The R&S ScopeSuite software is used with R&S RTP oscilloscopes. It can be installed
on a test computer or directly on the oscilloscope. For system requirements, refer to
the Release Notes.
The R&S ScopeSuite main panel has several areas:
●
"Settings": connection settings to oscilloscope and other instruments also default
report settings
●
"Compliance Tests": selection of the compliance test
●
"Demo": accesses demo test cases that can be used for trying out the software
without having a connection to an oscilloscope
●
"Help": opens the help file, containing information about the R&S ScopeSuite configuration
●
"About": gives information about the R&SScopeSuite software
●
"Tile View": allows a personalization of the compliance test selection
You can configure which tests are visible in the compliance test section and which
are hidden, so that only the ones you use are displayed.
► To hide a test from the "Compliance Tests" view, do one of the following:
5User Manual 1179.3196.02 ─ 01
R&S®RTP-K110
R&S ScopeSuite Overview
a) Right-click on the compliance test you want to hide.
The icon of the test changes, see Figure 1-1. Now with a left click you can hide
the test.
Figure 1-1: Unpin icon
b) Click on "Title View" to show a list of the available test cases. By clicking a test
case in the show list, you can pin/unpin it from the main panel.
6User Manual 1179.3196.02 ─ 01
R&S®RTP-K110
2Preparing the Measurements
2.1Test Equipment
Preparing the Measurements
Installing Software and License
For HDMI compliance tests, the following test equipment is needed:
●
R&S RTP with 4 channels and minimum 8 GHz bandwidth
●
R&S RTP-K101 HDMI compliance test option (required option, installed on the
R&S RTP)
●
2 modular probes, R&S ZM160 with 9 GHz bandwidth.
●
2 modular probe tips R&S RT-ZMA40
●
HDMI Termination Module and a HDMI TPA adapter
●
EDID Emulator
●
The free-of-charge R&S ScopeSuite software, which can be installed on a computer or directly on the R&S RTP.
2.2Installing Software and License
The preparation steps are performed only once for each computer and instrument that
are used for testing.
Uninstall older versions of the R&S ScopeSuite
If an older version of the R&S ScopeSuite is installed, make sure to uninstall the old
version before you install the new one. You can find the version number of the current
installation in "Help" menu > "About". To uninstall the R&S ScopeSuite, use the Windows " Control Panel" > "Programs".
For best operation results, we recommend that the installed firmware versions of the
R&S ScopeSuite and the oscilloscope are the same.
To install the R&S ScopeSuite
1. Download the latest R&S ScopeSuite software from the "Software" section on the
Rohde & Schwarz R&S RTP website:
For system requirements, refer to the Release Notes.
7User Manual 1179.3196.02 ─ 01
R&S®RTP-K110
Preparing the Measurements
To install the license key on the R&S RTP
► When you got the license key of the compliance test option, enable it on the oscil-
loscope using [Setup] > "SW Options".
For a detailed description, refer to the R&S RTP user manual, chapter "Installing
Options", or to the online help on the instrument.
2.3Setting Up the Network
If the R&S ScopeSuite software runs on a test computer, the computer and the testing
oscilloscope require a LAN connection.
There are two ways of connection:
●
LAN (local area network): It is recommended that you connect to a LAN with DHCP
server. This server uses the Dynamic Host Configuration Protocol (DHCP) to
assign all address information automatically.
If no DHCP server is available, or if the Tabor WX2182B or WX2182C is used for
automatic testing, assign fixed IP addresses to all devices.
●
Direct connection of the instruments and the computer or connection to a switch
using LAN cables: Assign fixed IP addresses to the computer and the instruments
and reboot all devices.
Starting the R&S
ScopeSuite
To set up and test the LAN connection
1. Connect the computer and the instruments to the same LAN.
2. Start all devices.
3. If no DHCP server is available, assign fixed IP addresses to all devices.
4. Ping the instruments to make sure that the connection is established.
5. If VISA is installed, check if VISA can access the instruments.
a) Start VISA on the test computer.
b) Validate the VISA address string of each device.
See also:
●
Chapter 2.5, "Connecting the R&SRTP", on page 9
2.4Starting the R&SScopeSuite
To start the R&S ScopeSuite on the test computer or on the oscilloscope:
► Double-click the R&S ScopeSuite program icon.
8User Manual 1179.3196.02 ─ 01
R&S®RTP-K110
Preparing the Measurements
To start the R&S ScopeSuite on the instrument, in the R&S RTP firmware:
► In the "Apps" dialog, open the "Compliance" tab.
2.5Connecting the R&S RTP
If the R&S ScopeSuite is installed directly on the instrument, the software detects the
R&S RTP firmware automatically, and the "Oscilloscope" button is not available in the
R&S ScopeSuite.
If the R&S ScopeSuite software runs on a test computer, the computer and the testing
oscilloscope require a LAN connection, see Chapter 2.3, "Setting Up the Network",
on page 8. The R&S ScopeSuite software needs the IP address of the oscilloscope to
establish connection.
1. Start the R&S RTP.
2. Start the R&S ScopeSuite software.
3. Click "Settings" > "Oscilloscope".
Connecting the R&S
RTP
4. Enter the IP address of the oscilloscope.
To obtain the IP address: press the Rohde & Schwarz logo at the top-right corner
of the oscilloscope's display.
5. Click "Get Instrument Information".
The computer connects with the instrument and gets the instrument data.
9User Manual 1179.3196.02 ─ 01
R&S®RTP-K110
Preparing the Measurements
Report Configuration
If the connection fails, an error message is shown.
2.6Report Configuration
In the "Report Configuration" menu, you can select the format of the report and the
details to be included in the report. You can also select an icon that is displayed in the
upper left corner of the report.
Also, you can enter common information on the test that is written in the "General Information" section of the test report.
10User Manual 1179.3196.02 ─ 01
R&S®RTP-K110
Preparing the Measurements
Report Configuration
11User Manual 1179.3196.02 ─ 01
R&S®RTP-K110
3Performing Tests
3.1Starting a Test Session
Performing Tests
Starting a Test Session
After you open a compliance test, the "Session Selection" dialog appears. In this dialog, you can create new sessions, open or view existing report.
The following functions are available for handling test sessions:
FunctionDescription
"Add"Adds a new session
"Open"Opens the selected session
"Remove"Removes the selected session
"Rename"Changes the "Session Name"
"Comment"Adds a comment
"Show report"Generates a report for the selected session
To add a test session
1. In the R&S ScopeSuite window, select the compliance test.
2. In the "Session Selection" dialog press "Add".
3. If necessary change the "Session Name"
12User Manual 1179.3196.02 ─ 01