Rohde and Schwarz TMU925 User Manual

R&S® TMU9
For information only! This manual, dated December 19, 2012, reflects the technical status as of that date. There may have been technical changes since that time.
Transmitter System

System Manual

(J0ÄG2)
2600.5423.02 ─ 01
System Manual
© 2012 Rohde & Schwarz GmbH & Co. KG
Muehldorfstr. 15, 81671 Munich, Germany
Phone: +49 89 41 29 - 0
Fax: +49 89 41 29 12 164
E-mail: info@rohde-schwarz.com
Internet: http://www.rohde-schwarz.com
Printed in Germany – Subject to change – Data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
The following abbreviations are used throughout this manual: R&S®XYZ1234 is abbreviated as R&S XYZ1234
KONFORMITÄTSERKLÄRUNG gemäß dem Gesetz über Funkanlagen und Telekommunikationsendeinrichtungen (FTEG) und der Richtlinie 1999/5/EG (R&TTE) Anhang V, zertifiziert durch die Benannte Stelle CETECOM ICT Services GmbH, Kennnummer 0682.
DECLARATION OF CONFORMITY in accordance with the Radio and Telecommunications Terminal Equipment Act (FTEG) and Directive 1999/5/EC (R&TTE Directive) Annex V, certified by the Notified Body CETECOM ICT Services GmbH Germany, Identif. No. 0682.
Zertifikat-Nr.: / Certificate No.: 2012-55
Hiermit wird in alleiniger Verantwortung bescheinigt, dass die Funkanlage
We herewith certify under our sole responsibility that the radio equipment
Gerätetyp
Equipment Type
Benennung
Designation
TMU9 Mittelleistungssender / Medium Power
Transmitter
Geräteklasse: / Equipment class: 2.10 (Broadcast transmitter) bei bestimmungsgemäßer Verwendung den grundlegenden Anforderungen des § 3 und den übrigen
einschlägigen Bestimmungen des FTEG (Artikel 3 der R&TTE) entspricht.
complies with the essential requirements of §3 and the other relevant provisions of the FTEG (Article 3 of the R&TTE Directive), when used for its intended purpose.
Gesundheit und Sicherheit gemäß § 3 (1) 1, (Artikel 3 (1) a))
Health and safety requirements pursuant to § 3 (1) 1, (Article 3(1) a))
Schutzanforderungen in Bezug auf die elektromagn. Verträglichkeit § 3 (1) 2, (Artikel 3 (1) b))
Protection requirements concerning electromagnetic compatibility § 3(1)(2), (Article 3(1)(b))
Maßnahmen zur effizienten Nutzung des Funkfrequenzspektrums § 3 (2), (Artikel 3(2))
Measures for the efficient use of the radio frequency spectrum § 3 (2), (Article 3(2))
Luftschnittstelle bei Funkanlagen gemäß § 3(3), (Artikel 3(3))
Air interface of the radio systems pursuant to § 3(3), (Article 3(3))
Vorlage: 2012_55_TMU9.doc 3573.7015.05 / ÄI 01.00
Angewendete harmonisierte Normen:
Harmonized standards applied:
Einhaltung der grundlegenden Anforderungen auf andere Art und Weise (hierzu verwendete Standards/Spezifikationen):
Other means of proving conformity with the essential requirements (standards/specifications used):
EN 60950-1: 2006 ETSI EN 301489-1 V1.9.2 (2011-09) ETSI EN 301489-14 V1.2.1 (2003-05) ETSI EN 302296 V1.1.1 (2005-01) EN 61000-3-2: 2006 +A1 +A2 EN 61000-3-3: 2008
Reg TP SSB RU 005 Rec.1999/519/EG;
26. BImSchV
ROHDE & SCHWARZ GmbH & Co. KG Mühldorfstr. 15, D-81671 München
München, den 26. Oktober 2012 Zentrales Qualitätsmanagement GF-QP / Radde
Munich, 2012-10-26 Central Quality Management GF-QP / Radde
CE D/E-1
KONFORMITÄTSERKLÄRUNG gemäß dem Gesetz über Funkanlagen und Telekommunikationsendeinrichtungen (FTEG) und der Richtlinie 1999/5/EG (R&TTE) Anhang V, zertifiziert durch die Benannte Stelle CETECOM ICT Services GmbH, Kennnummer 0682.
DÉCLARATION DE CONFORMITÉ selon la loi sur les équipements radio et les équipements terminaux de télécommunications (FTEG) ainsi que selon la Directive 1999/5/CE (Directive R&TTE) Annexe V, certifié par l'Organisme Notifié CETECOM ICT Services GmbH Allemagne, numéro d'identification 0682.
Zertifikat-Nr.: / Certificat N° : 2012-55
Hiermit wird in alleiniger Verantwortung bescheinigt, dass die Funkanlage
Par la présente, nous certifions sous notre responsabilité exclusive que l'équipement radio
Gerätetyp
Equipment Type
TMU9 Mittelleistungssender / Émetteur
Benennung
Designation
moyenne
puissance
Geräteklasse: / Classe d'équipement : 2.10 bei bestimmungsgemäßer Verwendung den grundlegenden Anforderungen des § 3 und den übrigen
einschlägigen Bestimmungen des FTEG (Artikel 3 der R&TTE) entspricht.
est conforme aux prescriptions fondamentales du paragraphe 3 et aux autres prescriptions applicables de la loi susmentionnée (Article 3 de la Directive R&TTE), à condition qu'il soit utilisé dans les conditions stipulées.
Gesundheit und Sicherheit gemäß § 3 (1) 1, (Artikel 3 (1) a))
Prescriptions en matière de sécurité et de santé selon le paragraphe 3 (1) 1, (Article 3 (1) a))
Schutzanforderungen in Bezug auf die elektromagn. Verträglichkeit § 3 (1) 2, (Artikel 3 (1) b))
Prescriptions en matière de protection relative à la compatibilité électromagnétique selon le paragraphe 3 (1) (2) (Article 3 (1) b))
Maßnahmen zur effizienten Nutzung des Funkfrequenzspektrums § 3 (2), (Artikel 3(2))
Vorlage: 2012_55_TMU9.doc 3573.7015.05 / ÄI 01.00
Mesures pour l'utilisation efficace du spectre radioélectrique le paragraphe 3 (2), (Article 3(2))
Luftschnittstelle bei Funkanlagen gemäß § 3(3), (Artikel 3(3))
Interface radio des équipements radio selon le paragraphe 3 (3) (Article 3 (3))
Angewendete harmonisierte Normen:
Normes harmonisées utilisées :
Einhaltung der grundlegenden Anforderungen auf andere Art und Weise (hierzu verwendete Standards/Spezifikationen):
Autres moyens servant à établir la conformité aux prescriptions fondamentales (normes/spécifications utilisées) :
ROHDE & SCHWARZ GmbH & Co. KG Mühldorfstr. 15, D-81671 München
München, den 26. Oktober 2012 Zentrales Qualitätsmanagement GF-QP / Radde
Munich, le 2012-10-26 Gestion centrale de la qualité GF-QP / Radde
CE D/F-1
EN 60950-1: 2006 ETSI EN 301489-1 V1.9.2 (2011-09) ETSI EN 301489-14 V1.2.1 (2003-05) ETSI EN 302296 V1.1.1 (2005-01) EN 61000-3-2: 2006 +A1 +A2 EN 61000-3-3: 2008
Reg TP SSB RU 005 Rec.1999/519/EG;
26. BImSchV
Für Betrieb im Europäischen Wirtschaftsraum (EWR)
und zivilem Einsatz.
Hinweis gemäß dem Gesetz über "Funkanlagen und Telekommunikationsend-
einrichtungen" (FTEG) und der Europäischen Richtlinie 1999/5/EG:
Dieses Produkt darf innerhalb des EWR nicht uneingeschränkt betrieben werden, da der verwendete Frequenzbereich auf nicht harmonisierten Bändern erfolgt. Nationale V orschriften / Genehmigungen sind zu beachten. Das Gerät ist 4 Wochen vor Inverkehrbringen bei der jeweils zuständigen nationalen Behörde für die Frequenzhoheit zu notifizieren. Informationen hierzu im Internet unter folgender Adresse: http://europa.eu.int/comm/enterprise/rtte/spectr.htm
For operation in the European Economic Area (EEA)
and civil use.
Note pursuant to the German Radio and Telecommunications Terminal Equip-
ment Directive (FTEG) and the European R&TTE Directive 1999/5/EC:
Operation of this product within the EEA is subject to restrictions since the frequency bands used are not harmonised. National provisions / authorizations shall be com­plied with. The product shall be notified to the competent national frequency management
authority four weeks before the product is put on the market. For more information refer to: http://europa.eu.int/comm/enterprise/rtte/spectr.htm
Printed in Germany
2101.6093.54 - EU - D/E-2
Quality management
Certied Quality System
ISO 9001
and environmental management
Sehr geehrter Kunde,
Sie haben sich für den Kauf eines Rohde & Schwarz Produk­tes entschieden. Sie erhalten damit ein nach modernsten Fer­tigungsmethoden hergestelltes Produkt. Es wurde nach den Regeln unserer Qualitäts- und Umweltmanagementsysteme entwickelt, gefertigt und geprüft. Rohde & Schwarz ist unter ande­rem nach den Managementsys­temen ISO 9001 und ISO 14001 zertifiziert.
Der Umwelt verpflichtet
Energie-efziente,
RoHS-konforme Produkte
❙ Kontinuierliche
Weiterentwicklung nachhaltiger Umweltkonzepte
ISO 14001-zertiziertes
Umweltmanagementsystem
Dear customer,
You have decided to buy a Rohde & Schwarz product. This product has been manufactured using the most advanced meth­ods. It was developed, manufac­tured and tested in compliance with our quality management and environmental manage­ment systems. Rohde & Schwarz has been certified, for exam­ple, according to the ISO 9001 and ISO 14001 management systems.
Environmental commitment
Energy-efcient products ❙ Continuous improvement in
environmental sustainability
ISO 14001-certied
environmental management system
Certied Environmental System
ISO 14001
Cher client,
Vous avez choisi d’acheter un produit Rohde & Schwarz. Vous disposez donc d’un produit fabriqué d’après les méthodes les plus avancées. Le dévelop­pement, la fabrication et les tests de ce produit ont été effec­tués selon nos systèmes de management de qualité et de management environnemental. La société Rohde & Schwarz a été homologuée, entre autres, conformément aux systèmes de management ISO 9001 et ISO 14001.
Engagement écologique
Produits à efcience
énergétique
❙ Amélioration continue de la
durabilité environnementale
❙ Système de management
environnemental certié selon
ISO 14001
1171.0200.11 V 05.01
1171020011
Customer Support
Technical support – where and when you need it
For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde & Schwarz equipment.
Up-to-date information and upgrades
To keep your instrument up-to-date and to be informed about new application notes related to your instrument, please send an e-mail to the Customer Support Center stating your instrument and your wish. We will take care that you will get the right information.
Europe, Africa, Middle East
North America
Latin America
Asia/Pacific
China
Phone +49 89 4129 12345
customersupport@rohde-schwarz.com
Phone 1-888-TEST-RSA (1-888-837-8772)
customer.support@rsa.rohde-schwarz.com
Phone +1-410-910-7988
customersupport.la@rohde-schwarz.com
Phone +65 65 13 04 88
customersupport.asia@rohde-schwarz.com
Phone +86-800-810-8228 / +86-400-650-5896
customersupport.china@rohde-schwarz.com
1171.0200.22-06.00
R&S® TMU9
2.2.1 Safety Instructions.........................................................................................................12

Contents

Contents
1 Information about this Manual..............................................................9
2 Safety Instructions...............................................................................11
2.1 Safety Instructions for Transmitter Systems and Equipment................................11
2.2 General Safety Instructions.......................................................................................12
2.3 Special Hazard Information
2.3.1 Hazards from AC Supply Voltage.................................................................................19
2.3.1.1 AC Power Supply..........................................................................................................19
2.3.1.2 Changing Fuses............................................................................................................19
2.3.2 Hazards from HighEnergy Electric Circuits..................................................................19
2.3.3 Hazards from RF Radiation...........................................................................................20
2.3.3.1 Obligation to Instruct Personnel....................................................................................20
2.3.3.2 RF Shielding..................................................................................................................20
2.3.3.3 Rules When Operating an Amplifier..............................................................................20
2.3.3.4 Rules When Working on an Open Amplifier..................................................................21
........................................................................................19
3 Transmitter System R&S TMU9..........................................................23
3.1 Design and Function R&S TMU9...............................................................................23
3.1.1 Rack Design..................................................................................................................23
3.1.2 Arrangement of the R&S TCE900 Instruments and System Components....................23
3.1.3 Redundancy Concepts..................................................................................................25
3.1.4 Applications...................................................................................................................28
3.1.5 Overview of Modules and Devices................................................................................30
3.1.5.1 Mains Distribution Unit..................................................................................................30
3.1.5.2 Transmitter Control Unit................................................................................................31
3.1.5.3 TSP900 (Transmitter Status Panel)..............................................................................32
3.1.5.4 Exciter and System Components..................................................................................34
3.1.5.5 Output Stage Unit..........................................................................................................34
3.1.5.6 OSKAR Coupler Module...............................................................................................35
3.1.5.7 External Directional Coupler (GD901/902)....................................................................35
3.1.5.8 Bandpass Filter.............................................................................................................35
3.1.5.9 RF Connector................................................................................................................36
3System Manual 2600.5423.02 ─ 01
R&S® TMU9
3.1.5.10 Parallel Remote Control Interface.................................................................................36
3.1.5.11 Exhaust Kit (optional)....................................................................................................39
3.1.6 Performance Features..................................................................................................40
Contents
3.1.7
3.1.8 Specifications................................................................................................................42
3.1.8.1 Transmitter System, General – DTV.............................................................................42
3.1.8.2 Requirements for the Output Bandpass Filter...............................................................46
3.1.8.3 Parallel Remote Control Interface.................................................................................50
3.2.1 Equipment Supplied......................................................................................................50
3.2.1.1 Integrated Transmitter Components.............................................................................50
3.2.1.2 Transmitter Components Supplied Separately.............................................................50
3.2.2 Overview of Transmitter Installation..............................................................................51
3.2.2.1 Required Tools..............................................................................................................51
3.2.3 Setting Up the Transmitter............................................................................................52
3.2.3.1 Preparatory Work..........................................................................................................52
3.2.3.2 Setting Up the Transmitter Rack...................................................................................53
3.2.3.3 Aligning the Transmitter Rack.......................................................................................53
3.2.3.4 Bolting the Transmitter Rack to the Floor......................................................................53
Power Display and Reflection Monitor..........................................................................41
3.2 Installation R&S TMU9................................................................................................50
3.2.3.5 Removing the Front Panels...........................................................................................53
3.2.3.6 Unpacking the Components..........................................................................................54
3.2.4 Installing the UHF Channel Bandpass Filter.................................................................54
3.2.5 Installing the Amplifier...................................................................................................55
3.2.6 Installing the Power Supply...........................................................................................56
3.2.6.1 General.........................................................................................................................56
3.2.6.2 Connecting the Transmitter Ground..............................................................................57
3.2.6.3 Connecting the Power Cable........................................................................................57
3.2.7 Installing the RF output.................................................................................................59
3.2.7.1 Connecting the Antenna................................................................................................59
3.2.7.2 Connecting the Dummy Antenna..................................................................................59
3.2.8 Installing R&S TCE900 Customer Interfaces................................................................60
3.2.9 Installing the RF Loop...................................................................................................62
3.2.9.1 Single Drive (CAN Bus Adapter)...................................................................................62
4System Manual 2600.5423.02 ─ 01
R&S® TMU9
3.2.9.2 Dual Drive (RF Switch)..................................................................................................63
3.2.10 Installing the TM9-C1 Exhaust Kit.................................................................................63
Contents
3.3 Commissioning R&S TMU9........................................................................................65
4 Exciter/Transmitter Control R&S TCE900
4.1 Design and Function R&S TCE900............................................................................67
4.1.1 R&S TCE900 General Design.......................................................................................67
4.1.2 R&S TCE900 Functions................................................................................................71
..........................................67
5 Amplifier R&S PMU901........................................................................73
5.1 Design and Function R&S PMU901...........................................................................73
5.1.1 Device Purpose and Overview......................................................................................73
5.1.2 Mechanical Design........................................................................................................74
5.1.3 Display Elements and Interfaces...................................................................................77
5.1.3.1 LEDs and Test Point – Front Panel...............................................................................77
5.1.3.2 Connectors – Rear Panel..............................................................................................79
5.1.4 Circuit Descriptions.......................................................................................................81
5.1.4.1 Block Diagram...............................................................................................................81
5.1.4.2 Signal Gain in Preamplifier and Driver..........................................................................81
5.1.4.3 Signal Gain in Doherty-Capable Output Stage.............................................................82
5.1.4.4 Power Control...............................................................................................................83
5.1.4.5 SelfProtection Mechanisms..........................................................................................84
5.1.4.6 Emergency Shutdown...................................................................................................86
5.1.5 Specifications................................................................................................................86
5.1.5.1 General Data.................................................................................................................86
5.1.5.2 Digital TV (DTV)............................................................................................................87
5.1.5.3 Analog TV (ATV Combined)..........................................................................................88
5.1.5.4 CW Mode......................................................................................................................88
A R&S TMU9 Interface Description........................................................91
A.1 External Transmitter Interfaces.................................................................................91
A.1.1 Transmitter Input AC.....................................................................................................91
A.1.2 Input Signals (TS, RF, Reference)................................................................................91
A.1.3 Transmitter Output........................................................................................................94
A.1.4 Monitoring Signals (TS, RF, Reference).......................................................................94
5System Manual 2600.5423.02 ─ 01
R&S® TMU9
A.1.5 Remote interfaces.........................................................................................................95
A.2.1 Internal RF Interfaces....................................................................................................95
A.2.2 Internal Ethernet Interfaces...........................................................................................97
Contents
A.2 Internal Transmitter Interfaces..................................................................................95
A.2.3
A.2.4 RF Loops.......................................................................................................................98
A.2.5 TSP900 – Display Interface..........................................................................................98
A.2.6 TDU900 – Display Interfaces (Optional).......................................................................99
A.2.7 Air Cooling Interface (Optional).....................................................................................99
Transmitter Control Bus (CAN bus)..............................................................................98
B R&S TCE900 Interface Description...................................................101
B.1 Interfaces of Base Unit ............................................................................................101
B.1.1 X1: MAINS..................................................................................................................101
B.1.2 Interfaces of Main Computer IPS1..............................................................................101
B.1.2.1 X2 LAN REMOTE.......................................................................................................101
B.1.2.2 X14 USB 1..................................................................................................................101
B.1.2.3 X15 USB 2..................................................................................................................102
B.1.2.4 X11 DVI.......................................................................................................................102
B.1.3 Interfaces of System Connection Boards (SCB).........................................................103
B.1.3.1 X3 LAN LOCAL FRONT..............................................................................................103
B.1.3.2 X7 LAN LOCAL REAR................................................................................................103
B.1.3.3 X66 GPS ANTENNA...................................................................................................104
B.1.3.4 X12 TERMINAL SUPPLY...........................................................................................104
B.1.3.5 X6 TX..........................................................................................................................105
B.2 Module Slots..............................................................................................................105
B.2.1 Coder Board................................................................................................................105
B.2.1.1 X30 TS LAN 1.............................................................................................................105
B.2.1.2 X31 TS LAN 2.............................................................................................................106
B.2.1.3 X23 1PPS IN...............................................................................................................106
B.2.1.4 X24 REF MONITOR....................................................................................................106
B.2.1.5 X20 TS1 IN..................................................................................................................107
B.2.1.6 X21 TS2 IN..................................................................................................................107
B.2.1.7 X22 TS MONITOR OUT..............................................................................................107
B.2.2 RF Board.....................................................................................................................107
6System Manual 2600.5423.02 ─ 01
R&S® TMU9
B.2.2.1 X64 REF IN.................................................................................................................107
B.2.2.2 X60 RF OUT...............................................................................................................108
Contents
B.2.2.3 X61 RF MONITOR OUT
B.2.2.4 X67 RF DOWNCONVERTER 1 IN.............................................................................108
B.2.2.5 X68 RF DOWNCONVERTER 2 IN.............................................................................108
B.2.3 Tx Interface.................................................................................................................109
B.2.3.1 X40 LAN 1...................................................................................................................109
B.2.3.2 X41 LAN 2...................................................................................................................109
B.2.3.3 X42 LAN 3...................................................................................................................110
B.2.3.4 X43 LAN 4...................................................................................................................110
B.2.3.5 X44 Power Distributor.................................................................................................111
B.2.3.6 X45 Rf Switch PAR IO................................................................................................112
B.2.4 Cooling Interface (CIF)................................................................................................113
B.2.4.1 X46 Pump...................................................................................................................113
B.2.4.2 X47 HEX.....................................................................................................................114
B.2.5 Air Cooling Interface (Optional)...................................................................................116
B.2.5.1 Connection to Exhaust Fan, Differential Pressure Sensor, X46 FAN1.......................116
B.2.5.2 Connection to Exhaust Fan, Differential Pressure Sensor, X47 FAN2.......................116
.............................................................................................108
C R&S PMU901 Interface Description..................................................119
C.1 X1: Supply Input; Schaltbau M3 connector............................................................119
C.2 X2: RF Output 7/16 - Socket (Rear)..........................................................................120
C.3 X3: RF Test Socket; SMA Female (Front)...............................................................120
C.4 X10: RF Input SMA Female (Rear)...........................................................................120
C.5 X13: Second RF Test Socket for ADE; SMA Female (Rear)..................................121
C.6 X22: Fan Connection 1; 4-pin Molex Connector....................................................121
C.7 X23: Fan Connection 2; 4-pin Molex Connector....................................................121
C.8 X11: Amplifier Control Unit; 15-pin D-Sub connector (rear).................................122
7System Manual 2600.5423.02 ─ 01
R&S® TMU9
Contents
8System Manual 2600.5423.02 ─ 01
R&S® TMU9
Information about this Manual

1 Information about this Manual

This manual is part of the documentation for the R&S TMU9 transmitter family from Rohde & Schwarz. The individual manuals for the transmitter family have a modular structure and complement each other.
Structure
The system manual, which is the central and overarching part of the overall documen­tation, describes all the steps involved in installing a transmitter.
Operation of the transmitter system after installation and the steps required to put the system into operation are described in the operating manual.
The service manual describes all maintenance, troubleshooting and service tasks that customers can carry out themselves. At certain points in the transmitter manual, the reader is referred to the appropriate operating manual or service manual.
Contents
The manuals for the transmitter family describe all activities required for installation, startup, component parts. The appendix contains the interface descriptions and the technical documentation.
Safety
All skilled personnel working with a transmitter or its components have a duty to read the associated manuals and to follow the safety measures described in the section "Safety" and given at appropriate points in the manual. It must be ensured that the transmitter and the individual components of the transmitter are used only for their intended purpose. All activities connected with the transmitter or individual transmitter components must be carried out by skilled personnel. If activities require additional skills and qualifications, this is indicated at the appropriate points in the manual.
Symbols and notation
The warning triangle symbol refers the reader to potential hazards. The degree of danger is indicated by different signal words next to the warning symbol.
Instructions are given in numbered steps. All other formatting options are intended to improve clarity and are selfexplanatory.
operation, maintenance,
troubleshooting and servicing of the transmitter and its
9System Manual 2600.5423.02 ─ 01
R&S® TMU9
Information about this Manual
10System Manual 2600.5423.02 ─ 01
R&S
®
TMU9
Safety Instructions

Safety Instructions for Transmitter Systems and Equipment

2 Safety Instructions

2.1 Safety Instructions for Transmitter Systems and Equip­ment
Compliance with safety regulations
The safety regulations specified in this manual must always be complied with.
The following points require special attention:
Only qualified technicians are allowed to install and wire the electrical equipment.
National and international safety rules and regulations must be observed when
equipping operating facilities and during the assembly and operation of electrical systems. These include, for example: – Protective measures to prevent accidents
Protection against overvoltage
Isolation of electrical systems
Grounding of electrical systems
Physical properties and laying of electrical lines and cables
Regulations that apply to factories, work areas and special systems
When installing transmitter racks, it is important to observe national accident pre-
vention regulations, for example, with regard to: – Crushing hazard when working beneath suspended loads
Fall hazards when working on ladders
Risk of injury when lifting heavy loads
Personal protective equipment (PPE) must be used when installation or repair work
is being carried out. Depending on the type of work, it may be necessary to wear protective clothing such as hard hats, safety gloves, eye protection, etc.
Instruments and systems must not be operated unless their cabinets are closed.
Observe the appropriate safety instructions when opening cabinets for maintenance or repair work.
Isolate all poles when disconnecting instruments and systems from the AC supply.
In addition, disconnect all external sources of power, i.e. all measuring cables, exten­sion cables and multipoint connectors (except for special service connectors). Then wait approx. 5 minutes to ensure that the capacitors in the system are sufficiently discharged.
Additional information on liquidcooled transmitters: When installing the cooling sys-
tem and filling it with coolant (pump and heat exchanger), the applicable regulations
11System Manual 2600.5423.02 ─ 01
R&S® TMU9
Safety Instructions
General Safety Instructions
on working with hazardous products (coolant) must be observed; see the section "Material Safety Data Sheets" under "EC Safety Data Sheet – Antifrogen".

2.2 General Safety Instructions

This section contains general safety instructions applying to all products manufactured or sold by Rohde & Schwarz.
In accordance with
IEC215 or EN60215, transmitter systems and their add-on equipment must be operated under the responsibility of qualified technicians only. The minimum requirements for qualified electricians are also defined in the standard "Safety require­ments for radio transmitting equipment".
Compliance with all legal and regulatory requirements is a precondition for operating radio equipment and systems. The operator or the operator's authorized representative is responsible for ensuring compliance with these requirements. They must additionally ensure that the training of the operating personnel satisfies the country-specific require­ments. This includes any periodic training that is necessary.
2.2.1 Safety Instructions
It is essential to read and observe the following instructions and safety informa­tion.
All factories and sites of the Rohde & Schwarz company group continuously strive to ensure that our products meet the very latest safety standards and that our customers are provided with the highest possible degree of safety. Our products and any additional equipment that they require are manufactured and tested in accordance with the appli­cable safety regulations. Our quality assurance department regularly checks if these standards are met. This product has been manufactured and tested in accordance with the enclosed EC Certificate of Conformity and left the factory in a condition fully complying with the relevant safety standards. In order to keep the product in this condition and to ensure that it operates safely, the user must observe all information, warnings and instructions. Please do not hesitate to contact the Rohde & Schwarz company group if you have any queries regarding these safety instructions.
Additionally, it is the responsibility of the user to ensure that the product is operated in the appropriate manner. The product is intended for industrial and laboratory use only and, if expressly authorized, also for use in the field, and must never be used in such a way that may result in injury to personnel or damage to property. The user shall be held responsible if the product is used for purposes other than those specified or in such a way that disregards the instructions from the manufacturer. The manufacturer shall not be liable for any consequences resulting from the product being used for purposes other than those for which it is intended.
Use of the product for its intended purpose is assumed if the product is used in accord­ance with the specifications given in the associated product documentation and within its performance limits (see the data sheet, documentation and the following safety instruc-
12System Manual 2600.5423.02 ─ 01
Loading...
+ 45 hidden pages