Rohde&Schwarz R&S®RTP Getting Started Getting started

®
R&S
RTP High-Performance Oscilloscope Getting Started
(B3ÎÜ2)
1803647802 Version 01
This manual describes the following R&S®RTP models with firmware version 5.15 and higher:
R&S®RTP044B (1803.7000K04)
R&S®RTP064B (1803.7000K06)
R&S®RTP084B (1803.7000K08)
R&S®RTP134B (1803.7000K13)
R&S®RTP164B (1803.7000K16)
© 2022 Rohde & Schwarz GmbH & Co. KG
Muehldorfstr. 15, 81671 Muenchen, Germany
Phone: +49 89 41 29 - 0
Email: info@rohde-schwarz.com
Internet: www.rohde-schwarz.com
Subject to change – data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
1803.6478.02 | Version 01 | R&S®RTP
Throughout this manual, products from Rohde & Schwarz are indicated without the ® symbol, e.g. R&S®RTP is indicated as R&S RTP.
R&S®RTP

Contents

1 Safety and regulatory information....................................... 5
1.1 Safety instructions................................................................................5
1.2 Labels on the product.........................................................................11
1.3 Warning messages in the documentation........................................12
1.4 Where to find key documents on Rohde & Schwarz....................... 12
1.5 Korea certification class A.................................................................13
2 Key features......................................................................... 14
3 Documentation overview.................................................... 15
Contents
3.1 Manuals and instrument help............................................................ 15
3.2 Data sheet and brochure....................................................................17
3.3 Release notes, open source acknowledgment................................ 17
3.4 Application notes, application cards, videos...................................17
4 Preparing for use................................................................. 18
4.1 Lifting and carrying............................................................................ 18
4.2 Unpacking and checking....................................................................18
4.3 Choosing the operating site.............................................................. 18
4.4 Setting up the product........................................................................19
4.5 Considerations for test setup............................................................ 21
4.6 Connecting to power.......................................................................... 22
4.7 Switching on or off............................................................................. 23
4.8 Connecting external devices............................................................. 24
5 Instrument tour.................................................................... 27
5.1 Front panel.......................................................................................... 27
5.2 Rear panel............................................................................................30
3Getting Started 1803.6478.02 ─ 01
R&S®RTP
5.3 Keys and controls...............................................................................33
Contents
6 Operating the instrument....................................................41
6.1 Means of manual interaction............................................................. 41
6.2 Touchscreen display...........................................................................42
6.3 Applications........................................................................................ 49
6.4 Working with waveforms....................................................................50
6.5 Rohde & Schwarz SmartGrid............................................................. 53
6.6 Toolbar................................................................................................. 54
6.7 Displaying results............................................................................... 63
6.8 Using dialogs...................................................................................... 65
6.9 Entering data....................................................................................... 66
6.10 Instrument information and notifications.........................................68
6.11 Getting help......................................................................................... 69
7 Setting up the instrument................................................... 73
7.1 Performing a self-alignment.............................................................. 73
7.2 Setting the display language............................................................. 74
8 Contacting customer support............................................ 75
Index..................................................................................... 76
4Getting Started 1803.6478.02 ─ 01
R&S®RTP
Safety and regulatory information
Safety instructions

1 Safety and regulatory information

The product documentation helps you to use the product safely and efficiently. Follow the instructions provided here and in the Chapter 1.1, "Safety instructions", on page 5.
Intended use
The R&S RTP oscilloscope is designed for measurements on circuits that are only indirectly connected to the mains or not connected at all. It is not rated for any measurement category.
The product is intended for the development, production and verification of elec­tronic components and devices in industrial, administrative, and laboratory envi­ronments. Use the product only for its designated purpose. Observe the operating conditions and performance limits stated in the data sheet.
Where do I find safety information?
Safety information is part of the product documentation. It warns you of potential dangers and gives instructions on how to prevent personal injury or damage caused by dangerous situations. Safety information is provided as follows:
In Chapter 1.1, "Safety instructions", on page 5. The same information is provided in many languages as printed "Safety Instructions". The printed "Safety Instructions" are delivered with the product.
Throughout the documentation, safety instructions are provided when you need to take care during setup or operation.

1.1 Safety instructions

Products from the Rohde & Schwarz group of companies are manufactured according to the highest technical standards. To use the products safely, follow the instructions provided here and in the product documentation. Keep the prod­uct documentation nearby and offer it to other users.
Use the product only for its intended use and within its performance limits. Inten­ded use and limits are described in the product documentation such as the data sheet, manuals and the printed "Safety Instructions". If you are unsure about the appropriate use, contact Rohde & Schwarz customer service.
5Getting Started 1803.6478.02 ─ 01
R&S®RTP
Using the product requires specialists or specially trained personnel. These users also need sound knowledge of at least one of the languages in which the user interfaces and the product documentation are available.
Never open the casing of the product. Only service personnel authorized by Rohde & Schwarz are allowed to repair the product. If any part of the product is damaged or broken, stop using the product. Contact Rohde & Schwarz customer service at http://www.customersupport.rohde-schwarz.com.
In these safety instructions, the term "product" covers instruments (oscillo­scopes), probes and their accessories.
Lifting and carrying the instrument
Check the data sheet for the maximum weight of the instrument. A single person can only carry a maximum of 18 kg safely depending on age, gender and physical condition. If your instrument is heavier than 18 kg, do not move or carry it by your­self.
Safety and regulatory information
Safety instructions
Use the instrument handles to move or carry the instrument. Do not use the mounted accessories instead of the handles. Accessories are not designed to carry the weight of the instrument.
To move the instrument safely, you can use lifting or transporting equipment such as lift trucks and forklifts. Follow the instructions provided by the equipment man­ufacturer.
Choosing the operating site
Only use the product indoors. The product casing is not waterproof. Water that enters can electrically connect the casing with live parts, which can lead to elec­tric shock, serious personal injury or death if you touch the casing. If Rohde & Schwarz provides accessories designed for your product, e.g. a carrying bag, you can use the product outdoors.
You can operate the product up to the altitude specified in the data sheet. The lowest specified altitude for a product of the measurement setup defines the alti­tude for the complete setup.
The product is suitable for pollution degree 2 environments where nonconductive contamination can occur. For more information on environmental conditions such as ambient temperature and humidity, see the data sheet.
6Getting Started 1803.6478.02 ─ 01
R&S®RTP
Setting up the product
Always place the product on a stable, flat and level surface with the bottom of the product facing down. If the product is designed for different positions, secure the product so that it cannot fall over.
If the product has foldable feet, always fold the feet completely in or out to ensure stability. The feet can collapse if they are not folded out completely or if the prod­uct is moved without lifting it. The foldable feet are designed to carry the weight of the product, but not an extra load.
If stacking is possible, keep in mind that a stack of products can fall over and cause injury.
If you mount products in a rack, ensure that the rack has sufficient load capacity and stability. Observe the specifications of the rack manufacturer. Always install the products from the bottom shelf to the top shelf so that the rack stands securely. Secure the product so that it cannot fall off the rack.
Safety and regulatory information
Safety instructions
Connecting to power and grounding
The mains power supply input of the instrument complies with overvoltage cate­gory II. It has to be connected to a fixed installation used to supply energy-con­suming equipment such as household appliances and similar loads. Be aware that electrically powered products have risks, such as electric shock, fire, per­sonal injury or even death.
Take the following measures for your safety:
Do not use an isolating transformer to connect the instrument to the mains power supply.
Before switching on the product, ensure that the voltage and frequency indica­ted on the product match the available power source. If the power adapter does not adjust automatically, set the correct value and check the rating of the fuse.
Only use the power cable delivered with the product. It complies with country­specific safety requirements. Only insert the plug into an outlet with protective conductor terminal.
If a product has an exchangeable fuse, its type and characteristics are indica­ted next to the fuse holder. Before changing the fuse, switch off the instrument and disconnect it from the power source. How to change the fuse is described in the product documentation.
7Getting Started 1803.6478.02 ─ 01
R&S®RTP
Only use intact cables and route them carefully so that they cannot be dam­aged. Check the power cables regularly to ensure that they are undamaged. Also ensure that nobody can trip over loose cables.
If the product needs an external power supply, use the power supply that is delivered with the product or that is recommended in the product documenta­tion or a power supply that conforms to the country-specific regulations.
Ensure that you can disconnect the product from the power source at any time. Pull the power plug to disconnect the product. The power plug must be easily accessible. If the product is integrated into a system that does not meet these requirements, provide an easily accessible circuit breaker at the system level.
Performing measurements
Take the following measures for your safety:
To ascertain voltage-free state, use an appropriate voltage tester. Any mea­surement setup including an oscilloscope is not suitable for this purpose.
Safety and regulatory information
Safety instructions
The maximum input voltage on channel inputs and the external trigger input must not exceed the value specified in the data sheet.
Observe all voltage and current ratings of the instrument, the probes, and the accessories. Limits and ratings are marked on the products and listed in the data sheets. Consider that the rated voltage depends on the frequency. The voltage limita­tion curves or values are provided in the data sheet. Do not exceed the maxi­mum measurement voltage from the probe tip to the probe reference lead.
Never cause any short circuits when measuring sources with high output cur­rents.
Use only probes and accessories that comply with the measurement category (CAT) of your measurement task. The measurement category of the products is defined in the data sheet. If you use other than Rohde & Schwarz accesso­ries, make sure that they are suitable for the instrument and the measurement task.
Set the correct attenuation factor on the instrument according to the probe being used. Otherwise, the measurement results do not reflect the actual volt­age level, and you might misjudge the actual risk.
When working with high voltages and current probes, observe the additional operating conditions specified in this safety instructions.
The probe pins are extremely pointed and can easily penetrate clothes and the skin. Handle the probe pins with great care. To exchange a probe pin, use
8Getting Started 1803.6478.02 ─ 01
R&S®RTP
tweezers or pliers to avoid injuries. When transporting the accessories, always use the box supplied with the probe.
Prevent the probe from receiving mechanical shock. Avoid putting excessive strain on the probe cable or exposing it to sharp bends. Touching a broken cable during measurements can cause injuries.
Set up all probe connections to the instrument before applying power.
Working with hazardous voltages
Voltages higher than 30 V RMS, or 42 V peak, or 60 V DC are regarded as haz­ardous contact voltages. Direct contact with them can cause serious injuries.
Make sure that only electrically skilled persons use the products for measure­ments on hazardous contact voltages. These working conditions require special education and experience to perceive risks and to avoid hazards which electricity can create.
Safety and regulatory information
Safety instructions
When working with hazardous contact voltages, use protective measures to pre­clude direct contact with the measurement setup:
Do not touch exposed connections and components when power is applied.
Switch off the test circuit while connecting and disconnecting probe leads.
Use only insulated voltage probes, test leads and adapters.
Make sure that the input leads fulfill the safety requirements for your measure­ment. The delivered input leads might have a jacket wear indicator that indicates a worn jacket by different jacket color. In this case, do not use the input lead. Replace it with a new one.
Do not use 4 mm banana plugs without protection against contact.
Working with current probes
When working with current probes, you can measure high-frequency currents or currents that contain high-frequency components.
Switch off the test circuit while connecting the probe.
Do not attach the clamp to bare unisolated conductors. To avoid injury from a short circuit, measure at a location on an insulated wire where the insulation is sufficient for the circuit voltage.
Connect the probe only to the secondary side of a breaker. With this measure, you avoid injury, if a short circuit occurs.
9Getting Started 1803.6478.02 ─ 01
R&S®RTP
The following effects can cause burns and fire or damage to the measurement site:
Eddy current loss can cause heating of the sensor head.
Dielectric heating can cause heating of cord insulation and other materials.
Measurement categories
IEC 61010-2-030 defines measurement categories that rate instruments on their ability to resist short transient overvoltages that occur in addition to the working voltage. Use the measurement setup only in electrical environments for which they are rated.
0 - Instruments without rated measurement category For measurements performed on circuits not directly connected to mains, for example, electronics, circuits powered by batteries, and specially protected secondary circuits. This measurement category is also known as CAT I.
Safety and regulatory information
Safety instructions
CAT II: For measurements performed on circuits directly connected to the low-voltage installation by a standard socket outlet, for example, household appliances and portable tools.
CAT III: For measurements performed in the building installation, such as junction boxes, circuit breakers, distribution boards, and equipment with permanent connection to the fixed installation.
CAT IV: For measurements performed at the source of the low-voltage installation, such as electricity meters and primary overcurrent protection devices.
10Getting Started 1803.6478.02 ─ 01
R&S®RTP
Safety and regulatory information
Labels on the product
Cleaning the product
Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that the casing is not waterproof. Do not use liquid cleaning agents.
Meaning of safety labels
Safety labels on the product warn against potential hazards.
Potential hazard Read the product documentation to avoid personal injury or product damage.
Heavy product Be careful when lifting, moving or carrying the product. Carrying the product requires
at least two people or transport equipment.
Electrical hazard Indicates live parts. Risk of electric shock, fire, personal injury or even death.
Protective conductor terminal Connect this terminal to a grounded external conductor or to protective ground. This
protects you against electric shock should an electric problem occur.

1.2 Labels on the product

Labels on the casing inform about:
Personal safety, see "Meaning of safety labels" on page 11
Product and environment safety, see Table 1-1
Identification of the product
Table 1-1: Labels regarding product and environment safety
Chassis grounding terminal
Take care when handling electrostatic sensitive devices.
Labeling in line with EN 50419 for disposal of electrical and electronic equipment after the product has come to the end of its service life.
For more information, see the product user manual, chapter "Disposal".
11Getting Started 1803.6478.02 ─ 01
R&S®RTP

Where to find key documents on Rohde & Schwarz

Safety and regulatory information

1.3 Warning messages in the documentation

A warning message points out a risk or danger that you need to be aware of. The signal word indicates the severity of the safety hazard and how likely it will occur if you do not follow the safety precautions.
WARNING
Potentially hazardous situation. Could result in death or serious injury if not avoi­ded.
CAUTION
Potentially hazardous situation. Could result in minor or moderate injury if not avoided.
NOTICE
Potential risks of damage. Could result in damage to the supported product or to other property.
1.4 Where to find key documents on
Rohde & Schwarz
Certificates issued to Rohde & Schwarz that are relevant for your country are pro­vided at www.rohde-schwarz.com/key-documents, e.g. concerning:
Quality management
Environmental management
Information security management
Accreditations
12Getting Started 1803.6478.02 ─ 01
R&S®RTP
Safety and regulatory information
Korea certification class A

1.5 Korea certification class A

이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하 시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.
13Getting Started 1803.6478.02 ─ 01
R&S®RTP
Key features

2 Key features

The R&S RTP high-performance oscilloscopes combine superior signal integrity with fastest acquisition rate. It combines multiple instrument capabilities for time­correlated debugging in one box. Outstanding key features are:
Real-time signal integrity
Superior frontend performance
Real-time de-embedding and advanced triggering
Hardware accelerated processing for faster results
Comprehensive analysis tools, for example, powerful protocol analysis, jitter analysis functions, automatic compliance tests, spectrograms, and precise and wideband RF analysis
Multi-instrument capability
Time-correlated analysis of different signal types
Integrated arbitrary waveform and pattern generator that can be used, for example, for protocol-based programming
Easy-to-use serial protocol analysis for various protocols used in embedded design, mobile communications and more
General-purpose mixed signal option
Multi-channel power consumption analysis with up to 8 additional voltage and 8 additional current measurement channels and very high dynamic range
16 GHz pulse source
Compact and configurable
Most compact high-end instrument platform
Highest configuration flexibility
Advanced user interface
For a detailed specification, refer to the data sheet.
14Getting Started 1803.6478.02 ─ 01
R&S®RTP
Documentation overview
Manuals and instrument help

3 Documentation overview

This section provides an overview of the R&S RTP user documentation.

3.1 Manuals and instrument help

You find the manuals on the product page at:
www.rohde-schwarz.com/manual/rtp
Getting started manual
Introduces the R&S RTP and describes how to set up and start working with the instrument, and describes basic operations. A printed English version is included in the delivery. Editions in other languages are available on the product website.
Instrument help
The help offers quick, context-sensitive access to the complete information for the firmware basic functionality and applications.
User manual (Instrument)
Describes all instrument functions in detail. It also provides an introduction to remote control, a complete description of the remote control commands with pro­gramming examples, and information on maintenance and instrument interfaces. Includes the contents of the getting started manual.
The online version of the user manual provides the complete contents for immedi­ate display on the internet.
Manuals for compliance test options
For compliance test options, extra test procedure manuals are available. Test fix­tures are described in printed manuals, which are delivered with the fixture.
The following test procedure manuals are available:
USB 2.0/3.2 Compliance Test Procedures
Ethernet Compliance Tests Procedures
MIPI D-PHY Compliance Tests Procedures
15Getting Started 1803.6478.02 ─ 01
R&S®RTP
eMMC Compliance Tests Procedures
PCIe Compliance Tests Procedures
DDR3 Compliance Tests Procedures
DDR4 Compliance Tests Procedures
HDMI Tests Procedures
ScopeSuite Automation
The following test fixture manuals are available:
R&S RT-ZF1 USB 2.0 Compliance Test Fixture Set
R&S RT-ZF2 Ethernet Compliance Test Fixture Set
R&S RT-ZF3 Frequency Converter Board (100BASE-T1)
R&S RT-ZF4 10BASE-Te Test Fixture
R&S RT-ZF5 Ethernet Probing Fixture
R&S RT-ZF6 Frequency Converter Board (1000BASE-T1)
Documentation overview
Manuals and instrument help
R&S RT-ZF7 Automotive Ethernet T&D Fixture
R&S RT-ZF7A and R&S RT-ZF7P SMA Adaptors
R&S RT-ZF8 Automotive Ethernet Compliance Test Fixture
Safety instructions
Provides safety information in many languages. The printed document is deliv­ered with the product.
Instrument security procedures manual
Deals with security issues when working with the R&S RTP in secure areas.
Service Manual
Describes the performance test for checking the rated specifications, module replacement, firmware update, troubleshooting and fault elimination, and contains mechanical drawings and spare part lists. The service manual is available for reg­istered users on the global Rohde & Schwarz information system (GLORIS,
https://gloris.rohde-schwarz.com).
16Getting Started 1803.6478.02 ─ 01
R&S®RTP
Application notes, application cards, videos
Documentation overview

3.2 Data sheet and brochure

The data sheet contains the technical specifications of the R&S RTP. It also lists the options with their order numbers and optional accessories. The brochure pro­vides an overview of the instrument and deals with the specific characteristics.
See www.rohde-schwarz.com/brochure-datasheet/rtp

3.3 Release notes, open source acknowledgment

The release notes list new features, improvements and known issues of the cur­rent firmware version, and describe the firmware installation. The open source acknowledgment document provides verbatim license texts of the used open source software. It can also be read directly on the instrument.
See www.rohde-schwarz.com/firmware/rtp.

3.4 Application notes, application cards, videos

These documents deal with special applications or background information on particular topics.
Application notes
Media center
Application videos
17Getting Started 1803.6478.02 ─ 01
R&S®RTP
Choosing the operating site
Preparing for use

4 Preparing for use

Here, you can find basic information about setting up the instrument for the first time or when changing the operating site.

4.1 Lifting and carrying

See: "Lifting and carrying the instrument" on page 6.

4.2 Unpacking and checking

1. Unpack the product carefully.
2. Retain the original packing material. Use it when transporting or shipping the product later.
3. Using the delivery notes, check the equipment for completeness.
4. Check the equipment for damage.
If the delivery is incomplete or equipment is damaged, contact Rohde & Schwarz.

4.3 Choosing the operating site

Specific operating conditions ensure proper operation and avoid damage to the product and connected devices. For information on environmental conditions such as ambient temperature and humidity, see the data sheet.
See also "Choosing the operating site" on page 6.
18Getting Started 1803.6478.02 ─ 01
R&S®RTP
Electromagnetic compatibility classes
The electromagnetic compatibility (EMC) class indicates where you can operate the product. The EMC class of the product is given in the data sheet.
Class B equipment is suitable for use in:
Residential environments
Environments that are directly connected to a low-voltage supply network
that supplies residential buildings
Class A equipment is intended for use in industrial environments. It can cause radio disturbances in residential environments due to possible conducted and radiated disturbances. It is therefore not suitable for class B environments. If class A equipment causes radio disturbances, take appropriate measures to eliminate them.
Preparing for use
Setting up the product

4.4 Setting up the product

When setting up the instrument, follow the safety instructions:
"Setting up the product" on page 7
"Intended use" on page 5

4.4.1 Placing the product on a bench top

For standalone operation, place the instrument on a horizontal bench with even, flat surface. The instrument can be used in horizontal position, standing on its feet, or with the support feet on the bottom extended.
To place the product on a bench top
1. Place the product on a stable, flat and level surface. Ensure that the surface can support the weight of the product. For information on the weight, see the data sheet.
2. CAUTION! Foldable feet can collapse. See "Setting up the product" on page 7.
Always fold the feet completely in or out. With folded-out feet, do not place anything on top or underneath.
19Getting Started 1803.6478.02 ─ 01
R&S®RTP
Preparing for use
Setting up the product
3. CAUTION! A stack of products can fall over and cause injury. Never stack more than two products. Otherwise, mount them in a rack.
Stack as follows:
All products must have the same dimensions (width and length).
Do not exceed a total load of 25 kg placed on the product at the bottom of
the stack.
Fold in all foldable feet completely.
Left = Stacked correctly Right = Stacked incorrectly, too many products
4. NOTICE! Overheating can damage the product.
Prevent overheating as follows:
Keep a minimum distance of 10 cm between the fan openings of the prod-
uct and any object in the vicinity.
Do not place the product next to heat-generating equipment such as radia-
tors or other products.

4.4.2 Mounting the product in a rack

The instrument can be installed in a rack using a rack adapter kit. The order num­ber is given in the data sheet. The installation instructions are part of the adapter kit.
To prepare the rack
1. Observe the requirements and instructions in "Setting up the product" on page 7.
2. NOTICE! Insufficient airflow can cause overheating and damage the product.
20Getting Started 1803.6478.02 ─ 01
R&S®RTP
Considerations for test setup
Design and implement an efficient ventilation concept for the rack.
To mount the R&S RTP in a rack
1. Use an adapter kit that fits the dimensions of the R&S RTP to prepare the instrument for rack mounting. For information on the dimensions, see data sheet.
a) Order the rack adapter kit designed for the R&S RTP. For the order num-
ber, see data sheet.
b) Mount the adapter kit. Follow the assembly instructions provided with the
adapter kit.
2. Push the product onto the shelf until the rack brackets fit closely to the rack.
3. Tighten all screws at the rack brackets with a tightening torque of 1.2 Nm to secure the product at the rack.
Preparing for use
To unmount the product from a rack
1. Loosen the screws at the rack brackets.
2. Remove the product from the rack.
3. If placing the product on a bench top again, unmount the adapter kit from the product. Follow the instructions provided with the adapter kit.

4.5 Considerations for test setup

Observe safety instructions, see "Performing measurements" on page 8.
Cable selection and electromagnetic interference (EMI)
Electromagnetic interference (EMI) can affect the measurement results.
To suppress electromagnetic radiation during operation:
Use high-quality shielded cables, for example, double-shielded RF and LAN cables.
Always terminate open cable ends.
Ensure that connected external devices comply with EMC regulations.
21Getting Started 1803.6478.02 ─ 01
R&S®RTP
Signal input and output levels
Information on signal levels is provided in the data sheet. Keep the signal levels within the specified ranges to avoid damage to the product and connected devi­ces.
Preventing electrostatic discharge (ESD)
Electrostatic discharge is most likely to occur when you connect or disconnect a DUT.
NOTICE! Electrostatic discharge can damage the electronic components of
the product and the device under test (DUT).
Ground yourself to prevent electrostatic discharge damage:
a) Use a wrist strap and cord to connect yourself to ground. b) Use a conductive floor mat and heel strap combination.
Preparing for use
Connecting to power
During operation, if the firmware observes a serious unexpected disturbance (e.g. due to ESD), it resets some hardware components and initiates a new alignment to ensure proper instrument functioning. Then it restores the user settings to the state before the disturbance.

4.6 Connecting to power

For safety information, see "Connecting to power and grounding" on page 7.
The R&S RTP can be used with different AC power voltages and adapts itself automatically to it.
The instrument has a C20 connector. A list of appropriate power cables is given in the user manual. Refer to the data sheet for the requirements of voltage and fre­quency.
The nominal ranges are:
100 V to 240 V AC at 50 Hz to 60 Hz, and 100 V to 130 V at 400 Hz, with maximal 10% voltage fluctuation on line
max. 13 A to 4.7 A
1. Plug the AC power cable into the AC power connector on the rear panel of the product. Only use the AC power cable delivered with the product.
22Getting Started 1803.6478.02 ─ 01
R&S®RTP
Preparing for use
Switching on or off
2. Plug the AC power cable into a power outlet with ground contact.
The required ratings are listed next to the AC power connector and in the data sheet.

4.7 Switching on or off

The instrument is switched on or off with the power switch and the [Power] key. The [Power] key is located in the bottom left corner of the front panel. The power switch is located at the rear panel of the instrument.
Table 4-1: Overview of power states
Status LED Power switch
Off
Standby
Ready
(unlighted)
orange
green
[0] (off)
[I] (on)
[I] (on)
To switch on the product
The product is off but connected to power.
1. Set the switch on the power supply to position [I].
The power key on the front panel lights up.
2. Press the [Power] key on the front panel.
The instrument performs a system check, boots the operating system, and then starts the R&S RTP firmware. The [Power] key turns green and the illuminated keys on the front panel light up. If the previous session was terminated regularly, the oscilloscope uses the last settings.
Before you start measurements, be sure to comply with the warm-up phase specified in the data sheet.
To shut down the product
The product is in the ready state.
► Press the [Power] key.
23Getting Started 1803.6478.02 ─ 01
R&S®RTP
Connecting external devices
All current settings are saved, and the software shuts down. The [Power] key turns orange. The standby power supplies only the power switch circuits.
The "Exit" icon in the "Menu" shuts down only the firmware application. To shut down the instrument completely, use the [Power] key.
To disconnect from power
The product is in the standby state.
1. NOTICE! Risk of data loss. If you disconnect the product from power when it is in the ready state, you can lose settings and data. Shut it down first.
Set the switch on the power supply to position [0].
The LED of the [Power] key is switched off.
2. Disconnect the product from the power source.
Preparing for use

4.8 Connecting external devices

The following interfaces for external devices are provided:
USB connectors at the front and rear panel of the instrument
Monitor connectors HDMI and DisplayPort at the rear panel of the instrument

4.8.1 Connecting USB devices

You can connect USB flash drives to save screenshots and measurement results, and keyboard and/or mouse to simplify the operation and the entry of data. You can connect or disconnect all USB devices during operation of the instrument. The number of USB connectors can be increased by using USB hubs.
USB devices are plug&play, the operating system automatically uses the suitable device driver. If the operating system does not find a suitable driver, it prompts you to specify a directory that contains the driver software. If the driver software is on a storage media, connect the appropriate drive to the instrument before pro­ceeding. If the instrument is integrated in a network, you can also install driver data stored in a network directory.
24Getting Started 1803.6478.02 ─ 01
Loading...
+ 55 hidden pages