Rohde&Schwarz R&S®ZNB/ZNBT Getting Started Getting started

R&S®ZNB/ZNBT Vector Network Analyzers Getting Started
1316006202 Version 62
This document applies to the following vector network analyzer models and their options:
R&S® ZNB4, 9 kHz to 4.5 GHz, 2 test ports, order no. 1311.6010K22
R&S® ZNB4, 9 kHz to 4.5 GHz, 2 test ports, order no. 1334.3330K22
R&S® ZNB4, 9 kHz to 4.5 GHz, 4 test ports, order no. 1311.6010K24
R&S® ZNB4, 9 kHz to 4.5 GHz, 4 test ports, order no. 1334.3330K24
R&S® ZNB8, 9 kHz to 8.5 GHz, 2 test ports, order no. 1311.6010K42
R&S® ZNB8, 9 kHz to 8.5 GHz, 2 test ports, order no. 1334.3330K42
R&S® ZNB8, 9 kHz to 8.5 GHz, 4 test ports, order no. 1311.6010K44
R&S® ZNB8, 9 kHz to 8.5 GHz, 4 test ports, order no. 1334.3330K44
R&S® ZNB20, 100 kHz to 20 GHz, 2 test ports, order no. 1311.6010K62
R&S® ZNB20, 100 kHz to 20 GHz, 2 test ports, order no. 1334.3330K62
R&S® ZNB20, 100 kHz to 20 GHz, 4 test ports, order no. 1311.6010K64
R&S® ZNB20, 100 kHz to 20 GHz, 4 test ports, order no. 1334.3330K64
R&S® ZNB26, 100 kHz to 26.5 GHz, 2 test ports, order no. 1334.3330K63
R&S® ZNB26, 100 kHz to 26.5 GHz, 4 test ports, order no. 1334.3330K65
R&S® ZNB40, 10 MHz to 40 GHz, 2 test ports, order no. 1311.6010K72
R&S® ZNB40, 100 kHz to 40 GHz, 2 test ports, order no. 1311.6010K82
R&S® ZNB40, 100 kHz to 40 GHz, 4 test ports, order no. 1311.6010K84
R&S® ZNB43, 100 kHz to 43.5 GHz, 2 test ports 2.92 mm, order no. 1334.3330K92
R&S® ZNB43, 100 kHz to 43.5 GHz, 2 test ports 2.4 mm, order no. 1334.3330K93
R&S® ZNB43, 100 kHz to 43.5 GHz, 4 test ports 2.92 mm, order no. 1334.3330K94
R&S® ZNB43, 100 kHz to 43.5 GHz, 4 test ports 2.4 mm, order no. 1334.3330K95
R&S® ZNBT8, 9 kHz to 8.5 GHz, 4 test ports (up to 24 ports optional), order no. 1318.7006K24
R&S® ZNBT20, 100 kHz to 20 GHz, 8 test ports (up to 24 ports optional), order no. 1332.9002K24
R&S® ZNBT26, 100 kHz to 26.5 GHz, 8 test ports (up to 24 ports optional), order no. 1332.9002K34
R&S® ZNBT40, 100 kHz to 40 GHz, 8 test ports (up to 24 ports optional), order no. 1332.9002K44
© 2022 Rohde & Schwarz GmbH & Co. KG
Muehldorfstr. 15, 81671 Muenchen, Germany
Phone: +49 89 41 29 - 0
Email: info@rohde-schwarz.com
Internet: www.rohde-schwarz.com
Subject to change – data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
1316.0062.02 | Version 62 | R&S®ZNB/ZNBT
Throughout this manual, R&S® is abbreviated as R&S.
R&S®ZNB/ZNBT
1 Safety and regulatory information........................................................7
1.1 Safety instructions........................................................................................................7
1.2 Warning messages in the documentation................................................................ 10
1.3 Korea certification class A......................................................................................... 10
2 Documentation overview.....................................................................11
2.1 Getting started manual............................................................................................... 11
2.2 User manual and help................................................................................................. 11
2.3 Service manual............................................................................................................ 11
2.4 Instrument security procedures................................................................................ 12
2.5 Printed safety instructions.........................................................................................12

Contents

Contents
2.6 Data sheets and brochures........................................................................................ 12
2.7 Release notes and open source acknowledgment (OSA).......................................12
2.8 Application notes, application cards, white papers, etc......................................... 12
3 Preparing for use................................................................................. 13
3.1 Lifting and carrying.....................................................................................................13
3.2 Unpacking and checking............................................................................................13
3.3 Choosing the operating site.......................................................................................13
3.4 Setting up the product................................................................................................14
3.4.1 Placing the product on a bench top...............................................................................14
3.4.2 Mounting the product in a rack......................................................................................15
3.5 Considerations for test setup.................................................................................... 15
3.6 Connecting the analyzer to the AC supply............................................................... 16
3.7 Switching the instrument on and off.........................................................................17
3.8 Standby and ready state.............................................................................................18
3.9 Windows operating system........................................................................................19
3.10 Minimizing the VNA application.................................................................................20
3.11 Connecting external accessories..............................................................................21
3.11.1 Connecting a monitor.................................................................................................... 21
3.11.2 Connecting a keyboard................................................................................................. 22
3.11.3 Connecting a mouse..................................................................................................... 23
3.11.4 Connecting a printer......................................................................................................23
3Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
3.11.5 Connecting a LAN cable............................................................................................... 24
3.11.6 Connecting a USB cable for remote control..................................................................24
3.12 Remote operation in a LAN........................................................................................ 24
3.12.1 Assigning an IP address............................................................................................... 25
3.12.2 Using computer names................................................................................................. 26
3.12.3 Remote Desktop connection......................................................................................... 27
Contents
3.12.4
Windows® firewall settings............................................................................................ 28
4 Instrument tour.....................................................................................29
4.1 Front panel R&S ZNB..................................................................................................29
4.1.1 Touchscreen.................................................................................................................. 30
4.1.2 Function keys................................................................................................................ 30
4.1.3 Data entry keys............................................................................................................. 31
4.1.4 Rotary knob...................................................................................................................32
4.1.5 Navigation keys.............................................................................................................32
4.1.6 Standby key.................................................................................................................. 33
4.1.7 Front panel connectors................................................................................................. 33
4.2 Front panel R&S ZNBT............................................................................................... 34
4.2.1 Test ports.......................................................................................................................35
4.2.2 Administrative area....................................................................................................... 36
4.3 Rear panel R&S ZNB...................................................................................................37
4.4 Rear panel R&S ZNBT.................................................................................................39
5 Operating the instrument.................................................................... 42
5.1 Manual operation........................................................................................................ 42
5.2 Control elements of the application window............................................................47
5.2.1 Title bar......................................................................................................................... 47
5.2.2 Toolbar.......................................................................................................................... 48
5.2.3 Softtools........................................................................................................................ 49
5.2.4 Menu bar....................................................................................................................... 49
5.2.5 Menu structure.............................................................................................................. 50
5.2.6 Hardkey panel............................................................................................................... 51
5.2.7 Status bar......................................................................................................................51
5.3 Touchscreen gestures................................................................................................ 52
5.4 Working with dialogs.................................................................................................. 54
4Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
5.5 Handling diagrams, traces, and markers..................................................................55
5.5.1 Adding new traces and diagrams..................................................................................56
5.5.2 Adding new markers..................................................................................................... 57
5.5.3 Deleting display elements............................................................................................. 58
5.5.4 Using drag and drop......................................................................................................59
5.6 Entering data............................................................................................................... 59
5.6.1 Using front panel keys...................................................................................................59
5.6.2 Using the numeric editor............................................................................................... 61
5.6.3 Using the analyzer's on-screen keyboard..................................................................... 61
Contents
5.6.4
5.7.1 Using the graphical zoom..............................................................................................63
5.7.2 Setting the sweep range............................................................................................... 64
5.7.3 Reference value and position........................................................................................65
5.7.4 Auto scale..................................................................................................................... 65
5.7.5 Circular diagrams.......................................................................................................... 66
5.7.6 Set by marker................................................................................................................66
5.7.7 Enlarging a diagram...................................................................................................... 67
Using the Windows® on-screen keyboard.....................................................................62
5.7 Scaling diagrams........................................................................................................ 63
6 Performing measurements..................................................................69
6.1 Transmission S-parameter measurement.................................................................69
6.1.1 Connecting the instrument for transmission measurements......................................... 69
6.1.2 Selecting the sweep range and other parameters........................................................ 71
6.1.3 Calibrating the instrument............................................................................................. 72
6.1.4 Evaluating data............................................................................................................. 74
6.1.5 Saving and printing data............................................................................................... 75
6.2 Reflection S-parameter measurement...................................................................... 76
7 Firmware installation........................................................................... 78
8 Contacting customer support.............................................................79
Index......................................................................................................80
5Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Contents
6Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

1 Safety and regulatory information

Safety and regulatory information
Safety instructions
The product documentation helps you use the product safely and efficiently. Follow the instructions provided here and in the following chapters.
Intended use
The product is intended for the development, production and verification of electronic components and devices in industrial, administrative, and laboratory environments. Use the product only for its designated purpose. Observe the operating conditions and performance limits stated in the data sheet.
Where do I find safety information?
Safety information is part of the product documentation. It warns you of potential dan­gers and gives instructions on how to prevent personal injury or damage caused by dangerous situations. Safety information is provided as follows:
In Chapter 1.1, "Safety instructions", on page 7. The same information is provi­ded in many languages as printed "Safety Instructions". The printed "Safety Instructions" are delivered with the product.
Throughout the documentation, safety instructions are provided when you need to take care during setup or operation.

1.1 Safety instructions

Products from the Rohde & Schwarz group of companies are manufactured according to the highest technical standards. To use the products safely, follow the instructions provided here and in the product documentation. Keep the product documentation nearby and offer it to other users.
Use the product only for its intended use and within its performance limits. Intended use and limits are described in the product documentation such as the data sheet, manuals and the printed "Safety Instructions". If you are unsure about the appropriate use, contact Rohde & Schwarz customer service.
Using the product requires specialists or specially trained personnel. These users also need sound knowledge of at least one of the languages in which the user interfaces and the product documentation are available.
Never open the casing of the product. Only service personnel authorized by Rohde & Schwarz are allowed to repair the product. If any part of the product is dam­aged or broken, stop using the product. Contact Rohde & Schwarz customer service at
http://www.customersupport.rohde-schwarz.com.
Lifting and carrying the product
The R&S ZNB is not heavy (less than 18 kg fully equipped; see data sheet).
The R&S ZNBT is heavy (over 35 kg fully equipped). Do not move or carry the product by yourself. A single person can only carry a maximum of 18 kg safely depending on
7Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Safety and regulatory information
Safety instructions
age, gender and physical condition. Look up the maximum weight in the data sheet. Use the product handles to move or carry the product. Do not lift by the accessories mounted on the product. Accessories are not designed to carry the weight of the prod­uct.
To move the product safely, you can use lifting or transporting equipment such as lift trucks and forklifts. Follow the instructions provided by the equipment manufacturer.
Choosing the operating site
Only use the product indoors. The product casing is not waterproof. Water that enters can electrically connect the casing with live parts, which can lead to electric shock, serious personal injury or death if you touch the casing. If Rohde & Schwarz provides accessories designed for your product, e.g. a carrying bag, you can use the product outdoors.
Unless otherwise specified, you can operate the product up to an altitude of 2000 m above sea level. The product is suitable for pollution degree 2 environments where nonconductive contamination can occur. For more information on environmental condi­tions such as ambient temperature and humidity, see the data sheet.
Setting up the product
Always place the product on a stable, flat and level surface with the bottom of the prod­uct facing down. If the product is designed for different positions, secure the product so that it cannot fall over.
If the product has foldable feet, always fold the feet completely in or out to ensure sta­bility. The feet can collapse if they are not folded out completely or if the product is moved without lifting it. The foldable feet are designed to carry the weight of the prod­uct, but not an extra load.
If stacking is possible, keep in mind that a stack of products can fall over and cause injury.
If you mount products in a rack, ensure that the rack has sufficient load capacity and stability. Observe the specifications of the rack manufacturer. Always install the prod­ucts from the bottom shelf to the top shelf so that the rack stands securely. Secure the product so that it cannot fall off the rack.
Connecting to power
The product is an overvoltage category II product. Connect the product to a fixed installation used to supply energy-consuming equipment such as household applian­ces and similar loads. Keep in mind that electrically powered products have risks, such as electric shock, fire, personal injury or even death.
Take the following measures for your safety:
Before switching on the product, ensure that the voltage and frequency indicated on the product match the available power source. If the power adapter does not adjust automatically, set the correct value and check the rating of the fuse.
If a product has an exchangeable fuse, its type and characteristics are indicated next to the fuse holder. Before changing the fuse, switch off the product and dis-
8Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Safety and regulatory information
Safety instructions
connect it from the power source. How to change the fuse is described in the prod­uct documentation.
Only use the power cable delivered with the product. It complies with country-spe­cific safety requirements. Only insert the plug into an outlet with protective conduc­tor terminal.
Only use intact cables and route them carefully so that they cannot be damaged. Check the power cables regularly to ensure that they are undamaged. Also ensure that nobody can trip over loose cables.
If the product needs an external power supply, use the power supply that is deliv­ered with the product or that is recommended in the product documentation or a power supply that conforms to the country-specific regulations.
Only connect the product to a power source with a fuse protection of maximum 20 A.
Ensure that you can disconnect the product from the power source at any time. Pull the power plug to disconnect the product. The power plug must be easily accessible. If the product is integrated into a system that does not meet these requirements, provide an easily accessible circuit breaker at the system level.
Cleaning the product
Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that the casing is not waterproof. Do not use liquid cleaning agents.
Meaning of safety labels
Safety labels on the product warn against potential hazards.
Potential hazard
Read the product documentation to avoid personal injury or product damage.
Heavy product
Be careful when lifting, moving or carrying the product. Carrying the product requires a suffi­cient number of persons or transport equipment.
Electrical hazard
Indicates live parts. Risk of electric shock, fire, personal injury or even death.
Hot surface
Do not touch. Risk of skin burns. Risk of fire.
Protective conductor terminal
Connect this terminal to a grounded external conductor or to protective ground. This connec­tion protects you against electric shock if an electric problem occurs.
9Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

1.2 Warning messages in the documentation

1.3 Korea certification class A

Safety and regulatory information
Korea certification class A
A warning message points out a risk or danger that you need to be aware of. The sig­nal word indicates the severity of the safety hazard and how likely it will occur if you do not follow the safety precautions.
WARNING
Potentially hazardous situation. Could result in death or serious injury if not avoided.
NOTICE
Potential risks of damage. Could result in damage to the supported product or to other property.
이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.
10Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

2 Documentation overview

2.1 Getting started manual

Documentation overview
Service manual
This section provides an overview of the R&S ZNB/ZNBT user documentation. Unless specified otherwise, you find the documents on the R&S ZNB/ZNBT product page at:
https://www.rohde-schwarz.com/manual/ZNB
https://www.rohde-schwarz.com/manual/ZNBT
Introduces the R&S ZNB/ZNBT and describes how to set up and start working with the product. Includes basic operations, typical measurement examples, and general infor­mation, e.g. safety instructions, etc.
A printed version is delivered with the instrument. A PDF version is available for down­load on the Internet.

2.2 User manual and help

The user manual contains the description of all instrument modes and functions. It also provides an introduction to remote control, a complete description of the remote control commands with programming examples, and information on maintenance, instrument interfaces and error messages. Includes the contents of the getting started manual.
The contents of the user manual are available as help in the R&S ZNB/ZNBT. The help offers quick, context-sensitive access to the complete information for the instrument and its firmware.
The user manual is also available for download or for immediate display on the Inter­net.

2.3 Service manual

Describes the performance test for checking the rated specifications, module replace­ment and repair, firmware update, troubleshooting and fault elimination, and contains mechanical drawings and spare part lists.
The service manual is available for registered users on the global Rohde & Schwarz information system (GLORIS):
R&S ZNB Service Manual
R&S ZNBT Service Manual
11Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

2.4 Instrument security procedures

2.5 Printed safety instructions

2.6 Data sheets and brochures

Documentation overview
Application notes, application cards, white papers, etc.
Deals with security issues when working with the R&S ZNB/ZNBT in secure areas. It is available for download on the Internet.
Provides safety information in many languages. The printed document is delivered with the product.
The data sheet contains the technical specifications of the R&S ZNB/ZNBT. It also lists the firmware applications and their order numbers, and optional accessories.
The brochure provides an overview of the instrument and deals with the specific char­acteristics.
See
https://www.rohde-schwarz.com/brochure-datasheet/ZNB
https://www.rohde-schwarz.com/brochure-datasheet/ZNBT

2.7 Release notes and open source acknowledgment (OSA)

The release notes list new features, improvements and known issues of the current firmware version, and describe the firmware installation.
The open-source acknowledgment document provides verbatim license texts of the used open source software.

2.8 Application notes, application cards, white papers, etc.

These documents deal with special applications or background information on particu­lar topics.
See
https://www.rohde-schwarz.com/application/ZNB
https://www.rohde-schwarz.com/application/ZNBT
12Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

3 Preparing for use

3.1 Lifting and carrying

3.2 Unpacking and checking

Preparing for use
Choosing the operating site
Here, you can find basic information about setting up the product for the first time.
The carrying handles are designed to lift or carry the instrument. Do not apply exces­sive external force to the handles.
See "Lifting and carrying the product" on page 7.
1. Unpack the R&S ZNB/ZNBT carefully.
2. Retain the original packing material. Use it when transporting or shipping the
R&S ZNB/ZNBT later.
3. Using the delivery notes, check the equipment for completeness.
4. Check the equipment for damage.
If the delivery is incomplete or equipment is damaged, contact Rohde & Schwarz.

3.3 Choosing the operating site

Specific operating conditions ensure proper operation and avoid damage to the prod­uct and connected devices. For information on environmental conditions such as ambi­ent temperature and humidity, see the data sheet.
See also "Choosing the operating site" on page 8.
Electromagnetic compatibility classes
The electromagnetic compatibility (EMC) class indicates where you can operate the product. The EMC class of the product is given in the data sheet.
Class B equipment is suitable for use in:
Residential environments
Environments that are directly connected to a low-voltage supply network that
supplies residential buildings
Class A equipment is intended for use in industrial environments. It can cause radio disturbances in residential environments due to possible conducted and radi­ated disturbances. It is therefore not suitable for class B environments.
13Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

3.4 Setting up the product

3.4.1 Placing the product on a bench top

Preparing for use
Setting up the product
If class A equipment causes radio disturbances, take appropriate measures to eliminate them.
See also:
"Setting up the product" on page 8
"Intended use" on page 7
To place the product on a bench top
1. Place the product on a stable, flat and level surface. Ensure that the surface can
support the weight of the product. For information on the weight, see the data sheet.
WARNING! A stack of products can fall over and cause injury. Never stack more
2.
than two products. Otherwise, mount them in a rack.
Stack as follows:
All products must have the same dimensions (width and length).
Do not exceed a total load of 50 kg placed on the product at the bottom of the
stack.
= Stacked correctly
Left Right = Stacked incorrectly, too many products
NOTICE! Overheating can damage the product.
3.
Prevent overheating as follows:
Keep a minimum distance of 10 cm between the fan openings of the product
and any object in the vicinity.
14Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

3.4.2 Mounting the product in a rack

Preparing for use
Considerations for test setup
Do not place the product next to heat-generating equipment such as radiators or other products.
To prepare the rack
1. Observe the requirements and instructions in "Setting up the product" on page 8.
NOTICE! Insufficient airflow can cause overheating and damage the product.
2.
Design and implement an efficient ventilation concept for the rack.
To mount the R&S ZNB/ZNBT in a rack
1. Use an adapter kit to prepare the R&S ZNB/ZNBT for rack mounting.
a) Order the rack adapter kit R&S ZZA-KN5 (order number 1175.3040.00). b) Mount the adapter kit. Follow the assembly instructions provided with the
adapter kit.
2. Lift the R&S ZNB/ZNBT to shelf height.
3. Grab the handles and push the R&S ZNB/ZNBT onto the shelf until the rack brack-
ets fit closely to the rack.
4. Tighten all screws in the rack brackets with a tightening torque of 1.2 Nm to secure the R&S ZNB/ZNBT in the rack.
To unmount the R&S ZNB/ZNBT from a rack
1. Loosen the screws at the rack brackets.
2. Remove the R&S ZNB/ZNBT from the rack.
3. If placing the R&S ZNB/ZNBT on a bench top again, unmount the adapter kit from the R&S ZNB/ZNBT. Follow the instructions provided with the adapter kit.

3.5 Considerations for test setup

Cable selection and electromagnetic interference (EMI)
Electromagnetic interference (EMI) can affect the measurement results.
To suppress electromagnetic radiation during operation:
Use high-quality shielded cables, for example, double-shielded RF and LAN cables.
Always terminate open cable ends.
Ensure that connected external devices comply with EMC regulations.
15Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Preparing for use
Connecting the analyzer to the AC supply
Regarding length and quality, the following requirements have to be met for cable that are directly connected to the R&S ZNB/ZNBT:
Table 3-1: Cable Requirements
Cable Type (Connector) Requirement
RF cables (PORT 1, ..., PORT N) Double shielded
BNC cables (various) Double shielded
DB-25 (User Port) Double shielded
Digital I/Q (DIRECT CTRL, AUX CONTROL) R&S order no. 1402.4990.00 only
GPIB Standard cable
Handler I/O Standard cable
RFFE/GPIO R&S ZN-Z25 (order no. 1334.3424.02) only
DisplayPort (Monitor) Standard cable
DVI-D (Monitor) 2 ferrite cores
LAN At least CAT6, S/FTP
PCIe Standard cable
USB Standard cables, length ≤ 3m
Signal input and output levels
Information on signal levels is provided in the data sheet. Keep the signal levels within the specified ranges to avoid damage to the product and connected devices.
Preventing electrostatic discharge (ESD)
Electrostatic discharge is most likely to occur when you connect or disconnect a DUT.
NOTICE! Electrostatic discharge can damage the electronic components of the
product and the device under test (DUT).
Ground yourself to prevent electrostatic discharge damage:
a) Use a wrist strap and cord to connect yourself to ground. b) Use a conductive floor mat and heel strap combination.
During operation, if the firmware observes a serious unexpected disturbance (e.g. due to ESD), it resets all hardware components to ensure proper instrument functioning. It then restores the user settings to the state before the disturbance and indicates the foregone hardware reset by an "Hardware communication problem [...]" information popup.

3.6 Connecting the analyzer to the AC supply

For safety information, see "Connecting to power" on page 8.
16Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Preparing for use
Switching the instrument on and off
The network analyzer is automatically adapted to the AC supply voltage, which must be in the range of 100 V to 240 V at 50 Hz to 60 Hz. A line frequency of 400 Hz is also supported.
The AC power connector is located in the upper part of the rear panel (see Chap-
ter 4.3, "Rear panel R&S ZNB", on page 37 or Chapter 4.4, "Rear panel R&S ZNBT",
on page 39).
1. Plug the AC power cable into the AC power connector on the rear panel of the product. Only use the AC power cable delivered with the product.
2. Plug the AC power cable into a power outlet with ground contact.
The required ratings are listed next to the AC power connector and in the data sheet.
3.
If necessary, also ground the product using the grounding terminal
The maximum power consumption and the typical power consumption of the individual analyzer models are listed in the data sheet.
The R&S ZNBT is protected by a fuse located below the AC power switch. For fuse replacement, see the corresponding section in the maintenance chapter of the user manual. There is no such fuse on the R&S ZNB.
Risk of data loss due to voltage dips
For a R&S ZNBT40 with 24 ports, a voltage dip with a duration of 18 ms or higher can cause a spontaneous reboot of the instrument. I.e. in its maximum configuration, the R&S ZNBT40 does not fully comply with standard EN 61326-2-1, chapter 6.4.101.
The reboot time is approximately 90 s. Note that the instrument settings after a sponta­neous reboot are those that were active before the most recent regular shutdown or reboot. Settings that have been changed since then are lost. To preserve changes in the active setup, you must perform a regular shutdown or reboot.
.

3.7 Switching the instrument on and off

To switch on the R&S ZNB/ZNBT
1. Switch the AC power switch to position I (On). The AC power switch is located in the upper part of the rear panel, together with the mains connector and the fuse drawer (R&S ZNBT only; see Chapter 4.3, "Rear
panel R&S ZNB", on page 37 or Chapter 4.4, "Rear panel R&S ZNBT",
on page 39).
17Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Preparing for use
Standby and ready state
After power-on, the analyzer automatically goes to standby or ready state, depend­ing on the state of the standby toggle key at the front panel when the instrument was switched off last time.
2. If necessary, press the standby toggle key on the front panel to switch the instru­ment to ready state.
See Chapter 3.8, "Standby and ready state", on page 18
The instrument automatically performs a system check, boots the Windows® oper­ating system and then starts the vector network analyzer (VNA) application. If it was terminated regularly, the VNA application restores all recall sets and instru­ment settings of the previous analyzer session.
To shut down the instrument
1. Press the standby toggle key.
Pressing the standby toggle key causes the instrument to save all loaded recall sets, to close the VNA application, to shut down Windows®, and to go to standby state (see Chapter 3.8, "Standby and ready state", on page 18). Of course, you can also perform these steps manually, like in any Windows ses­sion.
2. If desired, set the AC power switch to position O (Off).
To disconnect from power
The R&S ZNB/ZNBT is in standby state.
NOTICE! Risk of data loss. If you disconnect the product from power when it is in
1. the ready state, you can lose settings and data. Shut it down first.
Set the switch on the power supply to position [0].
The LED of the standby toggle key key is switched off.
2. Disconnect the R&S ZNB/ZNBT from the power source.

3.8 Standby and ready state

R&S ZNB: The standby toggle key is located in the bottom-left corner of the front
panel. In standby state, the right, amber LED is on, in ready state, the left, green LED is on.
R&S ZNBT: The standby toggle key is located in the bottom-right corner of the front panel. In standby state, the PWR LED light is amber, in ready state it is green.
The standby power only supplies the power switch circuits and the optional oven quartz (option R&S ZNB-B4/R&S ZNBT-B4, "OCXO Frequency Reference"). In this state, it is safe to switch the AC power off and disconnect the instrument from the power supply. In ready state, all modules are power-supplied. When switched to ready state, the analyzer initiates its startup procedure.
18Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

3.9 Windows operating system

Preparing for use
Windows operating system
Observe the instructions for startup and shutdown in Chapter 3.7, "Switching the instru-
ment on and off", on page 17.
The analyzer is equipped with a Windows® operating system which has been config­ured according to the instrument's features and needs. Changes in the system configu­ration can be necessary to:
Establish a LAN connection
Customize the properties of the external accessories connected to the analyzer
Call up additional software tools
Modifications of the operating system
The operating system is adapted to the network analyzer. To avoid impairment of instrument functions, only change the settings described in this manual. Existing soft­ware must be modified only with update software released by Rohde & Schwarz. Like­wise, only programs authorized by Rohde & Schwarz for use on the instrument must be executed.
All necessary settings can be accessed from the Windows "Start" menu, in particular from the "Control Panel". To open the "Start" menu, press the Windows key in the tool­bar or on an external keyboard.
User accounts and password protection
The analyzer uses a user name and password as credentials for remote access. Two user accounts with different levels of access are available on the instrument:
"instrument" is the default account with standard rights to change system settings. Use this account for normal operation of the analyzer.
"Admin" is the account for administering the operating system. This account is required, for instance, if you wish to install programs on the analyzer. [For instruments running Windows 7, this account is named "Administrator".]
In the factory configuration, "894129" is preset as a password for both users. To protect the analyzer from unauthorized access, it is recommended to change the preset pass­words.
To switch from one user account to another, log off from Windows and then log on again. The "switch user" functionality is disabled on the R&S ZNB/ZNBT.
Service packs and updates
Microsoft regularly creates security updates and other patches to protect Windows­based operating systems. They are released through the Microsoft Update website and
19Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Preparing for use
Minimizing the VNA application
associated update server. Update instruments using Windows regularly, especially instruments that connect to a network.
Firewall settings
A firewall protects an instrument by preventing unauthorized users from gaining access to it through a network. Rohde & Schwarz highly recommends using the firewall on your instrument. Rohde & Schwarz instruments are shipped with the Windows firewall enabled. All ports and connections for remote control are enabled.
Note that changing firewall settings requires administrator rights.
Virus protection
Take appropriate steps to protect your instruments from infection. Use strong firewall settings and scan any removable storage device used with a Rohde & Schwarz instru­ment regularly. It is also recommended that you install anti-virus software on the instru­ment. Rohde & Schwarz does NOT recommend running anti-virus software in the background ("on-access" mode) on Windows-based instruments, due to potentially degrading instrument performance. However, Rohde & Schwarz does recommend run­ning it during non-critical hours.
For details and recommendations, see the following Rohde & Schwarz white paper:
1EF96: Malware Protection Windows 10
Windows 7: 1DC01: Malware Protection Windows 7

3.10 Minimizing the VNA application

With a minimized VNA application, you can access your analyzer's Windows® desktop or run other applications.
To exit the default full-screen mode of the VNA application, deselect System – [Display] > "View Bar" > "Title Bar Task Bar". Then use the standard Windows® titlebar functions to minimize/maximize/close the application window.
To start the VNA application with a minimized window
1. Right-click the Vector Network Analyzer shortcut icon on the desktop and open the "Properties" dialog.
2. In the "Shortcut" tab, select "Run: Minimized".
20Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Preparing for use
Connecting external accessories
A software update restores the original shortcut properties.

3.11 Connecting external accessories

The analyzer's standard PC interfaces (Monitor, USB, LAN) can be used to connect various accessories:
An external monitor expands/displays the Windows® desktop, which is, by default, covered by the vector network analyzer (VNA) (VNA) application window in full­screen mode.
External keyboard and mouse enable/simplify local control, in particular manual (GUI) operation of the VNA application.
A printer can be used to create hard copies of the measurement diagrams and traces from within the VNA application.
A LAN connection can be established to access the analyzer's mass storage or control the analyzer from an external PC.
Instruments equipped with the latest controller board can also be remote controlled via USB.
For the R&S ZNBT, external monitor and mouse are required for local operation. The R&S ZNB can be fully controlled by tapping the touchscreen and front panel keys.

3.11.1 Connecting a monitor

A standard monitor can be connected to the DVI-D connector of the R&S ZNB/ZNBT. No extra configuration is required.
Instruments equipped with the latest controller board also offer a DisplayPort.
21Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT
Preparing for use
Connecting external accessories
Safety aspects
The monitor must be connected while the instrument is switched off (or in standby mode). Otherwise correct operation cannot be guaranteed.
Select System > [Display] > "View Bar" > "Hard Key Panel On" from the menu bar of the VNA application window to add the (virtual) "Hard Key Panel" to the application window.
Changing the Screen Resolution (R&S ZNBT)
In case the R&S ZNBT fails to adjust the display resolution properly when an external monitor is connected, proceed as follows:
1. Connect a USB keyboard and mouse as described in Chapter 3.11.6, "Connecting
a USB cable for remote control", on page 24.
2. Hold the Ctrl key and press Esc to show the task bar.
3. Click the rectangular button rightmost on the task bar to show the Windows desk­top.
4. Right-click the Windows desktop and select "Display settings" from the context menu ( "Screen resolution" in Windows 7)
5. In the Windows display management
a) Change the "Multiple displays" setting to "Show desktop only on 2"; apply and
confirm the modified settings ("Keep Changes") b) Select Display 2 in the panel at the top. c) Change the display "Resolution" to the desired value by dragging the slider;
click "OK" and confirm the modified settings ("Keep Changes")

3.11.2 Connecting a keyboard

A keyboard can be connected to any of the USB connectors. After being auto-detected by the operating system, it can safely be disconnected and reconnected even during measurements.
Keyboard configuration
The default input language is English – US. Select "Settings" > "Time & language" > "Region & language" from the Windows® Start menu to manage languages and key­boards.
Windows 7: select "Control Panel" > "Clock, Language, and Region" > "Region and Language" > "Keyboards and Languages" from the Windows® Start menu to configure the keyboard properties.
22Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

3.11.3 Connecting a mouse

Preparing for use
Connecting external accessories
To access Windows®, use the button in the toolbar of the application window.
A USB mouse can be connected to any of the USB connectors. After being auto-detec­ted by the operating system, it can safely be disconnected and reconnected even dur­ing measurements.
Mouse configuration
Select "Settings" > "Devices" > "Mouse & touchpad" from the Windows® "Start" menu to configure the mouse properties.
Windows 7: select "Control Panel" > "Hardware and Sound" > "Devices and Printers" > "Mouse" from the Windows® "Start" menu to configure the mouse properties.
To access Windows®, use the

3.11.4 Connecting a printer

A printer can be connected to any of the USB connectors. After successful installation, it can safely be disconnected and reconnected even during measurements.
Before printing (System – [Print]), the analyzer checks whether a printer is connected and turned on and whether the appropriate printer driver is installed.
Printer driver installation
If necessary, the printer driver installation is initiated using the operating system's "Add Printer Wizard". The wizard is self-explanatory. A printer driver must be installed only once.
A great variety of printer drivers is available on the analyzer. To obtain the complete list, select "Settings" > "Devices" > "Printers & scanners" from the Windows® "Start" menu.
Windows 7: select "Control Panel" > "Hardware and Sound" > "Devices and Printers" from the Windows® "Start" menu.
button in the toolbar of the application window.
To access Windows®, use the
You can load updated and improved driver versions or new drivers from an installation disk, USB memory stick or another external storage medium. Alternatively, if the ana­lyzer is integrated in a network, you can install driver data stored in a network directory. In either case, use the "Add Printer" wizard to complete the installation.
button in the toolbar of the application window.
23Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

3.11.5 Connecting a LAN cable

Preparing for use
Remote operation in a LAN
Printer configuration
Use the "Printer Setup" dialog of the firmware (System – [Print] > "Print...") or the Win­dows® printer management to configure the printer properties and printing preferences.
A LAN cable can be connected to the LAN connector on the rear panel of the analyzer. To establish a LAN connection, proceed as follows:
1. Refer to Chapter 3.12.1, "Assigning an IP address", on page 25.
2. Connect a CAT6 or CAT7 LAN cable to the LAN port.
The LAN port of the analyzer is an auto-crossover Ethernet port. You can connect it to a network, but you can also set up a direct connection to a computer or another instru­ment. For both connection types, you can use either crossover or straight through (patch) cables.
The IP address information is shown in the System – [Setup] > "Remote Settings" soft­tool tab. For the R&S ZNBT, it is also shown on the Mini display.

3.11.6 Connecting a USB cable for remote control

Instruments equipped with the latest controller board can also be remote controlled via USB. To prepare for remote control operation, connect a suitable USB 2.0 or 3.0 cable to the type B "USB Device" port on the rear panel of the instrument. With direct con­nection to a master device, a connecting cable A-B (plug type A onto plug type B) must be used.
For more information, refer to the Remote Control chapter of your analyzer's help sys­tem or user manual.

3.12 Remote operation in a LAN

A LAN connection is used to integrate the analyzer into a home/company network. LAN connectivity offers several applications, e.g.:
Transfer data between a controller and the analyzer, e.g. to run a remote control program.
Control the measurement from a remote computer using Remote Desktop or a sim­ilar application.
Use external network devices (e.g. printers).
The analyzer uses a user name and password as credentials for remote access; see note on "User accounts and password protection" on page 19 for details. To protect the analyzer from unauthorized access, it is recommended to change the factory setting.
24Getting Started 1316.0062.02 ─ 62
R&S®ZNB/ZNBT

3.12.1 Assigning an IP address

Preparing for use
Remote operation in a LAN
Depending on the network capacities, the TCP/IP address information for the analyzer can be obtained in different ways.
If the network supports dynamic TCP/IP configuration using the Dynamic Host Configuration Protocol (DHCP), all address information can be assigned automati­cally.
If the network does not support DHCP, or if the analyzer is set to use alternate TCP/IP configuration, the addresses must be set manually.
By default, the analyzer is configured to use dynamic TCP/IP configuration and obtain all address information automatically. Hence it is safe to establish a physical connec­tion to the LAN without any previous analyzer configuration.
Manual TCP/IP configuration
If your network does not support DHCP, or if you choose to disable dynamic TCP/IP configuration, you must assign valid address information before you connect the ana­lyzer to the LAN. Contact your network administrator to obtain a valid IP address, because connection errors can affect the entire network.
Admin account
You need administrator rights to change the TCP/IP configuration. See note on "User
accounts and password protection" on page 19 for details.
The R&S ZNBT provides a miniature display in the upper right-hand corner of the front panel indicating the current IP address of the instrument. See Mini display.
To enter the TCP/IP address information manually
1. Obtain the IP address and subnet mask for the analyzer and the IP address for the local default gateway from your network administrator. If necessary, also obtain the name of your DNS domain and the IP addresses of the DNS and WINS servers on your network.
2. For the R&S ZNBT, connect an external monitor, keyboard and mouse.
3. Press the Windows key in the System keypad (R&S ZNB only) or on an external
keyboard to access Windows®.
4. Open the "Control Panel" > "Network and Sharing Center" > "Change adapter set­tings" dialog and right-click the local connection. Windows 7: open the "Control Panel" > "Network and Internet" > "Network and Sharing Center" > "Local Area Connection Status" dialog.
5. Select "Properties" and confirm the user account control message, depending on your current user account.
25Getting Started 1316.0062.02 ─ 62
Loading...
+ 56 hidden pages