Rohde&Schwarz RT-ZD08 User Manual

RT-ZD08 Differential Probe
User Manual
*5800041602*
1333083802
Version 01
User Manual
Test & Measurement
Differential Probe 10 : 1 RT-Z D 0 8
800 MHz bandwidth
high input resistance of 200 kΩ
Specifications
low input capacitance of 1 pF
high dynamic range of ±15 V differential and ±30 V common
universal power supply using battery or USB cable
typical applications: – differential signals like CAN Bus or LVDS – DC-DC converter
General Information
The RT-ZD08 800 MHz Differential probe is best suited for measurements of high-speed differential signals. These signals are commonly used in digital and power applications and especially at serial buses like CAN. The RT-ZD08 can be powered by USB or battery and is compatible with all oscilloscopes with
50 Ω BNC inputs. Oscilloscopes without 50Ω input need a 50 Ω feed through BNC adapter.
The probe has a high input resistance of 200 kΩ combined with 1 pF input capacitance. This secures a low loading of the device under test. The attenuation of the RT-ZD08 is 10 : 1.
Subject to change without notice
Important hints
SPECIFICATIONS
all data valid at 23 °C after 30 minutes warm up
Electrical specications
Bandwidth (-3 dB): 800 MHz, typ. Attenuation Ratio: 10 : 1 Probe Risetime (10%-90%): 437 ps Gain Accuracy: ±2%, typ. Absolute Maximum Rated Input Voltage (each side to ground): ±40 V Maximum Differential Input Voltage (DC+AC Peak): ±15 V Maximum Common Mode Input Voltage ±30 V Input Resistance / Input capacity
each side to ground: 100 kΩ, 2 pF between inputs: 200 kΩ, 1 pF
Output Voltage Swing: ±1.5 V (on 50 Ω scope input) Offset: ±5 mV, typ. CMRR: -60 dB at 60 Hz, typ.
-15 dB at 500 MHz, typ.
Power Requirements: one 9 V battery or USB power adapter (5 V to 9 V, 300 mA)
4
6
5
Approx. Battery Life: 4.5 hours (alkaline battery) Battery/Power Cord: The supplied voltage must be
less than 12 V and greater than
4.5 V or else the probe could be damaged
Mechanical specications
Approximate Weight: 170 g
(not including battery and accessories)
BNC Cable Length: 120 cm Length of Input Leads: 15 cm Dimensiones (LxWxH): 111 x 22 x 14 mm
Environmental Specications
Temperature range operating: 5 °C to +40 °C non-operating: -20 °C to +70 °C Altitude operating: 3,000 m non-operating: 15,300 m Humidity: 25 - 85% indoor use only
1
7
8
Set of R T-ZD0 8 probe consists of: 1 RT-ZD08 800 MHz differential probe 1 piece 2 EZ Hook, red 1 piece
EZHook, black 1 piece 3 Micro IC- Clip, red 1 piece Micro IC- Clip, black 1 piece
4 Signal Pins, single 6 pieces 5 Signal Pins, dual, 16.8 mm 2 pieces 6 Signal Pins, dual, 12.8 mm 2 pieces
2
3
7 Extension le ad, 10 cm, red 1 piece
Extension lead, 10 cm, black 1 piece 8 Extension le ad, 5 cm, red 1 piece Extension lead, 5 cm, black 1 piece
Specications
9 USB Power Cord (2 m) 1 piece 10 9 V Battery 1 piece
Manual 1 piece
10
Subject to change without notice
9
Using the probe and accessories
Important hints
After unpacking please check for mechanical
dam a g e an d loose par t s o a t ing aro u n d in s ide the
instrument. In case of damage please inform the transport company immediately. Do not operate the instrument and protect it against unauthorized operation.
Symbol:
Please consult the manual
Safety instructions
The instrument conforms to the European stan-
dards EN 61010-1 and IEC 61010-1, respectively.
Further Safety Informations
To avoid personal injury and to prevent re or
damage to this product or products connected to it, review and comply with the following safety precautions. Be aware that if you use this probe
as s e m b l y in a mann e r no t spe c i  e d th e prote cti o n
this product provides may be impaired.
– Only qualied personnel should use this
probe assembly. – Use only grounded instruments. – Connect the probe output to the measu-
rement instrument before connecting the
probe to the circuit under test. Disconnect
the probe inputs from the circuit under test
before disconnecting the probe from the
measurement instrument. – Do not apply any electrical potential to the
probe input which exceeds the maximum
ratings of the probe. – Keep away from live circuits. – Avoid open circuitry. Do not touch con-
nections or components when power is
present. – Do not operate with suspected failures.
– Repair only by qualied service personnel.
– Indoor use only. – Do not operate in wet/damp environment.
Keep product surfaces dry and clean. – Do not operate the product in an explosive
atmosphere.
Subject to change without notice
Operating conditions
The permissible operating temperature is +5 °C to +40 °C. During transport and storage the temperature may be –20 °C to +70 °C. In case of condensation after transport it is necessary to dry the probe for at least 2 hrs. prior to operation.
Operate only in clean, dr y rooms.
Warranty and Repair
Our instruments are subject to stri ct qualit y con­trols. Prior to leaving the manufacturing site, each
instrument undergoes a 10-hour burn-in test. This is fo l l o wed by ex te n s i v e func tional qual i t y te s t i n g
to examine all operating modes and to guarantee
comp l i a n c e wi t h th e spec i  e d tec hnic al data. The testing is performed with test equipment that is
calibrated to national standards. The statutory warranty provisions shall be governed by the laws of the country in which the product was pur­chased. In c ase of any complaints, please contact your supplier.
The product may only be opened by authorized
and qualied personnel. Prior to working on the
product or before the product is opened, it must be disconnected from the AC supply network. Otherwise, personnel will be exposed to the risk of an electric shock.
Any adjustments, replacements of par ts, main­tenance and repair may be carried out only by
authorized technical personnel. Only original
parts may be used for replacing par ts relevant to safety (e.g. power switches, power transformers, fuses). A safety test must always be performed after parts relevant to safety have been replaced (visual inspection, PE conductor test, insulation resistance measurement, leakage current mea­surement, functional test). This helps to ensure the continued safety of the product.
Cleaning the Probe
Disconnect the probe and clean it with a soft cloth. Make sure the probe is completely dry before reconnecting it to an instrument. Avoid using abrasive cleaners and chemicals containing benzene or similar solvents.
Handling the Probe
Notes
Handle the probe with care and refer to the safety notices in this manual. Note that the probe cable is a sensitive part of the probe and, therefore, you should be careful not to damage it through ex­cessive bending or pulling. You should also avoid any mechanical shocks to this product in order to guarantee accurate performance and protection.
Using the probe and accessories
To use the pr o b e , r s t slide open the ba t te r y com ­partment on the rear of the probe housing and insert the 9 V battery. You can also use the USB power cord that ships with the probe to supply power instead of the batter y. Simply connect the USB power cord to the probe and an USB port (on a computer or oscilloscope).
Input for USB power cord
Battery Use
Insert one 9V battery in the back of the unit as indicated within the chassis (see picture for the battery location). When battery life has expired, remove the battery. Note the WEEE label on the battery and dispose it properly.
Then connect the BNC output connector to the channel input of the oscilloscope. The os-
cilloscope must have a 50Ω input with ground
reference. In case the oscilloscope does not pro-
vide a 50Ω input please use a 50Ω feed through
termination.
Using the appropriate probe accessories, connect the inputs to the circuit under test.
– To protect against elec trical shock, use only the ac-
cessories supplied with this probe or in the accessory kit.
– This probe is made to carry out differential measure-
ments between two points on the circuit under test. This probe is not made for electrically insulating the circuit under test and the measuring instrument.
Subject to change without notice
Using of accessories
These accessories can be pushed onto the probe as shown below.
Connect EZ Hook to probe
using extension leads (10 cm or 5 cm)
2
7 / 8
Notes
1
3
Connect signal pin dual to probe Connect signal pins single to probe
5 / 6
Connect micro clip to probe
using extension leads (10 cm or 5 cm)
7 / 8
4
1
Subject to change without notice
Notes
Subject to change without notice
© 2016 Rohde & Schwarz GmbH & Co. KG
Mühldorfstr. 15, 81671 München, Germany
Phone: +49 89 41 29 - 0
Fax: +49 89 41 29 12 164
E-mail: info@rohde-schwarz.com
Internet: www.rohde-schwarz.com
Customer Support: www.customersupport.rohde-schwarz.com
Service: www.service.rohde-schwarz.com
Subject to change – Data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
Throughout this manual, products from Rohde & Schwarz are indicated without the R&S® symbol,
e.g. R&S®RT-ZD08 is indicated as RT-ZD08.
1333.0838.02 │Version 01 │RT-ZD08
Loading...