The R&S SMCVB-KV11 is a waveform library that provides waveform files in accordance with the DRM digital standard.
This user manual contains a reference description of the functionality that the waveform library provides. All functions not discussed in this manual are described in the
R&S SMCV100B user manual. The latest version is available at:
www.rohde-schwarz.com/manual/SMCV100B
1.1Key features
The R&SSMCVB-KV11 features:
●
●
Welcome to the R&SSMCVB-KV11 option
Documentation overview
Numerous waveform files in accordance with DRM digital standard
Efficient use with dedicated waveforms
1.2Installation
You can find detailed installation instructions in the supplement document of the
R&S SMCV100B user manual and in the R&S SMCV100B user manual describing
firmware versions FW 4.90.002.xx and later of the R&S SMCV100B.
1.3What's new
Compared to the previous version there are editorial changes only.
1.4Documentation overview
This section provides an overview of the R&S SMCV100B user documentation. Unless
specified otherwise, you find the documents on the R&S SMCV100B product page at:
www.rohde-schwarz.com/manual/smcv100b
1.4.1Getting started manual
Introduces the R&S SMCV100B and describes how to set up and start working with the
product. Includes basic operations, typical measurement examples, and general information, e.g. safety instructions, etc. A printed version is delivered with the instrument.
5User Manual 1179.2760.02 ─ 02
R&S®SMCVB-KV11
1.4.2User manuals and help
Separate manuals for the base unit and the software options are provided for download:
●
●
The contents of the user manuals are available as help in the R&S SMCV100B. The
help offers quick, context-sensitive access to the complete information for the base unit
and the software options.
All user manuals are also available for download or for immediate display on the Internet.
Welcome to the R&S SMCVB-KV11 option
Documentation overview
Base unit manual
Contains the description of all instrument modes and functions. It also provides an
introduction to remote control, a complete description of the remote control commands with programming examples, and information on maintenance, instrument
interfaces and error messages. Includes the contents of the getting started manual.
Software option manual
Contains the description of the specific functions of an option. Basic information on
operating the R&S SMCV100B is not included.
1.4.3Service manual
Describes the performance test for checking compliance with rated specifications, firmware update, troubleshooting, adjustments, installing options and maintenance.
The service manual is available for registered users on the global Rohde & Schwarz
information system (GLORIS):
https://gloris.rohde-schwarz.com
1.4.4Instrument security procedures
Deals with security issues when working with the R&S SMCV100B in secure areas. It
is available for download on the Internet.
1.4.5Printed safety instructions
Provides safety information in many languages. The printed document is delivered with
the product.
1.4.6Data sheets and brochures
The data sheet contains the technical specifications of the R&S SMCV100B. It also
lists the options and their order numbers and optional accessories.
The brochure provides an overview of the instrument and deals with the specific characteristics.
6User Manual 1179.2760.02 ─ 02
R&S®SMCVB-KV11
See www.rohde-schwarz.com/brochure-datasheet/smcv100b
1.4.7Release notes and open source acknowledgment (OSA)
The release notes list new features, improvements and known issues of the current
firmware version, and describe the firmware installation.
The open-source acknowledgment document provides verbatim license texts of the
used open source software.
See www.rohde-schwarz.com/firmware/smcv100b
1.4.8Application notes, application cards, white papers, etc.
These documents deal with special applications or background information on particular topics.
See www.rohde-schwarz.com/application/smcv100b
Welcome to the R&S SMCVB-KV11 option
Documentation overview
7User Manual 1179.2760.02 ─ 02
R&S®SMCVB-KV11
2Available waveform files
This chapter contains the description of the available waveform files.
2.1Artificial folder
The files in this folder are for source-coding test purposes with artificial files for demonstration purposes:
●
●
Naming conventions
Available waveform files
Artificial folder
Artificial signal files containing music (AAC), maybe combined with speech (CELP
or HVXC) or PRBS data for source-coding test purposes with artificial files containing different audio codecs.
Artificial signal files containing speech only (CELP or HVXC) to demonstrate the
different source decoders and text message application.
The main broadcasting parameters are coded in the file name:
●
<transmission mode>
Characters 'A', 'B', 'C' or 'D' depending on the mode.
●
<bandwidth>
Signal bandwidth in kHz as two digits.
●
<modulation of MSC cells>
─ '16' for 16QAM
─ '64' for 64QAM
●
<interleaver length>
─ 's' for short interleaving
─ 'l' for long interleaving
●
<number of code rate>
─ Number out of '0', '1', '2' and '3' for 64QAM
─ Number out of '0' and '1' for 16QAM
●
<audio codec>
Name of the used source coder.
●
<value>dBFS
Scaled to a mean signal level of -<value> dBFS
Example for naming conventions: A04_64s1_aac_ 12dBFS.wv
<interleaver length>
─ 's' for short interleaving
─ 'l' for long interleaving
<number of code rate>
─ Number out of '0', '1', '2' and '3' for 64QAM, HM and HS
─ Number out of '0' and '1' for 16QAM
<special case>
─ 'uep' for unequal error protection (the number of the code rate of the high protected part is one step lower than of the low protected part in each case).
─ '4st' for a signal file using 4 PRBS data streams and services, 'ber1e-?' giving the
bit error rate for all used PRBS data streams or 'async' for asynchronous PRBS
content.
[_wrap]
Capable of wrapping without errors.
<value>dBFS
Scaled to a mean signal level of -<value> dBFS
Example for naming conventions: A04_16l1_uep_wrap_ 10dBFS.wv
Transmission mode: A
Bandwidth: 4 kHz
Modulation of MSC cells: 16QAM
Interleaver length: long
Number of code rate: 1
Special case: uep
wrap: capable of wrapping without errors
Signal level: -10 dB full scale
2.2.1A transmission mode
2.2.1.1A04_16l0_wrap_-10dBFS
Capability of wrapping without errors; scaled to a mean signal level of -10 dBFS.
27User Manual 1179.2760.02 ─ 02
R&S®SMCVB-KV11
Table 2-52: Main broadcasting parameters
Table 2-53: Service parameters
Available waveform files
Test folder
Transmission modeA
Bandwidth4.5 kHz
Constellation SDC4QAM
Constellation MSC16QAM
Code rate MSC part A0.50
Code rate MSC part B0.50
Interleaver depthLong (2.0 s)
ParameterService #0
Service ID1193046
Service typeData
Data stream ID0
Application ID0
Table 2-54: Stream parameters
ParameterStream #0
Data length part A0 bytes/frame
Data length part B313 bytes/frame
2.2.1.2A04_16l1_uep_wrap_-10dBFS
Capability of wrapping without errors; scaled to a mean signal level of -10 dBFS.
Table 2-55: Main broadcasting parameters
Transmission modeA
Bandwidth4.5 kHz
Constellation SDC4QAM
Constellation MSC16QAM
Code rate MSC part A0.50
Code rate MSC part B0.62
Interleaver depthLong (2.0 s)
Table 2-56: Service parameters
ParameterService #0
Service ID1193046
Service typeData
28User Manual 1179.2760.02 ─ 02
R&S®SMCVB-KV11
Table 2-57: Stream parameters
2.2.1.3A04_16l1_wrap_-10dBFS
Capability of wrapping without errors; scaled to a mean signal level of -10 dBFS.
Table 2-58: Main broadcasting parameters
Available waveform files
Test folder
Data stream ID0
Application ID0
ParameterStream #0
Data length part A0 bytes/frame
Data length part B266 bytes/frame
Transmission modeA
Bandwidth4.5 kHz
Constellation SDC4QAM
Constellation MSC16QAM
Code rate MSC part A0.50
Code rate MSC part B0.62
Interleaver depthLong (2.0 s)
Table 2-59: Service parameters
ParameterService #0
Service ID1193046
Service typeData
Data stream ID0
Application ID0
Table 2-60: Stream parameters
ParameterStream #0
Data length part A0 bytes/frame
Data length part B391 bytes/frame
2.2.1.4A04_16s0_wrap_-10dBFS
Capability of wrapping without errors; scaled to a mean signal level of -10 dBFS.
Table 2-61: Main broadcasting parameters
Transmission modeA
Bandwidth4.5 kHz
29User Manual 1179.2760.02 ─ 02
R&S®SMCVB-KV11
Table 2-62: Service parameters
Table 2-63: Stream parameters
Available waveform files
Test folder
Constellation SDC4QAM
Constellation MSC16QAM
Code rate MSC part A0.50
Code rate MSC part B0.50
Interleaver depthShort (0.4 s)
ParameterService #0
Service ID1193046
Service typeData
Data stream ID0
Application ID0
ParameterStream #0
Data length part A0 bytes/frame
Data length part B313 bytes/frame
2.2.1.5A04_16s1_wrap_-10dBFS
Capability of wrapping without errors; scaled to a mean signal level of -10 dBFS.
Table 2-64: Main broadcasting parameters
Transmission modeA
Bandwidth4.5 kHz
Constellation SDC4QAM
Constellation MSC16QAM
Code rate MSC part A0.50
Code rate MSC part B0.62
Interleaver depthShort (0.4 s)
Table 2-65: Service parameters
ParameterService #0
Service ID1193046
Service typeData
Data stream ID0
Application ID0
30User Manual 1179.2760.02 ─ 02
Loading...
+ 243 hidden pages
You need points to download manuals.