Rohde&Schwarz R&S®ZNC/ZND Getting Started Getting started

R&S®ZND Vector Network Analyzers Getting Started
1316240702 Version 62
This manual describes the R&S®ZND (2 ports, 9 kHz to 4.5 GHz, unidirectional, N connectors), order no.
1328.5170K92 and its options. Hardware Options
R&S®ZND-B7 "High Output Power", order no. 1338.1578.02
R&S®ZND-B10 "GPIB Interface", order no. 1328.5358.02
R&S®ZN-B14 "Handler I/O", order no. 1316.2459.05
Software Options
R&S®ZND-K1 "Frequency range extension to 8.5 GHz for unidirectional instrument", order no.
1328.5306.02 (not compatible with R&S®ZND-K5 and R&S®ZND-K8)
R&S®ZND-K2 "Time Domain (TDR)", order no. 1328.5393.02
R&S®ZND-K5 "Bidirectional measurements 9 kHz to 4.5 GHz", order no. 1328.5312.02 (not compatible with R&S®ZND-K1 and R&S®ZND-K6)
R&S®ZND-K6 "Bidirectional measurements 9 kHz to 8.5 GHz", order no. 1328.5329.02 (requires R&S®ZND-K1; not compatible with R&S®ZND-K5 and R&S®ZND-K8)
R&S®ZND-K8 "Frequency range extension to 8.5 GHz for bidirectional instrument", order no.
1328.5412.02 (requires R&S®ZND-K5; not compatible with R&S®ZND-K1 and R&S®ZND-K6)
R&S®ZND-K7 "Extended Power Range", order no. 1328.5335.02
R&S®ZND-K19 "1 mHz Frequency Resolution", order no. 1326.8089.02
© 2022 Rohde & Schwarz GmbH & Co. KG
Muehldorfstr. 15, 81671 Muenchen, Germany
Phone: +49 89 41 29 - 0
Email: info@rohde-schwarz.com
Internet: www.rohde-schwarz.com
Subject to change – data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
1316.2407.02 | Version 62 | R&S®ZND
Throughout this manual, R&S® is abbreviated as R&S.
R&S®ZND

Contents

Contents
1 Safety and regulatory information........................................................7
1.1 Safety instructions........................................................................................................7
1.2 Warning messages in the documentation.................................................................. 9
1.3 Korea certification class A......................................................................................... 10
2 Documentation overview.....................................................................11
2.1 Getting started manual............................................................................................... 11
2.2 User manual and help................................................................................................. 11
2.3 Service manual............................................................................................................ 11
2.4 Instrument security procedures................................................................................ 12
2.5 Printed safety instructions.........................................................................................12
2.6 Data sheets and brochures........................................................................................ 12
2.7 Release notes and open source acknowledgment (OSA).......................................12
2.8 Application notes, application cards, white papers, etc......................................... 12
3 Preparing for use................................................................................. 13
3.1 Lifting and carrying.....................................................................................................13
3.2 Unpacking and checking............................................................................................13
3.3 Choosing the operating site.......................................................................................13
3.4 Setting up the product................................................................................................14
3.4.1 Placing the product on a bench top...............................................................................14
3.4.2 Mounting the product in a rack......................................................................................15
3.5 Considerations for test setup.................................................................................... 16
3.6 Connecting the analyzer to the AC supply............................................................... 17
3.7 Switching the instrument on and off.........................................................................17
3.8 Standby and ready state.............................................................................................18
3.9 Windows operating system........................................................................................18
3.10 Minimizing the VNA application.................................................................................20
3.11 Connecting external accessories..............................................................................20
3.11.1 Connecting a monitor.................................................................................................... 21
3.11.2 Connecting a keyboard................................................................................................. 21
3.11.3 Connecting a mouse..................................................................................................... 21
3.11.4 Connecting a printer......................................................................................................22
3Getting Started 1316.2407.02 ─ 62
R&S®ZND
Contents
3.11.5 Connecting a LAN cable............................................................................................... 23
4 Instrument tour.....................................................................................24
4.1 Front panel...................................................................................................................24
4.1.1 Touchscreen.................................................................................................................. 24
4.1.2 Function keys................................................................................................................ 25
4.1.3 Data entry keys............................................................................................................. 26
4.1.4 Rotary knob...................................................................................................................27
4.1.5 Navigation keys.............................................................................................................27
4.1.6 Standby key.................................................................................................................. 28
4.1.7 Front panel connectors................................................................................................. 28
4.2 Rear panel....................................................................................................................29
5 Operating the instrument.................................................................... 31
5.1 Manual operation........................................................................................................ 31
5.2 Control elements of the application window............................................................36
5.2.1 Title bar......................................................................................................................... 37
5.2.2 Toolbar.......................................................................................................................... 37
5.2.3 Softtools........................................................................................................................ 38
5.2.4 Menu bar....................................................................................................................... 39
5.2.5 Menu structure.............................................................................................................. 40
5.2.6 Hardkey panel............................................................................................................... 41
5.2.7 Status bar......................................................................................................................41
5.3 Working with dialogs.................................................................................................. 42
5.4 Handling diagrams, traces, and markers..................................................................43
5.4.1 Adding new traces and diagrams..................................................................................43
5.4.2 Adding new markers..................................................................................................... 45
5.4.3 Deleting display elements............................................................................................. 46
5.4.4 Using drag and drop......................................................................................................46
5.5 Entering data............................................................................................................... 47
5.5.1 Using front panel keys...................................................................................................47
5.5.2 Using the numeric editor............................................................................................... 48
5.5.3 Using the analyzer's on-screen keyboard..................................................................... 49
5.5.4
Using the Windows® on-screen keyboard.....................................................................49
5.6 Scaling diagrams........................................................................................................ 50
4Getting Started 1316.2407.02 ─ 62
R&S®ZND
Contents
5.6.1 Using the graphical zoom..............................................................................................50
5.6.2 Setting the sweep range............................................................................................... 52
5.6.3 Reference value and position........................................................................................53
5.6.4 Auto scale..................................................................................................................... 53
5.6.5 Circular diagrams.......................................................................................................... 54
5.6.6 Set by marker................................................................................................................54
5.6.7 Enlarging a diagram...................................................................................................... 55
6 Performing measurements..................................................................56
6.1 Transmission S-parameter measurement.................................................................56
6.1.1 Connecting the instrument for transmission measurements......................................... 56
6.1.2 Selecting the sweep range and other parameters........................................................ 57
6.1.3 Calibrating the instrument............................................................................................. 58
6.1.4 Evaluating data............................................................................................................. 61
6.1.5 Saving and printing data............................................................................................... 62
6.2 Reflection S-parameter measurement...................................................................... 63
7 Administrative tasks............................................................................65
7.1 Firmware installation.................................................................................................. 65
7.2 Remote operation in a LAN........................................................................................ 66
7.2.1 Assigning an IP address............................................................................................... 66
7.2.2 Using computer names................................................................................................. 68
7.2.3 Remote Desktop connection......................................................................................... 68
7.2.4
Windows® firewall settings............................................................................................ 69
8 Contacting customer support.............................................................70
Index......................................................................................................71
5Getting Started 1316.2407.02 ─ 62
R&S®ZND
Contents
6Getting Started 1316.2407.02 ─ 62
R&S®ZND
Safety and regulatory information
Safety instructions

1 Safety and regulatory information

The product documentation helps you use the product safely and efficiently. Follow the instructions provided here and in the following chapters.
Intended use
The product is intended for the development, production and verification of electronic components and devices in industrial, administrative, and laboratory environments. Use the product only for its designated purpose. Observe the operating conditions and performance limits stated in the data sheet.
Where do I find safety information?
Safety information is part of the product documentation. It warns you of potential dan­gers and gives instructions on how to prevent personal injury or damage caused by dangerous situations. Safety information is provided as follows:
In Chapter 1.1, "Safety instructions", on page 7. The same information is provi­ded in many languages as printed "Safety Instructions". The printed "Safety Instructions" are delivered with the product.
Throughout the documentation, safety instructions are provided when you need to take care during setup or operation.

1.1 Safety instructions

Products from the Rohde & Schwarz group of companies are manufactured according to the highest technical standards. To use the products safely, follow the instructions provided here and in the product documentation. Keep the product documentation nearby and offer it to other users.
Use the product only for its intended use and within its performance limits. Intended use and limits are described in the product documentation such as the data sheet, manuals and the printed "Safety Instructions". If you are unsure about the appropriate use, contact Rohde & Schwarz customer service.
Using the product requires specialists or specially trained personnel. These users also need sound knowledge of at least one of the languages in which the user interfaces and the product documentation are available.
Never open the casing of the product. Only service personnel authorized by Rohde & Schwarz are allowed to repair the product. If any part of the product is dam­aged or broken, stop using the product. Contact Rohde & Schwarz customer service at
http://www.customersupport.rohde-schwarz.com.
Lifting and carrying the product
The maximum weight of the product is provided in the data sheet. To move the product safely, you can use lifting or transporting equipment such as lift trucks and forklifts. Fol­low the instructions provided by the equipment manufacturer.
7Getting Started 1316.2407.02 ─ 62
R&S®ZND
Safety and regulatory information
Safety instructions
Choosing the operating site
Only use the product indoors. The product casing is not waterproof. Water that enters can electrically connect the casing with live parts, which can lead to electric shock, serious personal injury or death if you touch the casing. If Rohde & Schwarz provides accessories designed for your product, e.g. a carrying bag, you can use the product outdoors.
Unless otherwise specified, you can operate the product up to an altitude of 2000 m above sea level. The product is suitable for pollution degree 2 environments where nonconductive contamination can occur. For more information on environmental condi­tions such as ambient temperature and humidity, see the data sheet.
Setting up the product
Always place the product on a stable, flat and level surface with the bottom of the prod­uct facing down. If the product is designed for different positions, secure the product so that it cannot fall over.
If the product has foldable feet, always fold the feet completely in or out to ensure sta­bility. The feet can collapse if they are not folded out completely or if the product is moved without lifting it. The foldable feet are designed to carry the weight of the prod­uct, but not an extra load.
If stacking is possible, keep in mind that a stack of products can fall over and cause injury.
If you mount products in a rack, ensure that the rack has sufficient load capacity and stability. Observe the specifications of the rack manufacturer. Always install the prod­ucts from the bottom shelf to the top shelf so that the rack stands securely. Secure the product so that it cannot fall off the rack.
Connecting to power
The product is an overvoltage category II product. Connect the product to a fixed installation used to supply energy-consuming equipment such as household applian­ces and similar loads. Keep in mind that electrically powered products have risks, such as electric shock, fire, personal injury or even death.
Take the following measures for your safety:
Before switching on the product, ensure that the voltage and frequency indicated on the product match the available power source. If the power adapter does not adjust automatically, set the correct value and check the rating of the fuse.
Only use the power cable delivered with the product. It complies with country-spe­cific safety requirements. Only insert the plug into an outlet with protective conduc­tor terminal.
Only use intact cables and route them carefully so that they cannot be damaged. Check the power cables regularly to ensure that they are undamaged. Also ensure that nobody can trip over loose cables.
If the product needs an external power supply, use the power supply that is deliv­ered with the product or that is recommended in the product documentation or a power supply that conforms to the country-specific regulations.
8Getting Started 1316.2407.02 ─ 62
R&S®ZND
Safety and regulatory information
Warning messages in the documentation
Only connect the product to a power source with a fuse protection of maximum 20 A.
Ensure that you can disconnect the product from the power source at any time. Pull the power plug to disconnect the product. The power plug must be easily accessible. If the product is integrated into a system that does not meet these requirements, provide an easily accessible circuit breaker at the system level.
Cleaning the product
Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that the casing is not waterproof. Do not use liquid cleaning agents.
Meaning of safety labels
Safety labels on the product warn against potential hazards.
Potential hazard
Read the product documentation to avoid personal injury or product damage.
Electrical hazard
Indicates live parts. Risk of electric shock, fire, personal injury or even death.
Hot surface
Do not touch. Risk of skin burns. Risk of fire.
Protective conductor terminal
Connect this terminal to a grounded external conductor or to protective ground. This connec­tion protects you against electric shock if an electric problem occurs.

1.2 Warning messages in the documentation

A warning message points out a risk or danger that you need to be aware of. The sig­nal word indicates the severity of the safety hazard and how likely it will occur if you do not follow the safety precautions.
WARNING
Potentially hazardous situation. Could result in death or serious injury if not avoided.
NOTICE
Potential risks of damage. Could result in damage to the supported product or to other property.
9Getting Started 1316.2407.02 ─ 62
R&S®ZND
Safety and regulatory information
Korea certification class A

1.3 Korea certification class A

이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.
10Getting Started 1316.2407.02 ─ 62
R&S®ZND
Documentation overview
Service manual

2 Documentation overview

This section provides an overview of the R&S ZND user documentation. Unless speci­fied otherwise, you find the documents on the R&S ZND product page at:
https://www.rohde-schwarz.com/manual/ZND

2.1 Getting started manual

Introduces the R&S ZND and describes how to set up and start working with the prod­uct. Includes basic operations, typical measurement examples, and general informa­tion, e.g. safety instructions, etc.
A printed version is delivered with the instrument. A PDF version is available for down­load on the Internet.

2.2 User manual and help

The user manual contains the description of all instrument modes and functions. It also provides an introduction to remote control, a complete description of the remote control commands with programming examples, and information on maintenance, instrument interfaces and error messages. Includes the contents of the getting started manual.
The contents of the user manual are available as help in the R&S ZND. The help offers quick, context-sensitive access to the complete information for the instrument and its firmware.
The user manual is also available for download or for immediate display on the Inter­net.

2.3 Service manual

Describes the performance test for checking the rated specifications, module replace­ment and repair, firmware update, troubleshooting and fault elimination, and contains mechanical drawings and spare part lists.
The service manual is available for registered users on the global Rohde & Schwarz information system (GLORIS):
https://gloris.rohde-schwarz.com
11Getting Started 1316.2407.02 ─ 62
R&S®ZND
Documentation overview
Application notes, application cards, white papers, etc.

2.4 Instrument security procedures

Deals with security issues when working with the R&S ZND in secure areas. It is avail­able for download on the Internet.

2.5 Printed safety instructions

Provides safety information in many languages. The printed document is delivered with the product.

2.6 Data sheets and brochures

The data sheet contains the technical specifications of the R&S ZND. It also lists the firmware applications and their order numbers, and optional accessories.
The brochure provides an overview of the instrument and deals with the specific char­acteristics.
See https://www.rohde-schwarz.com/brochure-datasheet/ZND

2.7 Release notes and open source acknowledgment (OSA)

The release notes list new features, improvements and known issues of the current firmware version, and describe the firmware installation.
The open-source acknowledgment document provides verbatim license texts of the used open source software.

2.8 Application notes, application cards, white papers, etc.

These documents deal with special applications or background information on particu­lar topics.
See https://www.rohde-schwarz.com/brochure-datasheet/ZND
12Getting Started 1316.2407.02 ─ 62
R&S®ZND
Preparing for use
Choosing the operating site

3 Preparing for use

Here, you can find basic information about setting up the product for the first time.

3.1 Lifting and carrying

The carrying handles are designed to lift or carry the instrument. Do not apply exces­sive external force to the handles.
See "Lifting and carrying the product" on page 7.

3.2 Unpacking and checking

1. Unpack the R&S ZND carefully.
2. Retain the original packing material. Use it when transporting or shipping the
R&S ZND later.
3. Using the delivery notes, check the equipment for completeness.
4. Check the equipment for damage.
If the delivery is incomplete or equipment is damaged, contact Rohde & Schwarz.

3.3 Choosing the operating site

Specific operating conditions ensure proper operation and avoid damage to the prod­uct and connected devices. For information on environmental conditions such as ambi­ent temperature and humidity, see the data sheet.
See also "Choosing the operating site" on page 8.
Electromagnetic compatibility classes
The electromagnetic compatibility (EMC) class indicates where you can operate the product. The EMC class of the product is given in the data sheet.
Class B equipment is suitable for use in:
Residential environments
Environments that are directly connected to a low-voltage supply network that
supplies residential buildings
Class A equipment is intended for use in industrial environments. It can cause radio disturbances in residential environments due to possible conducted and radi­ated disturbances. It is therefore not suitable for class B environments.
13Getting Started 1316.2407.02 ─ 62
R&S®ZND
If class A equipment causes radio disturbances, take appropriate measures to eliminate them.

3.4 Setting up the product

See also:
"Setting up the product" on page 8
"Intended use" on page 7

3.4.1 Placing the product on a bench top

To place the product on a bench top
1. Place the product on a stable, flat and level surface. Ensure that the surface can
support the weight of the product. For information on the weight, see the data sheet.
Preparing for use
Setting up the product
CAUTION! Foldable feet can collapse. See "Setting up the product" on page 8.
2.
Always fold the feet completely in or out. With folded-out feet, do not place any­thing on top or underneath the product.
WARNING! A stack of products can fall over and cause injury. Never stack more
3.
than three products on top of each other. Instead, mount them in a rack.
Stack as follows:
If the products have foldable feet, fold them in completely.
It is best if all products have the same dimensions (width and length). If the products have different dimensions, stack according to size and place the smallest product on top.
Do not exceed the permissible total load placed on the product at the bottom of the stack: – 50 kg when stacking products of identical dimensions (left figure). – 25 kg when stacking smaller products on top (middle figure).
14Getting Started 1316.2407.02 ─ 62
R&S®ZND
Left = Stacked correctly, same dimensions Middle = Stacked correctly, different dimensions Right = Stacked incorrectly, too many products
NOTICE! Overheating can damage the product.
4.
Prevent overheating as follows:
Keep a minimum distance of 10 cm between the fan openings of the product and any object in the vicinity.
Do not place the product next to heat-generating equipment such as radiators or other products.

3.4.2 Mounting the product in a rack

To prepare the rack
1. Observe the requirements and instructions in "Setting up the product" on page 8.
Preparing for use
Setting up the product
NOTICE! Insufficient airflow can cause overheating and damage the product.
2.
Design and implement an efficient ventilation concept for the rack.
To mount the R&S ZND in a rack
1. Use an adapter kit to prepare the R&S ZND for rack mounting.
a) Order the rack adapter kit R&S ZZA-KN5 (order number 1175.3040.00). b) Mount the adapter kit. Follow the assembly instructions provided with the
adapter kit.
2. Lift the R&S ZND to shelf height.
3. Grab the handles and push the R&S ZND onto the shelf until the rack brackets fit
closely to the rack.
4. Tighten all screws in the rack brackets with a tightening torque of 1.2 Nm to secure the R&S ZND in the rack.
To unmount the R&S ZND from a rack
1. Loosen the screws at the rack brackets.
2. Remove the R&S ZND from the rack.
3. If placing the R&S ZND on a bench top again, unmount the adapter kit from the R&S ZND. Follow the instructions provided with the adapter kit.
15Getting Started 1316.2407.02 ─ 62
R&S®ZND

3.5 Considerations for test setup

Cable selection and electromagnetic interference (EMI)
Electromagnetic interference (EMI) can affect the measurement results.
To suppress electromagnetic radiation during operation:
Use high-quality shielded cables, for example, double-shielded RF and LAN cables.
Always terminate open cable ends.
Ensure that connected external devices comply with EMC regulations.
Regarding cable length and quality, the following requirements have to be met:
Table 3-1: Cable Requirements
Cable Type (Connector) Requirement
RF cables (PORT 1, ..., PORT N) Double shielded
Preparing for use
Considerations for test setup
BNC cables (various) Double shielded
DB-25 (USER PORT) Double shielded
GPIB Standard cable
Handler I/O Standard cable
DVI-D (Monitor) 2 ferrite cores
LAN At least CAT6, S/FTP
USB Standard cables, length ≤ 3m
Signal input and output levels
Information on signal levels is provided in the data sheet. Keep the signal levels within the specified ranges to avoid damage to the product and connected devices.
Preventing electrostatic discharge (ESD)
Electrostatic discharge is most likely to occur when you connect or disconnect a DUT.
NOTICE! Electrostatic discharge can damage the electronic components of the
product and the device under test (DUT).
Ground yourself to prevent electrostatic discharge damage:
a) Use a wrist strap and cord to connect yourself to ground. b) Use a conductive floor mat and heel strap combination.
During operation, if the firmware observes a serious unexpected disturbance (e.g. due to ESD), it resets all hardware components to ensure proper instrument functioning. It then restores the user settings to the state before the disturbance and indicates the foregone hardware reset by an "Hardware communication problem [...]" information popup.
16Getting Started 1316.2407.02 ─ 62
R&S®ZND
Preparing for use
Switching the instrument on and off

3.6 Connecting the analyzer to the AC supply

For safety information, see "Connecting to power" on page 8.
The network analyzer is automatically adapted to the AC supply voltage, which must be in the range of 100 V to 240 V at 50 Hz to 60 Hz. The AC power connector is loca­ted in the upper part of the rear panel (see Chapter 4.2, "Rear panel", on page 29).
1. Plug the AC power cable into the AC power connector on the rear panel of the product. Only use the AC power cable delivered with the product.
2. Plug the AC power cable into a power outlet with ground contact.
The required ratings are listed next to the AC power connector and in the data sheet.
3.
If necessary, also ground the product using the grounding terminal
The maximum power consumption and the typical power consumption of the individual analyzer models are listed in the data sheet.

3.7 Switching the instrument on and off

To switch on the R&S ZND
1. Switch the AC power switch to position I (On). The AC power switch is located in the upper part of the rear panel, together with the mains connector; see Chapter 4.2, "Rear panel", on page 29.
After power-on, the analyzer automatically goes to standby or ready state, depend­ing on the state of the standby toggle key at the front panel when the instrument was switched off last time.
2. If necessary, press the standby toggle key on the front panel to switch the instru­ment to ready state.
See Chapter 3.8, "Standby and ready state", on page 18
.
The instrument automatically performs a system check, boots the Windows® oper­ating system and then starts the vector network analyzer (VNA) application. If it was terminated regularly, the VNA application restores all recall sets and instru­ment settings of the previous analyzer session.
To shut down the instrument
1. Press the standby toggle key.
Pressing the standby toggle key causes the instrument to save all loaded recall sets, to close the VNA application, to shut down Windows®, and to go to standby state (see Chapter 3.8, "Standby and ready state", on page 18).
17Getting Started 1316.2407.02 ─ 62
R&S®ZND
Of course, you can also perform these steps manually, like in any Windows ses­sion.
2. If desired, set the AC power switch to position O (Off).
To disconnect from power
The R&S ZND is in standby state.
NOTICE! Risk of data loss. If you disconnect the product from power when it is in
1. the ready state, you can lose settings and data. Shut it down first.
Set the switch on the power supply to position [0].
The LED of the standby toggle key key is switched off.
2. Disconnect the R&S ZND from the power source.

3.8 Standby and ready state

Preparing for use
Windows operating system
The standby toggle key is located in the bottom-left corner of the front panel.
In standby state, the right, amber LED is on. The standby power only supplies the power switch circuits. In this state, it is safe to switch the AC power off and disconnect the instrument from the power supply.
In ready state, the left, green LED is on and all modules are power-supplied. When switched to ready state, the analyzer initiates its startup procedure.
Observe the instructions for startup and shutdown in Chapter 3.7, "Switching the instru-
ment on and off", on page 17.

3.9 Windows operating system

The analyzer is equipped with a Windows® operating system which has been config­ured according to the instrument's features and needs. Changes in the system configu­ration can be necessary to:
Establish a LAN connection
Customize the properties of the external accessories connected to the analyzer
Call up additional software tools
Modifications of the operating system
The operating system is adapted to the network analyzer. To avoid impairment of instrument functions, only change the settings described in this manual. Existing soft­ware must be modified only with update software released by Rohde & Schwarz. Like­wise, only programs authorized by Rohde & Schwarz for use on the instrument must be executed.
18Getting Started 1316.2407.02 ─ 62
R&S®ZND
Preparing for use
Windows operating system
All necessary settings can be accessed from the Windows "Start" menu, in particular from the "Control Panel". To open the "Start" menu, press the Windows key in the tool­bar or on an external keyboard.
User accounts and password protection
The analyzer uses a user name and password as credentials for remote access. Two user accounts with different levels of access are available on the instrument:
"instrument" is the default account with standard rights to change system settings. Use this account for normal operation of the analyzer.
"Admin" is the account for administering the operating system. This account is required, for instance, if you wish to install programs on the analyzer. [For instruments running Windows 7, this account is named "Administrator".]
In the factory configuration, "894129" is preset as a password for both users. To protect the analyzer from unauthorized access, it is recommended to change the preset pass­words.
To switch from one user account to another, log off from Windows and then log on again. The "switch user" functionality is disabled on the R&S ZND.
Service packs and updates
Microsoft regularly creates security updates and other patches to protect Windows­based operating systems. They are released through the Microsoft Update website and associated update server. Update instruments using Windows regularly, especially instruments that connect to a network.
Firewall settings
A firewall protects an instrument by preventing unauthorized users from gaining access to it through a network. Rohde & Schwarz highly recommends using the firewall on your instrument. Rohde & Schwarz instruments are shipped with the Windows firewall enabled. All ports and connections for remote control are enabled.
Note that changing firewall settings requires administrator rights.
Virus protection
Take appropriate steps to protect your instruments from infection. Use strong firewall settings and scan any removable storage device used with a Rohde & Schwarz instru­ment regularly. It is also recommended that you install anti-virus software on the instru­ment. Rohde & Schwarz does NOT recommend running anti-virus software in the background ("on-access" mode) on Windows-based instruments, due to potentially degrading instrument performance. However, Rohde & Schwarz does recommend run­ning it during non-critical hours.
For details and recommendations, see the following Rohde & Schwarz white paper:
1EF96: Malware Protection Windows 10
Windows 7: 1DC01: Malware Protection Windows 7
19Getting Started 1316.2407.02 ─ 62
R&S®ZND

3.10 Minimizing the VNA application

Preparing for use
Connecting external accessories
With a minimized VNA application, you can access your analyzer's Windows® desktop or run other applications.
To exit the default full-screen mode of the VNA application, deselect SYSTEM – [DIS­PLAY] > "View Bar" > "Title Bar Task Bar". Then use the standard Windows® titlebar functions to minimize/maximize/close the application window.
To start the VNA application with a minimized window
1. Right-click the Vector Network Analyzer shortcut icon on the desktop and open the "Properties" dialog.
2. In the "Shortcut" tab, select "Run: Minimized".
A software update restores the original shortcut properties.

3.11 Connecting external accessories

The analyzer's standard PC interfaces (Monitor, USB, LAN) can be used to connect various accessories:
An external monitor expands/displays the Windows® desktop, which is, by default, covered by the vector network analyzer (VNA) (VNA) application window in full­screen mode.
External keyboard and mouse simplify local control, in particular manual (GUI) operation of the VNA application.
A printer can be used to create hard copies of the measurement diagrams and traces from within the VNA application.
20Getting Started 1316.2407.02 ─ 62
R&S®ZND

3.11.1 Connecting a monitor

Preparing for use
Connecting external accessories
A LAN connection can be established to access the analyzer's mass storage or control the analyzer from an external PC.
External monitor, keyboard and mouse are not required for local operation. A R&S ZND can be fully controlled by tapping the touchscreen and front panel keys.
A standard monitor can be connected to the DVI-D connector on the rear panel of the R&S ZND. No extra configuration is required.
Safety aspects
The monitor must be connected while the instrument is switched off (or in standby mode). Otherwise correct operation cannot be guaranteed.
Select SYSTEM > [DISPLAY] > "View Bar" > "Hard Key Panel On" from the menu bar of the VNA application window to add the (virtual) "Hard Key Panel" to the application window.

3.11.2 Connecting a keyboard

A keyboard can be connected to any of the USB connectors. After being auto-detected by the operating system, it can safely be disconnected and reconnected even during measurements.
Keyboard configuration
The default input language is English – US. Select "Settings" > "Time & language" > "Region & language" from the Windows® Start menu to manage languages and key­boards.
Windows 7: select "Control Panel" > "Clock, Language, and Region" > "Region and Language" > "Keyboards and Languages" from the Windows® Start menu to configure the keyboard properties.
To access Windows®, use the button in the toolbar of the application window.

3.11.3 Connecting a mouse

A USB mouse can be connected to any of the USB connectors. After being auto-detec­ted by the operating system, it can safely be disconnected and reconnected even dur­ing measurements.
21Getting Started 1316.2407.02 ─ 62
R&S®ZND
Preparing for use
Connecting external accessories
Mouse configuration
Select "Settings" > "Devices" > "Mouse & touchpad" from the Windows® "Start" menu to configure the mouse properties.
Windows 7: select "Control Panel" > "Hardware and Sound" > "Devices and Printers" > "Mouse" from the Windows® "Start" menu to configure the mouse properties.
To access Windows®, use the

3.11.4 Connecting a printer

A printer can be connected to any of the USB connectors. After successful installation, it can safely be disconnected and reconnected even during measurements.
Before printing (SYSTEM – [PRINT]), the analyzer checks whether a printer is connec­ted and turned on and whether the appropriate printer driver is installed.
Printer driver installation
If necessary, the printer driver installation is initiated using the operating system's "Add Printer Wizard". The wizard is self-explanatory. A printer driver must be installed only once.
A great variety of printer drivers is available on the analyzer. To obtain the complete list, select "Settings" > "Devices" > "Printers & scanners" from the Windows® "Start" menu.
Windows 7: select "Control Panel" > "Hardware and Sound" > "Devices and Printers" from the Windows® "Start" menu.
button in the toolbar of the application window.
To access Windows®, use the
You can load updated and improved driver versions or new drivers from an installation disk, USB memory stick or another external storage medium. Alternatively, if the ana­lyzer is integrated in a network, you can install driver data stored in a network directory. In either case, use the "Add Printer" wizard to complete the installation.
Printer configuration
Use the "Printer Setup" dialog of the firmware (SYSTEM – [PRINT] > "Print...") or the Windows® printer management to configure the printer properties and printing prefer­ences.
button in the toolbar of the application window.
22Getting Started 1316.2407.02 ─ 62
Loading...
+ 50 hidden pages