Rohill Engineering R 8070 800MHZ User Manual

Confidential
Manual
TetraNode Base Station System
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and countries with
separated waste collection systems).
This marking shown on the product or its literature indicates that it should not be
To promote the sustainable reuse of material resources and to prevent possible
harm to the environment or human health from uncontrolled waste disposal,
please separate this from other types of wastes and recycle it responsibly.
Users should contact either the retailer where they purchased this product, or their
local government office, for details of where and how they can send this item for
environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions
of the purchase contract. This product should not be mixed with other commercial
wastes for disposal.
© Copyright 2009-2017, Rohill Technologies B.V.
Issue 1.2, 06 January 2017 This version supersedes all previous versions. Please check you have the latest version before continuing.
Information in this manual is subject to change without notice and does not represent a
commitment on the part of the manufacturer. This manual is copyrighted; it may not, in whole
or in part, be copied, photocopied, translated, or reduced to any electronic medium or
machine readable form without prior consent in writing from Rohill Technologies B.V.
Rohill Technologies B.V. / Rohill Engineering B.V. Edisonstraat 12 7903 AN Hoogeveen The Netherlands Telephone: +31 528 263355 Telefax: +31 528 271844 Internet: www.rohill.com
Issue 1.2, 06 January 2017 Confidential ii
Introduction TetraNode Base Station System
Change history
Version Date Name Changes
V1.0 18-11-15 HW team FCC version of manual. FCC warnings added. V1.1 31-03-16 HW team Added warnings required by IC.
Translation of all warnings into French, as required by IC.
V1.2 06-01-17 HW team In “Warnings and cautions” added several warnings as
required by FCC and IC, including French translations. In 4.5.2 IC warning statements added, including French translations. In 4.5.2 Antenna types listed that can be used in combination with the BSS in Canada.
V1.3 29-03-17 TN team ITU emission designator updated from 18K to 22K to match
with the test reports.
Issue 1.2, 06 January 2017 Confidential iii
Introduction TetraNode Base Station System
Warnings and Cautions
Caution:
This manual contains important information concerning installation, maintenance and user instructions for the R-8070 based TetraNode Base Station.
Read the following pages before installing or using the equipment.
Attention:
Ce manuel contient des informations importantes concernant l'installation et la maintenance de la station de base R-8070 TetraNode, ainsi que les instructions destinées aux utilisateurs.
Bien lire ce manuel avant toute installation ou utilisation de l’équipement.
Warning:
This Equipment MUST be connected to a SAFETY EARTH.
Avertissement:
Cet équipement DOIT être connecté à une prise de terre.
Warning:
Do NOT operate the TetraNode Base Station without a suitable high-power 50Ω load(s) or correctly tuned antenna system being connected.
Avertissement:
Ne PAS faire fonctionner la station de base TetraNode sans une haute-puissance appropriée d’une charge de 50Ω ou sans une connexion à un système d'antennes correctement réglé.
Warning:
Do NOT touch or disconnect live (in use) antennas – RF energy can cause burns!
Issue 1.2, 06 January 2017 Confidential iv
Introduction TetraNode Base Station System
Avertissement:
Ne PAS toucher ni débrancher les antennes actives (en cours d’utilisation) ­L'énergie des fréquences radio peut causer des brûlures !
Warning:
Always ensure that the equipment is turned off before disconnecting antenna cables.
Avertissement:
Toujours s'assurer que l'équipement est éteint avant de débrancher les câbles de l’antenne.
Warning:
If working on a partially running site (half online), be careful of live power and RF connections.
Avertissement:
Si vous travaillez sur un site opérant partiellement (partiellement en ligne), faites attention à l'alimentation sous tension et aux connexions des fréquences radio.
Warning:
If connecting to floating power supplies take care to minimise touch-currents. Correctly earthed supplies are preferred over floating supplies.
Avertissement:
Lors d’une connexion à une source d’alimentation instable, prendre soin de minimiser les fuites de courant. A privilégier les sources fixes d’alimentation, correctement mises à la terre.
Warning:
If dual power supplies are used for redundancy, ensure warnings are clearly posted on the cabinet and double circuit isolators are provided.
Issue 1.2, 06 January 2017 Confidential v
Introduction TetraNode Base Station System
Avertissement:
En cas d’utilisation de deux sources d'alimentation dans un but de redondance, prendre soin d’afficher clairement les avertissements sur l’armoire et de fournir une isolation double circuit.
Warning:
Do not connect equipment-room earth to the same earth used for the tower lightning protection.
Avertissement:
Ne PAS connecter la prise de terre de la salle d’équipements à la même prise de terre du paratonnerre de la tour.
Warning:
Do NOT work on antenna cables or systems when there is any nearby/local electrical storm activity.
Avertissement:
Ne PAS travailler sur les câbles ou les systèmes des antennes en cas d’orage voisin/local.
Warning:
The protective earths within the TetraNode Base Station should be adequately bonded to the electrical earth of the 19” rack cabinet and NOT to any lightning protection system for transmitter-towers/antennas.
Avertissement:
Les protections de mise à la terre de la station de base TetraNode doivent être adéquatement jointes à la mise à la terre de la grille 19" de l'armoire et NON au système paratonnerre des pylônes d’émission/d'antennes.
Issue 1.2, 06 January 2017 Confidential vi
Introduction TetraNode Base Station System
Warning:
The power supply for the TETRA Base Station is low-voltage, but is nonetheless capable of delivering a hazardous energy level if short-circuited. Always disconnect the power before working on this equipment or connected systems.
Avertissement:
L'alimentation de la station de base TETRA est de basse tension, toutefois celle­ci est capable de fournir un niveau dangereux d'énergie si court-circuitée. Toujours débrancher l'alimentation avant de travailler sur cet équipement ou tout autre système connecté.
Warning:
All power installations must additionally comply with all local wiring regulations.
Avertissement:
Toutes les installations d’alimentation doivent en outre se conformer aux régulations locales de câblage.
Warning:
Do NOT fit 3rd party equipment into this cabinet. Operating the equipment with non-Rohill-approved components inside invalidates all warranties and may compromise your safety!
Avertissement:
Ne PAS monter un équipement de tierce partie dans cette armoire. L'exploitation de l'équipement avec des composants non approuvés par Rohill annule toute garantie et pourrait compromettre votre sécurité !
Warning (FCC Part 15.19):
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Issue 1.2, 06 January 2017 Confidential vii
Introduction TetraNode Base Station System
Avertissement (FCC Section 15.19):
Cet appareil est conforme à la section 15 des règles de la FCC (Commission fédérale des communications). Son fonctionnement est soumis aux deux conditions suivantes : (1) Cet appareil ne doit pas provoquer d'interférences nuisibles, et (2) cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant provoquer un fonctionnement indésirable.
Warning (FCC Part 15.21):
Rohill Engineering B.V. is not responsible for any changes or modification not expressly approved by the party responsable for compliance. Such modifications could void the user's authority to operate the equipment.
Avertissement (FCC Section 15.21):
Rohill Engineering B.V. n'est pas responsable de tout changement ou modification non expressément approuvés par la partie responsable de la conformité. De telles modifications peuvent annuler l'autorisation de l'utilisateur à faire fonctionner l'équipement.
Warning (FCC Part 15.105(b)):
The equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Consult the dealer or an experienced radio/TV technician for help.
Issue 1.2, 06 January 2017 Confidential viii
Introduction TetraNode Base Station System
Avertissement (FCC Section 15.105(b)):
Cet équipement a été testé et reconnu conforme aux limites des appareils numériques de classe B, selon la partie 15 des règles de la FCC. Ces limites permettent d'assurer une protection raisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement produit, utilise et émet de l'énergie radio fréquence, pouvant causer des interférences nuisibles aux communications radio en cas d'installation ou d'utilisation non conforme aux instructions. Toutefois, ces instructions ne garantissent pas l'absence d'interférences pouvant se produire dans certaines installations.
Si cet équipement cause des interférences nuisibles à la réception de la radio ou de la télévision, ce qui peut être vérifié en éteignant et rallumant l'appareil, l'utilisateur est conseillé de :
- Réorienter ou déplacer l'antenne de réception;
- Augmenter l'espace de séparation entre l'équipement et le récepteur;
- Consulter le revendeur ou un technicien radio / TV expérimenté.
Warning (IC RSS-GEN, Sec 8.4):
This device complies with Industry Canada license-exempt RSS standard. Operation is subject to the following two conditions:
- This device may not cause interference;
- This device must accept any interference, including interference that may cause undesired operation of the device.
Avertissement (IC RSS-GEN, Sec 8.4):
Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
- L'appareil ne doit pas produire de brouillage;
- L'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Issue 1.2, 06 January 2017 Confidential ix
Introduction TetraNode Base Station System
Warning (IC RSS-102, Sec 2.6):
This TETRA base station emits radio frequency (RF) energy when transmitting. Make sure to observe all RF energy exposure standards when installing, testing and operating this radio equipment.
Proper operation of this TETRA base station under normal conditions results in user exposure to RF energy below standard acceptable limits.
Do not allow the antenna to touch or come in very close proximity with the eyes, face, or any exposed body parts while the TETRA base station is transmitting.
Avertissement (IC RSS-102, Sec 2.6):
Cette station de base TETRA émet de l'énergie radiofréquence (RF) lors de la transmission. Assurez-vous d'observer toutes les normes d'exposition à l'énergie RF lors de l'installation, de l'essai et de l'utilisation de cet équipement radio.
Le bon fonctionnement de cette station de base TETRA dans des conditions normales entraîne une exposition de l'utilisateur à une énergie RF inférieure aux limites acceptables habituelles.
Ne permettez pas à l'antenne de toucher ou de se trouver très près des yeux, du visage ou des parties du corps exposées pendant que la station de base TETRA transmet.
Issue 1.2, 06 January 2017 Confidential x
Introduction TetraNode Base Station System
Caution:
Service and /or maintenance of this equipment should only be carried out by qualified and trained service technicians/personnel. Ensure cabinet and/or equipment room is kept locked.
Attention:
Le service et/ou la maintenance de cet équipement ne doivent être effectués que par les techniciens/personnel de service qualifiés et formés. Assurer-vous que l’armoire et/ou la salle d'équipements sont bien verrouillées.
Caution:
This equipment is designed to transmit and receive RF signals for which a license is normally required. Although the equipment complies with the
manufacturing requirements for such equipment, it is the responsibility of the customer to obtain a suitable license and to ensure that local requirements and compatibility issues are complied with.
Attention:
Cet équipement est conçu pour transmettre et recevoir des signaux Fréquence Radio pour lesquels une licence est normalement requise. Bien que l'équipement soit conforme aux exigences de fabrication requises pour un tel équipement, il est de la responsabilité du client d'obtenir une licence adaptée, et de s’assurer de la conformité envers les exigences locales et celles de compatibilité.
Caution:
When testing a running base site, consider first the impact on users before disconnecting equipment!
Attention:
Lors de l’exécution de tests sur un site de base opérationnel, évaluer l'impact sur les utilisateurs avant de débrancher l'équipement !
Issue 1.2, 06 January 2017 Confidential xi
Introduction TetraNode Base Station System
Caution:
The calibration of the crystal reference in the TBS-SYN can be detuned by mechanical shock. References so affected must be reconnected to a GPS signal until auto-calibration has settled and corrected any errors.
Attention:
L'étalonnage du cristal de référence du TBS-SYN peut être désaccordé par choc mécanique. Les références ainsi touchées doivent être reconnectées à un signal GPS jusqu'à ce que l’auto-étalonnage soit terminé et les erreurs corrigées.
Caution:
The transmitter output and receiver input filters are qualified by Rohill for their high performance and form part of the output filtering circuit. They must not be replaced with alternatives nor be manually re-tuned.
Attention:
Les filtres de sortie de l'émetteur et d'entrée du récepteur sont qualifiés par Rohill pour leur haute performance et font partie du circuit de filtrage de sortie. Ils ne doivent ni être remplacés ni être manuellement réglés.
Caution:
12VDC is present on the receiver inputs of the R-8070. Do NOT short circuit the receiver inputs. Do NOT connect receivers to test equipment without a DC block.
Attention:
12VDC est présent sur les entrées du récepteur du R-8070. Ne PAS court­circuiter les entrées du récepteur. Ne PAS connecter de récepteurs à l'équipement de tests sans un bloc DC.
Issue 1.2, 06 January 2017 Confidential xii
Introduction TetraNode Base Station System
Caution:
All unconnected connectors should remain unconnected unless otherwise stated by Rohill. Unconnected connectors inside a BSS do not require any termination either by design or by function.
This statement is not applicable for connectors meant for external connections such as the ANT (antenna) output of combiners, power supply.
Attention:
Tous les connecteurs non connectés ne devraient PAS être connectés sauf indication contraire de la part de Rohill. Les connecteurs non connectés à l'intérieur d'un BSS ne nécessitent aucune terminaison ni de par leur conception ni de par leur fonction.
Cette déclaration n'est pas applicable pour les connecteurs conçus pour des connexions externes tels que la sortie ANT (antenne) vers les multiplexeurs ou vers une source d'alimentation.
Issue 1.2, 06 January 2017 Confidential xiii
Introduction TetraNode Base Station System
Table of Contents
1 Introduction ....................................................................................16
1.1 Scope ............................................................................................................16
1.2 Base Station System overview ..................................................................16
2 System Options ..............................................................................17
2.1 Number of carriers ......................................................................................17
2.2 Cabinet .........................................................................................................17
2.3 Power supply ...............................................................................................17
2.4 Frequency bands .........................................................................................18
2.5 Transmitter output power ...........................................................................18
2.6 TBS-SYN Timing reference .........................................................................19
2.7 Line Interface(s) ...........................................................................................20
2.8 Environmental ..............................................................................................21
3 Technical description ....................................................................22
3.1 R-8070 transceiver ......................................................................................22
3.1.1 Transceiver User Interface (MMI) ................................................................22
3.1.2 Transceiver Alarms and Warnings ...............................................................27
3.2 Synchronisation TBS-SYN .........................................................................27
3.3 Connections .................................................................................................28
3.3.1 R-8070 connections .....................................................................................28
3.3.2 R-855 TBS-SYN rear panel layout ...............................................................30
4 Installation and configuration .......................................................32
4.1 Equipment room requirements ..................................................................32
4.1.1 Equipment-room earth .................................................................................33
4.2 Installation – floor standing cabinets ........................................................34
4.2.1 Ventilation and cooling .................................................................................34
4.3 Power-supply and Earthing ........................................................................35
4.3.1 Earthing .......................................................................................................36
4.3.2 AC Power cables .........................................................................................36
4.3.3 DC Power cables .........................................................................................37
4.3.4 Power supply ...............................................................................................37
4.4 Network Connections .................................................................................37
4.5 Antenna system ...........................................................................................38
4.5.1 Lightning protection ......................................................................................38
4.5.2 Minimization of exposure to non-ionizing radiation .......................................39
4.6 BSS Configuration ......................................................................................41
5 Maintenance and replacement ......................................................42
Issue 1.2, 06 January 2017 Confidential xiv
Loading...
+ 31 hidden pages