Worldwide, the two frequency bands 5.25 GHz to 5.35 GHz and
5.47 GHz to 5.725 GHz are used by various radar systems. In addition, they are allocated to unlicensed WLAN devices. A requirement arising from this frequency band reuse
is a method called Dynamic Frequency Selection (DFS).
A system that requires DFS must be capable to avoid interfering with radar systems.
This is achieved by various methods:
●
Verify that the channel is free of any radar signals before using it.
●
Continuous monitoring for radar signals once a channel is in use. The channel
needs to be vacated if a radar signal is detected.
●
Blacklisting channels where a radar signal was detected.
●
Using channels equally (Uniform Loading).
●
Transmit only the required amount of power (Transmit Power Control).
Welcome to the R&SPulse Sequencer (DFS)
Pulse Sequencer (DFS) key features
R&S
Most radar systems in these bands are used by the military and their actual signatures
are confidential. The representative test patterns therefore contain random variations.
The specifications require that WLAN devices not only detect a specific pattern but
also respond to a wider variety of signals.
Different standards documents exist worldwide that define requirements and test patterns. An overview is provided in Appendix, "DFS Standards and References".
Installation
You can find detailed installation instructions in the delivery of the option or in Chap-
ter 2.2, "Installing the software", on page 10.
1.1R&S Pulse Sequencer (DFS) key features
The R&S Pulse Sequencer (DFS) software is a standalone, PC-based application that
generates Dynamic Frequency Selection (DFS) pulse patterns according to FCC,
ETSI, and MIC standards. This software is available for free download on the R&S
website.
Waveforms can be played by the following instruments:
●
R&S SMW
●
R&S SMBV
●
R&S SMBV100B
●
R&S SMM
●
R&S SMU
●
R&S SMJ
●
R&S SGT
5User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
The processing of the generated waveforms requires software option R&S SMW/
SMBV/SMU/SMJ/SGT-K350 installed on the instrument.
Key features:
●
Supported Standards for Europe, the US, Japan, Korea and China
●
Generation of all required waveforms and automatic transfer to the signal generator
●
Automatic report generation.
Reports contain all parameters used for the waveform calculation
●
Two report formats: Excel spreadsheets and ASCII text format
1.2Accessing the R&S Pulse Sequencer (DFS)
To open the application
► On your PC, select "Start > All Programs > R&S Pulse Sequencer DFS".
Welcome to the R&S Pulse Sequencer (DFS)
Documentation overview
The software opens and displays the "Repository Manager" or the last used "Workspace".
1.3Documentation overview
This section provides an overview of the R&S Pulse Sequencer (DFS) user documentation. Unless specified otherwise, you find the documents on the software option page
at:
Introduces the R&S Pulse Sequencer (DFS) and describes how to start working with
the software. For description of the graphical user interface, basic operations, and the
remote control commands, see the R&S®Pulse Sequencer user manual.
The contents of the user manuals are available as help in the R&S Pulse Sequencer
(DFS). The help offers quick, context-sensitive access to the complete information.
All user manuals are also available for download or for immediate display on the Internet.
1.3.2Release notes and open-source acknowledgment (OSA)
The release notes list new features, improvements and known issues of the current
firmware version, and describe the firmware installation.
6User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
The open-source acknowledgment document provides verbatim license texts of the
used open-source software.
See www.rohde-schwarz.com/product/SMWK350 > "Downloads" > "Software"
1.3.3Data sheets and brochures
The data sheet contains the technical specifications of the R&S Pulse Sequencer
(DFS). It also lists the options and their order numbers and optional accessories.
The brochure provides an overview of the instrument and deals with the specific characteristics.
See https://www.rohde-schwarz.com/brochure-datasheet/smwk350/
1.3.4Application notes, application cards, white papers, etc.
These documents deal with special applications or background information on particular topics.
Welcome to the R&S Pulse Sequencer (DFS)
Notes on screenshots
1.4Scope of this user manual
The R&S Pulse Sequencer (DFS) is the DFS variant of the R&S®Pulse Sequencer
software that is specially developed for DFS testing.
This user manual describes the functionality that the R&S Pulse Sequencer (DFS) software provides.
Functions that are the same as in the R&S®Pulse Sequencer software are not described here; they are described in its user manual.
Functions of the vector signal generators are also not described here; they are described in the user manual of the corresponding base unit. You find the latest version on
the product page, for example at www.rohde-schwarz.com/product/SMW200A.
1.5Notes on screenshots
When describing the functions of the product, we use sample screenshots. These
screenshots are meant to illustrate as many as possible of the provided functions and
possible interdependencies between parameters. The shown values may not represent
realistic usage scenarios.
The screenshots usually show a fully equipped product, that is: with all options installed. Thus, some functions shown in the screenshots may not be available in your particular product configuration.
7User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
Welcome to the R&S Pulse Sequencer (DFS)
Notes on screenshots
8User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
2Getting started
This section describes the basic steps to be taken when starting up the R&S Pulse
Sequencer (DFS) for the first time.
●Installing the software............................................................................................. 10
●Starting the R&S Pulse Sequencer (DFS) for the first time.....................................12
●Understanding the displayed information................................................................12
●Loading a DFS project file.......................................................................................17
●Getting information and help...................................................................................19
2.1Required options
The R&S Pulse Sequencer (DFS) software is a stand-alone, PC-based application that
creates waveform files. This software is available for free download on the R&S website. Waveforms generated with the software can be played by a subset of instruments,
that must fulfill the minimum requirements listed below.
Getting started
Required options
The following vector signal generators support the FCC 06-96 Type 6 simulated frequency hopping.
R&S SMW200A
R&SSMW200A base unit equipped with:
●
Option baseband generator (R&SSMW-B10)
●
Option frequency (R&SSMW-B106)
●
Option baseband main module, one I/Q path to RF (R&SSMW-B13)
●
Option DFS (R&S SMW-K350)
R&S SMBV100B
R&SSMBV100B base unit equipped with:
●
Option frequency (R&SSMBV-B103/KB106)
●
Option DFS (R&SSMBVB-K350)
R&SSMBV100A
R&S SMBV100A base unit equipped with:
●
Option baseband generator (R&SSMBV-B51)
●
Option frequency (R&SSMBV-B1xx)
●
Option DFS (R&SSMBV-K350)
R&SSMM
R&SSMM base unit equipped with:
●
Option DFS (R&SSMM-K350)
9User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
R&S SGT100A
R&S SGT100A base unit equipped with:
●
Option frequency (R&SSGT-KB106)
●
Option baseband generator (R&SSGT-K510)
●
Option memory extension for ARB (R&SSGT-K51x)
●
Option DFS (R&SSGT-K350)
R&SSMJ100A and R&SSMU200A
R&SSMJ100A or R&SSMU200A base unit equipped with:
●
Option baseband generator (R&SSMJ/SMU-B9)
●
Option baseband main module (R&SSMJ/SMU-B13)
●
Option frequency (R&SSMJ/SMU-B106)
●
Option DFS (R&SSMJ/SMU-K350)
Getting started
Installing the software
2.2Installing the software
Software updates and the release notes describing the improvements and modifications are available for download at the product page https://www.rohde-schwarz.com/
software/pulse-sequencer/.
Software and hardware requirements
Minimum requirements:
●
Software
–
Microsoft®Windows 10, 64-Bit operating system (x64-based or x86-based processor)
–Microsoft Excel (recommended)
●
Hardware
Table 2-1: Hardware requirements
AMD or Intel CPUDual Core, 2 GHzIntel Core i7
RAM≥ 2 GB8 GB
VideoNVIDIA Quadro 128 MB or ATI RadeonNVIDIA Quadro 128 MB or ATI
Minimum requirementsRecommended hardware
Radeon
Video resolution≥ 1280 x 1024 pixels≥ 1920 x 1200 pixels
NetworkLAN 1 GB/sLAN 1 GB/s
To install the software
Download the R&S Pulse Sequencer (DFS) software form the Rohde & Schwarz website.
10User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
The R&S Pulse Sequencer (DFS) software consists of the file
PS-DFS-Install <major>.<minor>.<build>.<release>.msi.
1. Start the PS-DFS-Install <major>.<minor>.<build>.<release>.msi
file.
The filename follows the naming conventions:
●<major>.<minor> is the software version
●<build> is the build number.
This is the day elapsed since 1 January 2000
●<release> indicates the release on the build date.
This is 1/10 of the number of seconds elapsed since midnight.
●x64 indicates that this is a 64-bit installation file.
You can run the software version with the extension x64 only on a 64-bit operating system, see "Software and hardware requirements"on page 10.
2. Depending on your user rights, select one of the following:
a) Installation for all users (default)
Getting started
Installing the software
●Requires administrator rights
●Is a per-machine installation
●Project data and program data are common to all users
●Users keep their individual settings
b) Installation for current user only
●Does not require administrator rights
●Is a per-user installation
●Installation in %HomePath%
3. Choose the setup type.
4. Follow the installation instructions.
The installer performs the following actions:
●If enabled, installs the R&S VISA software on the PC
●Installs the R&S Pulse Sequencer (DFS) software including an uninstall tool
●Creates a shortcut on the desktop
●Creates the folder structure listed in Table 2-2.
Table 2-2: Default file location (software installation for all users)
2.3Starting the R&S Pulse Sequencer (DFS) for the first
time
► On your PC, select "Start > R&S Pulse Sequencer (DFS) > R&S Pulse Sequencer
(DFS)"
The R&S Pulse Sequencer (DFS) workspace opens. When you start the software
for the first time, the "Repository Manager" dialog opens.
Follow the steps described in Chapter 2.5, "Loading a DFS project file",
on page 17.
See also Chapter A, "Overview of the test requirements and provided test pat-
terns", on page 43.
2.4Understanding the displayed information
The following figure shows an example test scenario during software operation. The
different information areas are labeled. They are explained in more detail in the following sections.
12User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
Getting started
Understanding the displayed information
Figure 2-1: R&S Pulse Sequencer (DFS) default workspace: understanding the displayed information
1= Title bar
2= Menu bar with standard functions, e.g. save/open file etc.
3= Toolbar
4= Project tree (repository tree)
5= Screens for individual scenarios
6= Work area
4+6 = Workspace
7= Taskbar with indication of enabled remote control incl. details like IP address (if enabled), information
on the required highest security level (if enabled) and access to active dialogs
The user interface of the R&S Pulse Sequencer (DFS) offers an intuitive operating concept. Operation is similar to any operating system. All menus and dialogs use known
elements, e.g., selection lists, checkboxes, and entry fields.
13User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
Menu bar
Table 2-3: Content of the menu bar
Getting started
Understanding the displayed information
FileRepositoryConfigure
●
New Repository
●
Load or Manage Repositories
●
Save Repository
●
Import Repository Archive
●
Export Repository
●
Clear Workspace
●
Open Workspace
●
Save Workspace
●
Save Workspace As
●
Exit
Quick access
to currently
loaded repository
●
Signal Generators
●
Remote
Control
●
Colors
●
Settings
Toolbars
The R&S Pulse Sequencer (DFS) offers two toolbars.
Standard functions can be performed via the icons in the main toolbar at the top of the
screen.
ToolsWindowHelp
●
●
●
Script
Control
Panel
Console
●
●
●
●
●
●
Message
Log
SCPI Log
MinSize All
Windows
Cascade
Close All
Screen 1 ..
4
●
●
●
●
●
●
●
Online
Help
Documentation
SDK
Tutoriaks
Find
conncetors
Debug
Information
About
Figure 2-2: Standard functions in the main toolbar
1 = Save as: stores current workspace configuration
2 = Repository:
- = Creates a repository
- = Opens "Manage Repository" dialog for loading, discarding or exporting repositories
3 = Project tree > creates a scenario
4 = Generator:
- = Opens the "Signal Generators" dialog
- = Opens the signal generator "control panel"
5 = Logs:
- = Opens the "Message Log" window
- = Opens the "SCPI Log" window
6 = Screen: switches between the virtual screens
7 = Opens the "Program Settings" dialog
8 = Help:
- = Opens the "SDK" folder
- = Opens the help documentation folder containing help documents
- = Displays context-sensitive help topic for currently selected element
9 = Hardcopy: copies current dialog to the clipboard
14User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
Functions relating to the "Project Tree" can be performed via the icons in the toolbar
below the main toolbar.
Figure 2-3: Functions in the Project Tree toolbar
1 = Filters out the displayed elements in the "Project Tree" and displays, for example, only the uppermost
node, i.e. scenarios ("Show = Only Scenarios")
2 = Moves the elements within a node up/down in the "Project Tree"
3 = Expand/collapse all nodes in the "Project Tree"
Virtual screens
Using the R&S Pulse Sequencer (DFS) you can handle several scenarios with even
comprehensive settings at the same time. You can arrange the dialogs across multiple
screens logically, so that you can easily switch between them. You can, for example,
assign the subset of antenna dialogs to one screen and the pulse and modulation dialogs to another.
Getting started
Understanding the displayed information
Repository tree
The repository tree shows the content of all currently loaded repositories. Repository
elements are indicated with the assigned icons, their names, and the first comment
line.
= Name
1
2 = First comment line
15User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
Name and comment
Each repository element is identified with its unique name and optional description
entered in the comment field. The description can contain several lines; new line is
added by pressing [Shift+Enter].
1 = A unique name to indicate the element in the repository
2 = Description; the first line is displayed in the repository tree
Getting started
Understanding the displayed information
Context-sensitive menus
All user interface controls provide a context-sensitive menu. Context-sensitive menus
are accessed with a right mouse click on the control.
= Context menu of an icon
1
2 = Context menu of a parameter
Tooltips
Tooltips indicate the possible value range of a parameter or list overview information on
current settings.
= Tooltip of a setting parameter, indicating the allowed value range
1
2 = Tooltip with detailed information on a setting
16User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
Dialog names
The name of a dialog indicates its content or the functionality this dialog covers. The
used naming convention helps you to recognize which database element you are configuring, to which scenario it belongs and what its current name is.
Undocking dialogs
If your workspace contains several simultaneously opened dialogs, you can undock
dialogs and distribute them also outside the workspace, for example place them on a
second monitor.
1
= Undocks the dialog
Getting started
Loading a DFS project file
Keyboard shortcuts
Keyboard shortcuts are available for the most common functions in the software.
2.5Loading a DFS project file
We assume that you have started the R&S Pulse Sequencer (DFS), as described in
Chapter 2.3, "Starting the R&S Pulse Sequencer (DFS) for the first time", on page 12.
1. In the R&S Pulse Sequencer (DFS), the "Repository Manager" dialog is open.
2. In the "Repository Manager", select the required standard, e.g. "FCC > DFS FCC
06-96".
Repository files contain all signal definitions and report templates, as required for
the selected standard.
See also Chapter 3.1, "Normative reference", on page 24.
3. Select "Load".
The project tree opens and lists the project content.
Your workspace contains the selected predefined FCC test patterns.
18User Manual 1177.5327.02 ─ 17
R&S®Pulse Sequencer (DFS)
Getting started
Getting information and help
Figure 2-5: R&S Pulse Sequencer (DFS) workspace: Understanding the displayed information
1 = Project tree displaying the loaded DFS FCC test patterns
2 = Scenario dialog displaying a loaded test pattern (DFS FCC 06-96 Type 1)
See:
●Chapter 4, "Generating test files and conducting the trials", on page 25
●Chapter A, "Overview of the test requirements and provided test patterns",
on page 43
2.6Getting information and help
If any questions or problems concerning the R&S Pulse Sequencer (DFS) arise, an
extensive online help system is provided in the software and can be consulted at any
time.
The integrated help system provides the description of all functions. The help system is
context-sensitive and provides information specifically for the current operation or setting to be performed. In addition, general topics provide an overview on complete tasks
or function groups and background information.
Functions that are the same as in the R&S®Pulse Sequencer are not described in this
manual.
You find information on them in the online help system and in the R&S®Pulse
Sequencer user manual.
19User Manual 1177.5327.02 ─ 17
Loading...
+ 42 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.