sur cet équipement ou tout
autre système connecté.
Warning:
All power installations must additionally comply with all local wiring
regulations.
Avertissement:
Toutes les installations d’alimentation doivent en outre se conformer aux
régulations locales de câblage.
Warning:
Do NOT fit 3rd party equipment into this cabinet. Operating the equipment with
non-Rohill-approved components inside invalidates all warranties and may
compromise your safety!
Avertissement:
Ne PAS monter un équipement de tierce partie dans cette armoire. L'exploitation
de l'équipement avec des composants non approuvés par Rohill annule toute
garantie et pourrait compromettre votre sécurité !
Warning (FCC Part 15.19):
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Issue 1.2, 06 January 2017Confidentialvii
IntroductionTetraNode Base Station System
Avertissement (FCC Section 15.19):
Cet appareil est conforme à la section 15 des règles de la FCC (Commission
fédérale des communications). Son fonctionnement est soumis aux deux
conditions suivantes : (1) Cet appareil ne doit pas provoquer d'interférences
nuisibles, et (2) cet appareil doit accepter toute interférence reçue, y compris les
interférences pouvant provoquer un fonctionnement indésirable.
Warning (FCC Part 15.21):
Rohill Engineering B.V. is not responsible for any changes or modification not
expressly approved by the party responsable for compliance. Such modifications
could void the user's authority to operate the equipment.
Avertissement (FCC Section 15.21):
Rohill Engineering B.V. n'est pas responsable de tout changement ou
modification non expressément approuvés par la partie responsable de la
conformité. De telles modifications peuvent annuler l'autorisation de l'utilisateur
à faire fonctionner l'équipement.
Warning (FCC Part 15.105(b)):
The equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
–Reorient or relocate the receiving antenna;
–Increase the separation between the equipment and receiver;
–Consult the dealer or an experienced radio/TV technician for help.
Issue 1.2, 06 January 2017Confidentialviii
IntroductionTetraNode Base Station System
Avertissement (FCC Section 15.105(b)):
Cet équipement a été testé et reconnu conforme aux limites des appareils
numériques de classe B, selon la partie 15 des règles de la FCC. Ces limites
permettent d'assurer une protection raisonnable contre les interférences
nuisibles dans une installation résidentielle. Cet équipement produit, utilise et
émet de l'énergie radio fréquence, pouvant causer des interférences nuisibles aux
communications radio en cas d'installation ou d'utilisation non conforme aux
instructions. Toutefois, ces instructions ne garantissent pas l'absence
d'interférences pouvant se produire dans certaines installations.
Si cet équipement cause des interférences nuisibles à la réception de la radio ou
de la télévision, ce qui peut être vérifié en éteignant et rallumant l'appareil,
l'utilisateur est conseillé de :
- Réorienter ou déplacer l'antenne de réception;
- Augmenter l'espace de séparation entre l'équipement et le récepteur;
- Consulter le revendeur ou un technicien radio / TV expérimenté.
Warning (IC RSS-GEN, Sec 8.4):
This device complies with Industry Canada license-exempt RSS standard.
Operation is subject to the following two conditions:
- This device may not cause interference;
- This device must accept any interference, including interference that may
cause undesired operation of the device.
Avertissement (IC RSS-GEN, Sec 8.4):
Le présent appareil est conforme aux CNR d'industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes:
- L'appareil ne doit pas produire de brouillage;
- L'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
Issue 1.2, 06 January 2017Confidentialix
IntroductionTetraNode Base Station System
Warning (IC RSS-102, Sec 2.6):
This TETRA base station emits radio frequency (RF) energy when transmitting.
Make sure to observe all RF energy exposure standards when installing, testing
and operating this radio equipment.
Proper operation of this TETRA base station under normal conditions results in
user exposure to RF energy below standard acceptable limits.
Do not allow the antenna to touch or come in very close proximity with the
eyes, face, or any exposed body parts while the TETRA base station is
transmitting.
Avertissement (IC RSS-102, Sec 2.6):
Cette station de base TETRA émet de l'énergie radiofréquence (RF) lors de la
transmission. Assurez-vous d'observer toutes les normes d'exposition à l'énergie
RF lors de l'installation, de l'essai et de l'utilisation de cet équipement radio.
Le bon fonctionnement de cette station de base TETRA dans des conditions
normales entraîne une exposition de l'utilisateur à une énergie RF inférieure aux
limites acceptables habituelles.
Ne permettez pas à l'antenne de toucher ou de se trouver très près des yeux, du
visage ou des parties du corps exposées pendant que la station de base TETRA
transmet.
Issue 1.2, 06 January 2017Confidentialx
IntroductionTetraNode Base Station System
Caution:
Service and /or maintenance of this equipment should only be carried out by
qualified and trained service technicians/personnel. Ensure cabinet and/or
equipment room is kept locked.
Attention:
Le service et/ou la maintenance de cet équipement ne doivent être effectués que
par les techniciens/personnel de service qualifiés et formés. Assurer-vous que
l’armoire et/ou la salle d'équipements sont bien verrouillées.
Caution:
This equipment is designed to transmit and receive RF signals for which a
license is normally required. Although the equipment complies with the
manufacturing requirements for such equipment, it is the responsibility of the
customer to obtain a suitable license and to ensure that local requirements and
compatibility issues are complied with.
Attention:
Cet équipement est conçu pour transmettre et recevoir des signaux Fréquence
Radio pour lesquels une licence est normalement requise. Bien que
l'équipement soit conforme aux exigences de fabrication requises pour un tel
équipement, il est de la responsabilité du client d'obtenir une licence adaptée, et
de s’assurer de la conformité envers les exigences locales et celles de
compatibilité.
Caution:
When testing a running base site, consider first the impact on users before
disconnecting equipment!
Attention:
Lors de l’exécution de tests sur un site de base opérationnel, évaluer l'impact
sur les utilisateurs avant de débrancher l'équipement !
Issue 1.2, 06 January 2017Confidentialxi
IntroductionTetraNode Base Station System
Caution:
The calibration of the crystal reference in the TBS-SYN can be detuned by
mechanical shock. References so affected must be reconnected to a GPS signal
until auto-calibration has settled and corrected any errors.
Attention:
L'étalonnage du cristal de référence du TBS-SYN peut être désaccordé par choc
mécanique. Les références ainsi touchées doivent être reconnectées à un signal
GPS jusqu'à ce que l’auto-étalonnage soit terminé et les erreurs corrigées.
Caution:
The transmitter output and receiver input filters are qualified by Rohill for their
high performance and form part of the output filtering circuit. They must not be
replaced with alternatives nor be manually re-tuned.
Attention:
Les filtres de sortie de l'émetteur et d'entrée du récepteur sont qualifiés par
Rohill pour leur haute performance et font partie du circuit de filtrage de sortie.
Ils ne doivent ni être remplacés ni être manuellement réglés.
Caution:
12VDC is present on the receiver inputs of the R-8070. Do NOT short circuit
the receiver inputs. Do NOT connect receivers to test equipment without a DC
block.
Attention:
12VDC est présent sur les entrées du récepteur du R-8070. Ne PAS courtcircuiter les entrées du récepteur. Ne PAS connecter de récepteurs à
l'équipement de tests sans un bloc DC.
Issue 1.2, 06 January 2017Confidentialxii
IntroductionTetraNode Base Station System
Caution:
All unconnected connectors should remain unconnected unless otherwise stated
by Rohill. Unconnected connectors inside a BSS do not require any termination
either by design or by function.
This statement is not applicable for connectors meant for external connections
such as the ANT (antenna) output of combiners, power supply.
Attention:
Tous les connecteurs non connectés ne devraient PAS être connectés sauf
indication contraire de la part de Rohill. Les connecteurs non connectés à
l'intérieur d'un BSS ne nécessitent aucune terminaison ni de par leur conception
ni de par leur fonction.
Cette déclaration n'est pas applicable pour les connecteurs conçus pour des
connexions externes tels que la sortie ANT (antenne) vers les multiplexeurs ou
vers une source d'alimentation.
This manual covers the R-8070 based TetraNode Base Station System. Available
options, a technical description and guidelines for its installation, operation and
maintenance are provided.
This manual covers all available frequency band variants and standard
configurations. Special configurations and external components such as power
back up systems and back-haul networks are not covered by this manual.
Guidance notes (for information) are written in italics.
Where specifications are given, these are for illustration as they may be subject to
change. The definitive figures should be checked on the appropriate product data
sheet.
The R-8070 transceiver MUST be operated in combination with the supplied
antenna combiner system. i.e. The antenna filters, combiners and low noise
amplifier are now part of the transceiver.
1.2 Base Station System overview
A TetraNode Base Station System is designed to provide the radio frequency
carriers for one TETRA base site. As standard it consists of one cabinet
containing one to four R-8070 transceivers and all the associated cabling, antenna
combining, synchronisation unit(s), optional fall-back site controller, line
interfacing and optional power supplies.
All Rohill Base Stations are supplied fully assembled and tested. It remains only
for antenna connections, power and system (network) connections to be made.
Issue 1.2, 06 January 2017Confidential16
TetraNode Base Station System
2System Options
2.1 Number of carriers
The standard number of carriers per cabinet is two or four. However cabinets can
be sub-equipped for one or three carrier configurations. If more than four carriers
per site are required, then multiple cabinets should be co-located.
2.2 Cabinet
The standard R-8070 Base Station System (1 to 4 carriers) is supplied in a
1670mm high (32U internal) 19” rack unit. 600x600mm footprint with lockable
front and rear doors. Colour light grey (RAL 7047). Front door is solid. Rear door
is ventilated (exhaust air) top and lower/middle. Main air inlet is under rack, main
air exhaust is lower/middle of rear door.
2.3 Power supply
The standard R-8070 Base Station System is supplied from a single +24V
(nominal) DC connection. DC range is 18-36VDC negative earth. 3 and 4 carrier
systems are dual-redundant supply as standard. Switching power control and
backup (e.g. UPS) must be provided separately and externally. Supply options are
available for:
•18-36VDC (nominal +24VDC) negative earth
•AC mains. Input range 100-240VAC 50/60Hz
The system is also prepared for 36-58VDC (nominal -48VDC) positive earth –
please enquire. Configurations can be:
The R-8070 transceivers are each supplied from their own AC/DC PSU. For true
redundant operation two power supply input connections are required. Normally,
each input will power half of the equipment in the rack.
Figure 2, Dual redundant power supply, 2-4 carriers
2.4 Frequency bands
The transceiver unit(s) used in the system have a fundamental tuning bandwidth of
20MHz. The transmitter and receiver can be independently tuned anywhere in this
range subject to permitted configurations [see ETSI TS 100 392-15].
Below 500MHz, this range is further constrained by the antenna filtering solution
to a pair of 5MHz sub-bands (normally 10MHz duplex offset). Above 500MHz,
with 45MHz duplex split, the full band is covered by one antenna system variant.
Standard duplex split is 10MHz when below 500MHZotherwise 45MHz. Other
duplex offsets are possible, but may be specials – please enquire. Reverse
operation is possible on all bands below 500MHz.
2.5 Transmitter output power
All powers are quoted as continuous rated RMS values. The maximum output
power of the R-8070 transceiver (before antenna combining) is +46dBm rms
(approx 40W). Lower powers (1dB steps down to 33dBm (2W)) are configured in
software.
Note: the approximate loss of a 2:1 hybrid + duplexer/Tx-filter is 4dB.
Issue 1.2, 06 January 2017Confidential18
PSU
R-8070
PSU
R-8070
PSU
R-8070
IP SWITCH, RMC etc.
DC
Dual
power
inputs
R-8070
PSU
BSS Cabinet
Optional
carriers
Optional
AC/DC PSUs
IP SWITCH, RMC etc.
Simplified diagram
TetraNode Base Station System
2.6 TBS-SYN Timing reference
The R-8070 site always contains at least one timing reference. This can be either
with or without GPS receiver. Note - Seamless handover is only supported when
the system is locked to GPS. A second reference is fitted for dual-redundant
operation. The timing reference is normally powered from the R-8070
transceiver(s). Dual power inputs are available for sites with partial redundancy.
Specify if required. Timing references without GPS are factory calibrated against
GPS. They are designed to run for 10 years within specification.
Caution:
The calibration of the crystal reference in the TBS-SYN can be detuned by
mechanical shock. References so affected must be reconnected to a GPS signal
until auto-calibration has settled and corrected any errors.
Attention:
L'étalonnage du cristal de référence du TBS-SYN peut être désaccordé par choc
mécanique. Les références ainsi touchées doivent être reconnectées à un signal
GPS jusqu'à ce que l’auto-étalonnage soit terminé et les erreurs corrigées.
Issue 1.2, 06 January 2017Confidential19
TetraNode Base Station System
2.7 Line Interface(s)
The standard for connecting TetraNode Base Station Systems to the back-haul
network (modems) is Ethernet 10/100baseT.
1 – 2 carrier systems contain one switch.
Figure 3, 1-2 carriers, FSC option, single switch
3 – 4 carriers systems are offered with a second switch for dual redundancy. A
second set of IP addresses are used in the redundant case.
Figure 4, 2-4 carriers, Dual line option, dual switches
Issue 1.2, 06 January 2017Confidential20
Fallback controller
Simplified diagram
Single IP/
Ethernet
input
Options
BSS Cabinet
R-8070
R-8070
IP
switch
Simplified diagram
Dual IP/
Ethernet
input(s)
Options
BSS Cabinet
R-8070
R-8070
R-8070
R-8070
IP
switch
IP
switch
TetraNode Base Station System
2.8 Environmental
The BSS is designed for operation in a dry weather protected and vibration-free
location. Exposure to solar radiation should be limited. High humidity can be
tolerated, but MUST be non-condensing conditions. Air conditioning is only
required if the performance envelope of the equipment inside the rack would
otherwise be exceeded. However, improved life time and performance will be
achieved if temperature is kept below extremes. Temperature performance of the
carriers is defined at the air-intake of the transceiver sub-rack.
Issue 1.2, 06 January 2017Confidential21
TetraNode Base Station System
3Technical description
3.1 R-8070 transceiver
3.1.1 Transceiver User Interface (MMI)
The User Interface or Man-Machine Interface (MMI) is provided by a 4.3 inch
full-colour LED-backlit touch-screen LCD display mounted in the front panel see
Figure 5.
Figure 5, R-8070 transceiver front view
Status, error-codes, heart-beat, configuration and diagnostic/test information can
be shown.
After a time-out the display will revert to a screen-saver mode. This can be
disabled.
3.1.1.1 MMI operation
At power-up the touch-screen MMI will initially show a TetraNode splash screen
whilst the carrier is booting up.
The display will then directly enter the System Settings sub-screen:
Figure 6, R-8070 MMI generic screen layout
Issue 1.2, 06 January 2017Confidential22
TetraNode Base Station System
The generic layout of each sub-screen is:
Touching the screen anywhere in the information area will return the user to the
top level screen:
Figure 7, R-8070 MMI Top-level screen
This screen has three navigation buttons and one button (bottom right) to toggle
screen-save on/off. When enabled, the display (default) will enter a screen save
mode after a time-out period of 60 seconds (10 seconds if after clearing an alarm).
The screen saver is a left-scrolling image:
touching the screen will exit screen-save and return to the last viewed screen.
Issue 1.2, 06 January 2017Confidential23
Information area
Screen titlesystem-time
Indicators
Information
Tab-keys
TetraNode Base Station System
The navigation keys correspond to the three sub-screens described below.
3.1.1.2 Menu Map
The top level menu (Figure 7) presents three choices. The categories within each
of these then operate as a “tab” selection, i.e. the selected sub-sub-category is
highlighted with a blue tab-key.
Top Level ------
select one of the following three categories:
SETTINGS ---
System
serial number
uptime (days hours:minutes)
Firmware version
I/O FPGA version
Rx/Tx FPGA version
Primary SYN1 serial number
Secondary SYN2 serial number
IP address
Channel
Frequency band (3|4|8)
Channel number
Frequency offset (-6.25kHz|0kHz|
+6.25kHz|+12.5kHz)
Duplex spacing
Reverse operation (yes|no)
Transmit frequency (MHz)
Receive frequency (MHz)
Network
Mobile country code
Mobile network code
Base-station colour code
TNX (name, description)
Rx/Tx
Receive diversity (on|off,on|off,on|off)
Transmitter standby timeout
PA temperature limits (warning/abs-
max)
Power level
Issue 1.2, 06 January 2017Confidential24
TetraNode Base Station System
Alarm
list of alarms & warnings
-see section 6.2
STATUS ---
Controller
uptime (days hours:minutes)
Connection (TNSP | IP-Link)
TNX (name, description)
card temperature (C)
Receiver
RSSI value (dBm) by time-slot and
receiver
uplink assignment summary (1 row)
scrolling histogram of received data
black – unallocated
blue – control-channel
yellow – traffic
card temperature (C)
Transmitter
Output (W)
scrolling histogram of transmitted slot
types
PA temperature (C)
Tx card temperature (C)
PSU
input voltage (V)
card temperature(C)
Alarm
list of alarms & warnings
-see section 6.2
SYSTEM ---
IP address (when empty DHCP used)
Issue 1.2, 06 January 2017Confidential25
TetraNode Base Station System
[keypad}, <backspace> and <enter>
keys for setting:
IP address
network mask
Default gateway
Reset
press both buttons (sequentially),
within 1 second, to reset the carrier.
Caution:
Please note that if this soft-button is used during normal operation it will cause
an interruption of service to the users.
Attention:
Veuillez noter que l’utilisation de ce bouton programmable pendant le
fonctionnement normal provoquera une interruption de service pour les
utilisateurs.
Alarm
list of alarms & warnings
-see section 6.2
3.1.1.3 MMI status indicators
There are five indicators on the right hand side of the display. These have the
following meanings:
(green) Reserved for future use
(black/red) ALARM indicator
(black/blue) Tx ON indicator
(black/yellow) Rx ACTIVE
(black/green) CONNECTED to TNX or ber-test, (white) LOCAL
Issue 1.2, 06 January 2017Confidential26
TetraNode Base Station System
3.1.2 Transceiver Alarms and Warnings
If an alarm state occurs, the Alarm tab-key is highlighted red. An alarm is
something that is critical to continued operation, e.g. will/has caused failure.
If a warning state occurs, the alarm tab-key is highlighted yellow. A warning is
something that affects performance but is non-critical e.g. temperature unusually
high. In normal operation, the alarm tab-key is black or blue(selected). For a full
list of alarms & warnings see section 6.2 If the transceiver is in screen-saver
mode, the display will “wake-up” when an alarm or warning occurs.
3.2 Synchronisation TBS-SYN
The TBS-SYN provides a high stability reference clock from a precision ovencontrolled oscillator. Once calibrated, this oscillator will stay within specification
for ten years or more. However free-running systems (no GPS antenna) should be
periodically checked for accuracy in case of mechanical shock or other detuning.
Fitting the GPS receiver antenna is strongly recommended. GPS satellite timing
signals provide a master reference to phase lock and auto-calibrate the ovened
crystal reference. GPS reception is essential for systems supporting seamless
handover.
One unit can synchronise up to 16 transceivers. Two units are fitted in dualredundant system designs. Connections to transceivers are made with star
connected RJ-45 cables. Power and timing-reference cables are <3m to comply
with EMC requirements.
The TBS-SYN is designed to be powered from one or two R-8070 base station
transceivers. The second power cable is only fitted as a special as it is only
required by partially redundant systems. E.g. in the case that one TBS must be
removed without disabling the other(s).
A TBS-SYN contains one GPS receiver with a 3.3V DC power output on the
receiver MCX connector for powering a remote active antenna. The antenna and
lightning protection must guarantee a DC feed with no short circuit to the active
antenna.
Management and GPS signal quality information is available to the network via
the transceiver control.
Issue 1.2, 06 January 2017Confidential27
TetraNode Base Station System
3.3 Connections
3.3.1 R-8070 connections
3.3.1.1 IP connections
In normal systems standard Ethernet network components can be used. However
some basic checks should be made:
First make sure that the Ethernet backbone is a dedicated service with a high
degree of reliability, say at least an availability of >99.99%. Virtual private
networks over the Internet may be cost effective, but are unreliable, especially
considering the packet delay and jitter.
Secondly, it is desirable to use a Quality of Service mechanism using DiffServ,
also called Differentiated Services Codepoint (DSCP). This allows the operator to
carry different classes of traffic over the IP network, the service for connecting
TetraNode base stations will use Expedited Forwarding mode. Make sure this is
supported.
3.3.1.2 Transmit Antenna connector
The female-N-type Tx power connector at the rear of the transceiver has a 50 Ω
unbalanced characteristic impedance. It is connected to the antenna system with a
good quality flexible double screened coaxial cable.
The transmitter antenna system should always provide at least 80dB transmit to
receive isolation. Therefore always ensure good connections and maximise RxTx cable separations.
Isolators are built-into 20MHz bandwidth PAs as standard, thus the R-8070 is
suitable for multi-Tx sites without supplementary intermodulation protection.
Extra isolators are also present in the hybrid or cavity combiners.
There is a red-LED next to the output connector. Do NOT remove the
antenna/load if this is lit.
Issue 1.2, 06 January 2017Confidential28
TetraNode Base Station System
Caution:
transmitter cables are often critical lengths and should not be cut or mixed up.
This is especially true for cavity combiners.
Attention:
Les câbles de l'émetteur ont souvent des longueurs critiques, et ne doivent pas être
coupés, ni mixés. Cela est particulièrement vrai pour les multiplexeurs de cavité.
3.3.1.3 Receiver Antenna connectors
The three female snap fit QMA receiver antenna(s) connectors at the rear have a
nominal 50 Ω unbalanced characteristic impedance. All three inputs are
equivalent. To provide diversity gain, connect the receivers to physically
separated antennas. Ideal diversity separation 7 to 10 lambda (wavelengths). For
best performance, diversity antennas should be at the same height (so that they
receive comparable average powers)
If multiple R-8070s are used on one site, then received signals are normally split
with a Receiver Multi-Coupler. The amplifier in the Coupler must have noise
figure and OIP3 performance similar to the R-8070 in order to preserve
performance.
On sites with strong signals from other systems, ensure that the receiver amplifier
is far from overload. A band limiting filter (pre-selector) should always be fitted
(usually part of receiver multi-coupler or duplex filter).
Transmit-receive isolation should exceed 80dB. Use double-screened coax and
maximize physical separations between Rx-Tx (e.g. dress cables on opposite side
of the rack).
Unused receivers should be disabled (see configuration) to optimize system
performance.
3.3.1.4 Synchronization inputs
The reference frequency and synchronization data from the TBS-SYN enters the
R-8070 via the SYNC input connector. The spare input is for use in dualredundant systems.
The R-8070 is designed for a (dual) star connection of synchronisation clocks.
Issue 1.2, 06 January 2017Confidential29
TetraNode Base Station System
3.3.1.5 RS-232 / DE-9 connector
An asynchronous RS-232 serial port is available on the DE-9 connector.
This connector is intended only for testing and alignment of the R-8070 during
manufacturing, and cannot be used during normal operation and maintenance.
3.3.1.6 Protective earth
One of the rear panel mounting screws should be connected to the rack protective
ground with a short heavy-gauge cable (minimum cable 7/0.85 mm (4 mm2)). To
minimise inductance, this cable should NOT be looped/ coiled as it is to provide
operator and equipment protection from fast transients and surges. The equipment
rack/housing in turn should use a heavier gauge cable/strap to connect to the
communications room protective earth.
If in doubt, consult an expert on lightning protection.
Warning:
The protective earths within the TetraNode Base Station should be adequately
bonded to the electrical earth of the 19” rack cabinet and NOT to any lightning
protection system for transmitter-towers/antennas.
Avertissement:
Les protections de mise à la terre de la station de base TetraNode doivent être
adéquatement jointes à la mise à la terre de la grille 19" de l'armoire et NON au
système paratonnerre des pylônes d’émission/d'antennes.
3.3.2 R-855 TBS-SYN rear panel layout
Figure 8: TBS-SYN rear panel connector layout
IN 1
IN 2
RS232
I/O
LEDs
GPS
Synchronisation outputs 1..16
3.3.2.1 Connector Details
LabelDescription
IN 1, IN 2Twin DC power inputs 12-13.8V
RS-232 (DE-9) Connector for RS-232 diagnostics - factory only
Issue 1.2, 06 January 2017Confidential30
TetraNode Base Station System
LabelDescription
I/OInput/Output (DB-25) connections for 3rd party anciallries etc.
{pin-out definition required}
LEDsPWRPower on (green)
ALRMAlarm present (red)
PPSPulse per second (green)
GPS#GPS locked (yellow)
GPSFemale MCX connector with +3.3VDC on centre pin for GPS
active antenna.
Sync out 1..16RJ45 x 16 Synchronisation outputs
Connect earth cable with ring termination under one of the rear
panel screws
Issue 1.2, 06 January 2017Confidential31
TetraNode Base Station System
4Installation and configuration
The initial alignment and calibration (and if required, factory acceptance testing)
of the units is performed in the factory. This section describes the installation after
delivery. The cabinets are shipped fully equipped and ready for use. The basic
sequence for installation should be:
1. antenna earths and lightning protection
2. equipment room earths (separate from (1))
3. antennas and cables
4. equipment room power-supplies and lighting
5. cabinet placement
6. cabinet earths
7. antenna connections
8. network connections
9. cabinet power connections
10. configure, test and commission (include updating site documentation)
Warning:
Ensure that cables do NOT lie across any sharp metal edges. This applies to
ALL cables of all types.
Avertissement:
S'assurer que les câbles ne se trouvent PAS sur des bords métalliques tranchants.
Cela s'applique à TOUS les câbles de TOUS types.
4.1 Equipment room requirements
Equipment must always be operated in a secure manner – i.e. with locked doors
and/or in locked “authorised access only” areas. Thus, if possible, choose
equipment room locations that are secure, but do not require extra special
permissions/training for personnel requiring access (e.g. intrinsic safe areas in oil
refineries or hygiene restrictions of drinking-water towers).
All standard TetraNode variants are designed for installation in a weather
protected (dry) environments, i.e. an equipment room, except for some specials,
such as the “ultra-lite” and transportable cabinets
Issue 1.2, 06 January 2017Confidential32
TetraNode Base Station System
In all cases, humidity may be high, but must be non-condensing. Condensation
may be prevented by keeping equipment temperatures higher than circulating air
temperature. Consider the likelihood of rapid rises in air temperature that may
leave equipment (with high thermal mass) temporarily at a lower temperature.
In the equipment room, ensure that temperature remains within the maximum and
minimum operating-limits of the equipment in use. This is usually defined with
respect to the (ambient) air inlet of the component in question. It may be
necessary to consider the effects of closed cabinet operation and (for specials)
ancillary equipment that may be mounted in the rack.
Requirements for air conditioning (chillers) can usually be avoided due to the
wide operating range for TetraNode equipment, thus saving considerably on
running costs. NB Low temperature operation will generally lead to longer
equipment life.
The equipment room should be dry and relatively dust free (clean) and vermin
free. For all other environments, the equipment should be fitted in an appropriate
environmental housing.
4.1.1 Equipment-room earth
The equipment room should have its own low-impedance protective earth system
separate from that of the antenna tower. All incoming/outgoing cables should also
be protected (earthed) at the entry point to the equipment room.
Equipment room earth should ideally be constructed as a “halo” over the
equipment with connections to ground at the corners. This effectively creates a
Faraday cage over and around the equipment.
Warning:
Do not connect equipment-room earth to the same earth used for the tower
lightning protection.
Avertissement:
Ne PAS connecter la prise de terre de la salle d’équipements à la même prise de
terre du paratonnerre de la tour.
When sited near railways also consider extra shielding from magnetic fields and
anti-vibration mounts for equipment.
Issue 1.2, 06 January 2017Confidential33
TetraNode Base Station System
4.2 Installation – floor standing cabinets
Standard R-8070 Base Station configurations are supplied in a 37.5U 19” floor
standing cabinet (600x600mm footprint) with supporting shelves or slide rails.
The system components are held in the rack by M6 (pozidrive) screws.
The cabinet is designed for internal-cable access at the rear and normal
operation/monitoring from the front.
External cables can enter either through the cabinet floor or the lid.
The rack is supported on four feet, but also has two wheels at the front for easy
installation. When in position, wind the feet down to equalise the support and
level the cabinet.
Ensure that the rear panel can be lifted off if required and the associated earth
strap can be removed/replaced without damage.
Ensure that the cabinet will be adequately lit when being worked on. NB. Doors
are hinged on the left.
Ensure the earth is connected first.
4.2.1 Ventilation and cooling
Cool air is required at the front/underside of the R-8070 cabinet. Hot air is
exhausted at the rear/top. Ensure that hot air is NOT recirculated into the inlet.
Sufficient ventilation to remove typically 190 W per carrier (on full power) and
worst case 250 W should be provided. Typically an area of 2 x (15 cm x15 cm)
per carrier should be sufficient for the inlets and outlets respectively.
Allow extra ventilation for cooling of hybrid combiner, power supplies, fall-back
site controller, IP-switch and TEP-rack, as required.
Ensure that the installation location is clean to prevent build up of dust in the
ventilation grills. Ventilation ducts should be screened with a thin mesh of ~1 cm
to keep vermin/debris out and yet not get clogged with dust.
Issue 1.2, 06 January 2017Confidential34
TetraNode Base Station System
4.3 Power-supply and Earthing
Warning:
All power installations must additionally comply with all local wiring
regulations.
Avertissement:
Toutes les installations d’alimentation doivent en outre se conformer aux
régulations locales de câblage.
Warning:
The cabinet(s) must be supplied via READILY ACCESSIBLE power switch(es).
Avertissement:
Les armoires doivent être équipées d’interrupteur(s) d'alimentation facilement
accessible(es).
Warning:
If dual power supplies are used for redundancy, ensure warnings are clearly
posted on the cabinet and double circuit isolators are provided. Each isolator
must be double-pole, with certified breaking capacity and voltage rating suitable
for the cabinet version in question.
Avertissement:
En cas d’utilisation de deux sources d'alimentation dans un but de redondance,
prendre soin d’afficher clairement les avertissements sur l’armoire et de fournir
une isolation double circuit. Chaque isolateur doit être en double-pole, avec une
capacité de rupture certifiée et une tension nominale convenant à la version de
l’armoire en question.
Warning:
The protective earth point within the TETRA Base Station cabinet should be
adequately bonded to the electrical earth of the 19” rack cabinet and NOT to any
lightning protection system for transmitter-towers/antennas.
Issue 1.2, 06 January 2017Confidential35
TetraNode Base Station System
Avertissement:
Le point de mise à la terre de l'armoire de la station de base TETRA doit être
adéquatement joint à la mise à la terre de la grille 19" de l'armoire et NON au
système paratonnerre des pylônes d’émission/d'antennes.
Warning:
If connecting to floating power supplies take care to minimise touch-currents.
Correctly earthed supplies are preferred over floating supplies.
Avertissement:
Lors d’une connexion à une source d’alimentation instable, prendre soin de
minimiser les fuites de courant. A privilégier les sources fixes d’alimentation,
correctement mises à la terre.
4.3.1 Earthing
Firstly - All cabinets must first be permanently cross-bonded (connected)
to the protective earth point(s) to protect operators from dangerous
surges and possible touch currents from 3rd party equipment. Use only a
single star connection point. Max cable length 2m. Use double crimped or
soldered and strain-relieved ring terminals, do not use spade terminals.
Earth connections must be low impedance (minimum cable cross section MUST
exceed that of the (total) supply cable. In any case minimum 7/0.85 mm cable (4
mm2) per two carriers.
Once the protective earth connection is made, other work may proceed.
If multiple cabinets are installed, independently star-connect them to the safety
earths.
If third party equipment (e.g. power supplies, line equipment) are used, check that
the touch currents (leakage to ground) will not accidentally trip building RCDs
(residual current breakers).
4.3.2 AC Power cables
All cables must be installed so as to avoid abrasion (wear) and other forms of
damage. Do not run cables over any unprotected metal edges.
Issue 1.2, 06 January 2017Confidential36
TetraNode Base Station System
The AC power cable must use conductors with cross sectional area ≥1.25mm2 per
cabinet. Use only (marked) certified cable types (tested for safety and compliance
with ratings).
Supplied power cables can be directly connected into isolation switches. Always
switch both live and neutral (or in a DC system + and - ). Switches MUST be
located in a readily accessible location.
Dual power supply installations must be clearly labelled and equipped with dual
circuit isolators. Each isolator must be double-pole, with certified currentbreaking capacity and voltage rating suitable for the cabinet version in question.
4.3.3 DC Power cables
A low impedance DC power supply should be connected to the transceiver power
supply input connector (two pins only). The connector is a Phoenix type and is
available from Rohill or your Rohill distributor. Use colour-coded multi-strand
cable with a minimum cross-section of 2.0 mm2 per transceiver for the power
supply. All cables should be insulated and be strain relieved as a short circuit
could cause a fire hazard. If long cables are used (>1.5m), compensate for voltage
drop and protect against transients and surges. Maximum cable length 3m.
Power cables with 7/0.85 mm (4 mm2) cross section with conductors are suitable
for one pair of carriers.
A cabinet with 3 or 4 carriers is designed for double cables, 2 positive and 2
negative cables because the single cable alternative would be more than twice as
heavy. Supply redundancy is therefore standard for 3 and 4 carrier configurations.
4.3.4 Power supply
Ensure the power supply is capable of providing more than the rated power of the
cabinet under all conditions, allowing also for turn-on surges.
If necessary protect equipment from brown-out (voltage dip), over-voltage and
supply failures.
Although the power inputs are protected against transients and surges, if
connecting to an alternator or generator system (especially a vehicular/generator
power supply) care must be taken to provide additional filtering of
noise/transients.
4.4 Network Connections
IP over Ethernet requires 50 kbps bandwidth per R-8070.
In either case, total delay to the TNX should not exceed 20ms. If it does, the
system will still work, but PTT delays will be increased. Also ensure that the jitter
is kept below 4 ms to minimise buffer sizes.
Issue 1.2, 06 January 2017Confidential37
TetraNode Base Station System
The IP address(es) for the transceiver can be entered via the front panel LCD.
4.5 Antenna system
4.5.1 Lightning protection
Warning:
The reader is advised to seek specialist advice on this subject1. Rohill accepts no
liability for failure of designs that may be based upon the following advice!
DO NOT WORK ON OR TOUCH ANY SYSTEM WHEN LOCAL
ELECTRICAL STORM ACTIVITY IS PRESENT.
Avertissement:
Il est recommandé au lecteur d'obtenir des conseils spécialisés sur ce sujet
1.
Rohill n'accepte aucune responsabilité en cas d’échec de conception qui peuvent
être fondés sur le conseil suivant !
NE JAMAIS TRAVAILLER OU TOUCHER N'IMPORTE QUEL SYSTÈME
EN CAS D’ORAGE VOISIN/LOCAL.
A correctly designed lightning protection system can protect a radio transmitter
from the effects of most direct strikes. Adding effective protection to a system
after initial installation can be considerably more difficult, therefore consider
lightning protection requirements from the outset of system design.
Lightning protection components are not supplied as standard and are the
responsibility of the antenna-site engineer.
1
Issue 1.2, 06 January 2017Confidential38
TetraNode Base Station System
4.5.2 Minimization of exposure to non-ionizing radiation
Warning (IC RSS-102, Sec 2.6):
This base station emits radio frequency (RF) energy when transmitting. Make
sure to observe all RF energy exposure standards when installing, testing and
operating this radio equipment.
Proper operation of this base station under normal conditions results in user
exposure to RF energy below standard acceptable limits.
Do not allow the antenna to touch or come in very close proximity with the
eyes, face, or any exposed body parts while the base station is transmitting.
The warnings in this document are not intended to include all hazards that may
be encountered when using this base station.
Avertissement (IC RSS-102, Sec 2.6):
Ce station de base émet des fréquences radio (RF) lors de la transmission.
Assurez-vous de respecter toutes les normes d'exposition à l'énergie RF lors de
l'installation, les essais, la réparation et l'utilisation de ce matériel radio.
Le bon fonctionnement de station de base dans des conditions normales entraîne
l'exposition de l'utilisateur à l'énergie RF en dessous des limites du standard
acceptables.
Ne pas laisser l'antenne entrer en contact ou à proximité des yeux, du visage ou
des parties du corps exposées lorsque le station de base transmet.
Les avertissements contenus dans ce document ne vise pas à inclure tous les
dangers qui peuvent survenir lorsque vous utilisez cette station de base.
In Europe, in order to comply with Council
Recommendation 1999/519/EC on "Limitation of
exposure of the general public to electromagnetic fields
(0 Hz to 300 GHz)" the following actions should be
performed for every new or re-engineered transmitter
site.
Figure 9,
Non-ionizing radiation warning
•As a minimum, the commissioning engineer should perform a calculation
to show that the general public will not be exposed to electromagnetic
fields in excess of the recommended levels. This calculation is to be signed
and stored with the commissioning documentation file for the site.
Issue 1.2, 06 January 2017Confidential39
TetraNode Base Station System
As an alternative to calculation, a measurement may be made to
demonstrate compliance in which case calibration details of measuring
equipment and measurement results should be recorded in the file.
•Where service/maintenance personnel require access to areas that will
exceed the levels stated for exposure of the General Public, non-ionizing
radiation warning signs are to be displayed (see Figure 9).
Warning (IC RSS-GEN, Sec 8.3):
The BSS has been approved by the Industry Canada to operate with the antenna
types listed in the table below with the maximum permissible gain and required
antenna impedance for each antenna type indicated. Antenna types not included
in this list, having a gain greater than the maximum gain indicated for that type,
are strictly prohibited for use with this device.
Avertissement (IC RSS-GEN, Sec 8.3):
Le BSS a été approuvé par Industrie Canada pour fonctionner avec les types
d'antenne énumérés dans le tableau ci-dessous et ayant un gain admissible
maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal
indiqué, sont strictement interdits pour l'exploitation de cet émetteur.
Antenna
Manufacturer
Model nameFrequency range Maximum Permissible
Antenna Gain
Required
impedance
Antenne
Fabricant
Numéro de
modèle
Gamme de
fréquences
Maximum admissible Gain
d'antenne
Impédance
requise
Kathrein737 546410 - 430 MHz8 dBi50 Ω
Kathrein742 155450 - 470 MHz8.5 dBi50 Ω
Kathrein738 192806 - 894 MHz11 dBi50 Ω
Kathrein800 1043380 - 470 MHz14 dBi50 Ω
SinclairSC329-HT2LDF410 – 430 MHz6 dBd50 Ω
SinclairSC329-HF2LDF450 – 470 MHz6 dBd50 Ω
SinclairSC489-SF1LNF806 – 869 MHz9 dBd50 Ω
Issue 1.2, 06 January 2017Confidential40
TetraNode Base Station System
4.6 BSS Configuration
The configuration of the carriers in a TetraNode BSS is fully automatic once all
the necessary connections are made and the unit is powered on.
At power on, the BSS carriers announce themselves to the TNX. The R-8070
identities are captured by the TNX by means of the Plug and Play procedure. The
identities are matched against system configuration database and configuration are
sent to each unit. New (unknown) carriers will be automatically added to the
database and made visible in the NMS.
The manual for the NMS describes the exact procedure used to configure an
R-8070 carrier and also gives detailed information about the parameters.
In summary, the following parameters are sent to a BSS to configure a carrier:
•Channel number
(channel# = (frequency_in_MHz - Base_Frequency )/0.025)
where Base Frequency = 300, 400 or 800 MHz.
•Receiver selection (enable | disable), default= all enabled
To minimise received noise and reduce power consumption, unused Rx
inputs should be disabled.
The basic procedure is as follows:
1. Power-up the BSScabinet. The R-8070s announce to the TNX but the blue
Sync display marker is still off.
2. If required, a TETRA site must be created in the NMS. All parameters for
the site have a default value, which is sufficient in case of a single site
system. For a multi site system the parameters need to be configured to
enable handovers. Make sure the site is enabled.
3. Now the R-8070 carriers must be associated with site. Fill in the carrier
number and select the channel plan profile. Select the required output
power and enable the receivers to be used.
4. The carrier will now become enabled. The blue Sync display marker will
illuminate to indicate that the R-8070 is registered and enabled on the TX.
After a timeout only the heartbeat will be shown on the display to indicate
that the device is in service and ready to operate.
Issue 1.2, 06 January 2017Confidential41
TetraNode Base Station System
5Maintenance and replacement
5.1 General
This section describes the preventive maintenance actions for the TETRA Base
Station System. It also describes the replacement of the components within a BSS.
Defective units are replaced as a complete unit and repaired in the factory.
5.2 Maintenance policy
There are NO end-user or distributor serviceable parts within the components of a
TetraNode Base Station (such as an R-8070 or R-855 TBS-SYN). Spare parts are
complete sub-rack components.
Spares holding and support requirements should be negotiated through your Rohill
representative.
The network connection(s) can be used for actions such as remote download of
software updates. The transceiver controller can hold multiple software versions
and permits synchronised network change-over between software versions.
5.3 Maintenance
The TetraNode Base Station System is designed as a maintenance-free
installation. No alignment is normally necessary during the lifetime of the
equipment. Also no consumables are necessary to keep the system in operation.
Preventive maintenance should include the following checks to ensure the system
is operating within specification limits. These tests can be performed from the
NMS. See the NMS user manual for detailed information how to obtain the
information.
•Check PA temperature (and fan speed); if this is significantly above
normal limits, the airflow may be obstructed.
•Check the RF output power of the R-8070. The measured power should be
within 2 dB of the selected RF output power. If the measured power is
outside these limits, first check whether the problem is caused by antenna
mismatch (fault). If not, the R-8070 should be replaced.
•To check for antenna system mismatch, check the reflected power. The
measured reflected power should be below 30% of the selected RF output
power. If the reflected power is higher, verify whether the antenna, coaxial
cables, duplexer and combining equipment are working/tuned correctly.
•Check the Alarm and Failure flags. If there are any reported errors, take
action to clear them as described in section Error codes R-8070.
Issue 1.2, 06 January 2017Confidential42
TetraNode Base Station System
6Troubleshooting
6.1 General
Caution:
Service and /or maintenance of the equipment should only be carried out by
qualified service technicians.
Attention:
Les services et/ou la maintenance de l'équipement ne doivent être effectués que
par des techniciens de service qualifiés.
Diagnostics are performed locally or remotely with appropriate software and
repair is by component replacement.
Fault find should be step by step to prove that each component of the system is
operating normally. Faults can often be isolated by swapping suspect units with
known good ones, however exercise care not to damage further equipment e.g.
due to faulty antenna or power connections.
6.2 R-8070 Alarm messages
The R-8070 executes continuous measurements on critical parameters such as
output power and level of linearization (which influences the quality of the
transmitted signal). Errors are indicated by means of error codes shown on the
front panel of the R-8070.
CodeDescriptionPossible remedy
A1No TNX connection1. Check TNSP (V.11) cable
2. Check if TNX / FSC is running
A2Base station disabled
A3IP data link failure1. Check IP connections
2. Check if TNX / FSC is running
A4R-8070 disabled for maintenanceContact distributor
Table 1, R-8070 error messages
Issue 1.2, 06 January 2017Confidential43
TetraNode Base Station System
7Specifications
7.1 General transceiver specifications
ParameterSpecification
ManufacturerRohill, http://www.rohill.com
TypeR-8070
Power supply voltage18 to 36 V
DC
(24 VDC nominal)
Power consumption per carrier
(excludes ancillary site equipment)