Subject to change – data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
1432.7046.02 | Version 04 | R&S®SMCV100B
The following abbreviations are used throughout this manual: R&S®SMCV100B is abbreviated as
R&S SMCV100B, R&S®WinIQSIM2TM is abbreviated as R&S WinIQSIM2, R&S®VISA is abbreviated as
R&S VISA.
R&S®SMCV100B
Contents
1 Safety and regulatory information....................................... 7
The product documentation helps you use the product safely and efficiently. Follow the instructions provided here and in the following chapters.
Intended use
The product is intended for the development, production and verification of electronic components and devices in industrial, administrative, and laboratory environments. Use the product only for its designated purpose. Observe the operating
conditions and performance limits stated in the data sheet.
Where do I find safety information?
Safety information is part of the product documentation. It warns you of potential
dangers and gives instructions on how to prevent personal injury or damage
caused by dangerous situations. Safety information is provided as follows:
●
In Chapter 1.1, "Safety instructions", on page 7. The same information is
provided in many languages as printed "Safety Instructions". The printed
"Safety Instructions" are delivered with the product.
●
Throughout the documentation, safety instructions are provided when you
need to take care during setup or operation.
1.1Safety instructions
Products from the Rohde & Schwarz group of companies are manufactured
according to the highest technical standards. To use the products safely, follow
the instructions provided here and in the product documentation. Keep the product documentation nearby and offer it to other users.
Use the product only for its intended use and within its performance limits. Intended use and limits are described in the product documentation such as the data
sheet, manuals and the printed "Safety Instructions". If you are unsure about the
appropriate use, contact Rohde & Schwarz customer service.
Using the product requires specialists or specially trained personnel. These users
also need sound knowledge of at least one of the languages in which the user
interfaces and the product documentation are available.
7Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Never open the casing of the product. Only service personnel authorized by
Rohde & Schwarz are allowed to repair the product. If any part of the product is
damaged or broken, stop using the product. Contact Rohde & Schwarz customer
service at http://www.customersupport.rohde-schwarz.com.
Lifting and carrying the product
The maximum weight of the product is provided in the data sheet. To move the
product safely, you can use lifting or transporting equipment such as lift trucks
and forklifts. Follow the instructions provided by the equipment manufacturer.
Choosing the operating site
Only use the product indoors. The product casing is not waterproof. Water that
enters can electrically connect the casing with live parts, which can lead to electric shock, serious personal injury or death if you touch the casing. If
Rohde & Schwarz provides accessories designed for your product, e.g. a carrying
bag, you can use the product outdoors.
Safety and regulatory information
Safety instructions
Unless otherwise specified, you can operate the product up to an altitude of
2000 m above sea level. The product is suitable for pollution degree 2 environments where nonconductive contamination can occur. For more information on
environmental conditions such as ambient temperature and humidity, see the
data sheet.
Setting up the product
Always place the product on a stable, flat and level surface with the bottom of the
product facing down. If the product is designed for different positions, secure the
product so that it cannot fall over.
If the product has foldable feet, always fold the feet completely in or out to ensure
stability. The feet can collapse if they are not folded out completely or if the product is moved without lifting it. The foldable feet are designed to carry the weight of
the product, but not an extra load.
If stacking is possible, keep in mind that a stack of products can fall over and
cause injury.
If you mount products in a rack, ensure that the rack has sufficient load capacity
and stability. Observe the specifications of the rack manufacturer. Always install
the products from the bottom shelf to the top shelf so that the rack stands
securely. Secure the product so that it cannot fall off the rack.
8Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Connecting to power
The product is an overvoltage category II product. Connect the product to a fixed
installation used to supply energy-consuming equipment such as household
appliances and similar loads. Keep in mind that electrically powered products
have risks, such as electric shock, fire, personal injury or even death.
Take the following measures for your safety:
●
Before switching on the product, ensure that the voltage and frequency indicated on the product match the available power source. If the power adapter
does not adjust automatically, set the correct value and check the rating of the
fuse.
●
Only use the power cable delivered with the product. It complies with countryspecific safety requirements. Only insert the plug into an outlet with protective
conductor terminal.
●
Only use intact cables and route them carefully so that they cannot be damaged. Check the power cables regularly to ensure that they are undamaged.
Also ensure that nobody can trip over loose cables.
Safety and regulatory information
Safety instructions
●
If the product needs an external power supply, use the power supply that is
delivered with the product or that is recommended in the product documentation or a power supply that conforms to the country-specific regulations.
●
Only connect the product to a power source with a fuse protection of maximum 20 A.
●
Ensure that you can disconnect the product from the power source at any
time. Pull the power plug to disconnect the product. The power plug must be
easily accessible. If the product is integrated into a system that does not meet
these requirements, provide an easily accessible circuit breaker at the system
level.
Cleaning the product
Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that
the casing is not waterproof. Do not use liquid cleaning agents.
Meaning of safety labels
Safety labels on the product warn against potential hazards.
9Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Safety and regulatory information
Warning messages in the documentation
Potential hazard
Read the product documentation to avoid personal injury or product damage.
Electrical hazard
Indicates live parts. Risk of electric shock, fire, personal injury or even death.
Hot surface
Do not touch. Risk of skin burns. Risk of fire.
Protective conductor terminal
Connect this terminal to a grounded external conductor or to protective ground. This
connection protects you against electric shock if an electric problem occurs.
1.2Labels on R&S SMCV100B
Labels on the casing inform about:
●
Personal safety, see "Connecting to power"on page 9.
●
Product and environment safety, see Table 1-1.
●
Identification of the product, see the serial number on the rear panel.
Table 1-1: Labels regarding R&S SMCV100B and environment safety
Labeling in line with EN 50419 for disposal of electrical and electronic equipment after
the product has come to the end of its service life. For more information, see the product user manual, chapter "Disposal".
1.3Warning messages in the documentation
A warning message points out a risk or danger that you need to be aware of. The
signal word indicates the severity of the safety hazard and how likely it will occur
if you do not follow the safety precautions.
WARNING
Potentially hazardous situation. Could result in death or serious injury if not avoided.
10Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
CAUTION
Potentially hazardous situation. Could result in minor or moderate injury if not
avoided.
NOTICE
Potential risks of damage. Could result in damage to the supported product or to
other property.
Safety and regulatory information
Korea certification class B
1.4Korea certification class B
이 기기는 가정용(B급) 전자파 적합기기로서 주로 가정에서 사용하는 것을 목적으
로 하며, 모든 지역에서 사용할 수 있습니다.
11Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Documentation overview
User manuals and help
2Documentation overview
This section provides an overview of the R&S SMCV100B user documentation.
Unless specified otherwise, you find the documents on the R&S SMCV100B
product page at:
www.rohde-schwarz.com/manual/smcv100b
2.1Getting started manual
Introduces the R&S SMCV100B and describes how to set up and start working
with the product. Includes basic operations, typical measurement examples, and
general information, e.g. safety instructions, etc. A printed version is delivered
with the instrument.
2.2User manuals and help
Separate manuals for the base unit and the software options are provided for
download:
●
Base unit manual
Contains the description of all instrument modes and functions. It also provides an introduction to remote control, a complete description of the remote
control commands with programming examples, and information on maintenance, instrument interfaces and error messages. Includes the contents of the
getting started manual.
●
Software option manual
Contains the description of the specific functions of an option. Basic information on operating the R&S SMCV100B is not included.
The contents of the user manuals are available as help in the R&S SMCV100B.
The help offers quick, context-sensitive access to the complete information for the
base unit and the software options.
All user manuals are also available for download or for immediate display on the
Internet.
12Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Documentation overview
Data sheets and brochures
2.3Service manual
Describes the performance test for checking compliance with rated specifications,
firmware update, troubleshooting, adjustments, installing options and maintenance.
The service manual is available for registered users on the global
Rohde & Schwarz information system (GLORIS):
https://gloris.rohde-schwarz.com
2.4Instrument security procedures
Deals with security issues when working with the R&S SMCV100B in secure
areas. It is available for download on the Internet.
2.5Printed safety instructions
Provides safety information in many languages. The printed document is delivered with the product.
2.6Data sheets and brochures
The data sheet contains the technical specifications of the R&S SMCV100B. It
also lists the options and their order numbers and optional accessories.
The brochure provides an overview of the instrument and deals with the specific
characteristics.
See www.rohde-schwarz.com/brochure-datasheet/smcv100b
13Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Application notes, application cards, white papers, etc.
Documentation overview
2.7Release notes and open source acknowledgment (OSA)
The release notes list new features, improvements and known issues of the current firmware version, and describe the firmware installation.
The open-source acknowledgment document provides verbatim license texts of
the used open source software.
See www.rohde-schwarz.com/firmware/smcv100b
2.8Application notes, application cards, white
papers, etc.
These documents deal with special applications or background information on
particular topics.
See www.rohde-schwarz.com/application/smcv100b
14Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Key features
3Key features
The R&S SMCV100B is a new signal generator in the economy range developed
to meet demanding customer requirements. Offering excellent signal characteristic and straightforward and intuitive operation, the signal generator makes signal
generation fast and easy.
Outstanding key features of the R&S SMCV100B are:
●
First multi-standard platform for broadcast, navigation, cellular and wireless
applications
●
Fully software-defined vector signal generator
●
Modern RF signal generation concept from 8kHz to 7.125GHz
●
High RF output power of up to 25dBm
●
Modulation bandwidth up to 240 MHz with internal baseband
●
Powerful internal baseband generator with internal broadcast real-time coder,
Custom Digital Modulation and internal baseband signal generation with ARB
●
Support of various broadcast standards covering multiple fields of application:
Support of digital standard waveforms such as 5G NR, LTE including
eMTC/NB-IoT, WLAN IEEE 802.11a/b/g/n/j/p/ac/ax/be, GNSS
●
Intuitive operation via 5'' touchscreen with block diagram as key element
●
Graphical signal monitoring at practically every point in the signal flow
●
SCPI macro recorder and code generator for generating executable remote
control code from manual operating steps (for MATLAB®, CVI, etc.)
●
Easily extendable with software options
●
Full remote compatibility with R&S SFE/R&S SFE100
For more information, see data sheet.
15Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Choosing the operating site
Preparing for use
4Preparing for use
Here, you can find basic information about setting up the product for the first time.
4.1Lifting and carrying
See also "Lifting and carrying the product"on page 8.
For mounting the R&S SMCV100B in a rack, see Chapter 4.4.2, "Mounting the
R&S SMCV100B in a rack", on page 18.
4.2Unpacking and checking
1. Unpack the R&S SMCV100B carefully.
2. Retain the original packing material. Use it to protect the control elements and
connectors when transporting or shipping the R&S SMCV100B later.
See also chapter "Transporting" in the user manual.
3. Using the delivery notes, check the equipment for completeness.
4. Check the equipment for damage.
If the delivery is incomplete or equipment is damaged, contact
Rohde & Schwarz.
4.3Choosing the operating site
Specific operating conditions ensure proper operation and avoid damage to the
product and connected devices. For information on environmental conditions
such as ambient temperature and humidity, see the data sheet.
See also "Choosing the operating site"on page 8.
16Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Setting up the R&S SMCV100B
Electromagnetic compatibility classes
The electromagnetic compatibility (EMC) class indicates where you can operate
the product. The EMC class of the product is given in the data sheet under "General data".
●
Class B equipment is suitable for use in:
–Residential environments
–Environments that are directly connected to a low-voltage supply network
that supplies residential buildings
●
Class A equipment is intended for use in industrial environments. It can cause
radio disturbances in residential environments due to possible conducted and
radiated disturbances. It is therefore not suitable for class B environments.
If class A equipment causes radio disturbances, take appropriate measures to
eliminate them.
Preparing for use
4.4Setting up the R&S SMCV100B
See also:
●
"Setting up the product"on page 8
●
"Intended use"on page 7
4.4.1Placing the R&S SMCV100B on a bench top
To place the product on a bench top
1. Place the product on a stable, flat and level surface. Ensure that the surface
can support the weight of the product. For information on the weight, see the
data sheet.
2. CAUTION! Foldable feet can collapse. See "Setting up the product"
on page 8.
Always fold the feet completely in or out. With folded-out feet, do not place
anything on top or underneath the product.
3. WARNING! A stack of products can fall over and cause injury. Never stack
more than three products on top of each other. Instead, mount them in a rack.
Stack as follows:
17Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Preparing for use
Setting up the R&S SMCV100B
●If the products have foldable feet, fold them in completely.
●All products must have the same dimensions (width and length).
●Do not exceed a total load of 50 kg placed on the product at the bottom of
the stack.
Left= Stacked correctly
Middle left = Stacked incorrectly, too many products
Middle right = Stacked incorrectly, different dimensions
Right= Stacked incorrectly, different dimensions, folded-out feet
4. NOTICE! Overheating can damage the product.
Prevent overheating as follows:
●Keep a minimum distance of 10 cm between the fan openings of the prod-
uct and any object in the vicinity.
●Do not place the product next to heat-generating equipment such as radiators or other products.
4.4.2Mounting the R&S SMCV100B in a rack
To prepare the rack
1. Observe the requirements and instructions in "Setting up the product"
on page 8.
2. NOTICE! Insufficient airflow can cause overheating and damage the product.
Design and implement an efficient ventilation concept for the rack.
To mount the R&S SMCV100B in a rack
1. Use an adapter kit that fits the dimensions of the R&S SMCV100B to prepare
the instrument for rack mounting.
a) Order the rack adapter kit designed for the R&S SMCV100B. For the order
number, see data sheet.
18Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Considerations for test setup
b) Mount the adapter kit. Follow the assembly instructions provided with the
adapter kit.
2. Lift the R&S SMCV100B to shelf height.
3. Push the R&S SMCV100B onto the shelf until the rack brackets fit closely to
the rack.
4. Tighten all screws at the rack brackets with a tightening torque of 1.2 Nm to
secure the R&S SMCV100B in the rack.
To unmount the R&S SMCV100B from a rack
1. Loosen the screws at the rack brackets.
2. Bring the lifting equipment to shelf height.
3. Remove the R&S SMCV100B from the rack.
Preparing for use
4. If placing the R&S SMCV100B on a bench top again, unmount the adapter kit
from the R&S SMCV100B. Follow the instructions provided with the adapter
kit.
4.5Considerations for test setup
Cable selection and electromagnetic interference (EMI)
Electromagnetic interference (EMI) can affect the measurement results.
To suppress electromagnetic radiation during operation:
●
Use high-quality shielded cables, especially for the following connector types:
–BNC
Double-shielded BNC cables.
How to: "To connect to non-screwable connectors (BNC)"on page 23
–USB
Double-shielded USB cables.
How to: Chapter 4.9, "Connecting USB devices", on page 22.
See also chapter "Measuring USB cable quality" in the user manual.
–LAN
At least CAT6 STP cables.
How to: Chapter 4.7, "Connecting to LAN", on page 20
19Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
●
Always terminate open cable ends.
●
Ensure that connected external devices comply with EMC regulations.
●
Use the cable R&S DIGIQ-HS for connection to the Dig. IQ HS x interfaces of
the instrument. The cable is available under material number 3641.2948.03.
How to: Chapter 4.12, "Connecting to Dig. IQ HS x", on page 24
●
Use an SFP+ to RJ-45 adapter and an RJ-45 cable for connection to the IP
Data interface of the instrument. We recommend that you use the adapter
"FCLF850P2BTL" from Finisar available under material number
3627.0570.00.
How to: Chapter 4.13, "Connecting to IP Data interface", on page 26
Signal input and output levels
Information on signal levels is provided in the data sheet. Keep the signal levels
within the specified ranges to avoid damage to the R&S SMCV100B and connected devices.
Preparing for use
Connecting to LAN
4.6Connecting to power
For safety information, see "Connecting to power"on page 9.
1. Plug the AC power cable into the AC power connector on the rear panel of the
instrument. Only use the AC power cable delivered with the R&S SMCV100B.
2. Plug the AC power cable into a power outlet with ground contact.
The required ratings are listed next to the AC power connector and in the data
sheet.
4.7Connecting to LAN
Network environment
Before connecting the product to a local area network (LAN), consider the following:
●
Install the latest firmware to reduce security risks.
●
For internet or remote access, use secured connections if applicable.
20Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
●
Ensure that the network settings comply with the security policies of your company. Contact your local system administrator or IT department before connecting your product to your company LAN.
●
When connected to the LAN, the product may potentially be accessed from
the internet, which may be a security risk. For example, attackers might misuse or damage the product.
To connect to LAN
The connector is located on the rear panel.
► Connect the LAN socket via an RJ-45 cable to the LAN.
By default, the R&S SMCV100B is configured to use DHCP (dynamic host configuration protocol) and no static IP address is configured.
If switched on and connected to the LAN, the R&S SMCV100B displays the
address information on the screen.
Preparing for use
Connecting a monitor
Figure 4-1: IP address indication on the screen (example)
See also the chapter "Connecting the Instrument to the Network (LAN)" in the
user manual.
4.8Connecting a monitor
This section describes how to connect a monitor for direct operation of the
R&S SMCV100B. You can skip the following procedure, if you only operate the
R&S SMCV100B remotely.
The connector is located on the rear panel.
► Connect the monitor to the DVI-D socket.
You can connect the following types of monitor sockets:
●DVI-D: Connect it to the DVI-D socket.
DVI-A: not supported
DVI-I: not supported
21Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Connecting USB devices
●HDMI: You need an adapter. Use a passive DVI to HDMI adapter.
●VGA: You need an active adapter, DVI to VGA or Display Port to VGA.
Passive adapters do not work.
If the monitor provides touch functionality, an additional connection can be
required, for example, a USB connection. Refer to the documentation of your
monitor.
Preparing for use
4.9Connecting USB devices
You can connect or disconnect all USB devices from the R&S SMCV100B during
operation.
To connect USB storage devices
USB storage devices, such as memory sticks, allow data transfer from or to the
R&S SMCV100B. You can also use them for firmware updates.
► Connect the USB storage device to a USB type A connector.
When connecting to the front panel, connect the USB storage device directly,
without connecting cable. Connecting cables can cause electromagnetic radiation and impair a measurement result.
To connect USB devices with external power supply
1. NOTICE! Connected devices with external power supply can feed back current into the 5 V power supply of the USB interface and thus damage the
R&S SMCV100B.
Ensure that there is no connection between the positive pole of the power
supply and the +5 V power pin of the USB interface (VBUS).
2. Connect the USB storage device to any of the USB connectors.
To connect a keyboard
► Connect the keyboard to any of the USB connectors.
When connected, the R&S SMCV100B detects the keyboard automatically. A
detected keyboard has the default layout English – US.
22Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
To connect a mouse
► Connect the mouse to any of the USB connectors.
When connected, the R&S SMCV100B detects the mouse automatically.
To connect power sensors
You can connect power sensors of the R&S NRP families to any of the USB connectors.
See chapter "Using Power Sensors" in the user manual.
Preparing for use
Connecting to RF 50 Ω
4.10Connecting to RF 50 Ω
The connector is located on the front panel.
To prepare for connecting to RF 50 Ω
1. NOTICE! Damaged or not clean connections can lead to RF insertion loss
and mismatch, and even premature wear of the connectors.
Before connecting to the port, inspect the RF connector visually to check that
it is clean, undamaged and mechanically compatible.
See the application note 1MA99 for information on how to handle and maintain the RF port, to minimize measurement deviations and ensure its longevity.
2. NOTICE! Risk of instrument damage. Excessive reverse power or DC voltage
at the RF 50 Ω connector can damage the instrument.
Make sure that signal power and DC limits as given in the data sheet.
3. If the R&S SMCV100B is switched on, deactivate the RF output, before connecting an RF cable to the RF 50 Ω connector.
In the block diagram, select the block "RF" > "RF Level" > "RF ON > Off".
4. Use a high-quality RF cable that matches the RF connector type.
See "Cable selection and electromagnetic interference (EMI)"on page 19.
To connect to non-screwable connectors (BNC)
► To connect the RF cable with the RF 50 Ω connector, proceed as follows:
a) Carefully align the connector of the cable and the RF 50 Ω connector
along a common axis.
23Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
Connecting to Dig. IQ HS x
b) Mate the connectors along the common axis until the male pin of the con-
nector of the cable engages with the female socket of the RF 50 Ω connector.
The connector types listed in this table represent the common connectors provided by Rohde & Schwarz. It is considered as general information and therefore
can contain connector types that do not apply to your instrument.
See "RF 50 Ω"on page 33.
To prevent RF output switch-off
► NOTICE! If you set a too high output level without a load connected to the
instrument, the reverse power can exceed a limit forcing the R&S SMCV100B
to switch off the RF output.
Connect a load with sufficient return loss as given in the data sheet.
Preparing for use
4.11Connecting to Ref In/Ref Out
The connector is located on the rear panel.
To connect to Ref In/Ref Out (reference < 1 GHz)
For connection, the R&S SMCV100B provides BNC connectors.
► Follow the instructions in "To connect to non-screwable connectors (BNC)"
on page 23.
4.12Connecting to Dig. IQ HS x
The Dig. IQ HS x connector comprises a QSFP+ (Quad Small Form-factor Pluggable) socket, that has two components: a QSFP+ cage and a QSFP+ connector.
The QSFP+ cable is equipped with the QSFP+ plug.
24Getting Started 1432.7046.02 ─ 04
R&S®SMCV100B
3
1
2
1 = QSFP+ plug
2 = QSFP+ cage
3 = QSFP+ connector
The connector is located on the rear panel.
Preparing for use
Connecting to Dig. IQ HS x
To connect to Dig. IQ HS x interface
1. For connection, use the QSFP+ cable R&S DIGIQ-HS.
See "Cable selection and electromagnetic interference (EMI)"on page 19.
2. Hold the QSFP+ plug of the cable by its panes.
3. Turn the QSFP+ cable, so that the release tab shows upwards.
4. Insert and push the QSFP+ plug into the QSFP+ cage.
To disconnect from Dig. IQ HS x interface
1. NOTICE! If you pull the cable, you can damage the cable and the Dig. IQ HS
x connector.
Pull the release tab.
2. Pull the QSFP+ plug out of the QSFP+ cage.
See also chapters "Digital Baseband Input Settings" and "I/Q Digital Output Settings" in the user manual.
25Getting Started 1432.7046.02 ─ 04
Loading...
+ 56 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.